| 1 | 1 | Supply and erection MS swaged tublar pole with base plate and foundation bolt & nut and single ornamental bracket two coats of zinc chromate and two coats of aluminium / epoxy painting. Pole height 7.5mt. Pole dimension - 139.7 x 4.50 x 3000mm , 114.3 x 3.65 x 2250mm, 88.9 x 3.25mm x 2250mm bracket dimension 60.3mm x 3.65mm x 2700mm - 1no, base plate dimension 300mm x 300mm x 10mm. with stiffner plate. Overall height 9 mt. Including excavation of earth 750 x 750 x 1500mm and cement concrete 1:2:4 - 750 x 750 x 1500mm for filling and capping above ground level 450mm dia x 600mm height. One coat of zinc chromate and two coat of aluminium/epoxy painting should be done after erection of the pole and inclusive of suitable length 1.50mt.- 2 nos. of 40mm dia medium class GI pipe for cable raising.\n | BI01010001010000000000000515BI0100001113 | 200 | No |
|---|
| 2 | 2 | Supply and erection MS swaged tublar pole with base plate and foundation bolt & nut and double ornamental bracket two coats of zinc chromate and two coats of aluminium / epoxy painting. Pole height 7.5mt. Pole dimension - 139.7 x 4.50 x 3000mm , 114.3 x 3.65 x 2250mm, 88.9 x 3.25mm x 2250mm bracket dimension 60.3mm x 3.65mm x 2700mm - 2nos, base plate dimension 300mm x 300mm x 10mm. with stiffener plate. Overall height 9 mt. including excavation of earth 750 x 750 x 1500mm and cement concrete 1:2:4 - 750 x 750 x 1500mm for filling and capping above ground level 450mm dia x 600mm height. One coat of zinc chromate and two coat of aluminium/epoxy painting should be done after erection of the pole and inclusive of suitable length 1.50mt.- 2 nos. of 40mm dia medium class GI pipe for cable raising.\n | BI01010001010000000000000515BI0100001114 | 50 | No |
|---|
| 3 | 3 | Supply and erection MS swaged tublar pole at top with base plate and triple ornamental bracket two coats of zinc chromate and two coats of aluminium / epoxy painting. Pole height - 8mt. Pole dimension - 139.7 x 4.5 x 4500mm , 114.3 x 3.65 x 1750mm, 88.9 x 3.25mm x 1750mm, bracket dimension, 60.3mm x 3.65mm x 2700mm - 3no, base plate dimension 300mm x 300mm x 5mm. Overall height - 9.5mts. Including excavation of earth 750x 750 x1650mm and cement concrete 1: 2: 4 of volume 750 x750 x 1650mm filling and capping above ground level 450mm dia x 600mm height. One coat of zinc chromate and two coat of aluminium/epoxy painting should be done after erection of the pole and inclusive of suitable length 1.25mt.- 2 nos. of 40mm dia medium class GI pipe for cable raising.\n | BI01010001010000000000000515BI0100001115 | 20 | No |
|---|
| 4 | 4 | Supply and fixing of LED street light fitting in existing / New street light arms having 120watts and above (System Wattage), IP 65 / 66 white colour with necessary over voltage, under voltage and surge protection with three years onsite warranty for replacement / Rectification. Make:Philips /Havells /Crompton / Bajaj / LED GEO. The rate is inclusive of all taxes | BI01010001010000000000000515BI0100001116 | 360 | No |
|---|
| 5 | 5 | Fixing testing and commissioning of Sodium vapour/Mercury vapour/Metal halide street light fittings on existing poles as required\n | BI01010001010000000000000515BI0100001117 | 360 | No |
|---|
| 6 | 6 | Supplying and drawing of 2.5sqmm FR PVC insulated, copper conductor, single core cable in the existing surface/ recessed, PVC/steel conduit/PVC casing and capping as required Make: Finolex / Polycab | BI01010001010000000000000515BI0100001118 | 11880 | No |
|---|
| 7 | 7 | Supplying and fixing 6 amps to 32 amps rating ,Single pole,240 volts,'c' series,miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Make:ABB/L&T Hager\n | BI01010001010000000000000515BI0100001119 | 360 | No |
|---|
| 8 | 8 | Supplying and fixing of 280 x 170 x 130 mm outer (240 x 130 x 110 mm inner) size PVC junction box- Sintex.\n\n | BI01010001010000000000000515BI0100001120 | 360 | No |
|---|
| 9 | 9 | Supplying of 4 x 16sqmm of armoured aluminium U.G cable – 1.1KV grade. (Make – Finolex / Polycab). | BI01010001010000000000000515BI0100001121 | 6750 | No |
|---|
| 10 | 10 | Supplying of 4 x 25sqmm of armoured aluminium U.G cable – 1.1KV grade. (Make – Finolex / Polycab). | BI01010001010000000000000515BI0100001122 | 800 | No |
|---|
| 11 | 11 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade of size not exceeding 25sq.mm direct in ground including excavation, sand cushioning,protective covering and refillilng the trench etc as required Mud Road | BI01010001010000000000000515BI0100001123 | 4500 | No |
|---|
| 12 | 12 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade of size not exceeding 25sq.mm direct in ground including excavation, sand cushioning,protective covering and refillilng the trench etc as required Bituminous Road | BI01010001010000000000000515BI0100001124 | 3000 | No |
|---|
| 13 | 13 | Supplying and making end termination with copper gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1KV grade as required:4 X 16 Sq.mm\n | BI01010001010000000000000515BI0100001125 | 540 | No |
|---|
| 14 | 14 | Supplying and making end termination with copper gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1KV grade as required:4 X 25 Sq.mm\n | BI01010001010000000000000515BI0100001126 | 40 | No |
|---|
| 15 | 15 | Supply and fixing of 40mm dia. green spring hose | BI01010001010000000000000515BI0100001127 | 1620 | No |
|---|
| 16 | 16 | Supply and laying of 40 mm dia. GI pipe medium class | BI01010001010000000000000515BI0100001128 | 1900 | No |
|---|
| 17 | 17 | Earthing with G.I.medium pipe 3.0 mt long and 40mm dia including accessories 250 x 50 x 6 mm G.I clamp with 12mm bolt, nut and washer for connecting earth wire, RCC ring enclosure and cover plate complete as required\n | BI01010001010000000000000515BI0100001129 | 40 | No |
|---|
| 18 | 18 | Extra for salt and charcoal for pipe earth electrode as required: | BI01010001010000000000000515BI0100001130 | 40 | No |
|---|
| 19 | 19 | Supplying of 8 SWG copper wire (4.0 mm dia. | BI01010001010000000000000515BI0100001131 | 40 | No |
|---|
| 20 | 20 | Supplying and fixing of 125/200/250/315A DIN HRC fuse base. Make:Standard/ Havells/C&S\n\n | BI01010001010000000000000515BI0100001132 | 60 | No |
|---|
| 21 | 21 | Supplying and fixing of 32-100A HRC fuse link (DIN type) Make:Standard/ Havells/ C&S/L&T\n\n | BI01010001010000000000000515BI0100001133 | 60 | No |
|---|
| 22 | 22 | Supplying and fixing of Aerial board\n\n | BI01010001010000000000000515BI0100001134 | 20 | No |
|---|
| 23 | 23 | Supplying and fixing of Pole clamp\n\n | BI01010001010000000000000515BI0100001135 | 40 | No |
|---|
| 24 | 24 | Fabrication, supply, erection, testing and commissioning of one no of Timer and metering panel board for the power supply of over all size 1100mm x 650mm x 250mm made out of 16SWG thick cold rolled M.S. Sheet. The front side compartment have energy meter with viewing glass with 10mm hylem sheet. The back side compartments with 40 – 63A rating, TPN MCB, “C Series, 10KA breaking capacity (Make – Siemens/ABB), 1no. of Timer switch (Daily) analog with battery backup to 200hrs. (Make – L&T – Hagger/ Legrand - Lexic), 1no. 60A power contactor (Make – C&S), 1no. of toggle switch (Make – C&S), 3nos of signal lamp (Blue, Red, Yellow). (Make – Siemens/C&S/ L&T/Teknic). The switch units are to be fixed with in the allotted size in the 10mm hylem sheet. The bottom sheet of the shell should be of 16SWG thick cold rolled M. S. Sheet with brass gland for cable entry. The panel has to be mounted on the floor with in the height of 375mm. \n | BI01010001010000000000000515BI0100001136 | 20 | No |
|---|