Repair And Replacement Servicing Of Split And Window Type Ac ,Air Conditioner Plant Desert Cooler Water Coolers Refrigerators And Allied Works At Af Station Mandore Under Age Em Ge Af No 2 Jodhpur

Tender Notice

23416852
Repair And Replacement Servicing Of Split And Window Type Ac ,Air Conditioner Plant Desert Cooler Water Coolers Refrigerators And Allied Works At Af Station Mandore Under Age Em Ge Af No 2 Jodhpur
Indian
Rajasthan
18-02-2020
19-02-2020
20-02-2020

Tender Details

Repair And Replacement Servicing Of Split And Window Type Ac ,air conditioner Plant Desert Cooler Water Coolers Refrigerators And Allied Works At Af Station Mandore Under Age Em Ge Af No 2 Jodhpur

Corrigendum Details

Sr No CorrigendumDate Description Submission Date
1 18-02-2020 Date Amendment 19-02-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 6000.00 /-
Tender Value
INR 3 Lakhs /-

BOQ Items

Name of Work: Repair/replacement and servicing of split/window type AC, AC Plant, Desert Coolers, water coolers, refrigerators and allied works at AF Station Mandore under AGE E/M, GE (AF) No 2 Jodhpur
Sl. No. Item Description Item Code / Make Quantity Units
1 1 M&L for taking out unserviceable sealed unit(Reciprocating compressor) 1.5 ton capacity, single phase, 230 volt of Kirloskar/Tecumseh/Carrier Make including necessary modification of the foundation as required to suit the compressor, vacumisation, pressure, testing, leakage, rectification including gas charging R-22 and testing complete to the entire satisfaction of Engineer-in-Charge. 3 EACH JOB
2 2 M&L for taking out unserviceable sealed unit(Rotary compressor) 1.5 ton capacity, single phase, 230 volt of Highly hitachi/total line/Blue star//Tecumseh Make including necessary modification of the foundation as required to suit the compressor, vacumisation, pressure, testing, leakage, rectification cluding gas charging R-22 and testing complete to the entire satisfaction of Engineer-in-Charge. 3 EACH JOB
3 3 S&F in repairs running capacitor of capacity 45/50MFD, 440 volts, 50 Hz, complete all as specifed and directed Make-as per existing as per site. 5 EACH
4 4 S&F in repairs blower DC fan motor suitable for 1.5/2.0 Ton split AC of capacity Single Phase complete all as specifed and directed. Make- as per existing site. 5 EACH
5 5 S&F in repairs Running capacitor of capacity 5MFD/6 MFD, 230 volts, 50 Hz complete all as specifed and directed. Make- as per existing site. 20 EACH
6 6 S&F in repairs Starting capacitor of capacity 80-100 MFD, 230 volts, 50 complete all as specifed and directed. Make- as per existing site. 5 EACH
7 7 S&F in repairs wiring kit for capacity 1.5/2.0 ton AC complete all as specifed and directed. Make- as per existing site. 4 EACH
8 8 S&F in repairs condensing fan motor 1/5 HP single phase, 230 volts, 50 cycle per second suitable for Carrier window type AC complete all as specifed and directed. Make- as per existing site. 5 EACH
9 9 S&F in repairs condenser for window type AC 1.5 ton capacity of any make including charging of gas R-22 all as directed by Engineer-in-Charge. 4 EACH
10 10 S&F in repairs cooling coil for window type AC 1.5 ton capacity of any make including charging of gas R-22 all as directed by Engineer-in-Charge. 4 EACH
11 11 S&F in repairs thermostat suitable for any make of window type AC 1.5 ton capacitycomplete all as specifed and directed. Make- as per existing site. 4 EACH
12 12 M&L for finding out the leakage with the pressure test of the condenser or cooling coil of window type AC/split type AC of 1.5/2.0 ton and dismantling the same for repair, reassembling the same after repair the leakage point by brazing/soldering including charging the gas R-22 and testing the AC to the entire satisfaction of Engineer-in-Charge. 4 EACH JOB
13 13 M&L for replacement of PCB control card suitable for 1.5/2.0 TR capacity split type AC, single phase complete all as specifed and directed. Make- as per existing site. 2 EACH
14 14 Reparing of PCB control card suitable for 1.5/2.0 TR capacity split type AC, single phase complete all as specifed and directed. Make- as per existing site. . 2 EACH JOB
15 15 M&L for servicing of window type AC of 1.5/2.0 tone capacity by taking out the same from existing location, cleaning of condenser, cooling coil, and other components with cooling coil rinse solution and clean water, greasing of fan, motor, blower etc without damage any part and reinstall at the same location all as directed by the Engineer-in-Charge. 4 EACH JOB
16 16 Ditto as per items No 15 above but split type AC. 10 EACH JOB
17 17 S&F in repair copper tube of size ?” dia for any capacity of split type AC all as specified. 50 RM
18 18 M&L for insulating foam pipe of size ?", ¼", and ?" dia of split type AC any capacity for both indoor and outdoor unit all as specified. 30 RM
19 19 M&L for fan blade of suitable size for any capacity of window/Split type AC complete all as specifed and directed. Make- as per existing site. 4 EACH
20 20 S&F in repairs flexible PVC waste water pipe, 15/20 mm dia, of split type AC any capacity and any make 15 mm dia all as directed by Engineer-in-Charge. 40 RM
21 21 Supply, laying and commissioning of cable PVC sheathed with multistranded copper conductor of size 3 core 4 sqmm and including PVC conduit complete as specifed and directed. 20 RM
22 22 S&F in repairs of relay of split type AC of any make and any capacity all as specified. Make- as per existing site. 4 EACH
23 23 S&F in repair electronic circuit board with relay suitable for 4/5 KVA voltage stabilizer of any make and testing complete all as directed by Engineer-in- Charge. Make- as per existing site. 5 EACH
24 24 Ditto as per item No. 23 but capacity 5 KVA. 5 EACH
25 25 M&L for shifting of AC any type and capacity, from one location to another location including complete wiring, replacement of copper tubing with provn of complete insulation and leakage if any incl gas charging and testing after installation complete as directed. 3 EACH JOB
26 26 S&F air filter element suitable for split type AC 1.5/2.0 Ton capacity complete all as specified and directed. Make -As per existing site. 2 SET OF TWO
27 27 Supply & Fix sheet metal enclosure with a two pin and earth plug socket complete including with 25 Amps MCB Single pole 240 Volt AC. 4 Each
28 28 S&F in repairs Running capacitor for indoor coil motor of capacity 1.5/2/2.5 MFD, 230 volts, 50 Hz ,all as per sample required at site and directed by Engg -in charge. 5 EACH
29 29 M&Lfor repairs of caplliary tube of split /window type AC capacity 1.5/2.0 Ton and all as per specified and directed. Make as per existing site. 5 EACH
30 30 S&F single pole contactor suitable for split type AC capacity 1.5/2.0 Ton all as per specified and directed. Make as per existing site. 2 EACH
31 31 S&F in repair of flair nut size 5/8" and 1/2"dia for any capacity of split type AC all as specified. 10 EACH
32 32 S&F in repair of dead nut size 1/4 '' dia for any capacity of split type AC all as specified. 10 EACH
33 33 M&L for taking out unserviceable sealed unit (compressor) of water cooler of capacity storage/cooling 150/150 litres, single phase, 230 volt and replacing the same with new sealed unit (Compressor) of Make- Tecumesh/ Kirloskar/voltas, including necessary modification of the foundation as required to suit the compressor, vaccumization, pressure testing, leakage rectification, charging of gas R-22/R-134a, oil filling and testing complete to the entire satisfaction of the Engr-in-Charge. 5 EACH JOB
34 34 M&L for rewinding of condensing fan motor with super enameled copper wire (Make - Devi dayal/Chetak/ Usha/voltas thermal class E or any make specified in Appx 'B') single phase, 230 volts, capacity 1 HP for water cooler of capacity storage/cooling 150/150 litres complete all as specified and directed. 5 EACH JOB
35 35 M&L for repair to bottom rusted and deteriorated portion of body of 150/150 litres storage/cooling capacity of water cooler up to 300mm in height from bottom including replacement with 20 gauge mild steel sheet with necessary cutting, denting, welding including spray painting with one coat of approved synthetic enamel paint (Ist quality) over a coat of red oxide primer to the entire outer surface of the body after scraping, rubbing, and removing the existing old paint all as specified and directed. 5 EACH JOB
36 36 M&L for finding out the leakage with the pressure test of the condenser or cooling coil of water cooler 150/150 litres storage/cooling capacity and dismantling the same for repair, reassembling the same after repair of the leakage point by brazing/soldering including charging the gas R-22/R-134 and testing the water cooler to the entire satisfaction of the Engineer-in- Charge. 5 EACH JOB
37 37 S&F in replacement wiring kit for water cooler of any make and capacity. Make - Hi-Tech/Aanutrol/coolex/keyee 5 EACH
38 38 S&F in replacement 15 mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe (Minimum weight 142 gms) for water cooler complete all as per specified and directed. 4 EACH
39 39 S&F in replacement cast copper alloy,chromium plated lift cock of 15mm bore complete all as per specified and directed. 4 EACH
40 40 S&F in replacement of flexible PVC waste water pipe of water cooler any capacity and make as per existing all as directed by Engineer-in-charge. 4 EACH
41 41 S&F in replacement of capacitor 36 MFD for water cooler and make as per existing all as directed by Engineer-in-charge. 4 EACH
42 42 M&L for repair to bottom rusted and deteriorated portion of body of 286/300/310 litres capacity refrigerator up to 150 mm height by replacing with 20 gauge MS sheet, including cutting, denting, welding and spray painting to the entire body with two coats of approved synthetic enamel paint (Ist quality) over one coat of red oxide primer after rubbing/removing the existing old paint all as specified & writing SM No/MES No 40 to 50 mm high letter with white paint and also including charging of gascomplete all as per specified and directed. 1 EACH JOB
43 43 Ditto all as per item No. 42 above but refrigeratorcapacity 165-300 litres. 1 EACH JOB
44 44 S&F in replacement of condenser (heat exchanger) for Refrigerator capacity 165-300 ltr and make as per existing all as directed by Engineer-in-charge. Make as per existing site 1 EACH
45 45 S&F in replacement of condenser (heat exchanger) for Refrigerator capacity up 165 to 300 ltr and make as per existing all as directed by Engineer-in-charge. Make as per existing site 1 EACH
46 46 S&F in replacement of relay OLP set suitable for 165 to 300 ltr capacity of Refrigerator and make as per existing all as directed by Engineer-in-charge. Make as per existing site 1 EACH
47 47 M&L for rewinding of desert cooler fan motor, any make, of capacity 1 HP with super enameled copper wire of appropriate size as directed. 10 EACH JOB
48 48 S&F in replacement weld mesh 3”x2” rectangle block of 12 SWG galvanized iron of size 24”x28” in size for side panels of desert coolers all as specified and directed by the Engineer-in-Charge. 10 SET OF THREE
49 49 S&F in repairs front grill made of sheet steel as per sample complete with operating panel board for 4000 cum/hrs capacity of desert cooler including two coats of grey synthetic enamel paint over a coat of red oxide primer complete all as per specified and directed. 10 EACH
50 50 S&F in replacement 15mm external dia PVC distributor assembly with 3 outlets for desert cooler complete all as per specified and directed. 30 EACH
51 51 M&L for patch repair work to unserviceable / corroded portion of bottom tank of Desert cooler with 20 gauge PGI sheet including necessary welding and painting the new surfaces to match with existing surface and leakage testing complete all as per specified and directed. 10 EACH JOB
52 52 S&F in replacement bottom water tank of size 750x750x200mm fabricated out of 18 gauge PGI sheet including nuts, bolts and washers etc complete including painting with one coat of bituminous black paint inside and two coat of grey synthetic enamel paint on outside of tank over a coat of red oxide primer complete all as per specified and directed.. 10 EACH JOB
53 53 S&F in replacement side supporting columns fabricated out of 20 gauges PGI sheet of size 80x80x800 mm including necessary nuts, bolts and washers etc complete including painting with one coat of bituminous black paint inside and two coat of grey synthetic enamel paint on outer surfaces over a coat of red oxide primer complete all as per specified and directed. 30 EACH JOB
54 54 S&F in replacement of desert cooler body of size approx 660 x 660 x 900 mm with and including front grill and three side louver fabricated out of 22 gauge mild steel plain GI sheet and bottom water tank (sump) of size 660x660x200mm deep fabricated out of 20 gauge mild steel plain GI sheet including taking out and reinstallation complete with standard fittings such as PVC pipe for water, electric controls and switch, fan speed regulator, rewiring of fan motor and water lifting pump including fixing and connecting existing cooler fan, electric pump with new 3 core PVC insulated & PVC sheathed cables (min. 3 metre in length). External surfaces shall be spray painted with two coats of approvedsynthetic enamel paint over a coat of red oxide primer and internal surface of body, cooler pump and motor shall be painted with two coats of bituminous paint over a coat of red oxide primer complete all as per sample kept in AGE E/M-II office and all as specified and directed by the Engineer-in-Charge. 5 EACH JOB
55 55 M&L for scraping and removing of old paint of desert cooler body (steel surface) and preparation of steel surfaces including necessary denting/welding/cutting etc and spray painting two coats with smoke grey synthetic enamel paint (Ist quality) over a coat of red oxide primer on outer surface and inner surface i.e. water tank and body, fan mounting blades shall be painted with a coat of anticorrosive black paint over a coat of red oxide primer complete for desert cooler of any size and capacity including writing MES No with white synthetic enamel paint 40 to 50 mm high letters complete all as specified and directed. 5 EACH JOB
56 56 M&L for rewinding of Desert cooler exhaust fan motor cap. 1HP with super enameled copper wire of appropriate size as directed & including replacement of capacitor 25 Mfd 440 volts complete all as per specified and directed. 10 EACH JOB
57 57 .S&F in replacement submersible pump of discharge head 1.5 metre 220-240 volts AC supply single phase 40 watt complete all as per specified and directed. 10 EACH
58 58 S&F in replacement desert Cooler exhaust fan aluminium blade 18" to 24” complete all as per specified and directed. 10 EACH
59 59 Taking down sub main wring/service connection any type/any size including pipe and connecting accessories complete all as per specified and directed. 50 RM
60 60 M&L for in repairs sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 volt grade of size 6 Sqmm and one run of 4 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm, ISI marked concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc. including 2.5 sqmm PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 volt grade as earth wire complete.\nNOTE: Two runs of cable with one run of earth wire and PVC conduit shall be measured & paid for as one length.\n 50 RM
61 61 Supply & Fix sheet metal enclosure with a two pin and earth plug socket complete including with 16 Amps MCB Single pole 240 Volt AC complete all as per specified and directed. 10 Each
62 62 S&F in replacement selector switch with Knob three speed fan motor complete all as per specified and directed. 4 EACH
63 63 S&F in replacement fan blade with bracings, screw, of size 20” desert cooler heavy duty as per duty complete all as per specified and directed. 4 EACH
64 64 S&F in replacement desert cooler fan motor cap. 1 HP three speed 1400 RPM single phase with fan blade stand and selector switch complete all as per specified and directed. 4 EACH
65 65 M&L for painting of desert cooler stand with two coats of synthetic enamel paint of approved colour over a coat of red oxide including preparation old surfaces complete all as specified and directed by Engineer-in-Charge. 10 EACH
66 66 S&F in replacement 3 pin plug top cap 5 Amp AC 240 Volts 50 Hz complete all as per specified and directed.. 5 EACH
67 67 S&F in replacement 3 pin plug top cap 15 Amp AC 240 Volts 50 Hz complete all as per specified and directed.. 5 EACH
68 68 S&F in replacement of main lead 3 core,8 feet length with 3 pin plug top cap 5 Amp AC 240 Volts 50 Hz complete all as per specified and directed. 5 EACH
69 69 S&F in replacement of leg set with gromate for desert cooler any capacity and make as per existing at site and complete all specified and directed by Engineer-in-charge. 5 EACH
70 70 S&F in replacement motor fixing ring for desert cooler eight screw/clip type as per existing at site complete all as specified and directed. 5 EACH
71 71 S&F in replacement of copper wound wire electric motor 1/5 HP capacity for desert cooler make as per existing at site complete all as specified and directed. 10 EACH
72 72 M&L for over load relay 1/3 HP and capacitor 40 to 60 mfd make as per existing at site complete all as specified and directed. 4 EACH
73 73 S&F in replacement of condensor fan motor for Deep freezer 320 ltrs including installation, commissioning, testing etc complete to entire satisfaction of Engineer-in-Charge. 1 EACH