Supply And Installation Of 8 Mtr Mini Mast System With 4 Nos . Of 150W Led Flood Lights At Incholikavu Kavala , Ward 7 In Thalappalam Grama Panchayath Supply And Installation Of 8 Mtr Mini Mast System With 4Nos . Of 150W Led Flood Lights At Incholika
Tender Overview
Project Description
Supply And Installation Of 8 Mtr Mini Mast System With 4 Nos . Of 150W Led Flood Lights At Incholikavu Kavala , Ward 7 In Thalappalam Grama Panchayath Supply And Installation Of 8 Mtr Mini Mast System With 4Nos . Of 150W Led Flood Lights At Incholikavu Kavala , Ward7 In Thalappalam Grama Panchayath
BOQ
| Name of Work:Supply and Installation of 8 mtr Mini Mast System with 4 nos. of 150W LED Flood lights at Incholikavu Kavala,ward 7 in Thalappalam Grama Panchayat | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16mmsuitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4nos existing RCC foundation and junction box etc, complete 8 Meters (90.15.1.1) | BI01010001010000000000000515BI0100001113 | 1 | No |
| 2 | 2 | Supply Conveyance, installation, testing and commissioning of 150W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) (90.15.4.9) | BI01010001010000000000000515BI0100001114 | 4 | Nos |
| 3 | 3 | Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br>Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required.CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used forpanel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame) (90.14.1.2) | BI01010001010000000000000515BI0100001115 | 2 | sqm |
| 4 | 4 | Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet (90.14.3.2) | BI01010001010000000000000515BI0100001116 | 7 | meter |
| 5 | 5 | Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board (90.14.5) | BI01010001010000000000000515BI0100001117 | 10 | kg |
| 6 | 6 | Supply and fixing of 2nos. of 25A Contactor, 63A Connector, 2 nos. of Digital timer, Banana Al. socket, 2.5 sq. mm ISI marked FRLS PVC insulated single core<br>copper conductor cable, HRC fuse base of\n20/32A, 32A 2-way neutral links<br>mounted on DMC/SMC base, OBOR (switching/lightning protection) for single phase<br>protection as required. (od143739/2019_2020) | BI01010001010000000000000515BI0100001118 | 1 | No |
| 7 | 7 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with\nconnections, testing and commissioning etc. as required.25 amps (2.14.1) | BI01010001010000000000000515BI0100001119 | 1 | no |
| 8 | 8 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and netural (2.10.2) | BI01010001010000000000000515BI0100001120 | 1 | No |
| 9 | 9 | Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface /\nrecess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm (90.6.5.11) | BI01010001010000000000000515BI0100001121 | 25 | meter |
| 10 | 10 | Earthing with G.I. earth plate 300 mm X300 mm X 6 mm thick including wateringpipe of 2 metre long etc. with the Fine sand, earthing compound, GI strip all sizes, Galvanised Steel Bolts & Nuts 6mm dia and 25mm long round head with slots etc as required.<br> (od143740/2019_2020) | BI01010001010000000000000515BI0100001122 | 1 | No |
| 11 | 11 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earthelectrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be\ndone by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 6 6.000 (5.9) | BI01010001010000000000000515BI0100001123 | 6 | meter |
| 12 | 12 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. (5.12) | BI01010001010000000000000515BI0100001124 | 6 | meter |
| 13 | 13 | Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling\nthe trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).2 core 10 sq mm (90.12.1.3) | BI01010001010000000000000515BI0100001125 | 6 | meter |
| 14 | 14 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm) (9.1.2) | BI01010001010000000000000515BI0100001126 | 2 | set |
| 15 | 15 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil (2.6.1) | BI01010001010000000000000515BI0100001127 | 1.4 | cum |
| 16 | 16 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40\nnominal size) (4.1.8) | BI01010001010000000000000515BI0100001128 | 0.1 | cum |
| 17 | 17 | Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete (5.9.1) | BI01010001010000000000000515BI0100001129 | 3.7 | sqm |
| 18 | 18 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more as per drawing (5.22.6) | BI01010001010000000000000515BI0100001130 | 30 | kg |
| 19 | 19 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size (5.1.2) | BI01010001010000000000000515BI0100001131 | 0.6 | cum |
| 20 | 20 | 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) (13.1.10) | BI01010001010000000000000515BI0100001132 | 1 | sqm |
| 21 | 21 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. (2.25) | BI01010001010000000000000515BI0100001133 | 0.871 | cum |
| 22 | 22 | Charges for KSEB connection including all laison works (Actual Amount paid on production of receipt). | BI01010001010000000000000515BI0100001134 | 1 | Nos |
| 23 | 23 | Fabrication ,supply, conveyance and installation of Granite name board indicating the cost involved, the commencement, completion and inauguration date etc. (Based on Actuals) | BI01010001010000000000000515BI0100001135 | 1 | Nos |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender