Educational and Research Institute Local Bodies Closing in 0 days TDR #23394086

Supply Of Equipment Of Physics Laboratory

Issued by Local Bodies · ALIPURDUAR, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
04 Feb 2020
0 days left
EMD
20000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
ALIPURDUAR → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Supply Of Equipment Of Physics Laboratory-2 Study Of Electron Spin Resonance-Determine Magnetic Field As A Function Of The Resonance Frequency. 3 Study Of Zeeman Effect: With External Magnetic Field; Hyperfine Splitting. 4 To Verify The Law Of Malus For Plane Polarized Light. Model: Detech -Ml01 5 To Analyze Elliptically Polarized Light By Using A Babinet’S Compensator. Model: Detech-Bc01, Complete With Babinet Compensator, Sodium Lamp, Lamp House, Transformer, Polariser, Analyser, Optical Bench With Riders. 6 To Determine The Wavelength And Velocity Of Ultrasonic Waves In A Liquid ( Kerosene Oil, Xylene, Etc. ) By Studying The Diffraction Through Ultrasonic Grating. Model: Detech-Usw01. Nobjective: N1. To Study The Diffraction Of Light Due To Propagation Of Ultrasonic Wave In A Liquid N2. To Determine The Speed Of Sound In Various Liquids At Room Temperature N3. To Determine The Compressibility Of The Given Liquids. Napparatus: N1. Radio Frequency Oscillator Fitted With A Frequency Meter N2. Quartz Crystal Slab Fitted With Two Leads N3. Spectrometer N4. Glass Cell With Sample Liquid ( Kerosene / Toluene / Turpentine Oil Etc ) N5. Sodium Lamp N6. Spirit Level. 7 To Study Polarization And Double Slit Interference In Microwaves. 8 To Verify The Stefan’S Law Of Radiation And To Determine Stefan’S Constant. Model: Detech –Sbbr Nmeasurement Of Stefans Constant Using Black Body Radiation. Ncomplete With Stefans Conatant Apparatus, Very High Sensitive Light Spot Galvanometer With Sensitivity Control, High Quality Thermocouple.3 Lt Cu Boiler, Rubber Tube, Electrical Heater With Temp. Control. N 9 To Determine The Boltzmann Constant Using V-I Characteristics Of Pn Junction Diode. Model: Detech-Boltz Nthe Apparatus Consists: N ( A ) A Digital Millivoltmeter ( 0 – 9.99 V ) To Measure The Voltage Across The Diode. N ( B ) A Highly Stabilized Power Supply Whose Voltage Can Be Varied In Steps Of 1 Mv Using A Ten – Turn Potentiometer. 10 To Measure The Magnetic Susceptibility Of Solids. Napparatus For The Measurement Of Susceptibility Of Solids By Gouys Method. Nthe Apparatus Consists Of: Na ) Scientific Balance, ( With Weight Box ) Nb ) Al. Samples And Glass Tube For Powder Samples Nc ) Gouy’S Balance Stand Nd ) Electromagnet, Detech Ne ) Constant Current Power Supply, Detech Nf ) Digital Gaussmeter, Detech Ncomplete In All Respect . Make : Detech N 11 To Measure The Dielectric Constant Of A Dielectric Materials With Frequency.Model: Detech-Dc Nto Calculate Dielectric Constant Of Solids. Nthe Instrument Consists Of A High Frequency R.F Oscillator 4Mhz With Outer Gang Condenser, Optimum Tuning Is Indicated On Meter. The Change In Meter Reading After Placing Dielectric Material Between Parallel Plates Can Be Detected And Difference Can Be Noted. Works On 220V Av 50Hz. Ndielectric Constant Experiment Consists Of The Following: N1. Dielectric Constant Apparatus. N2. Variable Gang Capacitor N3. Test Capacitor ( Solid Gang Condenser ) Nthree Types Of Bakalite Sheets For Dielectric Materials Ntwo Set Of Leads N 12 To Determine The Complex Dielectric Constant And Plasma Frequency Of Metal Using Surface Plasmon Resonance ( Spr ) 13 To Draw The Bh Curve Of Fe Using Solenoid & Determine Energy Loss From Hysteresis. Model: Detech - Bhct Nto Draw Bh Curve Of A Fe Using Solenoid And Determine Energy Loss From Hysteresis Nb-H Curve Tracer Nsetup Consists Of Main Unit Having Variable A.C. Supply And Control For Magnetizing Coil, Specially Designed Power Supply For Pickup Probe, I.C. Holder Having Magnetizing Coil And Pickup Probe. Samples Of Different Materials ( 4 Nos. ) . Nadditional Accessory Required : C.R.O. ( Not Supplied ) Nobjective N1. Study Of The Hysteresis Curves Of Transformer Stampings, Ferrites And Other Magnetic Materials Of Different Shapes And Determination Of Their Energy Losses. N2. Study Of The Hysteresis Curve As A Function Of The Magnetic Field. N3. Determination Of Saturation, Magnetization, Reminence And Coercivity Of Magnetic Nmaterials N 14 To Measure The Resistivity Of Semiconductor ( Ge ) With Temperature By Four-Probe Method ( Room Temperature To 1500 C ) And To Determine Its Band Gap. Model : Detech – Bg-S-D Nto Study The Temperature Dependence Of Reverse Saturation Current In A Junction Diode & Hence To Determine The Band Gap Of Semiconductor. Complete With Temp. Controlled Oven, Digital Voltmeter, Digital Micro Ammeter, Dc Regulated Power Supply, Semiconductor, Thermometer, Manual. N 15 To Determine The Hall Coefficient Of A Semiconductor Sample. Ncomplete With The Following : Nhall Probe ( Ge Crystal-N Type ) Nhall Probe ( Ge Crystal-P Type ) Nhall Probe Stand ( Wooden ) Nhall Effect Set Up Detech Nelectromagnet. Detech Nconstant Current Power Supply. Detech Nballistic Galvanometer Nlamp & Scale Nstandard Solenoid Nphol`S Commutator Nrheostat 25 Ohms / 5 A - Heavy Duty N 16 Vacuum Desiccator.

BOQ

Name of Work : SUPPLY OF ITEMS
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11EQUIPMENT OF PHYSICS LABORATORY
21.01Study of Electron spin resonance-determine magnetic field as a function of the resonance frequency.item11Nos
31.02Study of Zeeman effect: with external magnetic field; Hyperfine splitting.item21Nos
41.03To verify the law of Malus for plane polarized light. Model: DETECH -ML01item31Nos
51.04To analyze elliptically polarized light by using a Babinet’s compensator. Model: DETECH-BC01, Complete with Babinet Compensator, Sodium Lamp, lamp house, transformer, Polariser, Analyser, Optical Bench with riders.item41Nos
61.05To determine the wavelength and velocity of ultrasonic waves in a liquid (Kerosene Oil, Xylene, etc.) by studying the diffraction through ultrasonic grating. Model: DETECH-USW01. \nObjective:\n1. To study the diffraction of light due to propagation of ultrasonic wave in a liquid\n2. To determine the speed of sound in various liquids at room temperature\n3. To determine the compressibility of the given liquids.\nApparatus:\n1. Radio frequency oscillator fitted with a frequency meter\n2. Quartz crystal slab fitted with two leads\n3. Spectrometer\n4. Glass cell with sample liquid (kerosene/Toluene/Turpentine oil etc)\n5. Sodium lamp\n6. Spirit level.item51Nos
71.06To study Polarization and double slit interference in microwaves.item61Nos
81.07To verify the Stefan’s law of radiation and to determine Stefan’s constant. Model: DETECH –SBBR\nMeasurement of Stefans constant using black body radiation.\nComplete with Stefans conatant apparatus, very high sensitive light spot galvanometer with sensitivity control, high quality thermocouple.3 lt Cu Boiler, rubber tube, electrical heater with temp. control.\nitem71Nos
91.08To determine the Boltzmann constant using V-I characteristics of PN junction diode. Model: DETECH-BOLTZ\nThe apparatus consists:\n(a) A digital millivoltmeter (0 – 9.99 V) to measure the voltage across the diode.\n(b) A highly stabilized power supply whose voltage can be varied in steps of 1 mV using a ten – turn potentiometer.item81Nos
101.09To measure the Magnetic susceptibility of Solids. \nApparatus for the Measurement of Susceptibility of Solids by Gouys Method. \nThe apparatus consists of:\na) Scientific Balance, (with weight box)\nb) Al. Samples and Glass Tube for powder samples\nc) Gouy’s Balance Stand\nd) Electromagnet, DETECH\ne) Constant Current Power Supply, DETECH\nf) Digital Gaussmeter, DETECH\nComplete in all respect . Make : DETECH\nitem91Nos
111.1To measure the Dielectric Constant of a dielectric Materials with frequency.Model: DETECH-DC\nTo calculate Dielectric Constant of Solids.\nThe instrument consists of a High Frequency R.F Oscillator 4MHz with outer Gang Condenser, optimum tuning is indicated on meter. The change in meter reading after placing Dielectric Material between parallel plates can be detected and difference can be noted. Works on 220V AV 50Hz.\nDielectric Constant Experiment consists of the following:\n1. Dielectric Constant Apparatus.\n2. Variable Gang Capacitor\n3. Test Capacitor ( Solid Gang Condenser)\nThree types of Bakalite sheets for Dielectric materials \nTwo set of leads\nitem101Nos
121.11To determine the complex dielectric constant and plasma frequency of metal using Surface Plasmon resonance (SPR)item111Nos
131.12To draw the BH curve of Fe using Solenoid & determine energy loss from Hysteresis. Model: DETECH - BHCT\nTo draw BH curve of a Fe using solenoid and determine energy loss from hysteresis\nB-H CURVE TRACER \nSetup consists of Main unit having variable a.c. supply and control for magnetizing coil, specially designed power supply for pickup probe, I.C. holder having magnetizing coil and pickup probe. Samples of different materials( 4 nos.).\nAdditional Accessory Required : C.R.O. (Not supplied )\nOBJECTIVE\n1. Study of the hysteresis curves of transformer stampings, ferrites and other magnetic materials of different shapes and determination of their energy losses.\n2. Study of the hysteresis curve as a function of the magnetic field. \n3. Determination of saturation, magnetization, reminence and coercivity of magnetic\nmaterials\nitem121Nos
141.13To measure the resistivity of semiconductor (Ge) with temperature by four-probe method (room temperature to 1500 C ) and to determine its band gap. Model : DETECH – BG-S-D\nTo study the temperature dependence of reverse saturation current in a junction diode & hence to determine the band gap of semiconductor. Complete with Temp. controlled oven, Digital Voltmeter, Digital Micro Ammeter, DC Regulated Power Supply, Semiconductor, Thermometer, manual.\nitem131Nos
151.14To determine the Hall coefficient of a semiconductor sample. \nComplete with the following :\nHall Probe (Ge Crystal-n type) \nHall Probe (Ge Crystal-p type) \nHall Probe Stand (wooden) \nHall Effect Set Up DETECH\nElectromagnet. DETECH\nConstant Current Power Supply. DETECH\nBallistic Galvanometer \nLamp & Scale \nStandard Solenoid \nPhol`s Commutator \nRheostat 25 ohms / 5 A - Heavy duty \nitem141Nos
161.15Vacuum Desiccator.item151Nos

AI Tender Summary

OUR REF NO 23394086
AUTHORITY Local Bodies
TENDER VALUE Ref. Documents
LAST DATE 04-02-2020
Authority
Authority Name Department of Higher Education
Work Description Supply Of Equipment Of Physics Laboratory-2 Study Of Electron Spin Resonance-Determine Magnetic Field As A Function Of The Resonance Frequency. 3 Study Of Zeeman Effect: With External Magnetic Field; Hyperfine Splitting. 4 To Verify The Law Of Malus For Plane Polarized Light. Model: Detech -Ml01 5 To Analyze Elliptically Polarized Light By Using A Babinet’S Compensator. Model: Detech-Bc01, Complete With Babinet Compensator, Sodium Lamp, Lamp House, Transformer, Polariser, Analyser, Optical Bench With Riders. 6 To Determine The Wavelength And Velocity Of Ultrasonic Waves In A Liquid ( Kerosene Oil, Xylene, Etc. ) By Studying The Diffraction Through Ultrasonic Grating. Model: Detech-Usw01. Nobjective: N1. To Study The Diffraction Of Light Due To Propagation Of Ultrasonic Wave In A Liquid N2. To Determine The Speed Of Sound In Various Liquids At Room Temperature N3. To Determine The Compressibility Of The Given Liquids. Napparatus: N1. Radio Frequency Oscillator Fitted With A Frequency Meter N2. Quartz Crystal Slab Fitted With Two Leads N3. Spectrometer N4. Glass Cell With Sample Liquid ( Kerosene / Toluene / Turpentine Oil Etc ) N5. Sodium Lamp N6. Spirit Level. 7 To Study Polarization And Double Slit Interference In Microwaves. 8 To Verify The Stefan’S Law Of Radiation And To Determine Stefan’S Constant. Model: Detech –Sbbr Nmeasurement Of Stefans Constant Using Black Body Radiation. Ncomplete With Stefans Conatant Apparatus, Very High Sensitive Light Spot Galvanometer With Sensitivity Control, High Quality Thermocouple.3 Lt Cu Boiler, Rubber Tube, Electrical Heater With Temp. Control. N 9 To Determine The Boltzmann Constant Using V-I Characteristics Of Pn Junction Diode. Model: Detech-Boltz Nthe Apparatus Consists: N ( A ) A Digital Millivoltmeter ( 0 – 9.99 V ) To Measure The Voltage Across The Diode. N ( B ) A Highly Stabilized Power Supply Whose Voltage Can Be Varied In Steps Of 1 Mv Using A Ten – Turn Potentiometer. 10 To Measure The Magnetic Susceptibility Of Solids. Napparatus For The Measurement Of Susceptibility Of Solids By Gouys Method. Nthe Apparatus Consists Of: Na ) Scientific Balance, ( With Weight Box ) Nb ) Al. Samples And Glass Tube For Powder Samples Nc ) Gouy’S Balance Stand Nd ) Electromagnet, Detech Ne ) Constant Current Power Supply, Detech Nf ) Digital Gaussmeter, Detech Ncomplete In All Respect . Make : Detech N 11 To Measure The Dielectric Constant Of A Dielectric Materials With Frequency.Model: Detech-Dc Nto Calculate Dielectric Constant Of Solids. Nthe Instrument Consists Of A High Frequency R.F Oscillator 4Mhz With Outer Gang Condenser, Optimum Tuning Is Indicated On Meter. The Change In Meter Reading After Placing Dielectric Material Between Parallel Plates Can Be Detected And Difference Can Be Noted. Works On 220V Av 50Hz. Ndielectric Constant Experiment Consists Of The Following: N1. Dielectric Constant Apparatus. N2. Variable Gang Capacitor N3. Test Capacitor ( Solid Gang Condenser ) Nthree Types Of Bakalite Sheets For Dielectric Materials Ntwo Set Of Leads N 12 To Determine The Complex Dielectric Constant And Plasma Frequency Of Metal Using Surface Plasmon Resonance ( Spr ) 13 To Draw The Bh Curve Of Fe Using Solenoid & Determine Energy Loss From Hysteresis. Model: Detech - Bhct Nto Draw Bh Curve Of A Fe Using Solenoid And Determine Energy Loss From Hysteresis Nb-H Curve Tracer Nsetup Consists Of Main Unit Having Variable A.C. Supply And Control For Magnetizing Coil, Specially Designed Power Supply For Pickup Probe, I.C. Holder Having Magnetizing Coil And Pickup Probe. Samples Of Different Materials ( 4 Nos. ) . Nadditional Accessory Required : C.R.O. ( Not Supplied ) Nobjective N1. Study Of The Hysteresis Curves Of Transformer Stampings, Ferrites And Other Magnetic Materials Of Different Shapes And Determination Of Their Energy Losses. N2. Study Of The Hysteresis Curve As A Function Of The Magnetic Field. N3. Determination Of Saturation, Magnetization, Reminence And Coercivity Of Magnetic Nmaterials N 14 To Measure The Resistivity Of Semiconductor ( Ge ) With Temperature By Four-Probe Method ( Room Temperature To 1500 C ) And To Determine Its Band Gap. Model : Detech – Bg-S-D Nto Study The Temperature Dependence Of Reverse Saturation Current In A Junction Diode & Hence To Determine The Band Gap Of Semiconductor. Complete With Temp. Controlled Oven, Digital Voltmeter, Digital Micro Ammeter, Dc Regulated Power Supply, Semiconductor, Thermometer, Manual. N 15 To Determine The Hall Coefficient Of A Semiconductor Sample. Ncomplete With The Following : Nhall Probe ( Ge Crystal-N Type ) Nhall Probe ( Ge Crystal-P Type ) Nhall Probe Stand ( Wooden ) Nhall Effect Set Up Detech Nelectromagnet. Detech Nconstant Current Power Supply. Detech Nballistic Galvanometer Nlamp & Scale Nstandard Solenoid Nphol`S Commutator Nrheostat 25 Ohms / 5 A - Heavy Duty N 16 Vacuum Desiccator.
Basic Detail
Tender No e NIT /APDC 01/ 2019 - 20
Bidding Type Tender
Location
City ALIPURDUAR
State West Bengal
Key Dates
Publish Date 27 Jan 2020
Submission Date 04 Feb 2020
Open Date 07 Feb 2020
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 20000
Exemption Not Available
Document List
Tendernotice_1.pdf
BOQ_492146.xls
715782C8-FE0A-482E-B20C-4D9AC52CD454.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 27, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
Feb 04, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Feb 07, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

xls

BOQ_492146.xls

html

715782C8-FE0A-482E-B20C-4D9AC52CD454.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail