| 1 | 0.01 | Schedule 'A' Section - I(AGE E/M KASAULI) | | | |
|---|
| 2 | 1 | M&L for servicing/ maintenance of Air conditioning, Refrigeration and connected items at Dagshai & Mil Stn Kasauli of any capacity in situ by cleaning of complete external surface, internal surface, trays racks with required chemical solution removing all dirts, strains complete checking serviceability of electrical circuit of unit, thermostat knob, fans if provided in frost free model, relays, thermostat, trays including replacement of unserviceable spares such as relays, thermostat, trays and testing after completion to entire satisfaction of Engr-in-Charge as well as user unit for Make of Refrigerator-Samsang/LG/Blue star/Whirlpool. Note : (i) Spares require for replacement of minor repair as mentioned shall be measured and paid as supply only under appropriate items of this schedule and labour charges shall deemed to be included in the quoted rate of this items. (ii) Items require for Major repair shall be measured and paid as M&L under appropriate items of this schedule and rate shall be exclusive of quoted rate of this items. | | 8 | Each Job |
|---|
| 3 | 2 | Supply only following company recommended spares as per original of refrigerator any cap after dismantling taking out unsv one for make of refrigerator. Make Samsung/ LG/ Bluestar whichever applicable | | | |
|---|
| 4 | 2.01 | Starting relay | | 5 | Each |
|---|
| 5 | 2.02 | Thermostat | | 7 | Each |
|---|
| 6 | 2.03 | Bottle support as per existing make & Model | | 4 | Each |
|---|
| 7 | 2.04 | Chiller trays small as per existing make & model | | 4 | Each |
|---|
| 8 | 2.05 | Sliding trays large as per existing make & model | | 5 | Each |
|---|
| 9 | 3 | Supply & fix new company sealed reciprocating compressor unit for refrigerator Make Samsung/ LG/ Blue star whichever applicable of capacity 190 Ltrs to 321 Ltrs with required nuts, bolts & washers, connecting necessary copper tubings by gas welding/ brazing gas charging with R-134A after dismantling/ taking out existing unserviceable/burnt compressor unit from the regrigerator in wksp and testing after completion to entire satisfaction of Engr-in-Charge and user unit. Note :- (i) Compressor unit shall be 1st quality with compitable model and make of compressor shall be as recommended by the manufacturer of Refrigerator. (ii) Gas charging shall be measured and paid separately under appropriate items of this schedule (iii) Company test certificate and warrantee certificate shall be submitted to dept. | | 8 | Each |
|---|
| 10 | 4 | Supply & Fix new condenser unit refrigerators Make- Samsung/LG/Bluestar whichever applicable of capacity 165 ltrs to 310 ltrs with required nuts, bolts & washers connecting necessary copper tubing by Gas welding/ brazing gas charging with R-134A after dismantling/ taking our existing unserviceable unit from the refrigerator in situ and testing after completion of entire satisfaction of Engr-in-Charge and user unit. Note :- (i) Condenser unit shall be compitable model and make shall be as recommended by the manufacturer of Refrigerator (ii) Gas charging shall be measured separately under appropriate items of this schedule. | | 3 | Each |
|---|
| 11 | 5 | M&L for servicing/ maintenance of Deep Freezer of capacity 200L/310L Make - Blue Star/ LG/ Voltas in situ by cleaning of complete external surface, internal surface, trays, racks with required chemical solution removing all dirts, strains complete and checking serviceability of electrical circuit of unit, relays, thermostat, trays including replacement of unserviceable spares such as relays, capacitors, thermostat, trays and testing after completion to entire satisfaction of Engr-in-Charge as well as user unit. Note :- (i) Spares require for replacement on minor repair as mentioned shall be measured and paid as supply only under appropropriate items of this schedule and labour charges shall deemed to be included in the quoted rate of this item (ii) Items require for major repair shall be measured and paid as M&L under appropriate items of this schedule and rate shall be exclusive of quoated rate of this items. | | 5 | Each Job |
|---|
| 12 | 6 | Supply only following company recommended spares as per original of Deep freezer of cap 200/310 Ltrs suiutable for make. Bluestar/LG/Voltas whichever applicable | | | |
|---|
| 13 | 6.01 | Over load protector | | 3 | Each |
|---|
| 14 | 6.02 | Starting relay | | 2 | Each |
|---|
| 15 | 6.03 | Thermostat | | 3 | Each |
|---|
| 16 | 6.04 | Running capacitor 4 to 25 mfd | | 3 | Each |
|---|
| 17 | 6.05 | Sliding trays small as per existing make & model | | 3 | Each |
|---|
| 18 | 6.06 | Sliding trays large as per existing make & model | | 4 | Each |
|---|
| 19 | 6.07 | PVC fan for blower motor | | 3 | Each |
|---|
| 20 | 7 | Supply & fix new company sealed reciprocating compressor unit with require nuts, bolts & washers, connecting necessary copper tubing by gas welding/ brazing, gas charging with R-134A, replacement of capilary tube and oil filter after dismantling/ taking out existing unserviceable/ burnt compressor unit from the Deep Freezer 200/310 Ltrs capacity and testing after completion to entire satisfaction of Engr-in-Charge and user unit suitable for DF Make- Blue Star/ LG/ Voltas whichever applicable. Note :- (i) Compressor unit shall be 1st quality with compitable model and make of compressor shall be as recommended by the manufacture of DF. (ii) Gas charging shall be measured and paid separately junder appropriate item of this schedule. (iii) Company test certificate and warrantee certificate shall be submitted to dept. | | 5 | Each |
|---|
| 21 | 8 | Supply and Fix condenser coil unit of Deep freezer 200/310 Ltrs as per existing make and competable model, connecting necessary copper tubing by gas welding, gas charging with R-134A after dismantling/ taking out existing unserviceable condenser unit and testing after completion to entire satisfaction of Engr-in-Charge and user unit suitable for DF Make- Blue star/ LG/ Voltas whichever applicable. Note :- (i) Gas charging shall be measured and paid separately under appropriate items of this schedule. | | 2 | Each |
|---|
| 22 | 9 | M&L for refrigerant gas charging for deep freezer with R-134A gas after proper cleaning of pipe lines with carbon tetra and flushing with Nitrogen, complete leakage test, including replacement of liquid line filter capillary tube, required soldering/ brazing/ gas welding to attaining proper level to entire satisfaction of Engr-in-Charge and user unit for 200L/310L deep freezer unit. | | 10 | Each |
|---|
| 23 | 10 | M&L for refrigerant gas charging for deep refrigerator with R-134A gas after proper cleaning of pipe lines with carbon tetra and flushing with Nitrogen, complete leakage test, including replacement of liquid line filter capillary tube, required soldering/ brazing/ gas welding to attaining proper level to entire satisfaction of Engr-in-Charge and user unit for 190L/321L Refrigerator Unit. | | 8 | Each |
|---|
| 24 | 11 | Taking out old unsv and Supply and Fixing voltage stabilizer for automatic operation single phase naturally air cooled type & designed for input variation between 170V to 250V with output voltage stabilizer at 230V with accuracy of +-2.5% and of capacity 2 KVA complete all as specified and directed. Make : V-Guard/ APLAB/ANDREW YULE/AE | | 2 | Each |
|---|
| 25 | 12 | Servicing of Window/ Split type AC 1.5/2 TR capacity any make including cleaning the condensing and evaporate coil with the help of descaling solution & water greasing and oiling the blower motor and refixing the same in position after servicing complete all as specified and directed by Engr-in-Charge | | 3 | Each Job |
|---|
| 26 | 13 | M&L in replacement of starting replay suitable for 1.5/2 TR capacity window split type AC including connections all as specified and directed by Engineer-in-Charge. Make - SHRI RAM/ RENUTROI/ KELTRON | | 2 | Each |
|---|
| 27 | 14 | M&L in replacement of starting capacitor 80-100 mfd suitable for 1.5/2 TR Window/ Split type AC all as specified and directed by Engr-in-Charge. Make :- EPCOS/ SARDA/TESLA/ASIAN | | 3 | Each |
|---|
| 28 | 15 | M&L in replacement of Air Filter pad suitable for Window type AC 1.5/2.0 TR capacity all as per specified and directed by Engineer-in-Charge. | | 2 | Each |
|---|
| 29 | 16 | M&L in replacement overload protector suitable for 1.5/2.0 TR Window/ Split type AC including connections all as specified and directed by Engineer-in-Charge. Make :- SRIRAM/RANUTRAL/ KELTRON | | 2 | Each |
|---|
| 30 | 17 | M&L in replacement of running capacitor 36/45 Mfd suitable for 1.5/2.0 TR capacity Window/ Split type AC all as specified and directed by Engineer-in Charge. Make :- EPCOS/ TESLA/SARDA/ASIAN | | 2 | Each |
|---|
| 31 | 18 | M&L in replacement of selector switch/ Knob suitabe for Window type AC 1.5/2.0 TR capacity all as specified and directed by Engineer-in-Charge. Make :- AGI/UNIQUE | | 2 | Each |
|---|
| 32 | 19 | M&L for disconnection and taking down of blower motor suitable for window type AC 1.5/2.0 TR capacity, rewinding with supper enameled copper including wire as existing guage including replacement of bushes and refixing the same complete all as specified and directed by Engeer-in-Charge | | 2 | Each Job |
|---|
| 33 | 20 | All as per item No 19 here in above but suitable for 1.5/2.0 TR split type AC. | | 2 | Each Job |
|---|
| 34 | 21 | Supply and charging of R-22/R-134A as exiting refrigerant in Window/ Split type AC 1.5/2.0 TR capacity including cleaning the Gas system with anticorrosive solution and charging the refrigerant with anti most substances, strainer and rectification of leakages and replacement of filter and copper capillary complete all as specified and directed by Engineer in Charge | | 2 | Each Job |
|---|
| 35 | 22 | Dismantling of old unserviceable sealed compressor of 1.5/2.0 TR capacity Window type AC and S&F new sealed compressor including soldering of copper pipe, cleaning the refrigerant system, rectification of leakage, charging of refrigerant, rubber pads for foundation, nuts & bolts etc and Testing the compressor all as specified and directed by Engineer-in-Charge. Make :- Kirloskar/ Tecumesh | | 2 | Each |
|---|
| 36 | 23 | All as per item No 22 here in above but suitable for 1.5/2.0 TR split type AC. | | 2 | Each |
|---|
| 37 | 24 | M&L for painting of bottom tray of Window type AC of any capacity with black Japan anti corrosive paint in side and out side complete all as specified and directed by Engineer -in-Charge | | 3 | Each Job |
|---|
| 38 | 25 | M&L for Writing of MES No/SM No/ Make Srl No on Window type AC/Water Cooler/ Refrigerator/ Deep freezer with white synthetic enamel paid 2\" high all as specified and directed by Engineer-in-Charge | | 6 | Each Job |
|---|
| 39 | 26 | Schedule 'A' Section - I(AGE E/M Subathu) | | | |
|---|
| 40 | 27 | Taking out the defective compressor of refrigerator of capacity 165 to 185 ltrs from machine after disconnecting the electrical connection and from refrigerant line complete all as specified and as directed. | | 2 | Each |
|---|
| 41 | 28 | All as per item No. 27 above but of refrigerator of capacity 285 to 310 ltrs. | | 1 | Each |
|---|
| 42 | 29 | Supply and fixing hermetically sealed compressor suitable for refrigerator of capacity 165 to 185 ltrs (1/8th HP) and charging of R-12/22/134(a) gas to the refrigerant system upto required quantity including testing of compression of compressor to build up the pressure as per manufacturer's specification including refixing and testing complete all as directed, Make : Kelvinator / Voltas / LG / Whirpool / Techums / Kirloskar. Note : Refrigerant gas additionally if required will be measured and paid separately. | | 2 | Each |
|---|
| 43 | 30 | All as per item No. 29.00 above but of refrigerator of capacity 285 to 310 ltrs (1/6th HP) . | | 1 | Each |
|---|
| 44 | 31 | Supply & charging of R-12/22/134 (a) /410 gas to the refrigerant system upto required quantity including testing of compression of compressor to build up the pressure as per manufacturer's specification | | 18 | kG |
|---|
| 45 | 32 | Supply and fixing thermostat switch of refrigerator of any capacity after taking out old unserviceable item complete all as directed. | | 2 | Each |
|---|
| 46 | 33 | Supply and fixing pigmy lamp 15 watt suitable for refrigerator of any capacity after taking out old unserviceable item complete all as directed. | | 4 | Each |
|---|
| 47 | 34 | Supply and fixing lamp holder with lamp case cover suitable for refrigerator of any capacity after taking out old unserviceable item complete all as directed. | | 3 | Each |
|---|
| 48 | 35 | Supply and fixing open type relay of refrigerator of capacity 165 to 185 ltrs after taking out old unserviceable item complete all as directed. | | 2 | Each |
|---|
| 49 | 36 | All as per item No. 35.00 above but of refrigerator of capacity 285 to 310 ltrs. | | 3 | Each |
|---|
| 50 | 37 | Supply and fixing over load protector of refrigerator of capacity 165 to 185 ltrs after taking out old unserviceable item complete all as directed. | | 3 | Each |
|---|
| 51 | 38 | All as per item No. 37.00 above but of refrigerator of capacity 285 to 310 ltrs. | | 3 | Each |
|---|
| 52 | 39 | Supply and fixing compact box type relay of OLP suitable for refrigerator of capacity 165 to 185 ltrs after taking out old unserviceable item complete all as directed. | | 2 | Each |
|---|
| 53 | 40 | All as per item No. 39.00 above but of refrigerator of capacity 285 to 310 ltrs. | | 3 | Each |
|---|
| 54 | 41 | Supply and fixing of ice tray suitable for 165 to 185 ltrs capacity refrigerator as per sample including taking out old unserviceable item complete all as directed. | | 6 | Each |
|---|
| 55 | 42 | All as per item No. 41.00 above but of refrigerator of capacity 285 to 310 ltrs. | | 4 | Each |
|---|
| 56 | 43 | Supply and fixing of vegetable tray suitable for 165 to 185 ltrs capacity refrigerator as per sample including taking out old unserviceable item complete all as directed. | | 4 | Each |
|---|
| 57 | 44 | All as per item No. 43.00 above but of refrigerator of capacity 285 to 310 ltrs. | | 2 | Each |
|---|
| 58 | 45 | Supply and fixing of chillar tray suitable for 165 to 185 ltrs capacity refrigerator as per sample including taking out old unserviceable item complete all as directed. | | 1 | Each |
|---|
| 59 | 46 | All as per item No. 45.00 above but of refrigerator of capacity 285 to 310 ltrs. | | 2 | Each |
|---|
| 60 | 47 | Supply and fixing of cooling door suitable for 165 to 185 ltrs capacity refrigerator as per sample including taking out old unserviceable item complete all as directed. | | 2 | Each |
|---|
| 61 | 48 | Supply and fixing of cooling door suitable for 285 to 310 ltrs capacity refrigerator as per sample including taking out old unserviceable item complete all as directed. | | 2 | Each |
|---|
| 62 | 49 | Supply and fixing of bottle tray (as per sample) suitable for 165 to 185 ltrs capacity refrigerator including taking out old unserviceable item complete all as directed. | | 6 | Each |
|---|
| 63 | 50 | All as per item No. 50.00 above but of refrigerator of capacity 285 to 310 ltrs. | | 8 | Each |
|---|
| 64 | 51 | Supply, installation and testing of 210 ltr capacity compressor sealed unit for deep freezer (Make: Techum / kirloskar / carrier) after taking out old unserviceable item all as specified and as directed. | | 2 | Each |
|---|
| 65 | 52 | Dismantling of unserviceable fan motor from the deep freezer of 210 ltr capacity and re-winding of fan motor with appropriate gauge of super enameled copper conductor wire to match with the existing gauge including replacement of ball bearing, bush, capacitor including overhauling, testing and re-fixing complete all as specified and as directed. | | 2 | Each |
|---|
| 66 | 53 | Supply and fixing blower motor blade of deep freezer to match with the existing after taking out old worn out unserviceable item all as specified and as directed | | 2 | Each |
|---|
| 67 | 54 | Supply and fixing including commissioning rotary scroll type compressor suitable for window type A/C of capacity 1.5 TR (4500 K CAL / Hr) and testing complete all as specifeid and as directed, Make : Techums / Kirloskar / Carrier / Voltas / LG / Whirpool. | | 4 | Each |
|---|
| 68 | 55 | Material and labour for rewinding of fan motor of window type A/C of capacity 1.5 TR with approved quality super enamelled copper wire of existing guage including replacement of ball bearing, bush etc. heat vernishingand refixing after repair and testing complete all as specifeid and as directed. | | 2 | Each |
|---|
| 69 | 56 | Supply and fixing new fan motor of window type A/C of capacity 1.5 TR as per existing shape and size including replacement of old unserviceable item complete all as specifeid and as directed. | | 1 | Each |
|---|
| 70 | 57 | Supply and fixing starting capacitor, paper impregnated of capacity 80-100 MFD, A.C. 240 volt (Make : Universal / Sarda / Usha) after taking out old unserviceable item all as specified and as directed. | | 6 | Each |
|---|
| 71 | 58 | M & L selector switch rotary / push button as per the existing shape and size suitable for window type A/C of any capacity including taking out of old u/s item all as specified and as directed. | | 3 | Each |
|---|
| 72 | 59 | M & L relay AC 230 volt single phase suitable for window type of any capacity (Make : Ranutrol / Shriram / AE) including taking out old unserviceable item all as specified and as directed. | | 3 | Each |
|---|
| 73 | 60 | M & L over load protector AC 230 volt single phase suitable for window type of any capacity (Make : Ranutrol / Shriram / AE) including taking out old unserviceable item all as specified and as directed. | | 3 | Each |
|---|
| 74 | 61 | M & L air filter suitable for window type A/C of any capacity including taking out old unserviceable item all as specified and as directed. | | 6 | Each |
|---|
| 75 | 62 | M & L fan motor capacitor 8 MFD suitable for window type A/C of any capacity including taking out old unserviceable item all as specified and as directed. | | 2 | Each |
|---|
| 76 | 63 | M & L fan blade suitable for window type A/C of any capacity including taking out old unserviceable item all as specified and as directed. | | 2 | Each |
|---|
| 77 | 64 | M & L front grill suitable for window type A/C of any capacity as per sample including taking out old unserviceable item all as specified and as directed. | | 2 | Each |
|---|
| 78 | 65 | Material and labour for servicing of window type AC of capacity 1.5 after taking out carefully of complete unit from its original position, removing dust form blower, cleaning complete unit thoroughly with cleaning materials as per manufacturer guide line and refixing the same in its original position and testing complete all as specife and as directed. | | 8 | Each |
|---|
| 79 | 66 | Material and labour for servicing of window type AC/ split of capacity 2 ton after taking out carefully of complete unit from its original position, removing dust form blower, cleaning complete unit thoroughly with cleaning materials as per manufacturer guide line and refixing the same in its original position and testing complete all as specife and as directed. | | 6 | Each |
|---|
| 80 | 67 | Taking out worn-out and corroded portion of Air conditioner body / base and fabricating and welding where necessary by cutting, bending, welding, machining etc. of existing PGI / MS sheets of thickness not less than 1.2 mm to bring back the original shape as and where necessary suitable for existing design conditions including painting by two coat of synthetic enamel paint over a coat of red oxide primer all as directed. | | 1 | Each |
|---|
| 81 | 68 | Supply and fixing running capacitor, paper impregnated of capacity 80-100 MFD, A.C. 240 volt (Make : Universal / Sarda / Usha) after taking out old unserviceable item all as specified and as directed. | | 4 | Each |
|---|
| 82 | 69 | Amount of credit of Rs. 15492.00 for retrived old material as mentioned in Schedule 'A' section-II of tender document in pdf form, will be deducted offline while acceptence of tender. | | | |
|---|