| 1 | 1 | Appendix-A | BI01010001010000000000000515BI0100001113 | | |
|---|
| 2 | 1.01 | 15.2.2 : Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 leaner mix ( including equivalent design mix) | BI01010001010000000000000515BI0100001114 | 3.096 | cum |
|---|
| 3 | 1.02 | 16.60.1 : Manufacturing, supplying and fixing retro reflective overhead signage boards made up of 2 mm thick aluminimum sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type - lll of ASTM-D-4956-01 as approved by Engineer-in-Charge, letters, borders etc. as per IRC: 67-2001 in silver white with blue colour back ground and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class ll of ASTM -D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized aluminimum alloys, rivets or bolts & nuts @ 300 mm centre to centre all along the periphery as well as in two vertical rows along with theft resistant measures, including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminimum sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specification and direction of the Engineer-in-Charges. (Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment ).Overhead informatory road signage | BI01010001010000000000000515BI0100001115 | 3 | sqm |
|---|
| 4 | 1.03 | 15.3 : Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. | BI01010001010000000000000515BI0100001116 | 0.327 | cum |
|---|
| 5 | 1.04 | 15.23.2 : Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles above 25 mm and up to 40 mm | BI01010001010000000000000515BI0100001117 | 4.688 | sqm |
|---|
| 6 | 1.05 | od43288/2019_2020 : Laterate masonry with neatly dressed laterate stone of size30x20x20cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc. | BI01010001010000000000000515BI0100001118 | 3.823 | cum |
|---|
| 7 | 1.06 | od46211/2019_2020 : Laterate masonry with neatly dressed laterate stone of size 30x20x20 cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. | BI01010001010000000000000515BI0100001119 | 3.04 | cum |
|---|
| 8 | 1.07 | 5.2.2 : Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) | BI01010001010000000000000515BI0100001120 | 0.379 | cum |
|---|
| 9 | 1.08 | 5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more | BI01010001010000000000000515BI0100001121 | 30.32 | kilogram |
|---|
| 10 | 1.09 | 5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform | BI01010001010000000000000515BI0100001122 | 5.44 | sqm |
|---|
| 11 | 1.1 | 4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) | BI01010001010000000000000515BI0100001123 | 4.469 | cum |
|---|
| 12 | 1.11 | 14.43 : Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. | BI01010001010000000000000515BI0100001124 | 1828.57 | sqm |
|---|
| 13 | 1.12 | 14.53.1 : Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:One or more coats on old work | BI01010001010000000000000515BI0100001125 | 3339.76 | sqm |
|---|
| 14 | 1.13 | 14.54.1 : Painting with synthetic enamel paint of approved brand and manufacture of required colour to an give even shade:One or more coats on old work | BI01010001010000000000000515BI0100001126 | 347.388 | sqm |
|---|
| 15 | 1.14 | 50.9.15.1 : Supplying and fixing 200 mm Aluminium aldrop | BI01010001010000000000000515BI0100001127 | 6 | no |
|---|
| 16 | 1.15 | 50.9.15.3 : Providing and fixing iron hooks and eyes : 200mm. | BI01010001010000000000000515BI0100001128 | 4 | no |
|---|
| 17 | 1.16 | 14.5.1 : Renewing glass panes, with putty and nails wherever necessary including racking out the old putty :Float glass panes of thickness 4 mm | BI01010001010000000000000515BI0100001129 | 1.528 | sqm |
|---|
| 18 | 1.17 | 14.40.2 : Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete.100x70x4 mm (ordinary type) | BI01010001010000000000000515BI0100001130 | 4 | no |
|---|
| 19 | 1.18 | 17.32.3 : Providing and fixing mirror of superior glass ( of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Oval shape 450x350 mm (outer dimensions) | BI01010001010000000000000515BI0100001131 | 4 | each |
|---|
| 20 | 1.19 | 50.9.3.1 : Providing and fixing paneled or paneled and glazed shutters for doors, windows and clerestory windows, 30 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding paneling which will be paid for separately, all complete as per direction 0f Engineer in- charge. using Anjili/ Jack wood | BI01010001010000000000000515BI0100001132 | 11.29 | sqm |
|---|
| 21 | 1.2 | 50.9.4.1 : Providing and fixing paneling or paneling and glazing in paneled or paneled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured) paneling for paneled or paneled and glazed shutters 25 mm to 40 mm thick using good quality Anjili/ Jack wood | BI01010001010000000000000515BI0100001133 | 5.88 | sqm |
|---|
| 22 | 1.21 | 13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) | BI01010001010000000000000515BI0100001134 | 16.353 | sqm |
|---|
| 23 | 1.22 | 50.14.1.2 : Removing and refixing window shutters after necessary repairs for easy opening and closing etc complete as per the direction of site Engineer-in-charge | BI01010001010000000000000515BI0100001135 | 4 | each |
|---|
| 24 | 1.23 | 50.17.1.4 : Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. | BI01010001010000000000000515BI0100001136 | 5 | no |
|---|
| 25 | 1.24 | 50.18.7.2.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with claps at 1.00 metre spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 20 mm dia 12Kgf/cm2 - Internal work - Exposed on wall | BI01010001010000000000000515BI0100001137 | 10 | metre |
|---|
| 26 | 1.25 | 50.18.7.4.2 : Providing and fixing PVC, pipes fittings including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 6 Kgf/cm2 - internal work- Exposed on wall | BI01010001010000000000000515BI0100001138 | 10 | metre |
|---|
| 27 | 1.26 | 50.18.7.6.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall | BI01010001010000000000000515BI0100001139 | 20 | metre |
|---|
| 28 | 1.27 | 50.18.9.9.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2 | BI01010001010000000000000515BI0100001140 | 15 | metre |
|---|
| 29 | 1.28 | od43289/2019_2020 : Providing and fixing C.P. brass shower arm45 cm long | BI01010001010000000000000515BI0100001141 | 5 | each |
|---|
| 30 | 1.29 | 17.73.1 : Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm. weighing not less than 170 gms | BI01010001010000000000000515BI0100001142 | 6 | no |
|---|
| 31 | 1.3 | 17.19.1 : Providing and fixing controlled flush, low level cistern made of vitreous china with all fittings complete.10 litre (full flush) capacity- white | BI01010001010000000000000515BI0100001143 | 2 | each |
|---|
| 32 | 1.31 | od66270/2018_2019 : Supplying and fixing CP Tap 20 mm dia long body including all charges etc complete | BI01010001010000000000000515BI0100001144 | 10 | each |
|---|
| 33 | 1.32 | 17.10.1.4 : Kitchen sink with drain board510x1040 mm bowl depth 178 mm | BI01010001010000000000000515BI0100001145 | 2 | each |
|---|
| 34 | 1.33 | 12.50 : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. | BI01010001010000000000000515BI0100001146 | 10.8 | sqm |
|---|
| 35 | 1.34 | 9.48.1 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding | BI01010001010000000000000515BI0100001147 | 369.375 | kg |
|---|
| 36 | 1.35 | 10.16.2 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes | BI01010001010000000000000515BI0100001148 | 248.194 | kg |
|---|
| 37 | 1.36 | od43125/2019_2020 : Suppying laying and joining 150mm P.V.C drain. | BI01010001010000000000000515BI0100001149 | 6 | metre |
|---|
| 38 | 1.37 | od43126/2019_2020 : Suppying laying and joining 150mm P.V.C drain Drip including all cost and onveyance of materials and labour chages etc?.. Complete. | BI01010001010000000000000515BI0100001150 | 2 | each |
|---|
| 39 | 1.38 | 8.2.2.1 : Granite of any colour and shadeArea of slab upto 0.50 sqm | BI01010001010000000000000515BI0100001151 | 8.51 | sqm |
|---|
| 40 | 1.39 | 11.37A : Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS :\n15622 (thickness to be specified by the manufacturer ) of approved make in all\ncolours, shades except burgundy, bottle green, black of any size as approved\nby Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick\nbed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement\nslurry @ 3.3kg per sqm including pointing in white cement mixed with pigment\nof matching shade complete.Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS :15622 (thickness to be specified by the manufacturer ) of approved make in allcolours, shades except burgundy, bottle green, black of any size as approvedby Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thickbed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cementslurry @ 3.3kg per sqm including pointing in white cement mixed with pigmentof matching shade complete. | BI01010001010000000000000515BI0100001152 | 7.35 | sqm |
|---|
| 41 | 1.4 | 11.36 : Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. | BI01010001010000000000000515BI0100001153 | 7.325 | sqm |
|---|
| 42 | 2 | Appendix B Re tarring of Rest House Roads | BI01010001010000000000000515BI0100001154 | | |
|---|
| 43 | 2.01 | 5.2.a : Providing and applying tack coat with bitumen emulsion( RS) using emulsion pressure distributor at the rate of 0.20 - 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom.Providing and applying tack coat with bitumen emulsion( RS) using emulsion pressure distributor at the rate of 0.20 - 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom. | BI01010001010000000000000515BI0100001155 | 932.065 | sqm |
|---|
| 44 | 2.02 | 5.9.1.a : Providing, laying and rolling of open - graded premix surfacing of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates using Viscosity Grade paving Bitumen( VG -30) to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable HMP of appropriate capacity not less than 75 tonnes/hour, laying and rolling with a smooth wheeled roller 8-10 tonne capacity, finished to required level and grades.Providing, laying and rolling of open - graded premix surfacing of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates using Viscosity Grade paving Bitumen( VG -30) to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable HMP of appropriate capacity not less than 75 tonnes/hour, laying and rolling with a smooth wheeled roller 8-10 tonne capacity, finished to required level and grades. | BI01010001010000000000000515BI0100001156 | 932.065 | sqm |
|---|
| 45 | 2.03 | 5.10.1.a : Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using crushed stone chipping of 6.7 mm size and bitumen (VG-30) @ 9.8 kg per 10 sqmProviding and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using crushed stone chipping of 6.7 mm size and bitumen (VG-30) @ 9.8 kg per 10 sqm | BI01010001010000000000000515BI0100001157 | 932.065 | sqm |
|---|