Military Engineer Services-MES has published Special Repairs To Building No T02 Offrs Mess Of 1 Sikh Li , Spl Repair To Construction Of Hard Standing In Front Of Transist Offrs Accnoffrs Mess Gate Of 1Sikh Li , Spl Repairs To Building No T12 Of Sikh Li And Spl Repair Rewiring And Replacement Of. Submission Date for this Tender is 08-02-2020. Electrification Work Tenders in Gulmarg Jammu And Kashmir. Bidders can get complete Tender details and download the document.
NAME OF WORK : SPL REPAIRS TO BLDG NO T-02 (OFFRS MESS) OF 1 SIKH LI,SPL REPAIR TO CONSTRUCTION OF HARD STANDING IN FRONTOF TRANSIST OFFRS ACCN/OFFRS MESS GATE OF 1SIKH LI,SPL REPAIRS TO BUILDING NO T-12 OF SIKH LI AND SPLREPAIR REWIRING AND REPLACEMENT OF ELECTRICALFITTINGS AND FIXTURE IN BLDG NO T-5, T-6, T-7,T-26A, T-36, T-45, T-56, T-65, T-68B, T-69B AND ENGR LIVING OF 1 ST SIKH LI AT GULMARG. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Demolition of cement concrete(un reinforced) in ground floors and paving not exceeding 15 cm thickness (above or ground level). Complete all as specified and directed by Engineer-In-Charge. | item1 | 2.44 | Cum |
2 | 2 | Dismantling wall/ceiling board any thickness incl cover fillets. Complete all as specified and directed by Engineer-In-Charge. | item2 | 615 | Sqm |
3 | 3 | Demolition of brick work or stone/boulder masonry, built in cement mortar including all quions, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles. Complete all as specified and directed by Engineer-In-Charge. | item3 | 3.42 | Cum |
4 | 4 | M&L for walling of random rubble, un coursed, well bonded, bedded and solidly hearted built in CM 1:6. Complete all as specified and directed by Engineer-In-Charge. | item4 | 3.42 | Cum |
5 | 5 | M&L for 6 mm thick (5 Nos ply) Veneered decorative plywood grade 1 (with BWR resin) with decorative face, one faces veneers only fixed with nails to timber frame work as in lining. Complete all as specified and directed by Engineer-In-Charge. | item5 | 455 | Sqm |
6 | 6 | M&L for 6 mm thick (5 Nos ply) Veneered decorative ply wood. Grade 1 (with BWR resin) with decorative face veneers on only one faces fixed with nails to timber frame work in ceiling. Complete all as specified and directed by Engineer-In-Charge. | item6 | 160 | Sqm |
7 | 7 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) , removing serveciable tiles to store and rubbish off the premises including preparation of dismantled surface to receive tiles, Complete all as specified and directed by Engineer-In-Charge. | item7 | 110 | Sqm |
8 | 8 | Dismantling of plain or corrugated steel sheeting any guage thickness including Nainital or similar pattern in roof covering. Complete all as specified and directed by Engineer-In-Charge. | item8 | 215.5 | Sqm |
9 | 9 | S&F CGI sheet 0.63 mm thick with two corrugation side lap fixed with coach screws and washer in roofs with zinc coating grade 275. Complete all as specified and directed by Engineer-In-Charge. | item9 | 177 | Sqm |
10 | 10 | S&F PGI sheet 0.80 mm thick as in ridges, hips valley gutters, drip and straight flashing fixed with coach screws, washer and zinc coating grade 275. Complete all as specified and directed by Engineer-In-Charge. | item10 | 23.5 | Sqm |
11 | 11 | All as per item No.10 above but except sheets. | item11 | 15 | Sqm |
12 | 12 | Taking down chowkats or frames not exc 1.5 sqm with shutters (without taking off shutters from the frames). Complete all as specified and directed by Engineer-In-Charge. | item12 | 20 | Each |
13 | 13 | All as per item No.12 above but exc 1.5 sqm and not exc 4.00 sqm each. | item13 | 15 | Each |
14 | 14 | Dismantling boarding, any description fixed in any position. Complete all as specified and directed by Engineer-In-Charge. | item14 | 315 | Sqm |
15 | 15 | S & F second class soft wood weather boarding, clean sawn, plain, 20mm thick or feather edged 15mm to 20mm thick and fixed with 30mm laps. Complete all as specified and directed by Engineer-In-Charge. | item15 | 167 | Sqm |
16 | 16 | M&L for 2nd class soft wood 20 mm thick in facia boarding fixed with nails in any situation planed one side with butt joints. Complete all as specified and directed by Engineer-In-Charge. | item16 | 24 | Sqm |
17 | 17 | M&L for preparation of new surface of wood and wood based materials of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer. Complete all as specified and directed by Engineer-In-Charge. | item17 | 246 | Sqm |
18 | 18 | M&L for applying two coats of varnish on wooden ply woods and wood based materials of any description not otherwise described over 10 cm width or girth, over a coat of wood filler coat. Complete all as specified and directed by Engineer-In-Charge. | item18 | 615 | Sqm |
19 | 19 | S&F anodised aluminium frame for door, windows, ventilators with one or more rebates including joining cleat for fixing etc, including powder coating (minimum thickness of powder coating 50 micron). Complete all as specified and directed by Engineer-In-Charge. | item19 | 75 | Kg |
20 | 20 | S&F anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised snap beading screws, etc. Complete all as specified and directed by Engineer-In-Charge. | item20 | 12 | Sqm |
21 | 21 | S & F anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap biading, screw, anodised aluminium fittings such as peg stays 150mm long (1 Nos), hinges type B-21 100mm long (2 Nos) suitable handle (1 Nos), Complete all as specified and directed by Engineer-In-Charge. | item21 | 10 | Sqm |
22 | 22 | S&F 4.00mm thick figured glass, pin head type and glazing with oil putty in squares not exc 0.5 Sqm in each pane. Complete all as specified and directed by Engineer-In-Charge. | item22 | 9.5 | Sqm |
23 | 23 | S&F 4.00mm thick figured glass, pin head type and glazing with oil putty in squares exc 0.5 Sqm in each pane. Complete all as specified and directed by Engineer-In-Charge. | item23 | 5 | Sqm |
24 | 24 | S&F 4.00 mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane. Complete all as specified and directed by Engineer-In-Charge. | item24 | 5.8 | Sqm |
25 | 25 | M&L for 2nd class hard wood 35mm thick glazed and skelton shutters, open rebated and prepared to receive glass, gauge etc (with out sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass. Complete all as specified and directed by Engineer-In-Charge. | item25 | 12.94 | Sqm |
26 | 26 | M&L for 2nd class hard wood 35mm thick plain framed, panelled shutter (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces, the size of rail and stile as per IS: 1003 (Part-I), kiln seasoned and chemically pressure treated. Complete all as specified and directed by Engineer-In-Charge. | item26 | 5.27 | Sqm |
27 | 27 | Dismantling timber scantling 40 sq cm over in section in any positoin framed or unframed work. Complete all as specified and directed by Engineer-In-Charge. | item27 | 9.5 | Cum |
28 | 28 | M&L for second class soft wood clean sawn as in scantling in framed work. Complete all as specified and directed by Engineer-In-Charge. | item28 | 8.7 | Cum |
29 | 29 | All as per item no. 28 above but except timber. | item29 | 0.8 | Cum |
30 | 30 | Dismantling timber scantling as in fillets rails, posts, purlins etc under 40 sq cm in section in framed work. Complete all as specified and directed by Engineer-In-Charge. | item30 | 425 | RM |
31 | 31 | M&L for plain fillets of 2nd class soft wood, square, rectangular or triangular in section clean sawn sectional area exc 13 sqcm & not exc 25 sqcm. Complete all as specified and directed by Engineer-In-Charge. | item31 | 425 | RM |
32 | 32 | M&L for plain fillets of 2nd class soft wood, square, rectangular or triangular in section clean sawn sectional area not exc 3 Sqcm. Complete all as specified and directed by Engineer-In-Charge. | item32 | 210 | RM |
33 | 33 | M&L for plain fillets of 2nd class soft wood, square, rectangular or triangular in section clean sawn sectional area exc 6 sqcm and not exc 13 sqcm. Complete all as specified and directed by Engineer-In-Charge. | item33 | 140 | RM |
34 | 34 | M&L for providing plain cement concrete 1:3:6 type C-1, 50mm thick using 20 mm graded stone aggregate as in plinth protection/path finishing the surface even and smooth without using extra cement. Complete all as specified and directed by Engineer-In-Charge. | item34 | 47 | Sqm |
35 | 35 | M&L for preparation of new surfaces of steel and iron surface of any description, not otherwise descriped over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide. Complete all as specified and directed by Engineer-In-Charge. | item35 | 225.58 | Sqm |
36 | 36 | M&L for preparing new zinc or galvanised surfaces to receive paint, by coating with mordant solution including washing and cleaning. Complete all as specified and directed by Engineer-In-Charge. | item36 | 225.58 | Sqm |
37 | 37 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick (Square/Rectangular) area of each tile exceeding 0.18Sqm but not exc 0.38 Sqm, in floors etc. Set and jointed in neat slurry and pointed in white or coloured match, on 15mm thick screed bed CM 1:4. Complete all as specified and directed by Engineer-In-Charge. | item37 | 15 | Sqm |
38 | 38 | M&L for glazed ceramic coloured tiles in vertical surface 350x250x7mm/450x350x7mm thick set and jointed in neat slurry and pointed in white or colour cement to match, incl 10mm thick plastering in CM 1:4, Complete all as specified and directed by Engineer-In-Charge. | item38 | 33 | Sqm |
39 | 39 | M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigments to match the shade of the slab including rubbing and polishing on 20mm screed bed in CM 1:4. Complete all as specified and directed by Engineer-In-Charge. | item39 | 27 | Sqm |
40 | 40 | S&F vitrified ceramic tiles 10mm thick light shade(square/rectangular) polished, area of each tiles exc 0.36 sqm but not exc 0.42 Sqm, in floors etc,set and jointed in neat slurry and pointed in white or coloured cement to match, incl 15mm thick screed bed in CM 1:4. Complete all as specified and directed by Engineer-In-Charge. | item40 | 92 | Sqm |
41 | 41 | S&F in repairs vitreous ware wash down water closet (pedestal) and flush pipe 32mm dia and seat cover with fixtures etc. Complete all as specified and directed by Engineer-In-Charge. | item41 | 3 | Each |
42 | 42 | S&F in repairs 10 ltrs syphonic action type, flushing cistern low level, white with inlet ball valve float and pull brackets. Complete all as specified and directed by Engineer-In-Charge. | item42 | 3 | Each |
43 | 43 | S&F in repair vitreous china ware wash hand basin white, flat back, size 550 x 400mm size (flat back or angle back type) including cutting for and pinning ends of brackets or erecting stand. Complete all as specified and directed by Engineer-In-Charge. | item43 | 3 | Each |
44 | 44 | S&F in repair 15mm bore brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed. Complete all as specified and directed by Engineer-In-Charge. | item44 | 3 | Each |
45 | 45 | S&F in repairs 15mm bore of bib taps, cast copper alloy fancy type and chromium plated, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed. | item45 | 3 | Each |
46 | 46 | S & F in repairs angle stop valves of PTMT 15mm dia bore, any colour high pressure screwed for iron pipe. Complete all as specified and directed by Engineer-In-Charge. | item46 | 15 | Each |
47 | 47 | S&F PVC connectios 15mm size with PTMT nuts of length 450mm. Complete all as specified and directed by Engineer-In-Charge. | item47 | 15 | Each |
48 | 48 | S&F 600 x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers. | item48 | 3 | Each |
49 | 49 | S&F in repairs of sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60cm long. Complete all as specified and directed by Engineer-In-Charge. | item49 | 3 | Each |
50 | 50 | S&F in repair soap dish, vitreous china white, approximate estimate size 160 x 160 x 90mm fixed to plugs with chromium plated brass screws. Complete all as specified and directed by Engineer-In-Charge. | item50 | 3 | Each |
51 | 51 | S&F towel rail 600mm long of PTMT fixed with and incl chromium plated brass screws and wooden / plastic cleats. Complete all as specified and directed by Engineer-In-Charge. | item51 | 3 | Each |
52 | 52 | M&L for keyed pointing in cement mortar 1:4 to random rubble or polygonal rubble masonry including racking out joints etc. Complete all as specified and directed by Engineer-In-Charge. | item52 | 0.9 | Per 10 Sqm |
53 | 53 | S&F cast iron nahani trap of 75mm outlet with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4). Complete all as specified and directed by Engineer-In-Charge. | item53 | 3 | Each |
54 | 54 | M&L for moorum/red bajri filling in floors or pavings, laid in layers not exc 15 cm thick, spread, levelled and rammed incl watering. Complete all as specified and directed by Engineer-In-Charge. | item54 | 55 | Cum |
55 | 55 | M&L for 100mm thick PCC 1:4:8 type D-2 (40mm graded aggregate), laid in floors, Complete all as specified and directed by Engineer-In-Charge. | item55 | 75 | Sqm |
56 | 56 | M&L for hard core gauge not exc 63mm deposited spread and levelled in layer not exc 15 cm thick watered to a true surface (broken stone or boulders). Complete all as specified and directed by Engineer-In-Charge. | item56 | 140.4 | Cum |
57 | 57 | M&L for butt hinges, medium weight cold rolled, mild steel, 100 mm size and fixed. Complete all as specified and directed by Engineer-In-Charge. | item57 | 27 | Each |
58 | 58 | All as per item No.57 above but 75 mm size butt hinges. | item58 | 52 | Each |
59 | 59 | S&F aluminium handle 150 mm size cast type anodised. Complete all as specified and directed by Engineer-In-Charge. | item59 | 12 | Each |
60 | 60 | All as per item No.59 above but 125 mm size al handle. | item60 | 26 | Each |
61 | 61 | S&F aluminium anodised barrel tower bolts 200 mm long of extruded section. Complete all as specified and directed by Engineer-In-Charge. | item61 | 12 | Each |
62 | 62 | All as per item No.61 above but 75 mm size tower bolts. | item62 | 26 | Each |
63 | 63 | S&F aluminium alloy anodised sliding door bolt 300 mm long with hasp and staple. Complete all as specified and directed by Engineer-In-Charge. | item63 | 9 | Each |
64 | 64 | Excavation over areas, not exc 1.50mtr deep and getting out in hard/dense soil. Complete all as specified and directed by Engineer-In-Charge. | item64 | 452 | Cum |
65 | 65 | M&L for 150mm thickness of soling (or sub base) with broker boulders or quarried stone, inter stices filled, surface formed and rolled and consolidated to required gradient and camber. Complete all as specified and directed by Engineer-In-Charge. | item65 | 86 | Per 10 Sqm |
66 | 66 | M&L for cement concrete work in pavement/ hard standing of flexural strength 40kg/per square centimetre in filed using 400kg of of cement per cubic metre, thickness of concrete 15cm thick. Complete all as specified and directed by Engineer-In-Charge. | item66 | 129 | Cum |
67 | 67 | M&L for cement concrete work in pavement/ hard standing of flexural strength 40kg/per square centimetre in filed using 400kg of of cement per cubic metre, thickness of concrete 10cm thick. Complete all as specified and directed by Engineer-In-Charge. | item67 | 86 | Cum |
68 | 68 | Forming contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound Grade 'A'. Complete all as specified and directed by Engineer-In-Charge. | item68 | 29 | Per 10 RM |
69 | 69 | M&L for sand filling under floors or in foundations including watering and consolidation. Complete all as specified and directed by Engineer-In-Charge. | item69 | 53.8 | Cum |
70 | 70 | M&L for polythene film, black, 50 micron laid in floors. Complete all as specified and directed by Engineer-In-Charge. | item70 | 860 | Sqm |
71 | 71 | Removing excavated material not exc 50mtr and depositing where directed at a level not exc 1.50mtr above the starting point. Complete all as specified and directed by Engineer-In-Charge. | item71 | 474.4 | Cum |
72 | 72 | S & F of second claass soft wood 40mm thick for boarding in flooring planed one side with butt joints and fixed with nails. Complete all as specified and directed by Engineer-In-Charge. | item72 | 48 | Sqm |
73 | 73 | S & F Anodised aluminium window and ventilator shutters, fixed type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap biading, screw etc. Complete all as specified and directed by Engineer-In-Charge. | item73 | 1.35 | Sqm |
74 | 74 | S&F 2nd Class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid rounded or chamfered put together with glue pinned at joints. Complete all as specified and directed by Engineer-In-Charge. | item74 | 0.62 | Cum |
75 | 75 | M&L for 2nd class hard wood 40mm thick plain framed, panelled shutter (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces, the size of rail and stile as per IS: 1003 (Part-I), kiln seasoned and chemically pressure treated. Complete all as specified and directed by Engineer-In-Charge. | item75 | 5.4 | Sqm |
76 | 76 | M&L for preparation of old painted zinc or galvanised surface of any description and in position and applying one coat of synthetic enamel paint all as specified. Note :-(a) The surface of corrugated steel sheeting shall be measured flat (not girth) without any extra allowance for laps and the area obtain shall be increased by 14%).(b) The surface of plain steel sheeting as in ridge, hips, velley gutters, flashings etc, shall be measured flat alongwith girth (length and firth as fixed) and the area obtained shall be added to the area of corrugated steel sheeting. | item76 | 17.1 | Sqm |
77 | 77 | M&L for chequered cement concrete tiles with grey cement and pigment of size 20cm x 20cm x 25mm thick, set jointed and poited in neat cement slurry in floors and cut and polished with grey cement and pigments to match on screed bed or beding layer of 20mm thick in CM1:4. Complete all as specified and directed by Engineer-In-Charge. | item77 | 18 | Sqm |
78 | 78 | S&F in repairs of toilet paper holder coloured, vitreous china nox type fixed to walls with chromium plated. Complete all as specified and directed by Engineer-In-Charge. | item78 | 1 | Each |
79 | 79 | Dismantiling of cast iron pipe jointed in cement mortar and taking out of trenches, if required (75/100mm dia of pipe). Complete all as specified and directed by Engineer-In-Charge. | item79 | 45 | RM |
80 | 80 | S&F cast iron soil waste and vent pipes in any lenght with or without ears, with cement joints spun pipe 100mm dia. Complete all as specified and directed by Engineer-In-Charge. | item80 | 20 | RM |
81 | 81 | S&F cast iron soil waste and vent pipes in any lenght with or without ears, with cement joints spun pipe 75mm dia. Complete all as specified and directed by Engineer-In-Charge. | item81 | 23 | RM |
82 | 82 | S&F cast iron soil waste and vent pipes in any lenght with or without ears, with cement joints spun pipe 75mm dia but fixed to walls. Complete all as specified and directed by Engineer-In-Charge. | item82 | 2 | RM |
83 | 83 | S&F cast iron bends, diminishig pieces or tapers 100mm dia. Complete all as specified and directed by Engineer-In-Charge. | item83 | 3 | Each |
84 | 84 | All as per item No. 83 above but 75mm dia. | item84 | 3 | Each |
85 | 85 | S&F cast iron 75mm cowl. Complete all as specified and directed by Engineer-In-Charge. | item85 | 1 | Each |
86 | 86 | S&F harrison rail, anodised aluminiu alloy with chromium plated fixig brackets, stops, rollers etc. Complete all as specified and directed by Engineer-In-Charge. | item86 | 20 | RM |
87 | 87 | Taking down or up 15mm bore GI tubing including cleaning for refixing or removal to store etc. Complete all as specified and directed by Engineer-In-Charge. | item87 | 25 | RM |
88 | 88 | Taking down or up 20mm bore GI tubing including cleaning for refixing or removal to store etc. Complete all as specified and directed by Engineer-In-Charge. | item88 | 20 | RM |
89 | 89 | S&F 20mm outer dia of 3- layer PPR Polypropylene random copolymer concealed pipes SDR 7.4 (PN-16) unstalised and antimicrobial fusion welded having thermal stability for hot or cold water supply including all PPR pain & brass threaded polypropylene random fittings fixed complete to wall, celings or in floors. Complete all as specified and directed by Engineer-In-Charge. | item89 | 25 | RM |
90 | 90 | S&F 25mm outer dia of 3- layer PPR Polypropylene random copolymer concealed pipes SDR 7.4 (PN-16) unstalised and antimicrobial fusion welded having thermal stability for hot or cold water supply including all PPR pain & brass threaded polypropylene random fittings fixed complete to wall, celings or in floors. Complete all as specified and directed by Engineer-In-Charge. | item90 | 25 | RM |
91 | 91 | Taking down carefully copper/aluminium point wiring (light, fan, socket 5/15 Amps) complete including fixture and fitting such as switches, socket, ceiling roses, pendants, regulator, sockets, light fittings etc and making good to disturbed surfaces etc. Complete all as specified and directed by Engineer-In-Charge. | item91 | 463 | Per Point |
92 | 92 | M & L for point wiring with 1.5 sq mm copper conductor (multistranded), fire retardent low smoke , single core PVC insulated, unsheathed, 1100 volt grade cable conforming to IS- 694 part I in and incl PVC casing and capping with all accessories and terminated in PVC moulded/ engineering plastic boxes/modular plate suitable for any module for modular switches and sockets, duly earthed with PVC insulated 1.5 sq mm copper conductor cable in green colour for earth continuity conductor to earth dolly for one light point controlled by one switch. Complete all as specified and directed by Engineer-In-Charge. | item92 | 276 | Per point |
93 | 93 | All as per item No. 92 above but for one Fan/Exhaust Fan controlled by one switch. | item93 | 8 | Per point |
94 | 94 | All as per item No. 92 above but for one 5 pin 5 Amps switch socket outlet on independent board. | item94 | 30 | Per point |
95 | 95 | All as per item No. 92 above but for one 5 pin 5 Amps switch socket outlet on same board. | item95 | 30 | Per point |
96 | 96 | All as per item No. 92 above but point wiring with 2.5 sqmm, PVC insulated , fire retardent , multistrandard copper cable , 1100 volts grade,conforming to IS: 694 for 5 Pin 5/15 Amp switch socket combination on Independent board with 2.5 sq mm pvc insulated, fire retardent multistranded green in colour for earth continuity conductor cable. Complete all as specified and directed by Engineer-In-Charge. | item96 | 30 | Per point |
97 | 97 | All as per item No. 96 above but for one 5 pin 5/15 Amps switch socket outlet on same board. | item97 | 30 | Per point |
98 | 98 | All as per item No. 92 above but point wiring with 4.0 sqmm, PVC insulated , fire retardent , multistrandard copper cable , 1100 volts grade,conforming to IS: 694 for 6 Pin 15 Amp switch socket combination on Independent board with 4.0 sq mm pvc insulated, fire retardent multistranded green in colour for earth continuity conductor cable Complete all as specified and diretced by Engineer-in-Charge. | item98 | 59 | Per Point |
99 | 99 | S&F switch piano flush type, single pole, one way 6 amp 240 volts, Complete all as specified and directed by Engineer-In-Charge. Make: Anchor / Bajaj /Havells Note : Taking down of swithches included in taking down of point wiring item of Sch A. | item99 | 150 | Each |
100 | 100 | S&F Socket 6A - 2/3 pin combined 2 module including PVC laminated plate of suitable size with PVC boxes flush type or surface Complete all as specified and directed by Engineer-In-Charge. | item100 | 60 | Each |
101 | 101 | S&F Modular switch 16A, 1 module 240 V including PVC laminated plate of suitable size with PVC boxes flush type or surface Complete all as specified and directed by Engineer-In-Charge. | item101 | 24 | Each |
102 | 102 | S&F Socket 16A - 2/3 pin combined 2 module including PVC laminated plate of suitable size with PVC boxes flush type or surface Complete all as specified and directed by Engineer-In-Charge. | item102 | 24 | Each |
103 | 103 | S&F ceiling rose surface backlite, 65x50mm, three terminals, 5 Amps,240 Volts AC. Complete all as specified and directed by Engineer-In-Charge. | item103 | 208 | Each |
104 | 104 | S&F in repairs Endura linear LED wall mounted batten, extruded aluminium heat sink provided for heat dissipation and integrated electronic driver for 22W LED 6K 4 feet including LED tube rod , bipin holders, connecter block, etc complete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. Complete all as specified and diretced by Engineer-in-Charge. Make:Cat part No-LHEWEBP7PL 1W022 of Havells or equivalent in Wiprio/Philips. | item104 | 31 | Each |
105 | 105 | S & F in repairs LED luminarie basic all purpose surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver of 1x18W , complete all as specified and diretced by Engineer-in-Charge. Make : Havells cat part no.-LUMILINEBS18WLED840SPCWH or eqvlnt in Wiprio/Philips. | item105 | 20 | Each |
106 | 106 | S&F in repairs lamp holder, pvc/polycarbonate type with back plate suitable for pendant fittings. Complete all as specified and diretced by Engineer-in-Charge. | item106 | 60 | Each |
107 | 107 | S & F in repairs exhaust fan heavy duty 450 mm complete with all accessories internally pre wired and including connecting up with twin core twisted flexiable copper conductor cable with suitable size. Complete all as specified and diretced by Engineer-in-Charge. Make :- Havells/Standard/Bajaj. | item107 | 3 | Each |
108 | 108 | S & F in repairs water storage heater type of capacity 25 Litrs BEE 5 star, 230 volts. Complete all as specified and diretced by Engineer-in-Charge. Make: Havells code No:GHWAPTTWH025HSN or eqvlnt. | item108 | 3 | Each |
109 | 109 | S&F in repairs single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB 10 Amp. Complete all as specified and diretced by Engineer-in-Charge. | item109 | 2 | Each |
110 | 110 | S&F in repairs sheet metal enclosure for DBs to be used for single pole neutral 8 way with 200amps rated bus bar DBs 240V Make:- Siemens/ Legrand/GEC/ Schneider. Complete all as specified and diretced by Engineer-In-Charge. | item110 | 9 | Each |
111 | 111 | S&F in repairs sheet metal enclosure when MCBs to be used for Single pole neural 4 way 200Amp rated bus bar complete all as specified and diretced by Engineer-in-Charge. | item111 | 4 | Each |
112 | 112 | S&F in repairs sheet metal enclosure when MCBs to be used for single pole neural 12 way 200Amp rated bus bar. Complete all as specified and diretced by Engineer-In-Charge. | item112 | 3 | Each |
113 | 113 | S&F in repairs sheet metal enclosure when MCBs DB to be used for triple pole neural 12 way 200Amp rated bus bar. Complete all as specified and diretced by Engineer-In-Charge. | item113 | 1 | Each |
114 | 114 | S&F in repairs MCB SP 6 to 32 Amp B Series 240 Volt. Make :- Havells Cat part No-DHMGBSPF006-032 or eqvlnt. | item114 | 77 | Each |
115 | 115 | S&F in repairs MCB DP 6 to 32 Amp Complete all as specified and diretced by Engineer-In-Charge. Make:-Havells CAT No-DHMGCDPF006-032 or eqvlnt. | item115 | 20 | Each |
116 | 116 | M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60cmx 6.3 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level , connected to 4 mm dia GI wire as earthling lead by means blots and nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber , MS funnel, wire gauge. CI cover with frame , 15 mm dia GI pipe light grade for protection of wire etc including necessary excavation in any type of strata , returning, filling removal of soil outside MoD land ,filling of charcoal and salt complete all as shown in electrical plate No. 5 of MES Sch Part I , connected to earthing test point, testing on completion. Complete all as specified and diretced by Engineer-In-Charge. | item116 | 7 | Each |
117 | 117 | Excavation in trenches n exc 1.5 m wide & n exc 1.5 mtr deep in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes etc not exc 10 sqm on plan and n exc 1.5 mtr in depth and getting out of soft/lose soil for taking out pipe & laying of pipe & getting out for diverting of CI pipe line. Complete all as specified and diretced by Engineer-In-Charge. | item117 | 44 | Cum |
118 | 118 | Returning, filling in, including spreading, leveling, watering & well ramming in layers n. exc 25 cm. Complete all as specified and diretced by Engineer-In-Charge. | item118 | 31.6 | Cum |
119 | 119 | M&L for sub class "B" bricks laid dry width wise across the line of cable in trenchs as cable protection. Complete all as specified and diretced by Engineer-In-Charge. | item119 | 1760 | Each |
120 | 120 | Supply, laying ,connecting/Jointing,charging, testing and commissioning LT cable electric, XLPE insulated, armoured, PVC sheathed, heavy duty, electric cable 1100 Volt grade with stranded aluminum conductor conforming to IS :7098, laid in trenches/ducts/fixed to wall /roofs/ poles all as specified of size 3.5 Core 70 sq mm incld taking down. Complete all as specified and diretced by Engineer-In-Charge. | item120 | 80 | RM |
121 | 121 | S&F in repairs switch disconnector 63 A 3 pole and neutral suitable for bolted cubical with HRC fuses ,415V, 50Hz conforms to IS 13947. Complete all as specified and diretced by Engineer-In-Charge. | item121 | 3 | Each |
122 | 122 | S&F in repairs steel water tubing light grade galvainsed of size 40mm with all fitting fixed on wall for building lights/ road crossing. Complete all as specified and diretced by Engineer-In-Charge. | item122 | 27 | RM |
123 | 123 | S & F in repairs JETA 30 LED flood light luminarie with 30 W high power COB LED as light source for 30 w KED 5 K, connector block, etc complete with all accessories internally pre wired and including connecting up with twin core twisted flexiable copper conductor cable with suitable size.Complete all as specified and diretced by Engineer-In-Charge. Make: Cat part No-LHEPCZUUE146JO30 of Havells or eqvlnt in Wiprio/Philips. | item123 | 4 | Each |
124 | 124 | Supply ,Laying ,connecting/ Jointing,charging, testing and commissioning LT cable electric, XLPE insulated, armoured, PVC sheathed, heavy duty, electric cable 1100 Volt grade with stranded aluminum conductor conforming to IS :7098, laid in trenches/ducts/fixed to wall /roofs/ poles all as specified of size 3.5 Core 35 sq mm incld taking down old unsv. Complete all as specified and diretced by Engineer-In-Charge. | item124 | 215 | RM |
125 | 125 | S&F modular switch 6A, 1 module 240 V including PVC laminated plate of suitable size with PVC boxes flush type or surface Complete all as specified and diretced by Engineer-In-Charge. | item125 | 194 | Each |
126 | 126 | S & F Switch socket outlet 3 pin 5 amp' flush type. Complete all as specified and diretced by Engineer-In-Charge. | item126 | 60 | Each |
127 | 127 | S & F Switch socket outlet 3 pin 15 amp' flush type Complete all as specified and diretced by Engineer-In-Charge. | item127 | 35 | Each |
128 | 128 | S & F in repairs LED luminarie Basic all purpose surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver of 1x18W , complete all as specified and diretced by Engineer-in-Charge.Make : Code No-LUMILINEBS18WLED840SPCWH of Havells or eqvlnt. | item128 | 150 | Each |
129 | 129 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 sqmm suspension wire, one twin core cable flat or circular stranded al conductor of size 6 sqmm Complete all as specified and diretced by Engineer-In-Charge. | item129 | 500 | RM |
130 | 130 | S & F in repairs MCB TPN 40 Amp 240Volt Cat part No-810096 HSN Code 8536 Complete all as specified and diretced by Engineer-In-Charge. Make:- Indo Asian or equivalent | item130 | 3 | Each |
131 | 131 | S & F in repairs MCB TPN 63 Amp 240Volt Complete all as specified and diretced by Engineer-In-Charge. Make:- Indo Asian Cat part No-810098 HSN Code 8536 or equivalent | item131 | 2 | Each |
132 | 132 | S & F in repairs house service bracket (hook type complete with 3.0m long G.I. pipe 40mm dia Med. grade, two nos 90d bends. M.S. hook and stay or guy Complete all as specified and diretced by Engineer-In-Charge. | item132 | 2 | Each |
133 | 133 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, two single core cable stranded conductor of size 6 sqmm incld taking down. Complete all as specified and diretced by Engineer-In-Charge. | item133 | 500 | RM |
134 | 134 | S & F in repairs exhaust fan heavy duty 450 mm complete with all accessories internally pre wired and including connecting up with twin core twisted flexiable copper conductor cable with suitable size complete all as specified and diretced by Engineer-in-Charge. Make :- Havells or eqvlnt. | item134 | 4 | Each |