Rural Development and Panchayat Raj Department has published Internal Electrification For Conversion Of First Floor Of Old Animal House ( Vacated By Security Forces ) Into Deemed Skims University At Skims Soura . . Submission Date for this Tender is 12-02-2020. Electrification Work Tenders in SKIMS Soura Jammu And Kashmir. Bidders can get complete Tender details and download the document.
Name of Work: Internal Electrification for conversion of first Floor of Old Animal house (vacated by security forces) into Deemed SKIMS University at SKIMS Soura. | |||||
---|---|---|---|---|---|
Sl. No. | Electrification | Item Code / Make | Quantity | Units | |
1 | 1 | Wiring to be carried out for fresh light points through PVC conduit 25mm x 2mm in concealed/surface manner(as per site requirement ) using 1.5 sq. mm x 3 nos (P+N+E) FR PVC insulated copper wire multistrand (Havell's/ Polycab/KEI /paramount make) complete with P/F of switch 5/6 amps F/T (SSK/Havell's Reo/Anchor Penta pc make) to be fitted on 3mm Bakelite sheet suitable size, rowel plugs & screws etc. complete Point. | item1 | 300 | pts |
2 | 2 | Wiring to be carried out for fresh heating point in concealed manner through PVC conduit of 25 mm dia 2 mm thick using multi strand 3 x 2.5 mm.sq pvc insulated copper wire (Havells/Finolex/ Polycab/Paramount make FR) complete with P/F of switch socket combine 15/16 amps 5 pin F/T (SSK/Havells/ Anchor Penta pc make) to be fitted on Bakelite sheet suitable size, rowel plugs & screws etc. complete Point with civil work . | item2 | 100 | pts |
3 | 3 | Wiring to be carried out for fresh Computer points in concealed manner through PVC conduit of 25 mm dia 2 mm thick using multi strand 3 x 2.5 mm.sq pvc insulated copper wire (Havells/KEI Polycab/Paramount make FR) complete with P/F of switch socket combine 15/16 amps 5 pin F/T (SSK/Havells/Anchor penta pc make) to be fitted on Bakelite sheet suitable size, rowel plugs & screws etc. complete Point with civil work . | item3 | 90 | pts |
4 | 4 | Supply & laying of circuit wires as per site requirements using multi strand pvc insulated copper wire (Havells /KEI/ Polycab/Paramount make FR) (excluding the cost of conduit) in recessed /surface manner PVC Conduit. | item4 | ||
5 | 5 | 1 X 2.5 mm 2 multi strand pvc insulated copper. | item5 | 1200 | mtr |
6 | 6 | 1 X 4 mm 2 multi strand pvc insulated copper. | item6 | 1500 | mtr |
7 | 7 | 1 X 10 mm 2 multi strand pvc insulated copper. | item7 | 1000 | mtr |
8 | 8 | 1 X 16mm 2 multi strand pvc insulated copper. | item8 | 200 | mtr |
9 | 9 | Providing and laying of 3.5 core XLPE/PVC insulated AL.cable armoured of various sizes as mentioned below as fresh ones ( Polycab/Havells/Paramount/Gloster make). | item9 | ||
10 | 10 | 240 mm sq. | item10 | 420 | mtr |
11 | 11 | 95 mm sq. | item11 | 60 | mtr |
12 | 12 | Providing and making of end termination of the following 3.5 core LT cable including thimbling, crimping, testing and connecting as per site requirement. (Dowels/3D make) | item12 | ||
13 | 13 | 240 mm sq. | item13 | 4 | sets |
14 | 14 | 95 mm sq. | item14 | 4 | sets |
15 | 15 | Excavation of soil of cable and refilling the same with sand cushioning and bricks as per latest specifcation. | item15 | 60 | mtr |
16 | 16 | Providing and fixing of iron hook 10" long L type for fixing of cable fabricated from iron angle of size 40x40x5 mm | item16 | 40 | no |
17 | 17 | Providing and fixing of 25mm medium class PVC conduit 2mm thick along with accessories a) in recess manner by way of cutting chieseling the wall surface and plastering the same after fixing the conduit. | item17 | 700 | mtr |
18 | 18 | b) in surface manner | item18 | 300 | mtr |
19 | 19 | P/F of 3 pin socket 5/6 amps (SSK/Havell's /Anchor penta pc make) | item19 | 91 | mtr |
20 | 20 | P/F of bakelite / phenolic laminated sheet 3 mm thick | item20 | 25 | sft |
21 | 21 | Providing, installation, testing and commissioning of following luminaries (Havells/Wipro/Philips/Trilux make) | item21 | ||
22 | 22 | Providing and fixing 1200 mm long led batten 6000/6500k Light having aluminium heat sink body with anti-glare diffuser with energy efficient electronic driver CRI greater than 80 with minimum sytem lumens 2000 and maximum wattage 22 including connection with multistrand copper conductor 3 core cable etc as required at site. | item22 | 30 | no |
23 | 23 | Recessed/Surface type LED luminaries square/ circular type slim decorative aluminium casted and separate electronic driver with system temperature 6000/6500 K and robust construction in combination with flat diffuser. (Philips /havells/ Osram /trilux make) with minium system Lumens 1200 and maximum wattage 15 W. | item23 | 165 | no |
24 | 24 | Recessed type 2' x2' LED Square Panel IP -20 of 36-40 watt with system temperature 5000/6000/6500 K having minimum sytem lumen efficacy 90 with powder coated CRCA sheet steel housing with profiled/flat efficiency diffuser along withConstant current electronic driver.(Philips RC 380/Trilux/Zumtobel/Wipro make) | item24 | 40 | no |
25 | 25 | Supply installation testing and commissioning of 250 mm dia exhaust fans with plastic shutters and including the cost of wall opening and making good etc complete as required. (Havells/ Crompton/BajajMake) | item25 | 23 | no |
26 | 26 | Providing and installation of Wall mount fans 400 mm copper wound heavy duty.(Havells,/Crompton/Bajaj ) | item26 | 42 | no |
27 | 27 | Providing and fixing of Geysers (Venus/Havell's/ Recold make) complete with geyser bolts with PVC flexible connection complete with civil works in all respects . a) Capacity 50 Litres | item27 | 2 | no |
28 | 28 | 35 litre capacity | item28 | 2 | no |
29 | 29 | Supplying and fixing following rating, 240/415 volts, “C”curve,10KA miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Legrand/Schneider acti -9/Siemens make) | item29 | ||
30 | 30 | MCB single pole 6 A to 32 A | item30 | 180 | no |
31 | 31 | MCB TPN 40 A | item31 | 4 | no |
32 | 32 | MCB TPN 32 A | item32 | 3 | no |
33 | 33 | Supplying and fixing following way TPN, sheetsteel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper insulated bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (SSK/Havells/Indo Asian /Schneider make) | item33 | ||
34 | 34 | 6 Ways | item34 | 3 | no |
35 | 35 | 8 Ways | item35 | 4 | no |
36 | 36 | Supply, installation, testing and commissioning of factory assembled sheet steel clad powdercoated, stand mounting cubicle board made from 1.6mm thick CRCA sheet dust and vermin proof dully phosphatized and powder coated ,provided with hinged gasketted door padlocking facility and including suitably rated PVC insulated 4 strip Aluminium bus bar complete with interconnections,providing lugs, earthing terminals,etc including providing fixing of below noted accessories (Legrand/Schneider /L&T (D sine series) /Siemens make) \n1. Incomming :-400 amp FP MCCB having breaking capacity= 36KA with rotary handle operating mechanism b) Metering :- (0-500 Volt) Digital voltmeter with selector switch =1set (0-400 amp) Digital ammeter with selector switch & 400/5 C.T.'s =1set Indication lamps R/Y/B with backup MCB 1 set of three. \n2. BUSBAR :-500 amp 4 strip Aluminium Busbar. 3. OUTGOING :- a) 200 amp FP MCCB having breaking capacity 36KA with rotary handle operating mechanism = 1no. b) 125 amp having breaking capacity 10KA with rotary handle operating mechanism =02 no. c) 63 amp TPN having breaking capacity 10KA = 5 no. d) 40 amp TPN having breaking capacity 10KA = 5 no. \n4) Fixing of Angle iron stand of thickness 5mm for above mentioned panel of height 1'-6'' form ground. | item36 | 1 | no |
37 | 37 | Making of earth point includes salt charcoal in copper plate of size 600 mmx600x3mm pit should be dug 3 mtr from the surface and providing and fixing G.I strip (25 mm X 5 mm) in 40 mm dia G.I.The job also including providing and laying of seperate 40 mm G.I watering pipe to the plate complete as per latest specification. | item37 | 3 | job |
38 | 38 | Providing and fixing of 25 mm x 5 mm G.I strip on surface or in recess for connections etc. as required.Jointing shall be done by overlapping and with 2 sets of galvanised nut bolts and spring washer spaced at 50 mm . | item38 | 200 | mtr |
39 | 39 | Providing and laying of insulating mat atleast 25 mm thick to withstand 3.3 kV dielectric strength . | item39 | 4 | sq. mtr |
40 | 40 | UPS SYSTEM:- Supply, Installation, testing & Commissioning of high performance, Fully digital, 3 phase input & 3 phase output and microprocessor based UPS system with 30 minuts backup of following rating complete with high output power factor 0.9, Eco mode efficiency up to 98%, wide input voltage range: 380-400-415 ( Selectable) ± 20%@400v (Protect battery discharge during voltage distortion. Wide frequency range:45Hz to 65Hz. Inbuilt static by pass and manual bypass, Inbuilt phase sequence correction, Inbuilt standard potential free contants, panel LCD display complete as required. the job includes providing fixing of suitable site battery Rack oalong with batteries of make Exide/Amaron /Rocket . 20 KVA (3 phase in/ 3 phase out) (Schneider APC/Emerson/Eaton make ) | item40 | 1 | no |