| 1 | 1 | PART 'A' | | | |
|---|
| 2 | 2 | Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level. In all types soils/ saturated soil such as moorum, sand, sandy silt, clay, black cotton soil, kankar, etc. Depth upto 1.5 m | | 84.375 | cum. |
|---|
| 3 | 3 | Earth filling with available surplus soil excavated from foundations and taken only from outside of building plinth in layers not exceeding 20cm in depth, consolidating each deposited layer including ramming and watering and consolidation with lead up to 50 m and lift upto 1.5 m. | | 85.41 | Cum |
|---|
| 4 | 4 | Carriage of Materials by mechanical transport including loading, unloading and stacking : Earth (Rate for lead 5km.) | | 85.41 | Cum |
|---|
| 5 | 5 | Supplying Chlorpyriphos/ Lindane emulsifiable concentrate of 20% in sealed containers including delivery as specified. | | 20 | Ltr. |
|---|
| 6 | 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinthlevel : 1:4:8 (1 Cement : 4 fine/ coarse sand : 8 graded stone aggregate 40 mm nominal size). P.C.C. | | 10.4625 | Cum |
|---|
| 7 | 7 | Centring and shuttering with plywood or steel sheet upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete. | | 69.12 | Sqm. |
|---|
| 8 | 8 | Columns, Pillars, Piers, Abutments, Posts and Struts up to plinth level For Column Upto DPC Bottom | | 132 | Sqm. |
|---|
| 9 | 9 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. | | 45 | Sqm. |
|---|
| 10 | 10 | Suspended floors, roofs, landings, balconies and access platform | | 200 | Sqm. |
|---|
| 11 | 11 | Reinforcement for R.C.C. work at all levels including straightening, cutting, bending, placing in position and binding all complete. Hot rolled deformed bars | | 6577.29 | Kg |
|---|
| 12 | 12 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level : 1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size). (As per design mix) | | 17.568 | Cum |
|---|
| 13 | 13 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto two stories excluding cost of centring, shuttering, finishing and reinforcement : 1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size) (As per design mix) | | 13.698 | Cum. |
|---|
| 14 | 14 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto two stories excluding cost of centring, shuttering, finishing and reinforcement :M-25 Grade Concrete (1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size) -As per design mix) | | 34.5069 | Cum |
|---|
| 15 | 15 | Random rubble masonry with hard stone in foundation and plinth : Cement mortar 1:6 (1 cement : 6 coarse sand) | | 25.3125 | Cum |
|---|
| 16 | 16 | Random rubble dry stone Kharanja (soling) under floor. | | 21.3525 | Cum |
|---|
| 17 | 17 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level : 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). Under floor PCC | | 10.6762 | Cum |
|---|
| 18 | 18 | Brick work with FPS bricks of class designation 75 in superstructure above plinth level upto two stories in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) | | 41.4 | Cum. |
|---|
| 19 | 19 | Half brick masonry with FPS bricks of class designation 75 in superstructure above plinth level upto two stories. Cement mortar 1:4 (1 cement :4 coarse sand) | | 25 | Sqm |
|---|
| 20 | 20 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). (Cement concrete Dal) | | 181 | Sqm |
|---|
| 21 | 21 | Extra for providing and mixing water proofing material in cement concrete work @ 1 kg per 50kg of cement. | | 50 | Kg |
|---|
| 22 | 22 | Cement plastering including T&P, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 20 mm cement plaster of mix : 1:4 (1 cement : 4 fine/ coarse sand) | | 300 | Sqm |
|---|
| 23 | 23 | Cement plastering including T&P, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 12 mm cement plaster of mix : 1:4 (1 cement : 4 fine/ coarse sand) Ceilling plaster | | 200 | Sqm |
|---|
| 24 | 24 | Kota stone slab flooring 25mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : Area of each slab 900 to 2000 sqcm | | 150 | Sqm |
|---|
| 25 | 25 | Providing and fixing 1st quality MAT & GLOSSY finished ceramic tiles colour such as standard white, grey, ivory, fume, red brown, light green, light blue, and other light shades with water absorbtion less than or equal to 0.08% confirming to IS : 13753 & IS : 15622 in floor, steps etc laid on bed on neat cement slury finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the the cost of cement mortar bed 1:4) Size 300mm x 450mm\n | | 20 | Sqm |
|---|
| 26 | 26 | Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete Birla/J.K./Nerolac or ISO. As per direction of Engineer in charge. | | 500 | Sqm |
|---|
| 27 | 27 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shad. New work (two or more coats) over and including priming coat with cement primer. | | 500 | Sqm |
|---|
| 28 | 28 | Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. (Upto to 1500 Cm2 Tiles) | | 5 | Sqm. |
|---|
| 29 | 29 | 26.22 Providing and fixing double paitam (rebated) stone doors windows and ventilator frames of approved quality in cement sand mortar 1:4: (Size 125 X 100 MM) | | 40 | Rmt. |
|---|
| 30 | 30 | Providing and fixing fully panelled/partly panelled/ double leaf\nshutter frame for doors as per approved design and drawings with\napproved ordinary C.P./ oxidised steel fittings as per Annexure - 'A'\nand width of styles & top rails of 100mm and lock rails width of\n150mm and bottom rails of 200mm width including teak wood\nbeading of size 19mm x 12mm on both faces complete :Shesham wood grade I | | 10 | Sqm |
|---|
| 31 | 31 | Providing and fixing hand rail of approved size by welding etc. to\nsteel ladder railing, balcony railing and staircase railing including\napplying a priming coat of approved steel primer.G.I. pipes. | | 200 | kg |
|---|
| 32 | 32 | Providing and fixing M.S. round or square bars with M.S. flats at required spacing in wooden frames of windows and clerestory windows.(10 MM) | | 300 | Kg |
|---|
| 33 | 33 | Providing and fixing GI wire gauge of average width of aperture 1.56mm with wire of 0.45mm to existing steel door, window shutter frames with necessary M.S. strip beading 20x3mm with suitable screw at not exceeding 150mm distance etc. complete. . | | 50 | Sqm |
|---|
| 34 | 34 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with L-Type section made of 1.60mm thick M.S. Sheet, joints mitred and welded and grinded finish profiles required size with 15x3mm lugs 10cm long embedded in cement concrete blocks 15x10x10cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primers. | | 300 | Kg. |
|---|
| 35 | 35 | Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : New work (two or more coats) including a coat of approved steel primer but excluding a coat of mordant solution. | | 150 | Sqm |
|---|
| 36 | 36 | PART \"B\" ELECTIRC WORK | | | |
|---|
| 37 | 37 | Wiring of light point / fan point / exhaust fan point / call bell point with 1.5 sq. mm FR PVC insulated unsheathed 1.1kV grade flexible copper conductor and 1.5 sq.mm FR PVC insulated copper earth conductor (IS:694) of approved make in double lock/ ISI marked single lock pvc casing capping & it's accessories, 18 SWG M.S. box with earth terminal, screwless cage connectors for neutral looping in switch board & false ceiling point, 6 A switch 3.0 mm thick phenolic laminated sheet, zinc plated / brass screws, cup washers , making connections, testing etc. as required. (Group-1) | | | |
|---|
| 38 | 37.01 | Short point (up to 3 mtr.) | | 10 | P.Point |
|---|
| 39 | 37.02 | Medium point (up to 6 mtr.) | | 10 | P.Point |
|---|
| 40 | 37.03 | Long point (up to 10 mtr..) | | 10 | P.Point |
|---|
| 41 | 38 | Wiring of 3 pin 6 amp. Light plug point with 1.5 sq. mm FR PVC insulated unsheathed 1.1 kV grade flexible copper conductor and 1.5 sq.mm FR PVC insulated unsheathed 1.1 kV grade copper earth conductor (IS:694) of approved make double lock/ ISI marked single lock pvc casing capping & it's accessories, 18 SWG M.S. box with earth terminal, screwless cage connectors for neutral looping in switch board & falce ceiling point, 6 A switch, 6 A socket, 3.0 mm thick phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required\nOn board | | 20 | P.Point |
|---|
| 42 | 39 | S&F following sizes (dia.) of ISI marked medium duty PVC conduit along with accessories in surface / recessed using saddles, clamps, fastener as required including cutting the wall and making good the same as required. 25 mm (Group-1) | | 100 | Rm |
|---|
| 43 | 40 | P&F 240/415 V MCB of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections with lugs, testing etc. as required. (Group-1) | | | |
|---|
| 44 | 40.01 | Single pole MCB 6 A to 32 A rating | | 4 | Each |
|---|
| 45 | 40.02 | Double pole MCB 6 A to 32 A rating | | 2 | Each |
|---|
| 46 | 41 | P&F Recessed/ Surface mounting heavy duty horizontal type sheet steel Distribution board phophatised/ powder painted complete with copper bus bar, shorting link , neutral link, earth link and din bar masking sheet conforming to IS13032 & IS8623 including making internal DB terminations with copper lugs , testing etc. as required. Double door (single phase) 8 Way (Group-1) | | 2 | Each |
|---|
| 47 | 42 | P & F IS:371 marked 6 amp surface type ceiling rose including making connection testing etc. as required. (Group-1) | | 10 | Each |
|---|
| 48 | 43 | P & F ISI marked 6 amp bakelite batten/angle holder including making connection testing etc. as required. (Group-1) | | 10 | Each |
|---|
| 49 | 44 | Providing & Laying XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 10.0 Sq.mm 2 core (Group-1) | | 100 | Mtr |
|---|
| 50 | 45 | Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required (Group-1) | | 1 | Each |
|---|
| 51 | 46 | S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. | | | |
|---|
| 52 | 46.01 | 8 SWG copper Wire | | 8 | Mtr |
|---|
| 53 | 46.02 | 25mm x 3mm copper strip | | 5 | Mtr |
|---|
| 54 | 47 | P & F of IP20 LED batten type light fixture made from CRCA sheet stlle housing suitable for mounting LED tube system (integral driver), Power consumption of 18W/36W, 1500/3000 lumens, system lumen efficiency 80 lm/ watt output, life time of 50000 burning hours with 70% initial lumen maintained. CCT 3000° K, 4000° K and 6000° K. 4’ LED Tube shape fixture 18W | | 8 | Each |
|---|
| 55 | 48 | P & F energy efficient direct fit (Retrofit) composite compact fluorscent lamp of energy saving labelling not less than 3 star in existing holder/ fixture as required. 18/20 Watt | | 2 | Each |
|---|
| 56 | 49 | P&F of Heavy duty capacitor start 900/1400 RPM single phase ISI marked Exhaust fan,IS:2312 marked in existing opening including making connections testing etc. as required. 300 mm sweep(900/1400 RPM) (Group-1) | | 2 | Each |
|---|
| 57 | 50 | P & F double ball bearing capacitor start ceiling fan of approved make complete with regulator and other accessories as required. (for estimation purpose only) 1200 mm sweep | | 6 | Each |
|---|
| 58 | 51 | Supply and fixing of power plug point accessories on 18 SWG metal box of size 175×100×60mm on surface or in recessed with suitable size phenol laminated sheet cover including cost of 6 pin 16 amp switch and socket outlet making connection, testing, etc. as required. Group-I | | 10 | Each |
|---|