Name of Work: Construction of Bihpuria Stadium Complex, Lakhimpur, Assam under Khelo India Scheme
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.\nUp to a depth of 2.00m below the existing ground level.\nIn ordinary soil\nitem11189Cum
22Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.\nBrick on flat soling.\nitem21895Sqm
33Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).\nIn prop 1cement: 3 sand :6 coarse aggregate by volumeitem3143Cum
44Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in:\nFoundation, footings, bases of columns, pile cap, raft and mass concrete works etc.\nUsing 25mm thick plank\nitem4750Sqm
55Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in:\n\n(i) Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face\nitem54371Sqm
66Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.\n(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) \n\n(i) From Primary Producer: TATA/ SAIL/ Jindal steel/ Shyam steel/ RINL\n Super Ductile (SD) TMT reinforcement barsitem6835Qtl
77Providing and laying reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) \nUsing Mixer Machine - Without using admixture, plasticiser \nIn substructure up to plinth level\nFoundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.\nM25 grade concreteitem7216Cum
88Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) \nUsing Mixer Machine - Without using admixture, plasticiser \nIn super structure from plinth level up to 1st floor level in :\nColumns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing.\n (ii) M25 grade concreteitem9499cum
99Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed.\nIn Sub-structure upto plinth level including dewatering if necessary\nIn proportion 1:4.\nitem1086.5Cum
10101st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately)\n112mm thick brick wall\nIn cement mortar in proportion 1:4 (1 cement:4 sand)\nitem112162Sqm
111120 mm thick Cement plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. \nOn fair side (backing coat 10 mm and finishing coat 10mm thick)\nIn cement mortar 1:4\nitem129526Sqm
1212Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels.\n2 Track sliding window - 6mm clear glass\nitem1371.7Sqm
1313Providing, fitting and fixing factory made Santro Flush door shutters having core & cross bands fabricated from seasoned 1st class timber, 25mm core battens, 2.5mm to 3.5mm uniformly thick cross bands, styles & rails made from hardwood timber of width not less than 50mm, fixed to the door frames (chowkath) with necessary hinges, screws, bolts etc. as specified and directed at all levels (Door fixtures and fittings to be measured and paid seperately.)\n35mm thick\nitem1488Sqm
1414Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified. (a) With sal wooditem152Cum
1515Providing, fitting and fixing PVC Door shutters of 37mm (single panel seamless finish) of Syntex make, at all levels made of extruded sections in the configuration of 'A'.The overall dimension is 37mm x 90mm, with usual process variation having a wall thickness of 2mm with a variation of +0.03mm provided with all plastic reinforcement to avoid rusting. The shutter frame is mitred and joined at the corners by means of stainless steel screws.The corners of the shutter frame are being reinforced by polymeric reinforcement of the size 125mm x 250mm and the lock rail is reinforced by 45 x18 x255 size reinforcement.item1621Sqm
1616Providing, fitting and fixing Syntex PVC door frame made out of extruded PVC section in an overall size of 50mm x 60mm having multi chamber cross section with maximum wall thickness of 2mm, +0.3mm with special polymeric reinforcement having an overall size of 30mm x 25mm width, 150mm length at hardware location. The corner joints shall be either mitre cut and welded or joined by means of concealed cleats with necessary screws fittings.item1752Rm
1717Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary.\nWith river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.item18702Cum
1818Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department)\nNormal range (Somany/Orient/Nitco/Varmora/ Jhonson make\nOf size 600mmx600mm and aboveitem19865.23Sqm
1919Providing polished vitrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/ Sika/ Pedelite/ Rouf)/ white cement slurry mixed with approved pigment to match shade of tilesc complete at all levels as specified and directed. (coloured pigment should be in conformity with colour of tiles and as approved and directed by the department).\nOf size300mmx450mm and above \nitem20407.46Sqm
2020Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/ Sika/ Pedelite/ Rouf)/ white cement complete at all level as specified and directed.\nVITRIFIED - Normal range (Sizes 300 mm x 300mm and above)\nOrient made: Galaxy Brown, Galaxy creama, Galaxy Pink, Galaxy Green, Pulsar Beige, Pulsar Blue, Pulsar Dove, Pulsar Pink, Burj Brown, Burj Green, Burj Slateitem21214.17Sqm
2121Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws.\nOrnamental grill - Fixed to Brickwork/P.C.C/R.C.C. \nitem221434Kg
2222Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm)\nThickness = 1.0 mm thick\nitem239200Sqm
2323Finishing old / new wall with water proofing weather coat smooth anti-fungal exterior painting of approved make of Berger paint of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)item249200Sqm
2424Providing and fixing rolling shutters of approved make made of 80mm wide M.S. laths interlocked together through their entire lenth and jointed together at the ends by end-locks mounted on specially designed pipe shaft with bracket plates, guide channels and arrangements for inside and outside locking with push-pull operation complete including cost of wire, spring and hood cover for the shutters.item25150.5Sqm
2525Providing and fixing M.S. Tube hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer complete as specified and directed by department.item264230Sqm
2626Providing fitting and fixing vitreous water closet squatting pan (Indian type W.C Orissa pattern) with all fittings and fixtures complete including cutting and making good to the walls and floors whereever required. (Flushing Cistern to be paid separately) Indian type W.C Orissa pattern of size 580 x 440 mm ii) Hindware makeitem2717Each
2727Providing fitting and fixing vitreous china pedestal type water closet (European type W.C pan 400mm high ) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately) B) Hindware make a) White (v) Water closet SLICK \"P(Cat.No.20011) (inclusive of seat cover)item286Each
2828Providing fitting and fixing vitreous china flat back type lipped front urinal basin with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required. (B) Hindware Make (viii) Smart with SP (Cat. No.60011)item295Each
2929Supplying, fiting and fixing PVC flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately) ii) Hindware make a) White (i) Sleek+ PVC cisternitem3028Each
3030Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately) PEDESTAL BASIN (with pedestal) Hindware Make - Whiteitem3136Each
3131Providing fitting and fixing Decorative Mirror complete as directed and specified. Parryware Make - Size 800mm x 600mmitem3236Each
3232Providing, fitting and fixing recessed soap tray / soap dish complete as directed and specified. Jaquar Make - Continental (Cat.No.ACN-1331N)item3336Each
3333Providing, fitting and fixing CP towel rail complete as directed and specified. Jaquar make - Continental 600mm (Cat.No. ACN-1111N)item3436Each
3434Providing, fitting and fixing Chrome Plated towel ring complete as directed and specified. Jaquar make - Continental towel ring square (Cat.No. ACN-1121)item3536Each
3535Supplying fitting and fixing chrome plated (C.P.) stop-cock of approved brand and size as mentioned below as directed and specified.(G.I. & C.P pipes will be measured and paid separately) Jaquar - Continental / Clarion 15mm dia, (Concealed stop cock extra heavy with adjustable wall flange)item3654Each
363615mm dia( Angular stop cock with long thread )item3716Each
3737Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed. \n(i) 50mm diaitem385Each
3838Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed. \n(ii) 25mm diaitem392Each
3939Supplying fitting and fixing Ajoy Flowguard CPVC (Chlorinated Polyvinyl Chloride) pipes having thermal stability for hot and cold water supply including all CPVC plain and bruss threaded fitting including clamps at 1.00 m spacing including joining of pipes and fitting with one step CPVC solvent cement and testing of joints complete at all levels as directed and specified. (Note: Ball valve and union will be charged extra and does not comes under Accessories) In internal wall - exposed on wall\ni) 15mm (OD) diameteritem4030Rm
4040Supplying fitting and fixing Ajoy Flowguard CPVC (Chlorinated Polyvinyl Chloride) pipes having thermal stability for hot and cold water supply including all CPVC plain and bruss threaded fitting including clamps at 1.00 m spacing including joining of pipes and fitting with one step CPVC solvent cement and testing of joints complete at all levels as directed and specified. (Note: Ball valve and union will be charged extra and does not comes under Accessories) In internal wall - exposed on wall\nii)20mm (OD) diameteritem4160Rm
4141Supplying fitting and fixing Ajoy Flowguard CPVC (Chlorinated Polyvinyl Chloride) pipes having thermal stability for hot and cold water supply including all CPVC plain and bruss threaded fitting including clamps at 1.00 m spacing including joining of pipes and fitting with one step CPVC solvent cement and testing of joints complete at all levels as directed and specified. (Note: Ball valve and union will be charged extra and does not comes under Accessories) Concealed by chiseling or breaking brick wall/C.C/R.C.C and making good to damages\ni) 25mm (OD) diameteritem4250Rm
4242Supplying fitting and fixing Ajoy Flowguard CPVC (Chlorinated Polyvinyl Chloride) pipes having thermal stability for hot and cold water supply including all CPVC plain and bruss threaded fitting including clamps at 1.00 m spacing including joining of pipes and fitting with one step CPVC solvent cement and testing of joints complete at all levels as directed and specified. (Note: Ball valve and union will be charged extra and does not comes under Accessories) Concealed by chiseling or breaking brick wall/C.C/R.C.C and making good to damages\nii)50mm (OD) diameteritem4365Rm
4343Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed. vii) 110mm diameteritem44250Rm
4444Supplying and placing ferrocement water tanks of circular/rectengular shape over stagging with manhole cover with locking and clearing arrangement including providing pads of size as required for inlet and outlet pipes complete as directed.(Stagging should be measured and paid separately). \n1000 Lt capacityitem452Each
4545Supplying and placing ferrocement water tanks of circular/rectengular shape over stagging with manhole cover with locking and clearing arrangement including providing pads of size as required for inlet and outlet pipes complete as directed.(Stagging should be measured and paid separately). \n2000 Lt capacityitem461Each
4646Supplying and placing ferrocement septic tanks of rectangular shape in to pit with manhole cover with cleaning arrangement over single brick flat soling and 75mm 1:3:6 P.C.C. Baffle wall, inlet and outlet etc are provided at suitable points complete as directed. \n50 Usersitem472Each
4747Supplying and placing ferrocement septic tanks of rectangular shape in to pit with manhole cover with cleaning arrangement over single brick flat soling and 75mm 1:3:6 P.C.C. Baffle wall, inlet and outlet etc are provided at suitable points complete as directed. \n100 Usersitem481Each
4848Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete\n (ii) Medium point up to 6.00 metre. Length.item49283Each
4949Wiring for 5 pin 6 amp plug with 1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) including 5 pin 6 amp socket outlet (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) and 6 amp flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) earthing the 3rd pin of the socket as required on the switch board in surface/ recessed P.V.C. conduit wiring system. When fitted on same board of light and fan.item5042Each
5050Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch ( Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.)\n Medium point up to 6.00 metre. Length.item5110Each
5151Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system.\n (i) With 2 x 1.5 sq. mm. cable in 20 mm dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.item52300Metre.
5252Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system.\n (i) With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.item53300Metre.
5353(ii) With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.item5450Metre.
5454(iii) With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.item5520Metre.
5555Supplying with fitting and fixing of electronic modular fan speed controller 2 - module type MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department.\n (ii)120 watt electronic modular 5 step speed control 2 - moduleitem5694Each
5656Supplying including installation of socket outlet 6/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department.item578Each
5757Supplying including fitting and fixing of following Metal boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE in surface/ recessed system complete as per direction of department.\n (ii) 3 module type Metalitem5810Each
5858Supplying including fitting and fixing of following Metal boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE in surface/ recessed system complete as per direction of department.\n (iv) 6-8 module type Metalitem598Each
5959Supplying with fitting and fixing sheet steel, phosphatised, powder painted Single door surface mounting MCCB enclosure of the following rating MCCB fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt.\n(ABB, Schneider MG, legrand, Hager, Crabtree xpro make)\n for 100A 3P/4P MCCBitem605Each
6060Supplying including fitting fixing of following star rated A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection cable, as approved by the Deptt.s etc. as required complete and as directed by the Department [Without regulator]. (ORIENT PSPO make / Usha make/ CROMPTON make/ Havells/ ATC/ V GAURD make)\n Energy Efficient 5 Star 1200 mm Sweep. (ORIENT PSPO make)item6194Each
6161Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department.\nDomestic - Power Flow 225 mm sweep (ORIENT make)item6213Each
6262Supply, installation & testing of G.I. earth station with perforated 40 mm dia and 4.50 Metre long heady duty G.I. pipe with necessary 40 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .item634Each
6363Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt.item644Each
6464Supplying & laying of 8 SWG G.I. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.item6520Metre.
6565Supplying with fitting and fixing sheet steel, phosphatised, powder painted Single door surface mounting MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt.\n(ABB, Schneider MG, legrand, Hager, Crabtree xpro make)\n 8 way SPN single dooritem665Each
6666Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.\n (I) 6 to 32Aitem6740Each
6767(II) 40Aitem688Each
6868Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DP RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.\n100/300mA sensitivity DP RCCB (ABB, Schneider MG, legrand, Hager make)\n40Aitem694Each
6969Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.\nB Series (Schneider MG, legrand, Hager make)\n (I) 40Aitem704Each
7070(II) 63Aitem714Each
7171Supply and laying of following size Power/Control Copper cables, Solid Copper conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Unarmoured/Armour (Galvanised for cables up to 10 x 1.5 sq mm.8 x 2.5 sq mm.2 x 10 sq mm.3 x 10 sq mm.4 x 6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988, U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make)\n 16.00 Sq. mm.4 Core U.G. armoured cableitem7220Metre
7272Supplying including installation, commissioning of vermin and dust proof totally enclosed cubical indoor type floor/wall mounting compartmentalize panel board of size 1.35M X 1.50MX 0.40M made of 16 SWG (1.66 mm) thick C.R. sheet and 35mm X 35mm X 5mm size angle having 4 no legs at the bottom complete painting with 2 coats of Red Oxide metal primer and 2 coats of enamel paint. The panel board is to be erected in 1 : 3 : 6 PCC foundation including brick soling / grouting etc. complete neatly wiring done with provision for one no 125/160A 4pole MCCB or Switch Fuse Unit as incomer and provision for 8nos DP or TPN out going as specified and directed by the deptt. confirming to IP 43 protection comprising of the following electrical items:\n1. 20mm X 3mm 4 strip copper Bus-Bar 1.4 M length each \n2. Digital 3 Phase Voltmeter Accuracy class 0.5 - 1 no\n3. Digital 3 Phase Ammeter Accuracy class 0.5 - 1 no\n4. Pilot Lamp with integral ckt LED 110- 230 V (Red, Yellow,& Blue) - 3 nos\n5. Voltmeter & Ammeter Selector Switch - 2 nos\n6. 2 A Slide fuse unit - 3nos\n(Incoming & Outgoing Switch Gear of reqd. rating will be measured and paid separately)item731Each
7373Supplying and fixing of batten holder (Anchor Penta PC CHERRY /Gold medal /Kolor kany.kom/Havells or equivalent make as approved by the Deptt.) including connection as approved by the Deptt.)as required Without Lampitem7497Each
7474Philips LED bulbs non-dimmable 7/9 W or equivalent as approved by the Deptt.item7597Each
7575Payment to Local Electricity Board + Campus LED Lightingitem761Lum sum
7676Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary forest royelty, sales tax, land compensation, municipal gate fees, if any monopoly duty etc. (profile measurement to be taken and 12.5% deduction for shrinkage to be made from total quantity) etc. complete as directed and specified.\n(b) Other than Guwahati cityitem776777cum
7777Supplying, fitting and fixing chain link fencing of 10 S.W.G, G.I. Wire 50mm x50mm mesh fitted to M.S angle iron post at 2000mm apart of specification detailed below including supplying, fitting and fixing hooks, eye bolts with nuts, staples and bolts including three horizontal lines of G.I wire 10 S.W.G at top,middle and bottom and with one vertical line to each fencing post for keeping the fencing tight and erect complete, including one coat of primer painting to M.S angle iron post in P.C.C base etc. with following.\na) Corner and end posts with M.S angle of size 50mmx50mmx 5mm and length not less than 1800mm only duly slotted and bottom torqued with two numbers as stay posts.. \nb). Intermediate post with M.S angle of size 40mmx40mmx5mm and length not less than 1800mm only duly slotted and bottom torqued and splayed.\nc).Stay post with M.S angle of size 35 mmx35mmx5mm and length not less than 1800mm duly slotted and bottom torqued and splayed. All M.S angle iron posts are to be fitted to P.C.C base embedded not less than 600mm (P.C.C. work shall be measured and paid separately).item78429Sqm

AI Tender Summary

OUR REF NO 23368348
AUTHORITY Government Departments
TENDER VALUE 2.70 Crore
LAST DATE 12-02-2020
Authority
Authority Name Public Works Department
Work Description Construction Of Bihpuria Stadium Complex , Lakhimpur , Assam Under Khelo India Scheme
Basic Detail
Tender No CS/T/BD/31/2019/7
Bidding Type Tender
Location
City Bihpuria
State Assam
Key Dates
Publish Date 24 Jan 2020
Submission Date 12 Feb 2020
Open Date 12 Feb 2020
Finance
Tender Value 2.70 Crore
Tender Fee 9000
EMD 5.40 Lakhs
Exemption Not Available
Document List
Tendernotice_1.pdf
BOQ_24443.xls
E2023E4C-F9E1-4CDE-ACB8-F1E6FC51442E.html
FOB.pdf
SBD.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 24, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
Feb 12, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Feb 12, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

xls

BOQ_24443.xls

html

E2023E4C-F9E1-4CDE-ACB8-F1E6FC51442E.html

pdf

FOB.pdf

pdf

SBD.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders