| 1 | 1 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. | BI01010001010000000000000515BI0100001112 | | |
|---|
| 2 | 1.1 | 20 mm | BI01010001010000000000000515BI0100001113 | 40 | Mtr. |
|---|
| 3 | 1.2 | 25 mm | BI01010001010000000000000515BI0100001114 | 15 | Mtr. |
|---|
| 4 | 2 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required. | BI01010001010000000000000515BI0100001115 | | |
|---|
| 5 | 2.1 | 3 x 1.5 sq. mm | BI01010001010000000000000515BI0100001116 | 90 | Mtr. |
|---|
| 6 | 2.2 | 4 x 1.5 sq. mm | BI01010001010000000000000515BI0100001117 | 60 | Mtr. |
|---|
| 7 | 2.3 | 3 x 2.5 sq. mm | BI01010001010000000000000515BI0100001118 | 85 | Mtr. |
|---|
| 8 | 2.4 | 3 x 4 sq. mm | BI01010001010000000000000515BI0100001119 | 25 | Mtr. |
|---|
| 9 | 3 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. | BI01010001010000000000000515BI0100001120 | 5 | Set |
|---|
| 10 | 4 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. | BI01010001010000000000000515BI0100001121 | 24 | Mtr. |
|---|
| 11 | 5 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ sub main wiring/ cable as required. | BI01010001010000000000000515BI0100001122 | 18 | Mtr. |
|---|
| 12 | 6 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. | BI01010001010000000000000515BI0100001123 | 4 | Each |
|---|
| 13 | 7 | Supplying and fixing 8 way double door, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) | BI01010001010000000000000515BI0100001124 | 3 | Each |
|---|
| 14 | 8 | Supplying and fixing 4 way (4 + 12), Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required of make C&S/STANDARD/HAVELLS/LeGrand. (But without MCB/RCCB/Isolator) | BI01010001010000000000000515BI0100001125 | 1 | Each |
|---|
| 15 | 9 | Supplying and fixing of following rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. of make HAVELLS/STANDARD | BI01010001010000000000000515BI0100001126 | | |
|---|
| 16 | 9.1 | Single pole 10/20 AMP | BI01010001010000000000000515BI0100001127 | 15 | Each |
|---|
| 17 | 9.2 | Single Pole & neutral 32 AMP | BI01010001010000000000000515BI0100001128 | 4 | Each |
|---|
| 18 | 10 | Supplying and fixing 5/6 amps switch make Havells/Anchor piano type/tumbler switch/ socket on the existing switch box/ cover including connections etc. as required. | BI01010001010000000000000515BI0100001129 | 30 | Each |
|---|
| 19 | 11 | Replacement of the existing unserviceable phenolic laminated sheet 3 mm thick i/c cutting. Drilling and fixing of piano type switch/socket i/c interconnections etc. as reqd. | BI01010001010000000000000515BI0100001130 | 4000 | sq.cm |
|---|
| 20 | 12 | Supply of following type of XLPE POWER CABLE of 1.1 kv grade armoured Al. cable compulsory ISI mark confirming to IS:7098/ PART –I / 88 with amendment no.1 of make POLYCAB/HAVELLS/MESCAB as required. | BI01010001010000000000000515BI0100001131 | | |
|---|
| 21 | 12.1 | CABLE SIZE 4 X 16 SQ.MM | BI01010001010000000000000515BI0100001132 | 130 | Mtr. |
|---|
| 22 | 12.2 | CABLE SIZE 2 X 16 SQ.MM | BI01010001010000000000000515BI0100001133 | 150 | Mtr. |
|---|
| 23 | 12.3 | CABLE SIZE 2 X 10 SQ.MM | BI01010001010000000000000515BI0100001134 | 200 | Mtr. |
|---|
| 24 | 13 | Laying of one No. PVC insulated & PVC sheathed/XLPE power cable of 1.1KV grade of following size direct in ground i/c excavation, sand cushioning, protective covering and refilling the trench etc. as reqd. | BI01010001010000000000000515BI0100001135 | | |
|---|
| 25 | 13.1 | upto 35 sq mm | BI01010001010000000000000515BI0100001136 | 90 | Mtr. |
|---|
| 26 | 14 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade up to 35 sq.mm in the existing RCC/ HUME/ METAL pipe as required. | BI01010001010000000000000515BI0100001137 | 10 | Mtr. |
|---|
| 27 | 15 | Laying and fixing of one No. PVC insulated & PVC sheathed/XLPE al conductor cable of 1.1KV grade Upto 35 sq. mm (clamped with 1mm thick saddle) on the wall surface as reqd. | BI01010001010000000000000515BI0100001138 | 380 | Mtr. |
|---|
| 28 | 16 | Supplying and fixing of light class G.I. pipe of 50 mm dia.(nominal) 3 metres length along the pole for protection of under ground cable as required. | BI01010001010000000000000515BI0100001139 | 1 | Each |
|---|
| 29 | 17 | Supplying, installation, testing and commissioning of LED luminaries fitting 120 watt crompton make LFLN-120-CDL/60 ncluding all accessories i.e., installation of Led tube on wall/truss with round block, screw etc as required. | BI01010001010000000000000515BI0100001140 | 3 | Each |
|---|
| 30 | 18 | S/I/T/C of 18W LED tube light fitting of make Crompton/Philips catalog no. LCTL-18-CDL (crompton make) including all accessories i.e., installation of Led tube on wall/truss with round block, screw etc as required. | BI01010001010000000000000515BI0100001141 | 24 | Each |
|---|
| 31 | 19 | Supply of LED luminaire comprises of a box type channel, CRCA housing cover with prewired accessories. 1200mm, 2x16 W LED lamp to be directly fitted in the luminaire IGP132LT8-16 of make CROMPTON or equivelant make of Phillips/Havells complete with two NOs 1200mm LED tube rod of make Crompton/Phillips/Havells make | BI01010001010000000000000515BI0100001142 | 11 | Each |
|---|
| 32 | 20 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent/LED fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. | BI01010001010000000000000515BI0100001143 | 11 | Each |
|---|
| 33 | 21 | Supply of LED street light fitting of 72 watts, AC 240 volts of make Crompton catalog no. LSTP-72-CDL of Pressure die cast Al. housing or its equiavlent of make HPL/Philips complete with all accessories etc. | BI01010001010000000000000515BI0100001144 | 4 | Each |
|---|
| 34 | 22 | Supply of LED street light fitting of 45 watts, AC 240 volts of make Crompton catalog no. LSTS-45-CDL-1 of Pressure die cast Al. housing or its equiavlent of make HPL/Philips complete with all accessories etc (i/c credit for dismanted material) | BI01010001010000000000000515BI0100001145 | 20 | Each |
|---|
| 35 | 23 | Tightning of ACSR conductor of 7/2.11 mm to 7/3.00mm diameter including binding etc as required. | BI01010001010000000000000515BI0100001146 | 165 | Kg |
|---|
| 36 | 24 | Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required | BI01010001010000000000000515BI0100001147 | 27 | Each |
|---|
| 37 | 25 | I/T/C of prewired street light fittings complete with all accessories on the existing G.I. pipe bracket on pole /wall including wiring & connections as required. | BI01010001010000000000000515BI0100001148 | 27 | Each |
|---|
| 38 | 26 | P/F of cable termination of M.S. box of size 15cm X 15cm X 10 cm with compression termination arrangements, 6-10 Amp SP MCB and double natural link etc as required. | BI01010001010000000000000515BI0100001149 | 12 | Each |
|---|
| 39 | 27 | Providing and fixing 100 Amp rating, 30 KA breaking capacity and Four Pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required of make STANDARD/Havells/L&T/C&S | BI01010001010000000000000515BI0100001150 | 1 | Each |
|---|
| 40 | 28 | Providing and fixing 200 Amp rating, 36 KA breaking capacity and Four Pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required of make STANDARD/Havells/L&T/C&S | BI01010001010000000000000515BI0100001151 | 1 | Each |
|---|
| 41 | 29 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. | BI01010001010000000000000515BI0100001152 | | |
|---|
| 42 | 29.1 | 2 X 10 sq. mm (19mm) | BI01010001010000000000000515BI0100001153 | 2 | Each |
|---|
| 43 | 29.2 | 2 X 16 sq. mm (22mm) | BI01010001010000000000000515BI0100001154 | 2 | Each |
|---|
| 44 | 29.3 | 4 X 16 sq. mm (28mm) | BI01010001010000000000000515BI0100001155 | 2 | Each |
|---|
| 45 | 30 | Less credit for dismantaled old damaged steel conduit and scrap | BI01010001010000000000000515BI0100001156 | | |
|---|
| 46 | 30.1 | 20 mm | BI01010001010000000000000515BI0100001157 | 40 | Mtr. |
|---|
| 47 | 30.2 | 25 mm | BI01010001010000000000000515BI0100001158 | 15 | Mtr. |
|---|
| 48 | 31 | Less credit for dismantaled old damaged 8 way MCB DB | BI01010001010000000000000515BI0100001159 | 3 | Each |
|---|
| 49 | 32 | Less credit for dismantaled old damaged 4+12 way MCB DB | BI01010001010000000000000515BI0100001160 | 1 | Each |
|---|
| 50 | 33 | Less credit for dismantaled old damaged Single pole MCB 6 to 32 Amp | BI01010001010000000000000515BI0100001161 | 15 | Each |
|---|
| 51 | 34 | Less credit for dismantaled old damaged 5/6Amp piano type switch | BI01010001010000000000000515BI0100001162 | 30 | Each |
|---|
| 52 | 35 | Less credit for dismantaled old damaged phenolic sheet and scrap | BI01010001010000000000000515BI0100001163 | 4000 | sq.cm |
|---|