Repair/Maintenance Of Electric And Plc Based Steam Bath , Sauna Bath Plants , Geysers , Solar Water Heater And Allied Works Under Ge ( Cme ) Kirkee
Tender Value
8 Lakhs
Estimated cost
Bid Submission
04 Feb 2020
0 days left
EMD
16000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Garrison Engineer (CME) Kirkee → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Repair/Maintenance Of Electric And Plc Based Steam Bath , Sauna Bath Plants , Geysers , Solar Water Heater And Allied Works Under Ge ( Cme ) Kirkee
BOQ
| Name of Work: Repair/maintenance of electric and PLC based steam bath, sauna bath plants, geysers, solar water heater and allied works under GE (CME) Kirkee | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | M & L for servicing solar Flat Plate collector by removing the flange plates, cleaning the collectors internally by using descaling solution, removing the blockages in the collectors complete and refixing the flange plates, testing for satisfactory function all as specified and directed. | 15 | Each Job | |
| 2 | 2 | M & L for sevicing solar manifold and tank by removing all the tubes in the monifold, cleaning the tubes internally, removing the blockages in the tubes and cleaning the tank and removing all the impurities, assembling and testing for satisfactory funtion all as specified and directed. | 10 | Each Job | |
| 3 | 3 | S & F Flat Plate collector Tank 100 LPD comprising of 2.5 mm GI/0.5 mm SS304 with rockwool insulation of 50 mm including aluminium cladding and removal of old unserviceable tank complete all as specified and directed. | 2 | Each | |
| 4 | 4 | S & F flange plates of size 25 mm dia suitable for flat plate collectors including taking down old unseviceable flange plate all specified and directed. | 8 | Each | |
| 5 | 5 | S & F Flat Plate collector Tank 200 LPD comprising of 2.5 mm GI/0.5 mm SS304 with rockwool insulation of 50 mm including aluminium cladding and removal of old unserviceable tank complete all as specified and directed. | 2 | Each | |
| 6 | 6 | S & F flexible heat resistance rubber pipe (from inter connect plate collector to hot water tank) of size 25 mm to 32 mm dia etc with fixing clamp etc complete all as specified. | 10 | Each | |
| 7 | 7 | Taking down the collector from its position, removing the top glass of collector and carry out welding/brazing work to the collector and arresting the leakages in the collector, refixing top glass back, testing for satisfactory function all as specified and directed. | 2 | Each Job | |
| 8 | 8 | Taking down the old unserviceable solar flat plate collector by disconecting flange plates and rubber hose pipes and replacing with new flat plate collector of same size and model, connecting flange plates and rubber hose complete, testing for proper functioning all as specified and directed. | 2 | Each Job | |
| 9 | 9 | S & F including finishing, sauna wooden R-11 grade insulation 40 kg density with aluminium foil complete all as specified and directed by Engr-In-Charge\nNote :- Size of wooden sheet 4 inch X 12 inch X 12 mm thickness will be considered for the work | 200 | Sqm | |
| 10 | 10 | M & L for submain wiring with two runs of 6 sq mm single core multi stranded FRLS PVC insulated and unsheathed copper conductor (red for phase and black for neutral) of grade 1100 volts and including electrical grade PVC casing caping of desired colour not less than 1.2 mm and 25 mm wide & 2.5 sq mm copper conductor cable FRLS PVC insulated unsheathed green coloured for earthing with complete accessories duly connected with earth dolly complete all as specified and as directed including taking down old wiring.\nNote :- Two run of 6 Sqmm, and one run of 2.5 Sqmm and one run of casing caping 25mm thick shall be measured as one length | 150 | RM | |
| 11 | 11 | Steam Bath : Checking of electrical wire connection , level sensors, Heaters coil, earthing leakage, electronic circuits & control panel & safety arrangements of the water level & units. Cleaning the sensors, deposition of hard water tank & electrical, pneumatic valve. Proper insulation for the boilers including replacement of defective spares and fixing the same with new including testing one etc complete.\nNote - \n(a) Contractor has to visit the plant once in a month and carry out comprehensive maintenance as directed by Engr-in-Charge.\n(b) During emergency contractor has to visit the plant to rectify the fault without any extra cost to the Govt.\n(c) Any spares required during comprehensive maintenance and during emergency repairs shall be measured under respective item as \" Supply only) (d) Contractor will employed one Skilled Technician and one helper to ckecking & rectifying the complaints. | 11 | Each | |
| 12 | 12 | Sauna Bath :- Checking of the heater coil, electronic temp control, calibrating temp, Accuracy, safety cut off the heater & cleaning the sensors of the electronic devices / equipments etc including replacement of defective spares and fixing the same with new including testing etc complete. \nNote -\n(a) Contractor has to visit the plant once in a month and carry out comprehensive maintenance as directed by Engr-in-Charge.\n(b) During emergency contractor has to visit the plant to rectify the fault without any extra cost to the Govt.\n(c) Any spares required during comprehensive maintenance and during emergency repairs shall be measured under respective item as \" Supply only) \n(d) Contractor will employed one Skilled Technician and one helper to ckecking & rectifying the complaints. | 11 | Each Job | |
| 13 | 13 | Supply only 15 PSI safety valve (Pressure relief valve)\n | 4 | Each | |
| 14 | 14 | Supply only 240 V 5 amps glass fuse | 4 | Each | |
| 15 | 15 | Supply only auto drain solenoid valve 12 volts 6 watts for steam bath. | 4 | Each | |
| 16 | 16 | Supply only water inlet solenoid valve 12 volt 6 watts for steam bath | 4 | Each | |
| 17 | 17 | Supply only Boiler insulation glass wool 25mm thick 40 Kg density with aluminium foil for one steam bath approx 3 Kg\n | 2 | Job | |
| 18 | 18 | Supply only steam water level circuit board & main relay board for steam bath. | 2 | Each | |
| 19 | 19 | Supply only steam generator power heating element 3000 watts for steam bath | 4 | Each | |
| 20 | 20 | Supply only sauna bath heating element 2000 Watts for sauna bath | 4 | Each | |
| 21 | 21 | Supply only mild steel powder coated exterior body including provision of analog ammeter, voltmeter LED indicators complete all as speciied and directed for steam bath. | 1 | Each | |
| 22 | 22 | Supply only high limit temperature (i.e 105 degree) switch thermostat for steam bath/sauna bath | 2 | Each | |
| 23 | 23 | Supply only stainless steel boiler tank as per existing make | 2 | Each | |
| 24 | 24 | Supply only water level sensor with Teflon collar & S/S No. Electrodes. | 2 | Each | |
| 25 | 25 | Supply only Temperature sensor including extension wire of length 6 metre for steam bath | 2 | Each | |
| 26 | 26 | Supply only Digital Control steam processor circuit board Model F-65/F-95 for steam/Sauna bath. \n | 2 | Each | |
| 27 | 27 | Supply only Digital Control panel ABS plastic cover for stam bath/souna bath.\n | 2 | Each | |
| 28 | 28 | Supply only Digital Control Key pad ovelay cover THD85E for steam bath.\n | 2 | Each | |
| 29 | 29 | Supply only step down Transformer with dual output primary 230 V and secondary 35 Volt 5 Amps for steam bath. | 2 | Each | |
| 30 | 30 | Supply only Mains power Terminal 4 way connector 63 amps | 2 | Each | |
| 31 | 31 | Supply only steam contactor 230 V coil 63 amps 3 phase 440 volt for steam plant. | 2 | Each | |
| 32 | 32 | Supply only silicon heater washer | 2 | Each | |
| 33 | 33 | Supply only power contactor 40 Amps 440 volts, 50 Hz | 2 | Each | |
| 34 | 34 | Supply only temperature thermostat range 30 to 110 degrees. | 2 | Each | |
| 35 | 35 | Supply only 4 way channel terminal strip connector 32 Amps. | 2 | Each | |
| 36 | 36 | Supply only high limit upto 95o c temprature switch 40 Amps rating for steam bath. | 2 | Each | |
| 37 | 37 | Supply only in repairs electronic sauna room temperature controller. | 2 | Each | |
| 38 | 38 | Supply only low density industrial Sauna heating element S/S, 316 Grade, 2000 watt. | 8 | Each | |
| 39 | 39 | Supply only flame proof wires 6 Sqmm for Sauna heater/steam bath. | 30 | RM | |
| 40 | 40 | Supply only Sauna room light switch 5 Amps. | 2 | Each | |
| 41 | 41 | Supply only Sauna room light switch dimmer | 2 | Each | |
| 42 | 42 | Comprehensive maintenance of storage type electric water heater (geyser) of capacity 25 to 50 litres comprising of the following tasks at different locations including taking down, transportation to work shop ,opening the geyser, replacement of defective spares and reinstalling the same including testing as directed by Engineer-in-charge. \nMake: Bajaj, Ditz, Primer, Galco, Racold or any other make. Note : Contractor will employed one Skilled Technician and one helper to ckecking & rectifying the diffect/complaints. | 60 | Each Job | |
| 43 | 42.1 | (a) Inspection of geysers includes taking down, transporting to works shop for repair, (dismantling) opening descaling, brushing cleaning of storage tank\n(b) Check and correct earth continuity of electrical items\n(c) Replacement of neon lamp / indicator lamp if defective.\n(d) Inspect over flow/vent pipes and remove blockage/ obstructions if any. \n(e) Examine water tightness tank after cleaning and necessary measures to make the same water tight if not. | |||
| 44 | 42.2 | (f) Check thermostat for its proper functioning \n(g) Visual examination of fusible plug to ensure its intactness.\n(h) Checking of dead weight type high pressure release valve ( PRV ) by removing dead weight protection cleaning the seat and ensuring that the vent hole is not blocked / chocked | |||
| 45 | 42.3 | j) Descalling of the immersion type heating element and cleaning with diluted hydrochloric acid and refixing.\nk) Checking and adjustments of pressure reducing valves, carrying out operation of all stop cocks & ensure free movement of all working parts.\nl) Replacement of the rubber / PVC gasket to ensure water tightness | |||
| 46 | 42.4 | m) Testing of Geysers after repairs\nn) Replacement of defective components such as thermostat safety valves fusible plug, Heating elements, storage tank apparatus plate etc.\nNote:- Spare components will be measured and paid separately as supply only under relevent item of Sch 'A'. These parts shall be of the same make of which the geyser is in repair. | |||
| 47 | 43 | Repair/checking to storage type water heater geyser of any capacity including replacement of required spares such as heating element thermostat, indicator, fusible plug dead weight,hot/cold water hose pipes incl any other etc repairs work at different locations at CME all as specified and directed by Engr in charge for the Make: Bajaj, Ditz, primer, galco, recold or any other make). Note : (i) Spare components will be mesaured and paid seperately.(ii) Each Job Complete when Checking & rectification of minimum 5 Geysers per day/Job as to the complaints on register & complaints logged on line (visit compulsary) (iii) Contractor will employed one Skilled Technician and one helper to ckecking & rectifying the complaints. | 300 | Each Job | |
| 48 | 44 | Supply only aparatus plate for geyser 25 Ltrs capacity | 10 | Each | |
| 49 | 45 | Supply only aparatus plate for geyser 50 Ltrs capacity | 4 | Each | |
| 50 | 46 | Supply only non return valve(NRV) brass of 15mm bore, after dismantling old unserviceable NRV of any size all as specified and directed. | 10 | Each | |
| 51 | 47 | Taking down loose geysers of any capacity from wall & shifting to new place within 1 to 1.5m distance (available in same location) , refixing the geysers complete with grouting of bolts & all necessary pipe connections and making good the disturbed wall surfaces all as directed.\nNote :- GI tubing if required shall be measured and paid separately. | 20 | Each | |
| 52 | 48 | M & L to repair the leakge of copper inner tank of geysers of any capacity by gas welding/brazing for water tightness complete and test under pressure. | 20 | Each | |
| 53 | 49 | S & F GI tubing (Medium grade) with all fitting and fixed to complete on wall and ceiling or laid on floor of size 15mm bore all as specified and directed. | 60 | RM | |
| 54 | 50 | S & F mild steel bottom/top covers for 25-50 litre capacity geysers. | 10 | Each | |
| 55 | 51 | S & F gasket rubber ring for heater plate of any size geyser. | 80 | Each | |
| 56 | 52 | M&L for sub main wiring with two run of 4 sqmm single core multi stranded PVC insulated and unsheathed copper conductor (red for phase and black for neutral) of grade 1100 volt FRLSH cable in and including 1100 volt electrical grade PVC casing caping of desired colour not less than1.2 mm thick and 25 mm wide & 4 sqmm copper conductor cable PVC unsheathed green coloured for earthing with complete accessories duly connected with earth dolly complete all as specified and as directed incl taking down old unserviceable one. | 285 | RM |
AI Tender Summary
Tender Timeline
Jan 22, 2020
11:30 IST
Tender Published
Tender notice published.
CompletedFeb 04, 2020
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedFeb 06, 2020
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender