Construction And Renovation Works Of Nabajyoti College , Kalgachia , Barpeta
Tender Value
1.60 Crore
Estimated cost
Bid Submission
06 Feb 2020
0 days left
EMD
3.20 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Nabajyoti College, Kalgachia, Barpeta → Assam
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction And Renovation Works Of Nabajyoti College , Kalgachia , Barpeta
BOQ
| Name of Work: Construction and Renovation works of Nabajyoti College, Kalgachia, Barpeta | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Construction of Proposed Three Storied (G+2) R.C.C. Digital Class Room, Computer Room & Class Room | Anx-A_1 | ||
| 2 | 2 | Ground Floor: | Anx-A_2 | ||
| 3 | 3 | EARTH WORK | Anx-A_3 | ||
| 4 | 4 | Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. | Anx-A_4 | ||
| 5 | 5 | (A) Up to a depth of 2.00m below the existing ground level. | Anx-A_5 | ||
| 6 | 6 | (a) In ordinary soil | Anx-A_6 | 365.29 | Cum |
| 7 | 7 | PLINTH FILLING | Anx-A_7 | ||
| 8 | 8 | Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. | Anx-A_8 | ||
| 9 | 9 | (c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading. | Anx-A_9 | 199.9 | Cum |
| 10 | 10 | ANTI TERMITE TREATMENT | Anx-A_10 | ||
| 11 | 11 | Pre construction anti - termite treatment at the bottom of foundation pits and walls on either side up to a height of 300mm from bottom of the excavation made for column plinth beam, wall, trenches etc. by applying the emulsion @ 5 (five) litres per square meter of the surface area before starting construction work (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. | Anx-A_11 | ||
| 12 | 12 | a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution. | Anx-A_12 | 227.06 | Sqm |
| 13 | 13 | Pre construction anti - termite treatment by applying in the junction of walls, column with the floor before laying floor and after operation of item no. 26.1.3 above making a channel 30mmx30mm all over the walls and making rod holes @ 150mm apart up to ground level below and applying emulsion @ 11 litres per square meter of vertical plinth wall surface inside the building so as to soak the soil with the emulsion up to the ground level and refill the holes and channel with the original materials obtained in making channels (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. | Anx-A_13 | ||
| 14 | 14 | a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution. | Anx-A_14 | 263.51 | Sqm |
| 15 | 15 | Plain C.C. Prop. 1:3:6 | Anx-A_15 | ||
| 16 | 16 | Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). | Anx-A_16 | ||
| 17 | 17 | (a) In prop 1cement: 3 sand :6 coarse aggregate by volume | Anx-A_17 | 17.02 | Cum |
| 18 | 18 | Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed. | Anx-A_18 | 10.56 | Sqm |
| 19 | 19 | Plain cement concrete floor base in prop1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. complete. | Anx-A_19 | ||
| 20 | 20 | b) 50mm thick | Anx-A_20 | 297.57 | Sqm |
| 21 | 21 | REINFORCED CEMENT CONCRETE WORKS | Anx-A_21 | ||
| 22 | 22 | Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) | Anx-A_22 | ||
| 23 | 23 | (I) Using Mixer Machine | Anx-A_23 | ||
| 24 | 24 | (A) In substructure up to plinth level | Anx-A_24 | ||
| 25 | 25 | Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. | Anx-A_25 | ||
| 26 | 26 | N) Without using admixture, plasticiser | Anx-A_26 | ||
| 27 | 27 | b) M20 grade concrete or Prop. 1:1.5:3 | Anx-A_27 | 71.95 | Cum |
| 28 | 28 | (B) In super structure from plinth level up to 1st floor level. | Anx-A_28 | ||
| 29 | 29 | N) Without using admixture, plasticiser | Anx-A_29 | ||
| 30 | 30 | ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. | Anx-A_30 | ||
| 31 | 31 | N) Without using admixture, plasticiser | Anx-A_31 | ||
| 32 | 32 | b) M20 grade concrete or Prop. 1:1.5:3 | Anx-A_32 | 81.08 | Cum |
| 33 | 33 | TIMBER SHUTTERING (FORMWORK) | Anx-A_33 | ||
| 34 | 34 | Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: | Anx-A_34 | ||
| 35 | 35 | Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. | Anx-A_35 | ||
| 36 | 36 | (b) Using 25mm thick plank | Anx-A_36 | 52.76 | Sqm |
| 37 | 37 | Sides of tie beams, grade beams etc. at or below ground level. | Anx-A_37 | ||
| 38 | 38 | (b) Using 25mm thick plank | Anx-A_38 | 105.75 | Sqm |
| 39 | 39 | Columns, Pillars, Posts & Strut | Anx-A_39 | ||
| 40 | 40 | (a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face | Anx-A_40 | ||
| 41 | 41 | (ii) Using 25mm thick plank | Anx-A_41 | 252.3 | Sqm |
| 42 | 42 | Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. | Anx-A_42 | ||
| 43 | 43 | (a) For depth not exceeding 1.0M. | Anx-A_43 | ||
| 44 | 44 | (ii) Using 25mm thick plank | Anx-A_44 | 200.56 | Sqm |
| 45 | 45 | Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. | Anx-A_45 | ||
| 46 | 46 | (a) Floors etc. upto 200mm in thickness. | Anx-A_46 | ||
| 47 | 47 | (ii) Using 25mm thick plank | Anx-A_47 | 376.05 | Sqm |
| 48 | 48 | Staircase with sloping or stepped soffits including risers and stringers but excluding Landing. (Using 38mm thick plank) | Anx-A_48 | 23.15 | Sqm |
| 49 | 49 | BRICK WORKS | Anx-A_49 | ||
| 50 | 50 | Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. | Anx-A_50 | ||
| 51 | 51 | (a) Brick on flat soling. | Anx-A_51 | 493.59 | Sqm |
| 52 | 52 | Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. | Anx-A_52 | ||
| 53 | 53 | (I) In Sub-structure upto plinth level including dewatering if necessary | Anx-A_53 | ||
| 54 | 54 | (b) In proportion 1:4. | Anx-A_54 | 25.62 | Cum |
| 55 | 55 | 112 mm thick 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) | Anx-A_55 | ||
| 56 | 56 | (a) In cement mortar in proportion 1:4. \n(1 cement:4 sand) | Anx-A_56 | 251.31 | Sqm |
| 57 | 57 | FLOORINGING & SKIRTING | Anx-A_57 | ||
| 58 | 58 | Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) | Anx-A_58 | ||
| 59 | 59 | a) Normal range \nSomany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make | Anx-A_59 | ||
| 60 | 60 | ii) Of size 600mmx600mm and above | Anx-A_60 | 297.57 | Sq.m |
| 61 | 61 | Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor. | Anx-A_61 | ||
| 62 | 62 | (a) 15 mm thick | Anx-A_62 | 61.7 | Sq.m |
| 63 | 63 | PLASTERING | Anx-A_63 | ||
| 64 | 64 | 15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. | Anx-A_64 | ||
| 65 | 65 | A) On rough side | Anx-A_65 | ||
| 66 | 66 | d) In cement mortar 1:6 | Anx-A_66 | 663.04 | Sqm |
| 67 | 67 | B) On fair side | Anx-A_67 | ||
| 68 | 68 | d) In cement mortar 1:6 | Anx-A_68 | 418.13 | Sqm |
| 69 | 69 | WOODWORK | Anx-A_69 | ||
| 70 | 70 | Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified. | Anx-A_70 | ||
| 71 | 71 | (a) With sal wood | Anx-A_71 | 0.33 | Cum |
| 72 | 72 | Providing, fitting and fixing factory made Santro Flush door shutters having core & cross bands fabricated from seasoned 1st class timber, 25mm core battens, 2.5mm to 3.5mm uniformly thick cross bands, styles & rails made from hardwood timber of width not less than 50mm, fixed to the door frames (chowkath) with necessary hinges, screws, bolts etc. as specified and directed at all levels (Door fixtures and fittings to be measured and paid seperately.) | Anx-A_72 | ||
| 73 | 73 | (b) 35mm thick | Anx-A_73 | 13.93 | Sqm |
| 74 | 74 | M. S. GRILL | Anx-A_74 | ||
| 75 | 75 | Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws. | Anx-A_75 | ||
| 76 | 76 | I . Plain grill | Anx-A_76 | ||
| 77 | 77 | (c) Fixed to Brickwork/P.C.C/R.C.C. | Anx-A_77 | 598.08 | Kg |
| 78 | 78 | CEMENT PAINT & PRIMER | Anx-A_78 | ||
| 79 | 79 | a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth. | Anx-A_79 | 418.13 | Sqm |
| 80 | 80 | Finishing old / new wall with water proofing weather coat smooth anti-fungal exterior painting of approved make of Berger paint of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats) | Anx-A_80 | 418.13 | Sqm |
| 81 | 81 | WALL PUTTY WORK & PAINTING | Anx-A_81 | ||
| 82 | 82 | Providing two coats of J.K Wall Putty ( White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm) | Anx-A_82 | 663.04 | Sqm |
| 83 | 83 | Area same of inner side & outer plaster area | Anx-A_83 | ||
| 84 | 84 | 1 x Area 663.04 = 663.04 Sqm | Anx-A_84 | ||
| 85 | 85 | Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. | Anx-A_85 | ||
| 86 | 86 | (a) Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) | Anx-A_86 | 663.04 | Sqm |
| 87 | 87 | WOOD PRIMER & PAINTING | Anx-A_87 | ||
| 88 | 88 | Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting. | Anx-A_88 | ||
| 89 | 89 | (b) With ready mixed paint , wood primer (white). | Anx-A_89 | 125.9 | Sqm |
| 90 | 90 | Painting one coat (excluding priming coat) on old wood and wood based surfaces with enamel paint to give an even shade including cleaning the surface of all dirt, dust and other foreign matter sand papering and stopping. | Anx-A_90 | ||
| 91 | 91 | (i) Surfaces over 100mm in width or girth. | Anx-A_91 | ||
| 92 | 92 | b) High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac). | Anx-A_92 | 125.9 | Sqm |
| 93 | 93 | Area same as of wood primer area | Anx-A_93 | ||
| 94 | 94 | DOOR AND WINDOW FITTINGS | Anx-A_94 | ||
| 95 | 95 | Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) | Anx-A_95 | ||
| 96 | 96 | a) Sliding door bolts | Anx-A_96 | ||
| 97 | 97 | i) 300 mm x 16 mm | Anx-A_97 | 7 | Each |
| 98 | 98 | b) Tower bolts | Anx-A_98 | ||
| 99 | 99 | ii) 250mm x 12mm | Anx-A_99 | 14 | Each |
| 100 | 100 | iii) 200mm x 12mm | Anx-A_100 | 7 | Each |
| 101 | 101 | c) Door handles | Anx-A_101 | ||
| 102 | 102 | iii) 150mm | Anx-A_102 | 14 | Each |
| 103 | 103 | REINFORCEMENT | Anx-A_103 | ||
| 104 | 104 | Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.\n(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) | Anx-A_104 | ||
| 105 | 105 | a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL | Anx-A_105 | ||
| 106 | 106 | (ii)Super Ductile (SD) TMT reinforcement bars | Anx-A_106 | 135.07 | Qtl |
| 107 | 107 | Providing, fitting and fixing steel windows/ ventilators (openable) of standard rolled steel sections as per relevant I.S. Code-1038 joints mitred and welded with 15mmx3mmx100mm lugs embedded in cement concrete block of M-10 grade including providing and fixing of projecting hinges (not more than 65mm and not less than 15mm wide) bolting device and steel handles, peg stays of 300mm long etc. complete as per drawing including applying a priming coat of red-lead paint. | Anx-A_107 | 41.97 | Sqm |
| 108 | 108 | PLINTH PROTECTION AND DRAIN | Anx-A_108 | ||
| 109 | 109 | Providing plinth protection with bricks flat laid in cement mortar 1: 4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish. | Anx-A_109 | 53.42 | Sqm |
| 110 | 110 | Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. | Anx-A_110 | 79 | Rm |
| 111 | 111 | 1st Floor: | Anx-A_111 | ||
| 112 | 112 | REINFORCED CEMENT CONCRETE WORKS | Anx-A_112 | ||
| 113 | 113 | Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) | Anx-A_113 | ||
| 114 | 114 | (I) Using Mixer Machine | Anx-A_114 | ||
| 115 | 115 | (B) In super structure from plinth level up to 1st floor level. | Anx-A_115 | ||
| 116 | 116 | N) Without using admixture, plasticiser | Anx-A_116 | ||
| 117 | 117 | ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. | Anx-A_117 | ||
| 118 | 118 | N) Without using admixture, plasticiser | Anx-A_118 | ||
| 119 | 119 | b) M20 grade concrete or Prop. 1:1.5:3 | Anx-A_119 | 80.77 | Cum |
| 120 | 120 | Extra over item Nos. 2.2.1 (I) (B), above for each subsequent floor or part thereof above the 1st floor level. | Anx-A_120 | 80.77 | Cum |
| 121 | 121 | TIMBER SHUTTERING (FORMWORK) | Anx-A_121 | ||
| 122 | 122 | Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: | Anx-A_122 | ||
| 123 | 123 | Columns, Pillars, Posts & Strut | Anx-A_123 | ||
| 124 | 124 | (a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face | Anx-A_124 | ||
| 125 | 125 | (ii) Using 25mm thick plank | Anx-A_125 | 159.39 | Sqm |
| 126 | 126 | Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. | Anx-A_126 | ||
| 127 | 127 | (a) For depth not exceeding 1.0M. | Anx-A_127 | ||
| 128 | 128 | (i) Using 38mm thick plank | Anx-A_128 | 200.56 | Sqm |
| 129 | 129 | Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. | Anx-A_129 | ||
| 130 | 130 | (a) Floors etc. upto 200mm in thickness. | Anx-A_130 | ||
| 131 | 131 | (i) Using 38mm thick plank | Anx-A_131 | 376.05 | Sqm |
| 132 | 132 | Staircase with sloping or stepped soffits including risers and stringers but excluding Landing. (Using 38mm thick plank) | Anx-A_132 | 20.69 | Sqm |
| 133 | 133 | BRICK WORKS | Anx-A_133 | ||
| 134 | 134 | 112 mm thick 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) | Anx-A_134 | ||
| 135 | 135 | (a) In cement mortar in proportion 1:4. \n(1 cement:4 sand) | Anx-A_135 | 267.39 | Sqm |
| 136 | 136 | FLOORINGING & SKIRTING | Anx-A_136 | ||
| 137 | 137 | Cement concrete works in topping 1:1:2 (1cement :1sand :2 graded aggregates on R.C.C floor, tread and rise of steps finished with a floating coat of neat cement using cement slurry for bond @ 2.75 kg.of cement per sq. m. of floor to be laid in panels including curing complete as directed. | Anx-A_137 | ||
| 138 | 138 | (a) 15 mm thick | Anx-A_138 | 297.57 | Sq.m |
| 139 | 139 | PLASTERING | Anx-A_139 | ||
| 140 | 140 | 15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. | Anx-A_140 | ||
| 141 | 141 | A) On rough side | Anx-A_141 | ||
| 142 | 142 | d) In cement mortar 1:6 | Anx-A_142 | 678.14 | Sqm |
| 143 | 143 | B) On fair side | Anx-A_143 | ||
| 144 | 144 | d) In cement mortar 1:6 | Anx-A_144 | 428.58 | Sqm |
| 145 | 145 | WOODWORK | Anx-A_145 | ||
| 146 | 146 | Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified. | Anx-A_146 | ||
| 147 | 147 | (a) With sal wood | Anx-A_147 | 0.34 | Cum |
| 148 | 148 | Providing, fitting and fixing factory made Santro Flush door shutters having core & cross bands fabricated from seasoned 1st class timber, 25mm core battens, 2.5mm to 3.5mm uniformly thick cross bands, styles & rails made from hardwood timber of width not less than 50mm, fixed to the door frames (chowkath) with necessary hinges, screws, bolts etc. as specified and directed at all levels (Door fixtures and fittings to be measured and paid seperately.) | Anx-A_148 | ||
| 149 | 149 | (b) 35mm thick | Anx-A_149 | 13.93 | Sqm |
| 150 | 150 | M. S. GRILL | Anx-A_150 | ||
| 151 | 151 | Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws. | Anx-A_151 | ||
| 152 | 152 | I . Plain grill | Anx-A_152 | ||
| 153 | 153 | (c) Fixed to Brickwork/P.C.C/R.C.C. | Anx-A_153 | 598.14 | Kg |
| 154 | 154 | CEMENT PAINT & PRIMER | Anx-A_154 | ||
| 155 | 155 | a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth. | Anx-A_155 | 428.58 | Sqm |
| 156 | 156 | Finishing old / new wall with water proofing weather coat smooth anti-fungal exterior painting of approved make of Berger paint of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats) | Anx-A_156 | 428.58 | Sqm |
| 157 | 157 | WALL PUTTY WORK & PAINTING | Anx-A_157 | ||
| 158 | 158 | Providing two coats of J.K Wall Putty ( White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm) | Anx-A_158 | 678.14 | Sqm |
| 159 | 159 | Area same of inner side & outer plaster area | Anx-A_159 | ||
| 160 | 160 | 1 x Area 678.14 = 678.14 Sqm | Anx-A_160 | ||
| 161 | 161 | Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. | Anx-A_161 | ||
| 162 | 162 | (a) Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) | Anx-A_162 | 678.14 | Sqm |
| 163 | 163 | WOOD PRIMER & PAINTING | Anx-A_163 | ||
| 164 | 164 | Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting. | Anx-A_164 | ||
| 165 | 165 | (b) With ready mixed paint , wood primer (white). | Anx-A_165 | 125.9 | Sqm |
| 166 | 166 | Painting one coat (excluding priming coat) on old wood and wood based surfaces with enamel paint to give an even shade including cleaning the surface of all dirt, dust and other foreign matter sand papering and stopping. | Anx-A_166 | ||
| 167 | 167 | (i) Surfaces over 100mm in width or girth. | Anx-A_167 | ||
| 168 | 168 | b) High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac). | Anx-A_168 | 125.9 | Sqm |
| 169 | 169 | Area same as of wood primer area | Anx-A_169 | ||
| 170 | 170 | DOOR AND WINDOW FITTINGS | Anx-A_170 | ||
| 171 | 171 | Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) | Anx-A_171 | ||
| 172 | 172 | a) Sliding door bolts | Anx-A_172 | ||
| 173 | 173 | i) 300 mm x 16 mm | Anx-A_173 | 7 | Each |
| 174 | 174 | b) Tower bolts | Anx-A_174 | ||
| 175 | 175 | ii) 250mm x 12mm | Anx-A_175 | 14 | Each |
| 176 | 176 | iii) 200mm x 12mm | Anx-A_176 | 7 | Each |
| 177 | 177 | c) Door handles | Anx-A_177 | ||
| 178 | 178 | iii) 150mm | Anx-A_178 | 14 | Each |
| 179 | 179 | REINFORCEMENT | Anx-A_179 | ||
| 180 | 180 | Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.\n(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) | Anx-A_180 | ||
| 181 | 181 | a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL | Anx-A_181 | ||
| 182 | 182 | (ii)Super Ductile (SD) TMT reinforcement bars | Anx-A_182 | 85.69 | Qtl |
| 183 | 183 | Providing, fitting and fixing steel windows/ ventilators (openable) of standard rolled steel sections as per relevant I.S. Code-1038 joints mitred and welded with 15mmx3mmx100mm lugs embedded in cement concrete block of M-10 grade including providing and fixing of projecting hinges (not more than 65mm and not less than 15mm wide) bolting device and steel handles, peg stays of 300mm long etc. complete as per drawing including applying a priming coat of red-lead paint. | Anx-A_183 | 41.96 | Sqm |
| 184 | 184 | 2nd Floor | Anx-A_184 | ||
| 185 | 185 | REINFORCED CEMENT CONCRETE WORKS | Anx-A_185 | ||
| 186 | 186 | Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) | Anx-A_186 | ||
| 187 | 187 | (I) Using Mixer Machine | Anx-A_187 | ||
| 188 | 188 | (B) In super structure from plinth level up to 1st floor level. | Anx-A_188 | ||
| 189 | 189 | N) Without using admixture, plasticiser | Anx-A_189 | ||
| 190 | 190 | ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. | Anx-A_190 | ||
| 191 | 191 | N) Without using admixture, plasticiser | Anx-A_191 | ||
| 192 | 192 | b) M20 grade concrete or Prop. 1:1.5:3 | Anx-A_192 | 80.77 | Cum |
| 193 | 193 | Extra over item Nos. 2.2.1 (I) (B), above for each subsequent floor or part thereof above the 1st floor level. | Anx-A_193 | 80.77 | Cum |
| 194 | 194 | TIMBER SHUTTERING (FORMWORK) | Anx-A_194 | ||
| 195 | 195 | Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: | Anx-A_195 | ||
| 196 | 196 | Columns, Pillars, Posts & Strut | Anx-A_196 | ||
| 197 | 197 | (a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face | Anx-A_197 | ||
| 198 | 198 | (ii) Using 25mm thick plank | Anx-A_198 | 159.39 | Sqm |
| 199 | 199 | Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. | Anx-A_199 | ||
| 200 | 200 | (a) For depth not exceeding 1.0M. | Anx-A_200 | ||
| 201 | 201 | (i) Using 38mm thick plank | Anx-A_201 | 200.56 | Sqm |
| 202 | 202 | Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. | Anx-A_202 | ||
| 203 | 203 | (a) Floors etc. upto 200mm in thickness. | Anx-A_203 | ||
| 204 | 204 | (i) Using 38mm thick plank | Anx-A_204 | 376.05 | Sqm |
| 205 | 205 | Staircase with sloping or stepped soffits including risers and stringers but excluding Landing. (Using 38mm thick plank) | Anx-A_205 | 20.69 | Sqm |
| 206 | 206 | BRICK WORKS | Anx-A_206 | ||
| 207 | 207 | 112 mm thick 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) | Anx-A_207 | ||
| 208 | 208 | (a) In cement mortar in proportion 1:4. \n(1 cement:4 sand) | Anx-A_208 | 267.39 | Sqm |
| 209 | 209 | FLOORINGING & SKIRTING | Anx-A_209 | ||
| 210 | 210 | Cement concrete works in topping 1:1:2 (1cement :1sand :2 graded aggregates on R.C.C floor, tread and rise of steps finished with a floating coat of neat cement using cement slurry for bond @ 2.75 kg.of cement per sq. m. of floor to be laid in panels including curing complete as directed. | Anx-A_210 | ||
| 211 | 211 | (a) 15 mm thick | Anx-A_211 | 297.57 | Sq.m |
| 212 | 212 | PLASTERING | Anx-A_212 | ||
| 213 | 213 | 15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. | Anx-A_213 | ||
| 214 | 214 | A) On rough side | Anx-A_214 | ||
| 215 | 215 | d) In cement mortar 1:6 | Anx-A_215 | 678.14 | Sqm |
| 216 | 216 | B) On fair side | Anx-A_216 | ||
| 217 | 217 | d) In cement mortar 1:6 | Anx-A_217 | 428.58 | Sqm |
| 218 | 218 | WOODWORK | Anx-A_218 | ||
| 219 | 219 | Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified. | Anx-A_219 | ||
| 220 | 220 | (a) With sal wood | Anx-A_220 | 0.34 | Cum |
| 221 | 221 | Providing, fitting and fixing factory made Santro Flush door shutters having core & cross bands fabricated from seasoned 1st class timber, 25mm core battens, 2.5mm to 3.5mm uniformly thick cross bands, styles & rails made from hardwood timber of width not less than 50mm, fixed to the door frames (chowkath) with necessary hinges, screws, bolts etc. as specified and directed at all levels (Door fixtures and fittings to be measured and paid seperately.) | Anx-A_221 | ||
| 222 | 222 | (b) 35mm thick | Anx-A_222 | 13.93 | Sqm |
| 223 | 223 | M. S. GRILL | Anx-A_223 | ||
| 224 | 224 | Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws. | Anx-A_224 | ||
| 225 | 225 | I . Plain grill | Anx-A_225 | ||
| 226 | 226 | (c) Fixed to Brickwork/P.C.C/R.C.C. | Anx-A_226 | 598.14 | Kg |
| 227 | 227 | CEMENT PAINT & PRIMER | Anx-A_227 | ||
| 228 | 228 | a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth. | Anx-A_228 | 428.58 | Sqm |
| 229 | 229 | Finishing old / new wall with water proofing weather coat smooth anti-fungal exterior painting of approved make of Berger paint of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats) | Anx-A_229 | 428.58 | Sqm |
| 230 | 230 | WALL PUTTY WORK & PAINTING | Anx-A_230 | ||
| 231 | 231 | Providing two coats of J.K Wall Putty ( White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm) | Anx-A_231 | 678.14 | Sqm |
| 232 | 232 | Area same of inner side & outer plaster area | Anx-A_232 | ||
| 233 | 233 | 1 x Area 678.14 = 678.14 Sqm | Anx-A_233 | ||
| 234 | 234 | Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. | Anx-A_234 | ||
| 235 | 235 | (a) Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) | Anx-A_235 | 678.14 | Sqm |
| 236 | 236 | WOOD PRIMER & PAINTING | Anx-A_236 | ||
| 237 | 237 | Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting. | Anx-A_237 | ||
| 238 | 238 | (b) With ready mixed paint , wood primer (white). | Anx-A_238 | 125.9 | Sqm |
| 239 | 239 | Painting one coat (excluding priming coat) on old wood and wood based surfaces with enamel paint to give an even shade including cleaning the surface of all dirt, dust and other foreign matter sand papering and stopping. | Anx-A_239 | ||
| 240 | 240 | (i) Surfaces over 100mm in width or girth. | Anx-A_240 | ||
| 241 | 241 | b) High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac). | Anx-A_241 | 125.9 | Sqm |
| 242 | 242 | Area same as of wood primer area | Anx-A_242 | ||
| 243 | 243 | DOOR AND WINDOW FITTINGS | Anx-A_243 | ||
| 244 | 244 | Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) | Anx-A_244 | ||
| 245 | 245 | a) Sliding door bolts | Anx-A_245 | ||
| 246 | 246 | i) 300 mm x 16 mm | Anx-A_246 | 7 | Each |
| 247 | 247 | b) Tower bolts | Anx-A_247 | ||
| 248 | 248 | ii) 250mm x 12mm | Anx-A_248 | 14 | Each |
| 249 | 249 | iii) 200mm x 12mm | Anx-A_249 | 7 | Each |
| 250 | 250 | c) Door handles | Anx-A_250 | ||
| 251 | 251 | iii) 150mm | Anx-A_251 | 14 | Each |
| 252 | 252 | REINFORCEMENT | Anx-A_252 | ||
| 253 | 253 | Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.\n(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) | Anx-A_253 | ||
| 254 | 254 | a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL | Anx-A_254 | ||
| 255 | 255 | (ii)Super Ductile (SD) TMT reinforcement bars | Anx-A_255 | 85.69 | Qtl |
| 256 | 256 | Providing, fitting and fixing steel windows/ ventilators (openable) of standard rolled steel sections as per relevant I.S. Code-1038 joints mitred and welded with 15mmx3mmx100mm lugs embedded in cement concrete block of M-10 grade including providing and fixing of projecting hinges (not more than 65mm and not less than 15mm wide) bolting device and steel handles, peg stays of 300mm long etc. complete as per drawing including applying a priming coat of red-lead paint. | Anx-A_256 | 41.96 | Sqm |
| 257 | 257 | Electrification Lum-sum cost: Rs.525235.00 | Anx-A_257 | 1 | LS |
| 258 | 258 | Renovation / Upgradation of Existing Facilities | Anx-A_258 | ||
| 259 | 259 | Auditorium | Anx-A_259 | ||
| 260 | 260 | EARTH WORK | Anx-A_260 | ||
| 261 | 261 | Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. | Anx-A_261 | ||
| 262 | 262 | (A) Up to a depth of 2.00m below the existing ground level. | Anx-A_262 | ||
| 263 | 263 | (a) In ordinary soil | Anx-A_263 | 9.69 | Cum |
| 264 | 264 | Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. | Anx-A_264 | ||
| 265 | 265 | (a) Brick on flat soling. | Anx-A_265 | 83.32 | Sqm |
| 266 | 266 | Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). | Anx-A_266 | ||
| 267 | 267 | (b) In prop 1cement: 4 sand :8 coarse aggregate by volume | Anx-A_267 | 2.13 | Cum |
| 268 | 268 | Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.\n(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) | Anx-A_268 | ||
| 269 | 269 | a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL | Anx-A_269 | ||
| 270 | 270 | b) Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX)\n (For Assam Type Bldg., drain works,,retaining wall&boundary wall etc. . | Anx-A_270 | 5.63 | Qtl |
| 271 | 271 | Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) | Anx-A_271 | ||
| 272 | 272 | (I) Using Mixer Machine | Anx-A_272 | ||
| 273 | 273 | (A) In substructure up to plinth level | Anx-A_273 | ||
| 274 | 274 | Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. | Anx-A_274 | ||
| 275 | 275 | N) Without using admixture, plasticiser | Anx-A_275 | ||
| 276 | 276 | a) M15 grade concrete or Prop. 1:2:4 | Anx-A_276 | 4.36 | Cum |
| 277 | 277 | (B) In super structure from plinth level up to 1st floor level. | Anx-A_277 | ||
| 278 | 278 | ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. | Anx-A_278 | ||
| 279 | 279 | N) Without using admixture, plasticiser | Anx-A_279 | ||
| 280 | 280 | a) M15 grade concrete or Prop. 1:2:4 | Anx-A_280 | 2.9 | Cum |
| 281 | 281 | Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: | Anx-A_281 | ||
| 282 | 282 | Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. | Anx-A_282 | ||
| 283 | 283 | (b) Using 25mm thick plank | Anx-A_283 | 6 | Sqm |
| 284 | 284 | Sides of tie beams, grade beams etc. at or below ground level. | Anx-A_284 | ||
| 285 | 285 | (b) Using 25mm thick plank | Anx-A_285 | 17.72 | Sqm |
| 286 | 286 | Columns, Pillars, Posts & Strut | Anx-A_286 | ||
| 287 | 287 | (a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face | Anx-A_287 | ||
| 288 | 288 | (ii) Using 25mm thick plank | Anx-A_288 | 37 | Sqm |
| 289 | 289 | Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. | Anx-A_289 | ||
| 290 | 290 | (a) For depth not exceeding 1.0M. | Anx-A_290 | ||
| 291 | 291 | (ii) Using 25mm thick plank | Anx-A_291 | 20.47 | Sqm |
| 292 | 292 | Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. | Anx-A_292 | ||
| 293 | 293 | (I) In Sub-structure upto plinth level including dewatering if necessary | Anx-A_293 | ||
| 294 | 294 | (b) In proportion 1:4. | Anx-A_294 | 8.63 | Cum |
| 295 | 295 | 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) | Anx-A_295 | ||
| 296 | 296 | (A) 112mm thick brick wall | Anx-A_296 | ||
| 297 | 297 | (a) In cement mortar in proportion 1:4. \n(1 cement:4 sand) | Anx-A_297 | 28.91 | Sqm |
| 298 | 298 | 15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. | Anx-A_298 | ||
| 299 | 299 | A) On rough side | Anx-A_299 | ||
| 300 | 300 | b) In cement mortar 1:4 | Anx-A_300 | 64.74 | Sqm |
| 301 | 301 | A) On fair side | Anx-A_301 | ||
| 302 | 302 | b) In cement mortar 1:4 | Anx-A_302 | 64.44 | Sqm |
| 303 | 303 | Plain cement concrete floor base in prop1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. complete. | Anx-A_303 | ||
| 304 | 304 | b) 50mm thick | Anx-A_304 | ||
| 305 | 305 | Toilet & Verandah | Anx-A_305 | 64.39 | Sqm |
| 306 | 306 | Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) | Anx-A_306 | ||
| 307 | 307 | a) Normal range \nSomany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make | Anx-A_307 | ||
| 308 | 308 | ii) Of size 600mmx600mm and above | Anx-A_308 | 53.3 | Sqm |
| 309 | 309 | Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) | Anx-A_309 | ||
| 310 | 310 | a) Normal range \nSomany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make | Anx-A_310 | ||
| 311 | 311 | ii) Of size 600mmx600mm and above | Anx-A_311 | 53.3 | Sqm |
| 312 | 312 | Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls). | Anx-A_312 | ||
| 313 | 313 | a) Normal range \nSomany/ Orient/Nitco/Asian Make | Anx-A_313 | ||
| 314 | 314 | ii) Of size 200mmx300mm and above | Anx-A_314 | ||
| 315 | 315 | Toilet walls | Anx-A_315 | 34.33 | Sqm |
| 316 | 316 | Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed. | Anx-A_316 | ||
| 317 | 317 | VITRIFIED | Anx-A_317 | ||
| 318 | 318 | i)Normal range (Sizes 300 mm x 300mm and above) | Anx-A_318 | ||
| 319 | 319 | Somany made- Durastone (Unpolished heavy duty Vitrified Tiles) | Anx-A_319 | ||
| 320 | 320 | a) Premium | Anx-A_320 | 12.51 | Sqm |
| 321 | 321 | Toilet floor | Anx-A_321 | ||
| 322 | 322 | Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified. | Anx-A_322 | ||
| 323 | 323 | (b) With 1st class timber (Bonsum/ Sundi) | Anx-A_323 | 0.31 | Cum |
| 324 | 324 | Providing, fitting and fixing full panelled doors/ windows including oxidised M.S butt hinges (100mm x75 mm x3.55mm) with necessary screws (other fittings to be measured and paid separately ) | Anx-A_324 | ||
| 325 | 325 | B) With 1st class local wood \n(Gamari/Hollock/Bonsum ) | Anx-A_325 | ||
| 326 | 326 | (ii) 35 mm thick. | Anx-A_326 | 1.58 | Sqm |
| 327 | 327 | Providing, fitting and fixing fully glazed window with sash bars including oxidised M.S butt hinges (75mmx 60mmx3.15mm) 2nos.on each leaf and 3 nos. on single leaf (glass panes to be measured and paid separately) | Anx-A_327 | ||
| 328 | 328 | B) With Holock/Gamari/Bonsum wood. | Anx-A_328 | ||
| 329 | 329 | (ii) 35mm thick | Anx-A_329 | 2.54 | Sqm |
| 330 | 330 | Providing, fitting and fixing 24mm/ 29mm thick polymer reinforced moulded PVC door shutters fixed to the chowkath with necessary hinges, screws, bolts etc. as specified and directed at all levels (Door fixtures and fittings to be measured and paid seperately) | Anx-A_330 | ||
| 331 | 331 | b) 29mm thick | Anx-A_331 | 6.9 | Sqm |
| 332 | 332 | Providing and fixing clear sheet glass beded in putty and fixed with/without wooden bidding including necessary cutting and glass to be required sized(payment for wooden bead shall be made separately) | Anx-A_332 | ||
| 333 | 333 | (1) Area of glass panes not exceeding 0.15m2 | Anx-A_333 | ||
| 334 | 334 | (b) 4.00mm thick. | Anx-A_334 | 2.04 | Sqm |
| 335 | 335 | Providing fitting, hoisting and fixing of roof trusses including purlins fabricated using MS circular hollow section conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed. | Anx-A_335 | ||
| 336 | 336 | b) Using other ISI marked approved circular hollow section | Anx-A_336 | ||
| 337 | 337 | 48.3 mm OD Tube | Anx-A_337 | ||
| 338 | 338 | Ver. Rafter | Anx-A_338 | ||
| 339 | 339 | Ver. Purline | Anx-A_339 | 4.13 | Qtl |
| 340 | 340 | Providing corrugated galvenised Iron sheet roofing of TATA SHAKTEE / SAIL including fitting and fixing necessary galvenised J or L hooks, bolts and nuts 8 mm dia with bitumen washer 25 mm dia x 3 mm thick and 1.6 mm thick limpet washer complete excluding cost of roof truss, purlin etc. (Roof trusses and purlin etc.to be measured and paid separately). | Anx-A_340 | ||
| 341 | 341 | (d) 0.60 mm thick | Anx-A_341 | 89.7 | Sqm |
| 342 | 342 | Providing and fixing in position concealed G.I. sections for paneling using High Pressure Steam Cured), pre-primered, self-embossed, designer cement board or the non-primered, plain Fibre cement boards of 6mm thickness confirming IS 14862-2000 fixed on the supporting \"W' profile (0.55mm thick) having a knurled web of 51.5mm and two flanges of 26mm each with lips of 10.55mm ) placed @600mm c/c vertically and 11200mm c/c horizontally in perimetre channel (having one flange of 20mm and another flange of 30mm with thickness of 0.55mm and web of length 27mm).Perimetre channel is fixed on the floor and the ceiling with the nylon sleeves @ 300mm c/c with expandable fasteners. Board is fixed to the \"W\" profile with 25mm long self embedding type Fibre cement Screws @ 300mm c/c, all complete as per the drawing & directions of Engineer-in -charge. The boards may be finished so as to have a uniform gap/groove or Flush finish.The flush finish should be done with Elasto prefab joint sealant. Internal Jointing Compound and paper tape as per the procedure laid down by company. | Anx-A_342 | ||
| 343 | 343 | Note: Alternatively, the uniform gap/groove may be covered with decorative molding or may be finished with Jointing filler including 2 coats of acrylic emulsion paint of approved shade/make, over a coat of cement primer before installing it on the grid as required. | Anx-A_343 | ||
| 344 | 344 | I) Everest Plain FC board or equivalent | Anx-A_344 | ||
| 345 | 345 | Toilet & Ceiling | Anx-A_345 | 60.9 | Sqm |
| 346 | 346 | Providing two coats of acrylic water based wall putty/ wall filler of Asian Paints/ Berger/ Dulux over concrete/ cement plaster/ brick walls and ceilings both internal and external after removing all the loosely adhering material from the wall/ ceiling surface with the help of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department. | Anx-A_346 | 94.84 | Sqm |
| 347 | 347 | Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. | Anx-A_347 | ||
| 348 | 348 | (a) Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) | Anx-A_348 | 30.56 | Sqm |
| 349 | 349 | a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth. | Anx-A_349 | 64.43 | Sqm |
| 350 | 350 | b) Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on new wall surface (two coats) to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials. | Anx-A_350 | 64.43 | Sqm |
| 351 | 351 | Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary forest royelty, sales tax, land compensation, municipal gate fees, if any monopoly duty etc. (profile measurement to be taken and 12.5% deduction for shrinkage to be made from total quantity) etc. complete as directed and specified. | Anx-A_351 | ||
| 352 | 352 | (b) Other than Guwahati city | Anx-A_352 | 214 | Cum |
| 353 | 353 | SANITARY | Anx-A_353 | ||
| 354 | 354 | Supplying and placing ferrocement septic tanks of rectangular shape in to pit with manhole cover with cleaning arrangement over single brick flat soling and 75mm 1:3:6 P.C.C. Baffle wall, inlet and outlet etc are provided at suitable points complete as directed. | Anx-A_354 | ||
| 355 | 355 | (v) 30 Users | Anx-A_355 | 1 | No |
| 356 | 356 | FOR RENOVATION OF EXISTING AUDITORIUM | Anx-A_356 | ||
| 357 | 357 | Dismantling all types of corrugated/ trapezoidal sheet roofing including ridges, hips, valleys and gutters etc. and stacking the materials as directed by the department for all levels | Anx-A_357 | 489.85 | Sqm |
| 358 | 358 | Plain cement concrete floor base in prop1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. complete. | Anx-A_358 | ||
| 359 | 359 | b) 50mm thick | Anx-A_359 | 165.1 | Sqm |
| 360 | 360 | Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). | Anx-A_360 | ||
| 361 | 361 | (b) In prop 1cement: 4 sand :8 coarse aggregate by volume | Anx-A_361 | 74.69 | Cum |
| 362 | 362 | Cement concrete works in topping 1:1:2 (1cement :1sand :2 graded aggregates on R.C.C floor, tread and rise of steps finished with a floating coat of neat cement using cement slurry for bond @ 2.75 kg.of cement per sq. m. of floor to be laid in panels including curing complete as directed. | Anx-A_362 | ||
| 363 | 363 | (b) 20 mm thick | Anx-A_363 | 324.75 | Sqm |
| 364 | 364 | Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) | Anx-A_364 | ||
| 365 | 365 | a) Normal range \nSomany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make | Anx-A_365 | ||
| 366 | 366 | ii) Of size 600mmx600mm and above | Anx-A_366 | 78.13 | Sqm |
| 367 | 367 | 65 mm thick cement concrete floor consisting of 50 mm under layer of cement concrete in prop. 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of 25mm and down) and 15 mm thick wearing layer in cement concrete in prop. 1:1:2 (1cement :1 coarse sand : 2 coarse aggregate of size 10mm down) laid in panels and finished with a floating coat of neat cement finish (using cement slurry for bond @ 2.75 kg. per square metre of floor area) including curing etc. complete as directed. | Anx-A_367 | ||
| 368 | 368 | Stage | Anx-A_368 | 86.97 | Sqm |
| 369 | 369 | Providing and fixing Mineral Fiber Acoustic Ceiling Tiles in 600mm x 600mm of 13mm/15mm thickness to be placed in E- Grid Suspended Ceiling Grid 2430 System consisting of Main Runner 3600 mm long, Cross Tee 1200mm/600mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300 mm c/c. Main Runner shall be placed along the shorter dimension of the area to be covered. The distance between the two Main Runners to be maintained at 1200mm. The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm x 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600mm x 600mm.E-Grid of module size 600mm x 600mm shall be supported by 4/6 mm dia G.I. wire from purlins/soffit Mineral Fiber Acoustic Ceiling Tiles of Everest Industries Limited should be placed in the E-Grid module to form a False Ceiling including the cuttings complete as directed. | Anx-A_369 | ||
| 370 | 370 | A) Everest Designer Ceilings or equivalent as directed by the departement (Primered) | Anx-A_370 | ||
| 371 | 371 | A) Using 13mm thick ceiling tiles | Anx-A_371 | ||
| 372 | 372 | Hall Ceiling | Anx-A_372 | 324.75 | Sqm |
| 373 | 373 | Supplying, fitting and fixing SoundSmooth MB Primer (NSS Primer) with glass wool of Anutone Acoustics Ltd. Including all fixtures and fittings. | Anx-A_373 | ||
| 374 | 374 | a) 20 MM | Anx-A_374 | 194.54 | Sqm |
| 375 | 375 | m) Distempering two coats with oil bound distemper of approved brand and manufacture and of required shade on new wall surface to give an even shade, over and including a priming coat with distemper primer of approved brand and manufacture after throughly brooming the surface free from mortar dropings and other foreign matter and including preparing surface even and sand papered smooth. | Anx-A_375 | ||
| 376 | 376 | (i) Priming coat with distemper primer | Anx-A_376 | 90.93 | Sqm |
| 377 | 377 | (ii) Top coat | Anx-A_377 | 90.93 | Sqm |
| 378 | 378 | Supply of Auditorium Chair | Anx-A_378 | 164 | Nos |
| 379 | 379 | Add Cost for Sound System (L/S Rs.50000.00) | Anx-A_379 | 1 | LS |
| 380 | 380 | BRICK BOUNDARY WALL | Anx-A_380 | ||
| 381 | 381 | EARTH WORK | Anx-A_381 | ||
| 382 | 382 | Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. | Anx-A_382 | ||
| 383 | 383 | (A) Up to a depth of 2.00m below the existing ground level. | Anx-A_383 | ||
| 384 | 384 | (a) In ordinary soil | Anx-A_384 | ||
| 385 | 385 | Wall Post | Anx-A_385 | 186.62 | Cum |
| 386 | 386 | Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. | Anx-A_386 | ||
| 387 | 387 | (a) Brick on flat soling. | Anx-A_387 | 284.85 | Sqm |
| 388 | 388 | Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). | Anx-A_388 | ||
| 389 | 389 | (a) In prop 1cement: 3 sand :6 coarse aggregate by volume | Anx-A_389 | 20.98 | Sqm |
| 390 | 390 | Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) | Anx-A_390 | ||
| 391 | 391 | (I) Using Mixer Machine | Anx-A_391 | ||
| 392 | 392 | (A) In substructure up to plinth level | Anx-A_392 | ||
| 393 | 393 | Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. | Anx-A_393 | ||
| 394 | 394 | N) Without using admixture, plasticiser | Anx-A_394 | ||
| 395 | 395 | a) M15 grade concrete or Prop. 1:2:4 | Anx-A_395 | 71.47 | Cum |
| 396 | 396 | (B) In super structure from plinth level up to 1st floor level. | Anx-A_396 | ||
| 397 | 397 | ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. | Anx-A_397 | ||
| 398 | 398 | N) Without using admixture, plasticiser | Anx-A_398 | ||
| 399 | 399 | a) M15 grade concrete or Prop. 1:2:4 | Anx-A_399 | 20.31 | Cum |
| 400 | 400 | Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. | Anx-A_400 | ||
| 401 | 401 | (I) In Sub-structure upto plinth level including dewatering if necessary | Anx-A_401 | ||
| 402 | 402 | (b) In proportion 1:4. | Anx-A_402 | 10.87 | Cum |
| 403 | 403 | 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) | Anx-A_403 | ||
| 404 | 404 | (A) 112mm thick brick wall | Anx-A_404 | ||
| 405 | 405 | (a) In cement mortar in proportion 1:4. \n(1 cement:4 sand) | Anx-A_405 | 463.64 | Sqm |
| 406 | 406 | 15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. | Anx-A_406 | ||
| 407 | 407 | A) On rough side | Anx-A_407 | ||
| 408 | 408 | b) In cement mortar 1:4 | Anx-A_408 | 1180.71 | Sqm |
| 409 | 409 | a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth. | Anx-A_409 | ||
| 410 | 410 | Area same of Plastered area | Anx-A_410 | 1180.71 | Sqm |
| 411 | 411 | b) Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on new wall surface (two coats) to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials. | Anx-A_411 | 1180.71 | Sqm |
| 412 | 412 | Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.\n(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) | Anx-A_412 | ||
| 413 | 413 | c) ISI approved Mild steel reinforcement bar(M.S.Bar) | Anx-A_413 | 62.75 | Qtl |
| 414 | 414 | Supplying, fitting and fixing double leaf heavy duty iron gate, frame made from 50mm x 6mm M.S. flat iron with another horizontal flat at the middle, 20mm dia M.S bars at 200mm apart from bottom flat to top flat and 20 mm dia M.S. bars at 200mm apart from bottom flat to middle flat including drilling, welding etc. complete. All vertical bars are to be protruded at least 100mm above the middle and top flat is to be flattended and pointed as directed. Necessary locking arrangement on both faces, arrangement for temporary closing the gate and 2 nos.( minium) strong iron hinges of M.S bars and flat of same sizes on each leaf to be embeded in C.C brick pillars as necessary including a red oxide painting to all iron works as directed and specified. (Separate payment will be made for posts). | Anx-A_414 | 4.68 | Qtl |
| 415 | 415 | EARTH WORK | Anx-A_415 | ||
| 416 | 416 | Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. | Anx-A_416 | ||
| 417 | 417 | (A) Up to a depth of 2.00m below the existing ground level. | Anx-A_417 | ||
| 418 | 418 | (a) In ordinary soil | Anx-A_418 | 9.98 | Cum |
| 419 | 419 | Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. | Anx-A_419 | ||
| 420 | 420 | (c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading. | Anx-A_420 | 9.95 | Cum |
| 421 | 421 | Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. | Anx-A_421 | ||
| 422 | 422 | (a) Brick on flat soling. | Anx-A_422 | 23.17 | Sqm |
| 423 | 423 | Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). | Anx-A_423 | ||
| 424 | 424 | (a) In prop 1cement: 3 sand :6 coarse aggregate by volume | Anx-A_424 | 0.7 | Cum |
| 425 | 425 | Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) | Anx-A_425 | ||
| 426 | 426 | (I) Using Mixer Machine | Anx-A_426 | ||
| 427 | 427 | (A) In substructure up to plinth level | Anx-A_427 | ||
| 428 | 428 | Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. | Anx-A_428 | ||
| 429 | 429 | N) Without using admixture, plasticiser | Anx-A_429 | ||
| 430 | 430 | a) M15 grade concrete or Prop. 1:2:4 | Anx-A_430 | 1.17 | Cum |
| 431 | 431 | (B) In super structure from plinth level up to 1st floor level. | Anx-A_431 | ||
| 432 | 432 | ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. | Anx-A_432 | ||
| 433 | 433 | N) Without using admixture, plasticiser | Anx-A_433 | ||
| 434 | 434 | a) M15 grade concrete or Prop. 1:2:4 | Anx-A_434 | 1.48 | Cum |
| 435 | 435 | Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. | Anx-A_435 | ||
| 436 | 436 | (I) In Sub-structure upto plinth level including dewatering if necessary | Anx-A_436 | ||
| 437 | 437 | (b) In proportion 1:4. | Anx-A_437 | 8.15 | Cum |
| 438 | 438 | 65 mm thick cement concrete floor consisting of 50 mm under layer of cement concrete in prop. 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of 25mm and down) and 15 mm thick wearing layer in cement concrete in prop. 1:1:2 (1cement :1 coarse sand : 2 coarse aggregate of size 10mm down) laid in panels and finished with a floating coat of neat cement finish (using cement slurry for bond @ 2.75 kg. per square metre of floor area) including curing etc. complete as directed. | Anx-A_438 | ||
| 439 | 439 | Ramp | Anx-A_439 | 23.75 | Sqm |
| 440 | 440 | Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor. | Anx-A_440 | ||
| 441 | 441 | (a) 15 mm thick | Anx-A_441 | 54.38 | Sqm |
| 442 | 442 | 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) | Anx-A_442 | ||
| 443 | 443 | (A) 112mm thick brick wall | Anx-A_443 | ||
| 444 | 444 | (a) In cement mortar in proportion 1:4. \n(1 cement:4 sand) | Anx-A_444 | 51.6 | Sqm |
| 445 | 445 | 15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. | Anx-A_445 | ||
| 446 | 446 | A) On rough side | Anx-A_446 | ||
| 447 | 447 | b) In cement mortar 1:4 | Anx-A_447 | 129.72 | Sqm |
| 448 | 448 | Providing corrugated galvenised Iron sheet roofing of TATA SHAKTEE / SAIL including fitting and fixing necessary galvenised J or L hooks, bolts and nuts 8 mm dia with bitumen washer 25 mm dia x 3 mm thick and 1.6 mm thick limpet washer complete excluding cost of roof truss, purlin etc. (Roof trusses and purlin etc.to be measured and paid separately). | Anx-A_448 | ||
| 449 | 449 | (d) 0.60 mm thick | Anx-A_449 | 31.35 | Sqm |
| 450 | 450 | Providing galvd iron ridging of TATA SHAKTEE / SAIL including supplying and fixing necessary galvd screws/washers etc. complete as directed. | Anx-A_450 | ||
| 451 | 451 | (d) 0.60 mm thick | Anx-A_451 | ||
| 452 | 452 | (ii) 230 mm lapping | Anx-A_452 | 7.36 | Sqm |
| 453 | 453 | Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified. | Anx-A_453 | ||
| 454 | 454 | (b) With 1st class timber (Bonsum/ Sundi) | Anx-A_454 | 0.46 | Cum |
| 455 | 455 | Providing undressed wood work in roof truss, rafter, purlin, tie and the like including hoisting and fixing in position with necessary spikes, nails including M.S straps with bolt and nuts etc.complete with kiricide oiling two coats to all timber members and two coats of anticorrosive paint to M.S straps (M.S flats, angle cleats, and bolt and nuts required for flat and angle cleats wherever used shall be measured and paid separately) | Anx-A_455 | ||
| 456 | 456 | (b) With Hollock/ Sundi/ Sam | Anx-A_456 | 0.37 | Cum |
| 457 | 457 | Providing, fitting and fixing fully glazed window with sash bars including oxidised M.S butt hinges (75mmx 60mmx3.15mm) 2nos.on each leaf and 3 nos. on single leaf (glass panes to be measured and paid separately) | Anx-A_457 | ||
| 458 | 458 | B) With Holock/Gamari/Bonsum wood. | Anx-A_458 | ||
| 459 | 459 | (ii) 35mm thick | Anx-A_459 | ||
| 460 | 460 | Windows | Anx-A_460 | 2.42 | Sqm |
| 461 | 461 | Providing, fitting and fixing full panelled doors/ windows including oxidised M.S butt hinges (100mm x75 mm x3.55mm) with necessary screws (other fittings to be measured and paid separately ) | Anx-A_461 | ||
| 462 | 462 | B) With 1st class local wood \n(Gamari/Hollock/Bonsum ) | Anx-A_462 | ||
| 463 | 463 | (ii) 35 mm thick. | Anx-A_463 | 5.93 | Sqm |
| 464 | 464 | Providing, fitting and fixing fully glazed clerestory window and fan light including fitting and fixing 2 M.S pivot hinges (75mm x 20mm x 3mm), eye hook and nylon chord complete (glass panes shall be measured and paid separately) | Anx-A_464 | ||
| 465 | 465 | B) With Holock/Gamari/Bonsum wood. | Anx-A_465 | ||
| 466 | 466 | (ii) 35mm thick | Anx-A_466 | 1.27 | Sqm |
| 467 | 467 | a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth. | Anx-A_467 | ||
| 468 | 468 | Area same of Plastered area | Anx-A_468 | 129.72 | Sqm |
| 469 | 469 | b) Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on new wall surface (two coats) to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials. | Anx-A_469 | ||
| 470 | 470 | Area same of Plastered area | Anx-A_470 | 129.72 | Sqm |
| 471 | 471 | Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.\n(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) | Anx-A_471 | ||
| 472 | 472 | a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL | Anx-A_472 | ||
| 473 | 473 | (ii)Super Ductile (SD) TMT reinforcement bars | Anx-A_473 | 3.81 | Qtl |
| 474 | 474 | Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting. | Anx-A_474 | ||
| 475 | 475 | (a) With ready mixed paint , Wood primer (pink) | Anx-A_475 | 25.85 | Sqm |
| 476 | 476 | Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping. | Anx-A_476 | ||
| 477 | 477 | (i) Surfaces over 100mm in width or girth. | Anx-A_477 | ||
| 478 | 478 | a) General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac). | Anx-A_478 | 206.66 | Sqm |
| 479 | 479 | Providing fitting and fixing vitreous water closet squatting pan (Indian type W.C Orissa pattern) with all fittings and fixtures complete including cutting and making good to the walls and floors whereever required. (Flushing Cistern to be paid separately) | Anx-A_479 | ||
| 480 | 480 | Indian type W.C Orissa pattern of size 580 x 440 mm | Anx-A_480 | ||
| 481 | 481 | a) White | Anx-A_481 | ||
| 482 | 482 | i) Parryware make | Anx-A_482 | 2 | No |
| 483 | 483 | Supplying, fiting and fixing PVC flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately) | Anx-A_483 | ||
| 484 | 484 | i) Parryware make | Anx-A_484 | ||
| 485 | 485 | (ii) Deluxe Single Flush (Cat. No. C8091/C8057) | Anx-A_485 | 2 | No |
| 486 | 486 | Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. | Anx-A_486 | ||
| 487 | 487 | a) In exposed surfaces or in trenches. | Anx-A_487 | ||
| 488 | 488 | (ii) 110mm dia. | Anx-A_488 | 36 | Rm |
| 489 | 489 | (iv) 75mm dia. | Anx-A_489 | 24 | Rm |
| 490 | 490 | Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. | Anx-A_490 | ||
| 491 | 491 | a) In exposed surfaces or in trenches. | Anx-A_491 | ||
| 492 | 492 | (ii) 110mm dia. | Anx-A_492 | 8 | Nos |
| 493 | 493 | Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. | Anx-A_493 | ||
| 494 | 494 | a) In exposed surfaces or in trenches. | Anx-A_494 | ||
| 495 | 495 | (ii) 110mm dia. | Anx-A_495 | 4 | Nos |
| 496 | 496 | Providing fitting and fixing PVC cowel of ISI make complete as directed and specified. | Anx-A_496 | ||
| 497 | 497 | (ii) 110mm dia. PVC cowel of ISI make | Anx-A_497 | 2 | Nos |
| 498 | 498 | CONSTRUCTION OF SEPTIC TANK (50 USER) | Anx-A_498 | ||
| 499 | 499 | Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. | Anx-A_499 | ||
| 500 | 500 | (A) Up to a depth of 2.00m below the existing ground level. | Anx-A_500 | ||
| 501 | 501 | (a) In ordinary soil | Anx-A_501 | 11.86 | Cum |
| 502 | 502 | Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. | Anx-A_502 | ||
| 503 | 503 | (a) Brick on flat soling. | Anx-A_503 | 6.98 | Sqm |
| 504 | 504 | Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). | Anx-A_504 | ||
| 505 | 505 | (a) In prop 1cement: 3 sand :6 coarse aggregate by volume | Anx-A_505 | 1.4 | Cum |
| 506 | 506 | Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.\n(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) | Anx-A_506 | ||
| 507 | 507 | a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL | Anx-A_507 | ||
| 508 | 508 | b) Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX)\n (For Assam Type Bldg., drain works,,retaining wall&boundary wall etc. . | Anx-A_508 | 1.01 | Qtl |
| 509 | 509 | Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: | Anx-A_509 | ||
| 510 | 510 | Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. | Anx-A_510 | ||
| 511 | 511 | (b) Using 25mm thick plank | Anx-A_511 | 5.11 | Sqm |
| 512 | 512 | Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) | Anx-A_512 | ||
| 513 | 513 | (I) Using Mixer Machine | Anx-A_513 | ||
| 514 | 514 | (A) In substructure up to plinth level | Anx-A_514 | ||
| 515 | 515 | Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. | Anx-A_515 | ||
| 516 | 516 | N) Without using admixture, plasticiser | Anx-A_516 | ||
| 517 | 517 | a) M15 grade concrete or Prop. 1:2:4 | Anx-A_517 | 0.68 | Cum |
| 518 | 518 | 230mm thick brick wall in cement morter with 1st class brick including racking out joints and curing complete as directed in structure | Anx-A_518 | ||
| 519 | 519 | (I) In Sub-structure upto plinth level including dewatering if necessary | Anx-A_519 | ||
| 520 | 520 | (b) In proportion 1:4. | Anx-A_520 | 17.81 | Sqm |
| 521 | 521 | 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) | Anx-A_521 | ||
| 522 | 522 | (A) 112mm thick brick wall | Anx-A_522 | ||
| 523 | 523 | (a) In cement mortar in proportion 1:4. \n(1 cement:4 sand) | Anx-A_523 | 2.3 | Sqm |
| 524 | 524 | Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor. | Anx-A_524 | ||
| 525 | 525 | (b) 20 mm thick | Anx-A_525 | 38.39 | Sqm |
| 526 | 526 | 15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. | Anx-A_526 | ||
| 527 | 527 | A) On rough side | Anx-A_527 | ||
| 528 | 528 | b) In cement mortar 1:4 | Anx-A_528 | 6.12 | Sqm |
| 529 | 529 | Providing fitting and fixing 450mm dia. 90mm thick C.I. Man hole cover and frame of 58 Kg. weight complete as directed and specified. | Anx-A_529 | 2 | Nos |
| 530 | 530 | Construction of inspection pit inside measurement 450mm x450mm x450mm flush with 100mm diameter HCI/PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling, 12cm brick wall in cement mortar in proportion 1:4 finished with 13mm cement plaster in proportion 1:2 in side wall and floor. 450mm x450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pit as directed. | Anx-A_530 | 5.09 | Cum |
| 531 | 531 | Construction of inspection pit inside measurement 450mm x450mm x450mm flush with 100mm diameter HCI/PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling, 12cm brick wall in cement mortar in proportion 1:4 finished with 13mm cement plaster in proportion 1:2 in side wall and floor. 450mm x450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pit as directed. | Anx-A_531 | 4 | Nos |
| 532 | 532 | Water Supply: | Anx-A_532 | ||
| 533 | 533 | CONSTRUCTION OF R.C.C. STAGING & SAND FILTER | Anx-A_533 | ||
| 534 | 534 | Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. | Anx-A_534 | ||
| 535 | 535 | (A) Up to a depth of 2.00m below the existing ground level. | Anx-A_535 | ||
| 536 | 536 | (a) In ordinary soil | Anx-A_536 | 9.68 | Cum |
| 537 | 537 | Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. | Anx-A_537 | ||
| 538 | 538 | (a) Brick on flat soling. | Anx-A_538 | 16.47 | Sqm |
| 539 | 539 | Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). | Anx-A_539 | ||
| 540 | 540 | (a) In prop 1cement: 3 sand :6 coarse aggregate by volume | Anx-A_540 | 0.9 | Cum |
| 541 | 541 | Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: | Anx-A_541 | ||
| 542 | 542 | Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. | Anx-A_542 | ||
| 543 | 543 | (b) Using 25mm thick plank | Anx-A_543 | 3.84 | Sqm |
| 544 | 544 | Sides of tie beams, grade beams etc. at or below ground level. | Anx-A_544 | ||
| 545 | 545 | (b) Using 25mm thick plank | Anx-A_545 | 17.4 | Sqm |
| 546 | 546 | Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. | Anx-A_546 | ||
| 547 | 547 | (a) For depth not exceeding 1.0M. | Anx-A_547 | ||
| 548 | 548 | (ii) Using 25mm thick plank | Anx-A_548 | 10.56 | Sqm |
| 549 | 549 | Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. | Anx-A_549 | ||
| 550 | 550 | (a) Floors etc. upto 200mm in thickness. | Anx-A_550 | ||
| 551 | 551 | (i) Using 38mm thick plank | Anx-A_551 | 11.01 | Sqm |
| 552 | 552 | Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) | Anx-A_552 | ||
| 553 | 553 | (I) Using Mixer Machine | Anx-A_553 | ||
| 554 | 554 | (A) In substructure up to plinth level | Anx-A_554 | ||
| 555 | 555 | Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. | Anx-A_555 | ||
| 556 | 556 | N) Without using admixture, plasticiser | Anx-A_556 | ||
| 557 | 557 | a) M15 grade concrete or Prop. 1:2:4 | Anx-A_557 | 2.9 | Cum |
| 558 | 558 | (B) In super structure from plinth level up to 1st floor level. | Anx-A_558 | ||
| 559 | 559 | ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. | Anx-A_559 | ||
| 560 | 560 | N) Without using admixture, plasticiser | Anx-A_560 | ||
| 561 | 561 | a) M15 grade concrete or Prop. 1:2:4 | Anx-A_561 | 5.46 | Cum |
| 562 | 562 | 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) | Anx-A_562 | ||
| 563 | 563 | (A) 112mm thick brick wall | Anx-A_563 | ||
| 564 | 564 | (a) In cement mortar in proportion 1:4. \n(1 cement:4 sand) | Anx-A_564 | 27.29 | Sqm |
| 565 | 565 | 15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. | Anx-A_565 | ||
| 566 | 566 | A) On rough side | Anx-A_566 | ||
| 567 | 567 | b) In cement mortar 1:4 | Anx-A_567 | 55.36 | Sqm |
| 568 | 568 | A) On fair side | Anx-A_568 | ||
| 569 | 569 | b) In cement mortar 1:4 | Anx-A_569 | 28.16 | Sqm |
| 570 | 570 | Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.\n(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) | Anx-A_570 | ||
| 571 | 571 | a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL | Anx-A_571 | ||
| 572 | 572 | (ii)Super Ductile (SD) TMT reinforcement bars | Anx-A_572 | 5.48 | Qtl |
| 573 | 573 | Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc.complete at all levels including below G.L. as directed and specified. | Anx-A_573 | ||
| 574 | 574 | (A) Exposed on walls | Anx-A_574 | ||
| 575 | 575 | b) 40 mm dia (Medium) | Anx-A_575 | ||
| 576 | 576 | i) Using Tata make | Anx-A_576 | 10 | Rm |
| 577 | 577 | Labour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department. | Anx-A_577 | ||
| 578 | 578 | iii) Bore hole of 125mm diameter | Anx-A_578 | 85 | Rm |
| 579 | 579 | Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. | Anx-A_579 | ||
| 580 | 580 | II) PVC PIPE | Anx-A_580 | ||
| 581 | 581 | SUPREME /PRINCE / FUSION /SFMC Brand | Anx-A_581 | ||
| 582 | 582 | v) 110mm diameter | Anx-A_582 | 63.94 | Rm |
| 583 | 583 | Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed. | Anx-A_583 | ||
| 584 | 584 | B) PVC PIPE | Anx-A_584 | ||
| 585 | 585 | SUPREME / PRINCE / FUSION /SFMC Brand | Anx-A_585 | ||
| 586 | 586 | iii) 40mm diameter | Anx-A_586 | 50 | Rm |
| 587 | 587 | Supplying fitting and fixing ISI approved PVC filter 3.00 metre long. | Anx-A_587 | 3 | Nos |
| 588 | 588 | Development of the tube well with compressor or by over pumping unit for 48 hours till sand free discharge is obtained | Anx-A_588 | 1 | Nos |
| 589 | 589 | Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes | Anx-A_589 | ||
| 590 | 590 | I) 2000 Lt capacity | Anx-A_590 | ||
| 591 | 591 | (a) Sintex make | Anx-A_591 | 2 | Nos |
| 592 | 592 | Labour for erecting and placing PCVC Tank over the stagging up to a height of 5.00m complete as directed. | Anx-A_592 | ||
| 593 | 593 | (a) 2000 litre capacity | Anx-A_593 | 2 | Nos |
| 594 | 594 | Supplying including installation, connection as approved by the Deptt., testing and commissioning of SUBMERSIBLE PUMP SET 3 (Three Phase) with steel cable rope and submersible cable complete as directed and specified by the deptt. | Anx-A_594 | ||
| 595 | 595 | Three phase Submersible motor pump set (Texmo / Crompton Greaves/ Aquatic/ CRI/ V-Guar suitable for 100 mm bore well and above. 3 HP STAGE 7 to 40 with MCB controlled Submersible motor pump set control panel. | Anx-A_595 | 1 | Nos |
| 596 | 596 | Supplying fitting and fixing approved uPVC Pipes of different sizes, with all necessary 'R' brand or similar approved P.V.C. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified. | Anx-A_596 | ||
| 597 | 597 | (A) Exposed or in trenches | Anx-A_597 | ||
| 598 | 598 | SUPREME/ PRINCE/ SFMC BRAND or other equvalent approved brand (High presure pipe Sch-40) | Anx-A_598 | ||
| 599 | 599 | Exposed or in trenches | Anx-A_599 | ||
| 600 | 600 | d) 25 mm dia | Anx-A_600 | 18 | Rm |
| 601 | 601 | Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) | Anx-A_601 | ||
| 602 | 602 | iv) Agmeco brand | Anx-A_602 | ||
| 603 | 603 | (i) Bib Cock without Flange CAT No.CC 00204/CAT No.CN 00204 | Anx-A_603 | 8 | Nos |
| 604 | 604 | Supplying fitting and fixing gun metal check valve including necessary threads to pipes. | Anx-A_604 | ||
| 605 | 605 | b) 40 mm dia (Heavy type) | Anx-A_605 | 1 | Nos |
| 606 | 606 | Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed. | Anx-A_606 | ||
| 607 | 607 | b) 40 mm dia. | Anx-A_607 | 2 | Nos |
| 608 | 608 | Lum-sum cost for Electrification (Rs.141552.00) | Anx-A_608 | 1 | L/S |
AI Tender Summary
Tender Timeline
Jan 21, 2020
11:30 IST
Tender Published
Tender notice published.
CompletedFeb 06, 2020
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedFeb 10, 2020
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender