Housing Urban and Rular Development Government Departments Closing in 0 days TDR #23309904

Construction Of Various Residential Houses In S . D . O . Civil Complex At Kalayat In Kaithal Distt .

Issued by Government Departments · Kalayat, Haryana
Tender Value
3.02 Crore
Estimated cost
Bid Submission
10 Feb 2020
0 days left
EMD
6.05 Lakhs
Bank guarantee accepted
Document Fee
15000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kalayat → Haryana
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of Various Residential Houses In S . D . O . Civil Complex At Kalayat In Kaithal Distt .

BOQ

Name of Work: CONSTRUCTION OF VARIOUS RESIDENTIAL HOUSES IN S.D.O. CIVIL COMPLEX AT KALAYAT IN KAITHAL DISTT.
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Earth work in excavation in foundations, trenches etc. in all kinds of soil, not exceeding 2 meters depth including dressing of bottom and sides of trenches, stacking the excavated soil, clear from the edge of excavation and subsequent filling around masonry in 15 cm layers with compaction, including disposal of all surplus soil as directed within a lead of 30 Mtrs. (HSR 6.6)item11427.63Cum
22Earth Filling under floors with surplus soil excavated from foundation and taken only from outside the building plinth, in 15 cm layers including ramming watering and consolidating lead up to 30 meters. Subject to condition soil Is non plastic. [HSR 6.13(a)].item2767.43Cum
33Cement concrete 1:8:16 with stone aggregate 40 mm Nominal sie in foundation and plinth. (HSR 10.28)item3182.69Cum
44Cement concrete 1:4:8 with stone aggregate 20 mm nominal size in foundation and plinth. (HSR 10.38)item4131.59Cum
55Cement concrete 1:4:8 with stone aggregate 40 mm nominal size in foundation & plinth. (HSR 10.39)item55.26Cum
66Precast cement concrete 1:1½:3 with stone aggregate 20 mm nominal size in Kerbs and the like itmes, finished smooth with 6 mm thick cement plaster 1:3 on exposed surface including form work, placing and fixing in position, complete as per HSR [HSR. 10.77 + 10.95 (a)].item622.44Cum
77Precast Factory Manufactured cement concrete 1:1½:3 with stone aggregate 20 mm nominal size in Tiles and Chanels the like itmes, finished smooth with 6 mm thick cement plaster 1:3 on exposed surface including form work, placing and fixing in position, complete as per HSR. [HSR. 10.78 + 10.95 (a)].item722.44Cum
88Cement concrete 1:1½:3 with stone aggregate 20 mm nominal size for reinforced concrete work in Shelves excluding steel reinforcement, but including centring and shuttering, laid in position, complete in all respect. [HSR. 10.81+10.95 (a)]. First Storeyitem81.3Cum
99Second Storeyitem90.47Cum
1010Third Storeyitem100.39Cum
1111Fourth Storeyitem110.39Cum
1212Cement concrete 1:1½:3 with stone aggregate 20 mm nominal size for reinforced concrete work in slabs with with inclination not exceeding 25 degree with horizontal, excluding steel reinforcement, but including centring and shuttering, laid in position, complete in all respect. [HSR. 10.82 + 10.95 (a)]. First Storeyitem12107.04Cum
1313Second Storeyitem1345.91Cum
1414Third Storeyitem1428.9Cum
1515Fourth Storeyitem1528.9Cum
1616Fifth Storeyitem168.42Cum
1717Cement concrete 1:1½:3 with stone aggregate 20 mm nominal size for reinforced concrete work in pyramid type roofing excluding steel reinforcement but including centering and shuttering, laid in position, complete in all respects. [HSR. 10.84 + 10.95 (a)]. Second Storeyitem171.75Cum
1818Cement concrete 1:1½:3 with stone aggregate 20 mm nominal size for reinforced concrete work for walls exceeding 20 cm thickness (Straight and curved) beams, girders, stairs, columns, (square or rectangular) battens and lintels etc. excluding steel reinforcement but including centring and shuttering, laid in position complete in all respects. [HSR. 10.86 + 10.95 (a)]. First Storeyitem18160.69Cum
1919Second Storeyitem1943.73Cum
2020Third Storeyitem2028.85Cum
2121Fourth Storeyitem2128.85Cum
2222Fifth Storeyitem2215.39Cum
2323Cement Concrete 1:1½:3 with stone aggregate 20 mm nominal size for reinforced concrete work for circular or curved columns excluding steel reinforcement but including centering and shuttering, laid in position, complete in all respects. [HSR. 10.88 + 10.95 (a)]. First Storeyitem230.49Cum
2424Cement concrete 1:1½:3 with stone aggregate 20 mm nominal size for reinforced concrete work in fasicas, parapets and other thin vertical sections, not covered by item no. 10.82, 10.86 to 10.88 not exceeding 10 cm thickness thickness excluding steel reinforcement but including centring and shuttering, laid in position, complete in all respects. [HSR. 10.89 + 10.95 (a)] Second Storeyitem2420.27Cum
2525Third Storeyitem254.41Cum
2626Fourth Storeyitem264.01Cum
2727Fifth Storeyitem273.48Cum
2828Cement concrete 1:1½:3 with stone aggregate 20mm nominal size for reinforced concrete work in footing, strips, foundation, rafts, pedestal and approach slabs of bridges etc. but excluding steel reinforcement and including centring and shuttering, laid in position, complete in all respects. (for work upto 1.5 Mtrs. below ground level). [HSR. 10.90 + 10.95 (a)].item28416.886Cum
2929Providing and laying 80 mm thick ISI marked internlocing paver paver blocks conforming to IS 15658:2006 /IRC:SP:63-2004 of all Shapes and colours in design mix cement M-40 over a bed of 30 mm thick fine sand complete in all respect. (HSR 10.159). (Note:- Reputed make Paver Block Only ISI marked will be used as approved by Engineer-in-charge).item291251.87Sqm
3030First class brick work laid in cement sand mortar 1:6 in foundation plinth. (HSR 11.2)item30687.13Cum
3131First class brick work laid in cement sand mortar 1:4 in foundation plinth. (HSR 11.4).item31273.914Cum
3232First class brick work laid in cement sand mortar 1:6 in 1st storey upto 4 metre above plinth level. (HSR 11.7) First Storeyitem3269.55Cum
3333Second Storeyitem3359.3Cum
3434Third Storeyitem3438.48Cum
3535Fourth Storeyitem3528.77Cum
3636Fifth Storeyitem3618.52Cum
3737First class brick work laid in cement sand mortar 1:4 in 1st storey upto 4 metre above plinth level. (HSR 11.9).item37157.997Cum
383811.43 cm thick brick wall laid in cement sand mortar 1:4 in spuer-structure. [HSR 11.48 (a)]. First Storeyitem38295.73Sqm
3939Second Storeyitem39151.84Sqm
4040Third Storeyitem4099.12Sqm
4141Fourth Storeyitem4199.12Sqm
4242Dressed or moulded three brick cornice laid in cement sand mortar 1:4 including 12 mm thick cement plaster 1:4 or pointing, as required. (HSR 11.76).item4278.95Rmt
4343Masonry work sing flyash-lime based brick (IS: 12894-2002) laid in cement sand mortar 1:6 in super structure. (HSR 11.102) Note:- The Agency to whom the work is allotted will have to produce original bill/voucher for all quantity in token of proof of purchase of material. First Storeyitem4369.55Cum
4444Second Storeyitem4459.3Cum
4545Third Storeyitem4528.77Cum
4646Fourth Storeyitem4628.77Cum
4747Fifth Storeyitem4718.52Cum
4848Providing & fixing factory manufactured jali of reinforced cement concerete consisting of Cement, coarse sand and 10 mm and down guage bajri in the ratio of 1:1:2 with 8 mm dia tor steel.Outer frame of jali will be 50 mm wide and 25 mm thick and inner frame of jali will be 25 mm wide and 25 mm thick with smooth finish as per design approved by Engineer-in Charge including fixing in position up to any height with cement sand mortor 1:4, complete in all respect. (11.103).item4824.49Sqm
4949Terracing consisting of 19 mm thick heat resistant tiles for roof insulation, 300 mm x 300 mm laid on 20 mm thick 1:3 cement coarse sand mortor including grouting with neat white cement over average 75 mm thick screed of 1:8:16 including two coats of bitumen laid hot at 1.65 Kg per sqm on top of RCC slab & cleaning of top surface complete .the tiles shall be made of white cement blended with fibrous polymer having flextural stress value of = 150 Kg/Cm 2 & thermal conductivity value = 0.18 w/m.k. Note:- Including rubbing polishing complete in all respect. (HSR 13.97) Second Storeyitem49426.06Sqm
5050Third Storeyitem50105.19Sqm
5151Fifth Storeyitem51171.8Sqm
5252Sixth Storeyitem5245.71Sqm
5353Top khurra 0.6 m x 0.6 m for rain water pipe in 25 mm thick cement concrete 1:2:4 over 50 mm thick cement concrete 1:8:16. (HSR 13.50)item5319Each
5454Supplying & fixing in position G.I. pipe class 'B' spouts in chajjas and cantilevers. (e) 50mm i/d G.I. pipe. [HSR 13.55 (e)].item5430.19Rmt
5555Bottom khurra on ground 1.2 m x 0.6m consisting of brick on edge laid in cment mortar 1:3 over 75mm c:c 1:8:16 including 12mm thick cement plaster 1:3. (HSR 13.57)item5519Each
5656Cement Concrete 1:2:4 gola 10cm x 10cm quadrant along junction of roof with parapet wall finished smooth, where specified. (HSR 13.64).item56413.74Rmt
5757Providing & Fixing PVC Rainwater Pipe 6 kg. pressure of ISI mark in cement mortar during masonry work. (Note:- Reputed make PVC Pipe such as Supreme, Finolex, Prince will be used as approved by Engineer-in-charge. [HSR 13.89].\nNote:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material. (a) 100 mm dia PVC pipe 6 kg. pressure.item5763.41Rmt
5858(b) 150 mm dia PVC pipe 6 kg. pressure.item5854.57Rmt
5959Providing and fixing PVC Bend ISI Mark. (Note:- Reputed make PVC Bend such as Supreme, Finolex, Prince will be used as approved by Engineer-in-charge. [HSR 13.90]. Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material. (a) 100 mm dia PVC Bend.item5930Each
6060(b) 150 mm dia PVC Bend.item608Each
6161Base course of floors consisting of 100 mm thick cement concrete 1:8:16 and 100 mm sand or stone filling. (HSR 14.1)item611074.58Sqm
6262Screed of 50 mm thick cement concrete 1:8:16 to be laid below the topping. (HSR 14.4) Second Storeyitem62286.11Sqm
6363Third Storeyitem63194.81Sqm
6464Fourth Storeyitem64194.81Sqm
6565Fifth Storeyitem6548.5Sqm
6666Conglomerate floor 40 mm thick Cement Concrete topping 1:2:4. (HSR 14.9)item66204.41Sqm
6767Precast chequered tiles of 20 mm thickness In ordinary grey cement without chips laid on 20 mm thick bed of cement coarse sand mortar 1:3 with neat cement slurry between joints and over the base in floors, treads of steps and landings. (Note:- Reputed make Tile Only ISI marked will be used as approved by Engineer-in-charge). [HSR 14.45+Note].\nNote:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material. First Storeyitem6788.36Sqm
6868Precast Terrazzo tiles of 20 mm minimum thickness in cement as specified below with marble chips of size and colour as required laid on 20 mm thick bed of cement coarse sand mortar 1:3 with neat cement slurry, between joints and over the base in floors, treads of steps and landings including rubbing and polishing. (b) in 50% white & 50% grey cement. (Note:- Reputed make Tile Only ISI marked will be used as approved by Engineer-in-charge). (HSR 14.44 (b)]. Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material. Second Storeyitem6899.97Sqm
6969Third Storeyitem6999.97Sqm
7070Fourth Storeyitem7099.97Sqm
7171Precast terrazzo tile of 12.5 mm minimum thickness in cement as specified below with marble chips of size and colour as required laid on 10 mm thick cement coarse sand plaster 1:3 and jointed with neat cement slurry in skirting, dado and risers of steps, including rubbing and polishing complete. (b) in 50% white and 50% grey cement. (Note:- Reputed make Tile Only ISI marked will be used as approved by Engineer-in-charge). (HSR 14.47 (b)].\nNote:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material. Second Storeyitem7111.49Sqm
7272Third Storeyitem7211.49Sqm
7373Fourth Storeyitem7311.49Sqm
7474Kotah stone flooring minimum 25 mm thick in any pattern as specified over 12 mm thick base of cement coarse sand mortar 1:3 laid and jointed with neat cement slurry mixed with pigment to match the shade of stone including rubbing and polishing. (HSR 14.62). Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material. First Storeyitem74316.61Sqm
7575Second Storeyitem7597Sqm
7676Third Storeyitem7668.06Sqm
7777Fourth Storeyitem7768.06Sqm
7878Fifth Storeyitem7848.5Sqm
7979Extra for nosing in treads of steps of Kotah stone slab. (HSR 14.65)item79255.38Rmt
8080Kotah stone 20 mm thick in skirting risers of steps, dados and wall facing (lining) and pillars laid on 12 mm thick cement coarse sand plaster 1:3 laid and jointed with neat cement slurry, mixed with pigment to match the shade of stone including rubbing and polishing including labour for fixing cramps, dowels and pins etc. (HSR 14.66).\nNote:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material. First Storeyitem8049.88Sqm
8181Second Storeyitem8125.43Sqm
8282Third Storeyitem8218.8Sqm
8383Fourth Storeyitem8318.8Sqm
8484Fifth Storeyitem845.91Sqm
8585Providing and fixing glass strips 5.5 mm thick 40 mm wide in floors. (HSR 14.80].item85239.94Rmt
8686Providing & fixing ceramic tiles/anti skid tiles of size 400mm x 400mm or above size of approved make in flooring, laid in any pattern as specified over base of 20 mm thickcement coarse sandmortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of tiles. Not : Tile shall be of premium quality (first quality) of reputed manufacturer like:- RAK, NITCO, KAJARIA, SOMANI, JOHNSONS, ORIENTBELL, SIMPOLO shall be used as approved by Engineer-in-charge. (HSR 14.91). \nNote:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material. First Storeyitem8668.33Sqm
8787Second Storeyitem8781.06Sqm
8888Third Storeyitem8829.82Sqm
8989Fourth Storeyitem8929.82Sqm
9090Providing & Fixing Ist quality Ceramic glazed wall tiles confirming to I.S. 15622 (thickness to be specified by the manu-facturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-In-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 coarse and jointed with grey cement slurry, including ointing in white cement mixed with pigment of matching shades complete. (b) Size of ceramic Glazed tiles 300 x 450 mm of reputed manufacturer like:- RAK, NITCO, KAJARIA, SOMANI, JOHNSONS, ORIENTBELL, SIMPOLO shall be used as approved by Engineer-in-charge. [HSR 14.92(b)].\nNote:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material. First Storeyitem90205.69Sqm
9191Second Storeyitem91130.13Sqm
9292Third Storeyitem9294.66Sqm
9393Fourth Storeyitem9394.66Sqm
9494Laying and fixing Granite stone in all shade,15mm to 18mm thick in skirting/dados, risers of steps, pillars, wall facing, laid in any pattern as specified over base of 12mm thick cement coarse sand mortor 1:3 and jointed with white cement slurry mixed with pigment yo match the shade of granite including labour for fixing cramps pins and dowels etc. (Excluding the cost of Granite, Granite will be supplied by the Department.) (HSR 14.95). First Storeyitem9427.85Sqm
9595Second Storeyitem957.57Sqm
9696Second Storeyitem967.26Sqm
9797Third Storeyitem977.26Sqm
9898Laying and fixing Granite stone in all shades 15 mm to 18 mm thick in flooring, laid in any pattern as specified over base of 20 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of granite stone. (Excluding the cost of Granite, Granite will be supplied by the Department). (HSR 14.96). First Storeyitem98139.09Sqm
9999Second Storeyitem996.23Sqm
100100Second Storeyitem1005.11Sqm
101101Third Storeyitem1015.11Sqm
102102Providing edge moulding to 17-20 mm thick Granite stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. (ii) Double Moulding (HSR 14.98 (ii)).item10280.56Rmt
10310312mm thick cement Plaster 1:4. (HSR 15.5).item103886.384Sqm
10410412mm thick cement plaster on walls (1:6). (HSR 15.7). First Storeyitem104884.98Sqm
105105Second Storeyitem105667.84Sqm
106106Third Storeyitem106393.38Sqm
107107Fourth Storeyitem107350.89Sqm
108108Fifth Storeyitem108162.04Sqm
10910915mm Thick Cement Plaster 1:4 on the rough side of single or half brick wall. (HSR 15.10).item109777.724Sqm
11011015mm Thick Cement Plaster 1:6 on the rough side of single or half brick wall. (HSR 15.12). First Storeyitem1101071.01Sqm
111111Second Storeyitem111781.92Sqm
112112Third Storeyitem112466.84Sqm
113113Fourth Storeyitem113424.35Sqm
114114Fifth Storeyitem114165.61Sqm
11511510mm thick cement plaster 1:4 under side of ceiling. (HSR 15.52). First Storeyitem115633.9Sqm
116116Second Storeyitem116286.11Sqm
117117Third Storeyitem117194.81Sqm
118118Fourth Storeyitem118194.81Sqm
119119Fifth Storeyitem11948.5Sqm
12012020 mm thick cement plaster vertical damp proof coarse 1:3 with two coats of bitumen at 1.65 Kg. per sqm. Laid hot & sanded. (a) Vertical. (HSR 15.77 (a)].item12088.16Sqm
121121Preparation of ply wood surface for painting inlcuding sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete. Painting on wooden surfaces etc. (HSR 16.1)item1211135.34Sqm
122122Applying pink primer or aluminium priming coat on wood work including preparation of surface, knotting and stopping etc. (Note:- First quality paint/primer of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.2).item1221135.34Sqm
123123Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. (Note:- First quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.3).item1231135.34Sqm
124124Applying priming coat with metal primer on new steel or iron work including preparation of surface. Painting on mettalic Surfaces etc. (Note:- First quality paint/primer of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.9).item124864.81Sqm
125125Painting two coats excluding priming coat with ready mixed paint for matelic sufraces in all shades on new steel or iron work. (Note:- First quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.17).item125864.81Sqm
126126Applying priming coat with cement primer in all shades on newly plastered or concrete exterior surface. (Note:- First quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.25).item126147.28Sqm
127127Painting two coats with ready-mixed exterior paint in all shades on newly plastered or concrete surface of walls. (Note:- First quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.26).item127147.28Sqm
128128Painting two coats with plastic emulsion paint on walls on new work to give an even shade. (Note:- First quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.30).item1281701.22Sqm
129129Distempering with washable oil bound distemper (of approved manufacture) two coats over one priming coat on new work. (Note:- First quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.58).item1292604.08Sqm
130130Providing two coats of exterior acrylic emulsion paint. (Note:- First quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). [HSR 16.79 (b)].item1304003.43Sqm
131131Providing and applying two coats white cement based putty over plastered surface and grindling the surface smooth with sand paper to get an even and smooth finish including cost and carriage of all material, labour charges, scaffolding, sundries etc. complete. (Note:- reputed make Putty such as J.K./ Birla shall be used as approved by Engineer-in-charge). (HSR 16.81).item1318282.44Sqm
132132Chowkats of commercial hard wood such as hillock, champ, chikrassy, and chaplash, etc., (Non-coniferous timber other than teak conforming to I.S. specification no. 1003 kiln seasoned), of doors and windows including iron hold fasts, etc., complete fixed in Position. (HSR 17.12).item1329.14Cum
133133Supplying and fixing glass panes wih teak wood moulding- (c) 4 mm thick (glazing area above 55 sq dm, but upto 84 sq dm of each pane). [HSR 17.42 (c)].item13369.65Cum
134134Providing and fixing commercial type block Board, plain lining, butt jointed, including Wooden plugs (teak) placed at 45 cm to 60 cm centres, complete with necessary nails (frame work shall bepayable extra)- (b) 19 mm thick. [HSR 17.49 (b)].item13474.01Sqm
135135Providing and fixing wooden handrail of required shape and desing, with necessary, screws, including labour for rounding, vertical and horizontal bends and curves complete fixed in position (b) commercial hard wood, such as hollock, champ, chikrassy and chaplash, etc (Non coniferous timber other than teak, conforming to I.S specification no. 1003, kiln seasoned) (HSR 17.69) (b)].item1350.57Cum
136136Providing and fixing helical door spring 150 mm (superior quality), including necessary screws, complete- (b) iron. [HSR 17.79 (b)].item13623Each
137137Supplying and fixing hydraulic door closer I.S.I mark, with necessary screws etc. complete (b) I.S.I designation no. II (size of door 701 mm to 850 mm) [HSR 17.82(b)].item13798Each
138138Factory manufactured panelled door or glazed windows shutters of commercial hard wood such as Hollock, Champ, Chikrassy & Chaplash only. (non coniferous timber other teak, confirming to I.S. pecificationNo. 1003, Kiln seasoned) with 100mm wide vertical styles, 150mm wide lock rail 200 mm wide bottom rail, and 100mm wide other rails, with panels of 15mm thick, tongued and grooved of commercial hard wood and including cost of iron hinges, screw, chock/cleats, stops nails etc. complete fixed in position (excluding the cost of any fittings, other than specified above, but including labour for fixing the same in position). (a) 30 mm thick. [HSR 17.90 (a) - Note 1 under 17.18].item13861.66Sqm
139139Factory manufactured paneled and glazed door shutters of commercial hard wood, such as hollock, champ, chikrassy and chaplash, etc., c(non –coniferous timber other than team, conforming to I.S specification no. 1003 kiln seasoned), with 100 mm wide vertical styles, 150 mm wide lock rail, 200 mm wide bottom rail and 100 mm wide other rails, with panelsof 12 mm thick, commercial veneered both side particle board or plywood of B.W.R. grade, hot pressed, including cost of iron hinges, screws, chock/cleats stops and nails etc. complete fixed in position(excluding the cost of any fittings, other than specified above but including labour for fixing the same position. [HSR 17.91 (b) (-) 17.18 - Note]. (b) 35 mm Thick.item13929.28Sqm
140140Factory manufactured wire gauze door and window shutters of commercial hard wood such as Hollock, Champ, Chikrassy & Chaplash only. (non-coniferous timber other teak conforming to I.S. specification No. 1003, kiln seasoned) with 100 mm wide vertical styles, 150 mm wide lock rail 200 mm wide bottom rail, and wire gauze of 140 G or 120 G designation including cost of iron hinges, screws, chock/cleats, stops nails etc., complete fixed in position (excluding the cost of any fittings, other than specified above, but including labour for fixing the same in position. (Styles and rails of windows shutter shall be 75 mm wide. (i) 30 mm thick. [HSR 17.92 (i) - Note 1 under 17.18]item140128.59Sqm
141141Factory manufactured Solid Flush Door Shutter, with block board core as per I.S. No. 1659-1969 bonded with water proof type phenol formaldehyde synthetic resin, hotpressed, conforming to I.S. 2202 part I and II, fixed in position, including iron hinges, screws, chocks/cleats and stops etc., (excluding the cost of any fittings other than specified above, but including labour for fixing the same in position. (Note:- reputed make such as Duro, Green, Kitply will be used as approved by Engineer-in-charge). HSR 17.93 (a) - Note 1 under 17.18]. Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material. (i) 25 mm thick.item14188.17Sqm
142142(iii) 35 mm thick.item142168.49Sqm
143143Wrought iron and mild steel (using angles, flats square bars, tees and channels) ladders, grills, gratting frames, window guards, iron doors openable or fixed stair case or parapet or any other type of railing, gates and tree guards etc., including cost of screws and welding rods or bolts and nuts complete fixed in position. (HSR 18.12).item143233Qtls.
144144Steel reinforcement TMT bars FE-500 EQR/FE-500 D grade or more for R.C.C. works, where no included in the complete rate of R.C.C. including Straightening, bending, binding, wastage, oberlaps, welded joijts, space bars, chairs, stays, hangers and annealed steel wire etc. and placing in position complete in all respects for all heights/depths/storeys/basements etc. Note:- Reinforcement shall be measured in length including hooks, if any separately for different diameters as actually used in work, excluding overlaps. From the length so measured, the weight of reinforcement shall be calculated in tones on the basis of IS-1732. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods for binding and placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. (HSR 18.22)item1441063.33Qtls.
145145Supplying openable steel doors and windows, of standard steel sections, joints mitres and electrically flash welded including provision for arrangement of receiving handles, peg stay, catcher will also be welded with the frame and providing and fixing pressed steel projected hinges, iron lugs, glazing clips (excluding wooden shuters, glazing and fittings such as handles, peg stay and catcher etc.) and finished with one coat of ready mixed red lead non setting primer. (HSR 18.24).item145302.86Kg
146146Supplying and fixing Glass panes including special metal sash putty of approved make. (b) glass panes 4 mm thic, exceeding 40 sq. dm areas. [HSR 18.30 (b)].item146104.09Sqm
147147Pressed steel sheet frames (chowkhats) consisting of 2mm thick steel sheet of the specified section, including iron lugs (hold fasts) iron hinges, conforming to P.W.D. specifications, including bolts for fixing stops, locknotch, provision for receiving tower bolts, and finished with one coat of ready mixed paint red lead non-setting primer, of approved quality, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame, and cement concrete 1:3:6 for lugs complete. [HSR 18.34]. (a) door and window frame Size of 89 mm x 59 mm with 40 mm wide signel rebate.item147300.15Rmt
148148(c) door and window frame size 127 mm X 50 mm with 40 mm wide double rebate.item148673.17Rmt
149149Preparation of sub grade including trenching rough dressing of soil, final dressing of earth, to given levels and camber, watering, rolling with road roller and compacting the bed (HSR 24.1)item1491109.68Sqm
150150NS ITEMS:- Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fastners etc). (NS)item15093.56Kg
151151DSR ITEMS:- Providing & Fixing Vitrified Tiles 600 x 600 mm of approved make in flooring laid in any pattern as specified over base of 20 mm thick cement coarse sand morter 1.3 and jointed with white cement slurry mixed with pigment to match the shade to tiles. Note:- Tile shall be of premium quality (first quality) of reputed manufacturer like: RAK, NITCO, KAJARIA, SOMANI, JOHNSONS, ORIENTBELL, SIMPOLO. (Double charged tiles shall be used as approved by Engineer in charge. (NS). \nNote:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material. First Storeyitem151173.83Sqm
152152Second Storeyitem15215.56Sqm
153153Providing & fixing vitrified tiles of size 600mm x 600mm of approved make in skirting/dados laid in any pattern as specified over base of 12mm thick cement coarse sand mortor 1:3 and jointed with white cement slurry mixed with pigment to match the shade to tiles. Note:- Tile shall be of premium quality (first quality) of reputed manufacturer like: RAK, NITCO, KAJARIA, SOMANI, JOHNSONS, ORIENTBELL, SIMPOLO. (Double charged tiles shall be used as approved by Engineer in charge. (NS). \nNote:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material. First Storeyitem15313.83Sqm
154154Second Storeyitem1541.3Sqm
155155Earth work non plastic or Tibba Sand under floors taken from outside of campus area with all lead and lift including loading, unloading, laid in 15 cm layer including ramming, watering, consolidating, compaction, and compensation of earth etc., complete in all respect as per the direction of engineer in charge. [NS].item1558966.59Cum
156156Providing and laying 200 mm thick granular sub base consisting of drainage layer confirming to Table 400.1 Grading –VI of MORT&H 5th edition, mixing in a mechanical mix plant at OMC, carriage of mix material to the site of work, spreading in uniform layer with motor grader on prepared surface and compacting with vibratory power roller to achieve desired density complete as per clause No.401 of MORT&H specifications for road & bridge (5th Revision) of 2013. (NS).item156226.56Cum
157157Providing & laying 75mm thick (Compacted) stone metal (G-II) 53mm to 22.4mm gauge waterbound macadam in layer of 75 mm each using screening type ‘B’ compacting with 3 wheeled steel roller/vibratory roller to achieve the desire density including lighting, guarding barricading and maintenance of diversion etc. as per clause No.404 of MoRT&H specifications for road & bridge (5th Revision) of 2013 as per drawing and design directed by the Engineer complete in all respects. (N.S).item15784.54Cum
158158Providing and laying 75 mm thick Dry Lean Cement Concrete Sub-Base Construction of dry lean Cement Concrete M-10 sub base over a prepared sub grade with coarse and fine aggregate conforming to IS 383 the size if course aggregate not exceeding 25mm aggregate cement ratio not to be exceed 15:1 aggregate gradation after blending to be as per table 60-1 of MoRT&H specification (5th edition) cement content not to be less than 150 kg/ cum optimum moisture content to be determined during trail length construction, concrete strength not to be less than as 10 MPA at 7 days mixed in the batching plant transported to site laid with a paver compacting with 5-10 tonne vibratory roller, finishing and curing as per clause 601 of MoRT&H specification (5th edition) 2013. \nNote:- If cement contents are required more than 150 Kg. per cum to achieve strength it will be incidental to work and nothing extra shall be payable on this account.item15884.54Cum
159159(PUBLIC HEALTH WORK):- Excavation of trenches in streets, lanes or in open areas for storm sewer, sewers running by gravity and manholes to full depths as shown in drawings including shoring, timbering of poling boards, frame system type, dressing to correct sections and dimensions, according to templates and levels, dewatering, provision for diversion of traffic, cutting trees and bushes, etc. night signals profiles, pegs, sight rails, boning rods, crossing over trenches for access to the houses, watching fencing etc. fixing and maintenance of caution board refilling of trenches, watering of refill, in 15 cm layers ramming and restoration of unmetalled or unpaved surface to original condition and removal of surplus soil, from site of work, upto a lead of 1 Km in oridnary soil. (a) for depths excavation not exceeding 3 metres below ground level. [HSR 6.10 (a)].item159387.76Cum
160160Boring for hand-pump in clay, fitting strainer and pipe (b) above 75 mm dia bore, but not exceeding 100 mm dia (i) from 0 to 15 meter. [HSR 26.10 (b)].item16033.1mtr.
161161Drilling and Tapping cast iron pipe lines of all diameters and screwing in ferrule and connections-Size of ferrule. [HSR 28.22]. (vi) 40 mm internal diameter of pipeline.item1614Each
162162Cutting holes upto 23 cm square through brick work in mud walls for pipes and making good including repointing replastering and finishing according to existing finish where required. [HSR 28.23]. (i) 11.43 cm thickness of wallsitem162216Each
163163(ii) 22.86 cm thickness of wallsitem163320Each
164164Labour for fixing G.I. or W.I. pipe sleeve pieces in holes in walls, floors, and roofs rounds pipes including all cutting and wastage. [HSR 28.27]. (a) 15 mm internal diameteritem1643Rmt
165165(b) 20 mm internal diameteritem1653Rmt
166166(c) 25 mm internal diameteritem1664Rmt
167167Bailing out water from the trenches for making new connections in fully charged pipe-lines including cleaning, trimming and dressing the trenches to correct alignment and grade as required by the Engineer-In-charge. [HSR 28.47 (a)]. Upto 200 mm internal diameteritem1674Each
168168Providing and placing in horizontal layers filtering media screened, washed and cleaned as described below: (HSR 28.50) (a) Filter media fine graded 1.5 mm to 3 mmitem16812.48Cum
169169(c) Filter media course Bajri 6 mm to 20 mmitem16912.48Cum
170170(d) Filter media boulders 50 mm to 75 mmitem17024.98Cum
171171Constructing brick masonry inspection chamber sizes as given below upto 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 percent limer mortar 2:3 in foundation cement concrete 1:2:4 benching 12 mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2;4 slab 100 mm thick./C.C. topping 50 mm thick with 455 mm x 455 mm 610 mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint coplete as per standard design. [HSR 29.84]. (a) Size 450 mm x 450 mmitem17124Each
172172(b) Size 450 mm x 600 mmitem17218Each
173173(c) Size 600 mm x 900 mmitem1735Each
174174Extra for over 0.30 metre depth of inspection chamber. (a) 450 x 450 mm. (HSR 29.85)item1746Mtrs. (as per 0.30 Mtrs. Depth)
175175Constructing brick masonry road gully chamber as per standard drawings (as per sizes given below) including dressing of beds and sides of chamber to exact profiles, 15cm thick lime concrete 16:24:100 (as per specified in item no 10.6) in foundation, Ist class brick work laid in cement sand mortar, 1:5, 40mm thick cement concrete 1:2:4, topping inside the chamber with a floating coat of 1.5 mm thick neat cement laid in one operation to the topping the entire inner surface of the chamber rendered with neat cement not less than 12 mm in thickness of 1:2 cement sand plaster and finished with a floating coat of neat cement 1 mm thickleft absolutely smooth polished and correct to templates including labour for fixing the C.I. road gully grating and frame including painting with coal tar (as specified in item no. 29.48 complete and to the requirement of the Engineer-In-charge). (a) Single Road Gully Chamber (i) Size 610 mm x 457 mm x 800 mm. [HSR 29.87 (a) (i)].item17520Each
176176CONSTRUCTION OF RECTANGULAR STANDARD BRICK MASONRY MANHOLE CHAMBERS to standard drawings on S.W pipe sewers or other circular pipe sewers upto the required depth in 1.5 CEMENT SAND MORTAR, lime concrete in bed and sides of pipe sewer and cement concrete 1:2:4 in benching, 12 mm thick water tight 1:2 cement sand plaster with a floating coat of neat cement and finished with 2 coats of sodium solicate on interior surface where required, reinforced cement concrete slab 180 mm thick fixing 560 mm internal diameter C.I. manhole cover and frame weight not less than 2.5 quintal painted with 3 coats of black bitumen paint, fixing galvanised malleable iron steps embedded in 1:2 cement sand mortar complete. \nThe rate cover the cost of M.S steel for R.C.C slab Labour for fixing and carriage of C.I manhole frame and cover and malleable iron steps from the stores of the Engineer-in-charge of the works to the site of works. The rate also includes the cost of accurately planned and fitted centring, supports for all works as well as for all curves and special work, cleaning out their beds etc. Sodium silicate shall be supplied free of cost at the stores of Engineer- in-charge. [HSR 29.90 (ii)]. (ii) On 150 mm I/d Pipe sewer(a) For 1.20 Mtrs. depth below ground levelitem17616Each
177177(b) For 1.50 Mtrs. depth below ground levelitem17716Each
178178(c) For 1.80 Mtrs. depth below ground levelitem1786Each
179179Providing, lowering, laying, cutting (cut surface to be uniformity finished) jointing with rubber rings marked with IS:5382 and testing of SPIGOT AND SOCKETTED RCC NP2 MARKED WITH IS:458-1988 and specials into trenches for all depths including carriage, loading, unloading, stacking, handling, re-handling etc. complete in all respects to the satisfaction to the Engineer -in-charge. (a) 200 mm dia. (HSR 29.93).item179335.37Rmt
180180Providing and fixing SFRC manhole covers and frames markd with IS: 12592 including setting the same to correct lines and levels in 1:2 cement sand mortar over manhole including carriage loading, unloading stacking, handling, re-handling etc. complete in all respect to the satisfaction of engineer-in-charge. Type: Extra heavy duty set (MD-10) 560 mm clear opening. (HSR 29.94)item1804Each
181181Providing SALT GLAZED STONE WARE PIPES GRADE 'A' IN STANDARD LENTH OF 600 MM EACH PIPE MARKED WITH IS;651 and their lowering, cutting, jointing and testing as described in HSR item no. 29.38, 29.39, 29.40 inlcuding the cost of jointing materials as well as carriage, loading, unloading, stacking handling, re-handling etc. complete in all respect to the satisfaction to the Engineer-in-Charge. (b) grade 'A' 150 mm. (HSR 29.95)item181289.02Rmt
182182Providing & Fixing in position best Indian make (to the approval of the Engineer-in-charge). Indian orissa or orya water water closet suite for sinking into floor, with raised foot treats complete with 100 mm H.C.I.'P' trap with or without vent as required and all other necessary fitting as fully described. (b) Size 630 mm (ii) Single Colour. (Make Hindware) [HSR 30.2 (b) (ii)].item1821Each
183183Providing and fixing in position best indian make (as approved by the engineer-in-charge European type water closet suite, syphonic type consisting of- (i) VITREOUS CHINAWARE SYPHONIC SUITE WITH 15 LITRES CAPACITY MATCHING CHINAWARE CISTERN and all internal brass fittings COMPLETE WITH ‘P’ or ‘S’ TRAP with or without vent; (as approved by the Engineer-in-charge). (ii) One piece SEAT AND LID IN HOLLOW BLACK OR WHITE PLASTIC fitted with chromium plated hinges and rubber buffers, (to the approval of the Engineer-in-charge) COMPLETE in all respects INCLUDING CUTTING AND MAKING GOOD THE WALLS AND FLOORS. (b) Double trap syphonic (ii) Single Color. [HSR 30.5 (b) (ii)].item18319Each
184184EXTRA OVER item nos. 30.1 to 30.4 and 30.6 FOR PROVIDING AND FIXING 15 LITRES CAPACITY C.I. LOW LEVEL VITREOUS CHINAWARE CISTERN complete with flush bend all other necessary Fittings instead of C.I high level cistern complete with fittings. (i) White. [HSR 30.12 (i)].item18420Each
185185EXTRA OVER item nos. 30.3 to 30.6 FOR PROVIDING AND FIXING BEST INDIAN MAKE PLASTIC HYGENIC SEAT with lid complete instead of hollow Black or white plaster seat and lid.(i) White plastic seat (Solid). [HSR 30.13 (i)].item18519Each
186186EXTRA FOR providing and fixing 32 MM dia G.I./C.P FLUSH PIPE complete with accessories instead of 32/MM dia galvanized telescopic flush pipe with clips (as required by the Engineer-in-charge). (i) 32 mm dia G.I. flush pipe. [HSR 30.15 (i)].item18620Each
187187Providing & Fixing in position best indian make (ordinary) lavatory suites consisting of:- (v) Size 560 mm x 450 mm with one no. tap. [HSR 30.41(v)].item18720Each
188188PROVIDING AND FIXING IN POSITION 32 MM DIA G.I. WASTE PIPE EMBEDDED IN WALL or lead waste pipe (weighing 3.47 kg. per metre and 2.8 mm thick) upto floor Level including cost of wipped solder joint etc., complete (as required by the Engineer-in-charge). [HSR 30.48].item18820Each
189189Providing and fixing in position best Indian make chromium Plated brass Bottle trap 32 mm dia metre. complete (as required by the Engineer-in-charge). [HSR 30.50]item18920Each
190190Providing and fixing in position best quality Stainless Steel Sinks with Complete fittings as fully described in item No. 30.51. (a) 600 mm x 450 mm x 200 mm. [HSR 30.53 (a)].item19011Each
191191Providing and fixing 40 mm I/D Stainless Steel waste pipe embedded in walls or lead waste pipe weighing 4.46 Kg./metre and 3.0 mm thick upto floor level as required by the Engineer-in-charge including cost of union and plumber joint. (HSR 30.62)item19111Each
192192Providing and fixing 40 mm i/d chromium plated brass trap with chromium plated bra pipe to wall with wall flange, complete (as per requirement of the Engineer-in-charge) for use with sinks. (a) with Bottle Trap (indian make). [HSR 30.63 (a)].item19211Each
193193Providing and fixing in position best indian make shower with 125 or 20 I/D in-let. (d) C.P. brass with telephonic shower. [HSR 30.66 (d)].item19319Each
194194PROVIDING AND FIXING IN POSITION BEST INDIAN MAKE PAPER HOLDERS FIXED INTO wall with C.P Brass screws complete in all respects INCLUDING CUTTING AND MAKING GOOD THE WALLS ETC. (a) C.P. Brass. [HSR 30.67 (a)].item19419Each
195195Providing and fixing in position best Indian make towel rails fixed in with rawlslugs embedded in walls with C.P. Brass screws, complete in all respect including cutting and making goods the walls etc.: (a) 25 mm dia, C.P. Brass adjustable. (i) 750 mm long. [HSR 30.68 (a)]item19531Each
196196Providing and fixing in position glass shelf fixed in with rawl plugs with C.P. Brass screws, complete including cutting and making good the walls etc. (a) with C.P. Brass brackets and guard rail. (i) 600mm x 125 mm . [HSR 30.69 (a) (i)].item19629Each
197197Providing and fixing in position best Indian make Soap dish fixed into wall with C.P. brass screws and complete in all respects including cutting and making goods the walls etc. (a) C.P. Brass (i) Soap dish Large. [HSR 30.70 (a) (i)].item19729Each
198198Providing & fixing in position best Indian make bevelled edge 5.5 mm thick mirror mounted on absetos sheet ground fixed in postion by means of 4 Nos. chromium plated brass screws and washers over rubbers washers and rawl plug embeded in the wall or chromium plated brass clamps with C.P. brass screws (as required by the engineer-in-charge) complete including cutting and making good the walls etc. (a) Indian Make (i) 600 mm x 450 mm. [HSR 30.71 (a) (i)].item19831Each
199199PROVIDING AND FIXING IN POSITION BEST INDIAN MAKE COAT AND HAT HOOKS fixed into wall with C.P Brass screws and rawl plugs etc. COMPLETE INCLUDING CUTTING AND MAKING GOOD THE WALLS ETC. (a) C.P. Brass. (ii) Two Way. [HSR 30.73 (a) (ii)].item199107Each
200200Providing and fixing in position super quality 65 mm i/d opening C.P brass dome type hinged grating weighing about 750 gms fixed in cement mortar 1:2 complete in all respects (as required by the Engineer-in-charge). [HSR 30.74].item20095Each
201201Providing and fixing in position 15mm i/d C.P. brass bib cocks of best quality (as required by the Engineer-in-charge). [HSR 30.75]. (a) Bib cock long body.item20189Each
202202Providing & fixing in position C.P. brass stop cock (as approved by the engineer-in-charge). (a) 15 mm Stop cock. (ii) Concealed stop cock with flange. [HSR 30.76 (a) (ii)].item202114Each
203203Providing and fixing C.P brass liquid soap container of best quality (as required by the Engineer-in-charge). [HSR 30.77].item20323Each
204204Providing and fixing in position best Indian make C.P. brass Tooth Brush cum Tooth Paste Holder fixed in with rawl plugs with C.P. brass screws complete including cutting and making good the wall etc. (ii) Tooth Brush Holder. [HSR 30.79 (ii)].item20429Each
205205Providing and fixing of best Indian make C.P. Brass wall mixer 15 mm. (a) With Telephonic Shower. [HSR 30.81 (a)].item20520Each
206206Providing and fixing in position best Indian make flexible tube connection. (b) C.P. Brass (iii) 15mm x 450 mm. [HSR 30.82 (b) (iii)].item206114Each
207207Providing and fixing in position H.C.I. Soil waste vent or antisyphonage pipes to I.S.I. specifications of E.L.C. manufacture or of any other reputed firm including cutting and wastage etc. and cutting holes in walls, roofs or floor etc. and making good to its original condition but excluding cost of lead jointing. (HSR 30.84) (a) 100 mm internal diameter.item207286.89Rmt
208208(b) 75 mm internal diameter.item208499.38Rmt
209209Providing and fixing in position C.I. Gully trap cover weighing approximately 7.26 Kg. and frame for gully trap chamber clear opening size 300 mm x 300 mm and out side size 330 mm x 330 mm including painting the exposed surfaces with 3 coats of black bitumastic superior paint of approved manufacture etc. (HSR 30.85).item20936Each
210210Providing lead caulked joints to H.C.I. pipes and specials confirming to I.S.I. specificationsof E.L.C. manufacture or any other reputed firm including cost of lead yarn, fuel and tools etc. (HSR 30.87). (a) 100 mm internal dia meter. (1.13 Kg)item210820Each
211211(b) 75 mm internal dia meter. (0.91 Kg)item211623Each
212212Providing and fixing in position M.S. or heavy flat iron clamps made out of M.S. flat not less than 5 mm of the approved design for fixing C.I. soil waste vent or anti pipes to walls complete in all respects. (a) for 100 mm interal diameter pipes. (HSR 30.88). (a) for 100 mm interal diameter pipes.item212141Each
213213(b) for 75 mm interal diameter pipes.item213214Each
214214Providing & Fixing H.C.I. floor traps I.S.I. marked of the self cleaning design with C.P. brass hinged grating with frame with or without vent arm and including cement concrete 1:2:4 under and around the floor trap where required upto floor level complete in all respects including cutting and making good the walls and floors, etc. minimum depth of water should be 50 mm with a minimum seal of 50 mm. (b) with 75 mm i/d outlet. [HSR 30.89 (b)].item21489Each
215215Providing and fixing in position H.C.I. specials for soils, waste, vent or anti-syphonage pipes to I.S.I. marked including cutting and waste etc. cutting holes in walls roofs or floors etc., and making good to its original condition but excluding cost of lead jointing. (HSR 30.91). (a) For 100 mm dia pipes (1) Heal rest benditem21513Each
216216(2) Double Junction with door 100 mm x 100 mm x 100 mm x 100 mmitem21640Each
217217(4) Single Junction with door 100 mm x 100 mm x 100 mm x 100 mmitem21740Each
218218(13) Bend with Dooritem21857Each
219219(14) Bend Plainitem219124Each
220220(16) Cowlsitem22013Each
221221(17) Door pieceitem22113Each
222222(22) Collarsitem222160Each
223223(b) For 75 mm dia pipes:- (1) Heal rest benditem22320Each
224224(3) Double Junction with door 75 mm x 75 mm x 75 mm x 75 mmitem22456Each
225225(4) Single Junction with door 75 mm x 75 mm x 75 mm x 75 mmitem22556Each
226226(13) Bend with Dooritem22681Each
227227(14) Bend Plainitem227180Each
228228(16) Door pieceitem22820Each
229229(17) Cowlsitem22920Each
230230(18) Collarsitem230220Each
231231Providing and fixing in position automatic brass ball valves in tanks. (b) With Plastic Ball (ii) 20 mm internal diameter. [HSR 30.110 (b) (ii)].item23130Each
232232Providing & Fixing in position gully traps fixed in cement concrete 1:4:8 complete with H.C.I. grating 150 mm x 150 mm cast iron cover weighing approximately 7.26 Kg. and frame clear opening 300 mm x 300 mm and outside size 330 mm x 330 mm and chamber including cost of all brick work in cement mortar 1:5 cement concrete 1:2:4, in coping black bitumastic superior paint of approved manufacture on all C.I. work as per standard design, minimum depth of water should be 150 mm with a minimum seal 50 mm. (b) 100 internal diameter H.C.I. gull trap. [HSR 30.114 (b)].item23236Each
233233Providing and Fixing HDPE WATER STORAGE TANKS of Sintex, Diplast, O.K. Supreme make with covers/lids marked with IS:12701 on roof top of buildings including cost of hoisting and placing in position, making connections with inlet and outlet pipes, providing overflow and scour provisions with suitable plug on scour pipe including cost of nipples, washers flages for connections in tanks complete in all respects to the satisfaction to the Engineer-in-Charge. [HSR 30.119]. 1000 Ltrs. Capacity Water Tankitem23330Each
234234DSR ITEMS:- Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall. (DSR 18.10) (i) 15 mm internal diameter of pipelineitem23476.51Rmt
235235(ii) 20 mm internal diameter of pipelineitem23583.88Rmt
236236(iii) 25 mm internal diameter of pipelineitem236328.96Rmt
237237(iv) 32 mm internal diameter of pipelineitem23795.43Rmt
238238Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. concealed pipe, including painting with anticorrosive bitumastic paint, cutting chases and making good the wall : (DSR 18.11) (i) 15 mm internal diameter of pipelineitem238178.52Rmt
239239(ii) 20 mm internal diameter of pipelineitem239195.7Rmt
240240Providing and fixing gun metal gate valve with C.I. Wheel of approved quality (Screwed end). (DSR 18.17) (b) 20 mm nominal boreitem24088Each
241241(c) 25 mm nominal boreitem24126Each
242242(d) 32 mm nominal boreitem24210Each
243243Providing and fixing G.I. Union in G.I. pipe including cutting and threading thye pipe and making long screws etc. complete (New Work). (DSR 18.46) (a) 15 mm nominal boreitem243101Each
244244(b) 20 mm nominal boreitem244165Each
245245(c) 25 mm nominal boreitem24592Each
246246(d) 32 mm nominal boreitem24635Each
247247NS ITEMS:- Providing & fixing PVC pipe (4kg/cm2) duly slotted IS-4985:1988 including cost of adhesive, carriage, loading, unloading etc. complete in all respects to the satisfaction engineer incharge. Make:- Supreme, Diplast or any reputed make as approved by Engineer-Charge. (i) 160 mm i/d (NS)item24732.5Mtrs.
248248Providing and fixing Steel bar embedded plastic steps of size 263 mm x 165 mm of orange colour, conforming to specifications, in pump chambers, manholes etc. having minimum 3 mm thick Polypropylene polymer confirming to IS : 10910 encapsulated on 12 mm dia ribbed steel bars per IS : 1786. (NS).item24824Each

AI Tender Summary

OUR REF NO 23309904
AUTHORITY Government Departments
TENDER VALUE 3.02 Crore
LAST DATE 10-02-2020
Authority
Authority Name Public Works Department
Work Description Construction Of Various Residential Houses In S . D . O . Civil Complex At Kalayat In Kaithal Distt .
Basic Detail
Tender No SDO Kalayat Residences
Bidding Type Tender
Location
City Kalayat
State Haryana
Key Dates
Publish Date 20 Jan 2020
Submission Date 10 Feb 2020
Open Date 11 Feb 2020
Finance
Tender Value 3.02 Crore
Tender Fee 15000
EMD 6.05 Lakhs
Exemption Not Available
Document List
BOQ_158001.xls
Tendernotice_1.pdf
9E799DAF-076B-44E9-8A3D-909888E33DFC.html
DNIT.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 20, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
Feb 10, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Feb 11, 2020

Bid Opening Date

Technical bids will be opened and evaluated.