Military Engineer Services-MES has published Repair To Joinery , Flooring , Plastering , Plumbing , Tilling , Sanitary Fitting And Periodical Services And Repair Of Internal Electrification And Maint Of Summer Appliances At Kota Raipur Mil Station. Submission Date for this Tender is 11-02-2020. Electrification Work Tenders in AGE (I) Naya Raipur Chhattisgarh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 06-Feb-2020 | Datecorrigendum | Date | 11-02-2020 |
Name of Work : REPAIR TO JOINERY, FLOORING, PLASTERING, PLUMBING, TILLING, SAINTARY FITTING AND PERIODICAL SERVICES AND REPAIR OF INTERNAL ELECTRIFICATION AND MAINT OF SUMMER APPLIANCES AT KOTA RAIPUR MIL STATION | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Taking down GI tubing 15mm bore of any description including cleaning for refixing or removal to store complete all as specified and directed. | 12 | RM | |
2 | 2 | All as per item No. 1.00 here in above but 20mm bore complete all as specified & directed. | 12 | RM | |
3 | 3 | M & L for providing tubes 'medium grade' galvanised of bore 15mm dia, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified & directed. | 6 | Rm | |
4 | 4 | All as per item No 3 above but 20mm bore complete all as specified & directed. | 6 | RM | |
5 | 5 | Refixing old GI pipe 15 mm bore & connections in new or old position to walls and ceiling or laid in floor all as specified & directed. | 6 | RM | |
6 | 6 | Refixing old GI pipe 20 mm bore & connections in new or old position to walls and ceiling or laid in floor all as specified & directed. | 6 | RM | |
7 | 7 | S&F in repair ball valve high pressure of PTMT 15 mm dia with epoxy coated aluminium rod and high density plastic ball complete all as specified & directed. | 8 | Each | |
8 | 8 | S&F in repair ball valve high pressure of PTMT 20 mm dia with epoxy coated aluminium rod and high density plastic ball complete all as specified & directed. | 8 | Each | |
9 | 9 | S&F in repair vitreous China squatting pass, 'orissa' pattern size 580 x 440 mm white with integral foot rest complete all as specified & directed. | 2 | Each | |
10 | 10 | S&F in repair viteress china wash down water closet pan (Pedestal PATTERN) ,white(excluding fixing bolts,flushing cistern and flush pipe) including plastic water closet seat black,closed pattern with flat bottom,and cover and mild steel chromium plated or aluminium hinging devicet and flush pipe complete including provision of concrete bedding 1:2:4 type BO complete all as specified & directed. | 3 | Each | |
11 | 11 | S&F PVC (SWR) 'P’ trap complete all as specified and as directed. | 3 | Each | |
12 | 12 | S&F in repair Vitreous china wash basin, white, flat back, size 550 x 400mm, including brackets and cutting for and pinning in ends of brackets, complete all as specified & directed. | 4 | Each | |
13 | 13 | S&F in repair grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified & directed. | 10 | Each | |
14 | 14 | S&F CP 20mm dia tubular towel rail 600mm long complete all as specified and directed. | 5 | Each | |
15 | 15 | S&F 40mm dia PVC pipe low density (LDPE) of pressure 6kg/CM2 fixed to wall or laid in floor as waste pipe. | 6 | RM | |
16 | 16 | S&F 600x450x5mm bevelled edge looking mirror of selected quality glass, mounted on 6mm thick AC building or commercialplywood and fixed with to wooden plug with chromium plated brass screw and cup washer all as specified and directed. | 3 | Each | |
17 | 17 | S&F in repairs brass chormium plate shower rose 125 mm size including fixing to steel tube all as specified and directed. | 6 | Each | |
18 | 18 | S&F 75 mm out let cast Iron floor trap with chromium plated grating including Jointing to waste pipe and fixed in cement concrete B1 (1:2:4 ) using 20 mm graded stone aggregate all as spcefied and directed | 1 | Each | |
19 | 19 | Demolition and breaking up or down PVC /AC/CI /Cement rain pipe fixed in any position all as specified and directed | 48 | RM | |
20 | 20 | S&F 110mm dia PVC(SWR) pipes single soketed in any length with rubber ring jointed fixed to wall complete all as specified | 24 | RM | |
21 | 21 | S&F 75mm dia PVC(SWR) pipes single soketed in any length with rubber ring jointed fixed to wall complete all as specified | 24 | RM | |
22 | 22 | S&F PVC (SWR) bends 110 mm dia all as specified and directed | 3 | Each | |
23 | 23 | S&F PVC (SWR) bends 75 mm dia all as specified and directed | 3 | Each | |
24 | 24 | S&F PVC (SWR) cowl 110 mm dia all as specified and directed | 3 | Each | |
25 | 25 | Dismantling PVC water tanks and removing for capacity exceeding 250 litres & not exceeding 500 litres etc complete all as specified & directed. | 2 | Each | |
26 | 26 | Dismantling PVC water tanks and removing for capacity exceeding 500 litres & not exceeding 1000 litres etc complete all as specified & directed. | 2 | Each | |
27 | 27 | S & F Rotational moulded polyethylene water storage tanks of capacity 1000 liters (Cylindrical vertical with closed top) hoisted and fixed in position complete all as specified & directed. | 2 | Each | |
28 | 28 | S & F Rotational moulded polyethylene water storage tanks of capacity 500 liters (Cylindrical vertical with closed top) hoisted and fixed in position complete all as specified & directed. | 2 | Each | |
29 | 29 | S&F in repair 20 mm bore gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe all as specified & directed. | 4 | Each | |
30 | 30 | S&F 25 mm nipple suitable for HDPE water tanks including necessary driling holes etc fixed complete. | 6 | Each | |
31 | 31 | M&L for preparation of old painted steel / iron surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel painting all complete as specified and as directed. | 20 | Sqm | |
32 | 32 | M&L for complete removal of old painted wooden surfaces of any description not otherwise described over 10 cms width or girth including knotting and stopping and applying two coat of synthetic enamel paint over one coat of primer, complete all as specified. | 20 | Sqm | |
33 | 33 | M&L for two coat Cement base paint on old plastered surface including prepration of surface all as spcefied and directed | 500 | Sqm | |
34 | 34 | M & L for preparation of plastered or unplastered old surface and applying two coats of white wash as in ceilings complete all as specified & directed. | 50 | sqm | |
35 | 35 | M & L for preparation of plastered or unplastered old surface and applying three coats of white wash as on walls complete all as specified & directed. | 200 | sqm | |
36 | 36 | M & L for preparation of plastered or unplastered old surface and applying two coat with oil bound distemper as on walls complete all as specified & directed. | 500 | sqm | |
37 | 37 | Taking down Shutters of any description exc 1 Sqm and not exc 2 sqm each removing to or from store complete all as specified and directed. | 8 | Per Leaf | |
38 | 38 | Taking down chowkats or frames with shutters (with out taking off shutter from frames) not exc 1.5 Sqm each and making good of disturbed surface match the existing surface all as spcefied and directed | 6 | Each | |
39 | 39 | S&F PVC solid door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube.fixing as per specification and drawing complete all as specified and directed. | 29 | RM | |
40 | 40 | S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tube for top and bottoms rail. MS frame sall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stile and plain colour PVC sheet for top rail, lock rail and bottum rain on either side as gap insert for top rail and bottom rail, panelling of pain colour PVC sheet to be fitted in the MS frame welded to the styles and rails with sutaible PVC sheet beading and jointed together with solvent cementcomplete all as specified & directed. | 9 | Sqm | |
41 | 41 | M & L for 2nd class hard wood factory made, plain framed, panelled shutters (two panels) with lock rail and panel of 12mm veneered particle board with commercial veneers on both faces. The size of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated, 35 mm thick fitted to chowkates, complete all as specified & directed. | 6 | Sqm | |
42 | 42 | Material and labour second class hard wood 35 mm thick glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc., with out sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc, sizes of members of shutters as specified in SSR part I section 8 clause 8.20 (a) complete all as specified and directed. | 14 | Sqm | |
43 | 43 | S&F Butt hinges, medium weight, 100mm cold rolled mild\nsteel, and welded to existing iron frame complete all as specified and as directed. | 42 | Each | |
44 | 44 | S&F 150 mm extruded aluminium alloy handle anodised fabricated type and fixed with MS screws complete all as specified & directed. | 42 | Each | |
45 | 45 | S&F aluminium anodised barrel tower bolt extruded section 150 mm long and fixed with MS screws complete all as specified & directed.. | 42 | Each | |
46 | 46 | S&F 300 mm extruded section aluminium alloy anodised, sliding door bolt with hasp and staple and fixing clip of sheet and fixing bolt and nut complete all as specified & directed. | 4 | Each | |
47 | 47 | S & F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor overall length of cover plate is 140mm complete all as specified & directed. | 8 | Each | |
48 | 48 | M & L for hacking out old serviceable glass of any description, from old wooden or metal frames; any thickness or size; hacking out old putty or removing beads etc, including making good breakages in taking out and handling removing to store | 2 | Sqm | |
49 | 49 | M & L for sheet glass of thickness 3mm, ordinary quality and glazing with oil putty or wooden beading for securing the glass in square n exc 0.5 sqm in each pan complete all as specified and directed. | 5 | Sqm | |
50 | 50 | Material and labour for stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aprature 1.40 mm and fixed with stainless steel wire staple complete all as specified and directed. | 10 | sqm | |
51 | 51 | Supply and fix in repair for stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with satainless steel wire staples complete all as specified and directed. | 25 | Sqm | |
52 | 52 | Material and labour for prepration of new wooden surfaces and applying two coats of synthetic enamel paint over a coat of pink primer of any description over 10cm width or girth complete all as specified and directed. | 30 | Sqm | |
53 | 53 | S & f for 300 mm long mild steel helical door, springs including roller and roller plate enamelled black fixed to wooden chowkat, complete all as specified. | 8 | Each | |
54 | 54 | M & L for demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified & directed. | 5 | Cum | |
55 | 55 | M&L PCC 1:4:8 type D2, 100mm thick (40mm graded aggregate) as in sub base, sub floors and pavings, etc. | 25 | Sqm | |
56 | 56 | M&L PCC 1:2:4 type B2, 40mm thick (20mm graded aggregate) as in sub base, sub floors and pavings, etc. | 25 | Sqm | |
57 | 57 | M&L 75 mm thick PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in Sub base and plinth protection finish the cement concrete surfaces fair and even laid in bays complete all as spciified and directed | 20 | Sqm | |
58 | 58 | Taking down cement plaster on brick or stone walls etc including raking out joints hacking for key, scrubbing down with water etc complete all as specified & directed. | 40 | Sqm | |
59 | 59 | M&L for 15 mm thick cement plaster on external surfaces of wall in CM 1:4 including finished surfaces even and somooth without using extra cement mixed with WPC as per manufacturer instructions .(Note :- WPC shall be measured & paid separately) | 40 | Sqm | |
60 | 60 | Supply only water proofing compound of approved make | 10 | Kg | |
61 | 61 | M & L for dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing servicable tiles to store and rubbish off the premises complete all as specified & directed. | 38 | Sqm | |
62 | 62 | M & L for 15mm thick Screed bed or bedding layer of mortar (1:6) for laying floor finishes complete all as specified & directed. | 15 | Sqm | |
63 | 63 | M & L Non - skid Ceramic coloured tiles 7 to 8 mm thick (Square or rectangular) area of each tile exceeding 0.06 sqm but n. exc 0.11 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles complete all as specified & directed. | 16 | Sqm | |
64 | 64 | M & L for glazed ceramic tiles in vertical surface 300x200x6 to 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the existing surface and shade over 10 mm thick cement mortar of 1:4 complete all as specified & directed. | 16 | sqm | |
65 | 65 | M & L 25 mm thick cemnt concrete type B-1, 1:2:4 ( 20 mm graded aggregate) as in floor finished rough to receive tiles complete all as specified & directed. | 16 | Sqm | |
66 | 66 | S&F in repair 10 Ltr PVC valveless, syphonic action type flushing cystern low level with inlet, ball valve, float and handle including brackets and PVC out let sutaible for IWC complete all as specified & directed. | 5 | Each | |
67 | 67 | S&F in repair PVC connections 15mm size with PTMT nuts of length 450 mm complete all as specified & directed. | 10 | Each | |
68 | 68 | S&F in repair PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified & directed. | 10 | Each | |
69 | 69 | S&F in repair waste coupling with waste pipe of PTMT(half or full threaded) .(Minimum weight 32mm-45gms/40mm-60 gms)for WHB complete all as specified and as directed. | 4 | Each | |
70 | 70 | S&F in repair waste coupling with waste pipe of PTMT(half or full threaded). (Minimum weight 32mm-45gms suitable for urinals complete all as specified and as directed. | 4 | Each | |
71 | 71 | S&F in repair pillar taps, 15mm dia cast copper alloy fancy type , with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed. | 10 | Each | |
72 | 72 | S&F in repair bib taps, 15mm chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed. | 30 | Each | |
73 | 73 | S&F in repair 15mm bore angle valve /stop valve chromium plated fency type.cast copper alloy screwed down high pressure,crutch or butterfly handle, ,screwed both end for pipe or for unions complete.chromium plated with suitable type as directed | 20 | Each | |
74 | 74 | Taking down carefully copper/Aluminum point wiring (light, fan, socket or power) complete, including fittings such as switches, ceiling roses, pendants, regulators sockets etc. and making good the disturbed surfaces of walls, floors etc and match with the existing colour of wall complete all as specified and as directed. | 57 | Each | |
75 | 75 | Taking down carefully sub main wiring of any Nos of wire & size with earth wire on wooden batten/surface PVC and metallic conduit/casing & capping with accessories complete all as specified and as directed. | 35 | RM | |
76 | 76 | M&L Point wiring complete with 1.5 sqmm PVC insulated stranded copper conductor single core cable drawn through and including rigid non metalic PVC conduit 20 mm dia ( meadium grade ) , ISI marked with concealed conduit wiring including cutting chases and making good in CM 1:3 & white/colour wash to match existing surface, pressed steel terminal boxes not less than 1.6 mm thick concealed in wall duly painted with two coat of black bituminous paint over a coat of red oxide primer, plastic laminated top sheet cover 2.8 mm thick of required size and colour for housing switches and sockets, 1.5 sqmm PVC insulated (green insulation) copper conductor as earth continuity cable drawn with wiring and connected to common earth dolly all as specified for - | |||
77 | 76.01 | (a) One light/Fan/Bell point controlled by one switch | 20 | Per Point | |
78 | 76.02 | (b) One light point controlled by two 2 way switch | 5 | Per Point | |
79 | 76.03 | (c) One socket out let 5 pin 5 Amp on independent board | 12 | Per Point | |
80 | 76.04 | (d) One socket out let 5 pin 5 Amp on same board | 10 | Per Point | |
81 | 77 | Description all as per item No 04 above but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed cable for 3/6 pin 5 & 15 Amp socket outlet controlled by one switch on independent board with and including 1.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete all as specified and as directed. | 10 | Per Point | |
82 | 78 | Taking down and S&F Switch , Single pole, one way, 6 amps, 230 Volts,all specifed and directed | 30 | Each | |
83 | 79 | Taking down and S&F Switch, Single pole, one way,16 amps, 230 Volts, all as specifed and directed | 15 | Each | |
84 | 80 | Taking down and Supply and fixing socket 6/16 amps- 2/3 pin combined module box type (as per site required ). | 15 | Each | |
85 | 81 | Taking down and S&F switch , Single pole, two way, 6 amps, 230 Volts, all as spcified and directed | 4 | Each | |
86 | 82 | Taking down and Bell push , Single pole, one way, 6 amps, 230 Volts, all as specifed and directed | 6 | Each | |
87 | 83 | Taking down and S&F socket , Single pole, one way, 6 amps, 230 Volts, all as specifed and directed | 4 | Each | |
88 | 84 | Taking down and S& F electronic fan regulator 5 step of all as specifed and directed | 10 | Each | |
89 | 85 | Supply and fixng of sheet metal metal enclosure DB 8 way with 200 amp rated bus bar | 2 | Each | |
90 | 86 | Taking down and S & F SP, isolator 40 ampss, 240 Volts , 10 KA , 'c' curve MCBs complete all as specified and directed :- (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating). | 10 | Each | |
91 | 87 | Taking down and S & F SPN, 40 Amps, 240 Volts , 10 KA , 'c' curve MCBs complete all as specified and directed :- (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating). all as specifed and directed by engr-in-charge | 5 | Each | |
92 | 88 | Taking down and S & F TPN32to 63 Amps, 440 Volts , 10 KA , 'c' curve MCBs complete all as specified and directed :- (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating). all as specifed and directed | 4 | Each | |
93 | 89 | Supply and fixng of sheet metal metal enclosure DB 4 way with 200 amp rated bus bar 230 volt all as specifed and directed nby engr-in-charge | 4 | Each | |
94 | 90 | Taking down and S&F ding dong bell 230 volt single phase complete all as specified and directed complete .all as specified and directed | 6 | Each | |
95 | 91 | M & L for sub main wiring with PVC insulated sheathed two single core 4 Sqmm and One No. 2.5 Sqmm single core cable stranded copper conductor 1100 Volt grade to be use as continuous earth connected to earth drawn into PVC conduit/Casing N capping size not less than 25 mm (medium grade) with all accessories complete all as specified and as directed. Note : Two runs of cable for Sub Main and One run of earth wire shall be measured as One length with PVC conduit / casing-N-caping. all as specifed and directed | 35 | RM | |
96 | 92 | Taking down defective fluorescent tube light fittings of any type all as specified and as directed. all as specified and directed \n | 300 | Each | |
97 | 93 | S & F in repaires of batten for LED tube light fitting with suitable for 1 x 20 watts 230 volts 4 feet long Energy efficiency etc complete set with all accessories internally pre wired and incl connection from ceiling rose to tubelight fitting 3 core flexiable copper cable 0.75 sqmm compete and connection. all as specifed and directed by engr-in-charge | 300 | Each | |
98 | 94 | Taking down defective LED lamp of any type and capacity of any type all as specified and as directed. all as specified and directed \n | 75 | Each | |
99 | 95 | S&F in repair of LED lamp of 9 watt retrofit type all as specified and directed by engr-in-charge | 75 | Each | |
100 | 96 | Total contracts sum shall be calculated after deduction of schedule of credit amount of Rs. 23628.00 |