Council Of Scientific And Industrial Research-CSIR has published To Carry Out Visual Inspection, Distress Mapping, Non-Destructive Tests (Ndt), Partially Destructive Tests (Pdt), Laboratory Investigations For Determination Of Parameters Related To Quality, Strength & Durability And Submission Of Detailed Report For Rcc. Submission Date for this Tender is 27-01-2020. Industrial Ultrasonic Testing Tenders in Director CSIR-CBRI ROORKEE Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

23277654
To Carry Out Visual Inspection, Distress Mapping, Non-Destructive Tests (Ndt), Partially Destructive Tests (Pdt), Laboratory Investigations For Determination Of Parameters Related To Quality, Strength & Durability And Submission Of Detailed Report For Rcc
Open Tender
Indian
Uttarakhand
Director CSIR-CBRI ROORKEE
27-01-2020

Tender Details

To Carry Out Visual Inspection, Distress Mapping, Non-Destructive Tests ( Ndt ) , Partially Destructive Tests ( Pdt ) , Laboratory Investigations For Determination Of Parameters Related To Quality, Strength & Durability And Submission Of Detailed Report For Rcc Members Of The 70 Flats In 5 Towers Having Basement+Stilt+8, Stilt+8, Stilt+5 ( 1No. Each ) & Stilt+7 ( 2Nos. ) Located At Judge’S Colony Sector-19, Dwarka, New Delhi

Key Value

Document Fees
Refer document
EMD
INR 20000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: To carry out visual inspection, distress mapping, non-destructive tests (NDT), partially destructive tests (PDT), laboratory investigations for determination of parameters related to quality, strength & durability and submission of detailed report for RCC members of the 70 flats in 5 towers having Basement+Stilt+8, Stilt+8, Stilt+5 (1No. each) & Stilt+7 (2nos.) located at Judge’s Colony Sector-19, Dwarka, New Delhi
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Site Investigation BI01010001010000000000000515BI0100001112
2 1.1 Distress Mapping based on existing drawings: Site visits by qualified and experienced civil engineer for visual inspection by light tap hammer, crack gauges etc. Submission of visual inspection report of the structure including photographic evidence. Preparation of distress drawings including structural crack mapping using crack gauge, identifying delamination, spalling/ honeycombed areas, damp locations, discolorations etc. Marking damaged areas on drawing for record and future references BI01010001010000000000000515BI0100001113 1 LS
3 2 Material characterization of the existing structure by ND / PD Testing including field and laboratory tests, preparation & submission of ND / PD test report for RCC elements BI01010001010000000000000515BI0100001114
4 2.1 Ultrasound pulse velocity tests for establishing the integrity and soundness of concrete (Ref. IS: 13311 - —Part 1 BI01010001010000000000000515BI0100001115 300 Nos
5 2.2 Schmidt’s rebound hammer test for determining the concrete compressive strength (Ref. IS: 13311- Part-2) BI01010001010000000000000515BI0100001116 300 Nos
6 2.3 Taking out concrete cores (approx. 70mm Dia), preparing specimen for lab testing, performing lab test for compressive strength and density (Ref. IS: 456-2000 & IS: 516-1959 (reaffirmed in 2004) BI01010001010000000000000515BI0100001117 30 Nos
7 2.4 Assessment of probability of carbonation present in concrete. (BS 1881-201 1986 clause 2.22) BI01010001010000000000000515BI0100001118 40 Nos
8 2.5 Half-cell potential tests for assessing extent of corrosion in the reinforcement (ASTM C 879:1991) BI01010001010000000000000515BI0100001119 100 Nos
9 2.6 Chemical Analysis Test (i) Ph of the concrete, IS: 3025 (Part 11):1983 (ii) Chloride content in concrete, IS-14959(Part 2):2001 (iii) Sulphate content in concrete, BS 1881(Part 124) BI01010001010000000000000515BI0100001120 300 Nos
10 2.7 ICOR test for Advance Reinforcement Corrosion assessment of RCC Elements by measuring corrosion rate, in-situ Electrical resistivity and Corrosion potential of Rebar. BI01010001010000000000000515BI0100001121 25 Nos
11 3 Submission of detailed report mentioning all test results and their linking with distress. BI01010001010000000000000515BI0100001122 1 LS