Health and Family Welfare Government Departments Closing in 0 days TDR #23241079

Comprehensive Annual Maintenance Contract For The Works Given As Item Description At Drugs Testing Laboratory , Thiruvananthapuram During The Financial Year 2020-21

Issued by Government Departments · Vanchiyoor, Kerala
Tender Value
4 Lakhs
Estimated cost
Bid Submission
22 Jan 2020
0 days left
EMD
4000
Bank guarantee accepted
Document Fee
800
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Vanchiyoor → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Comprehensive Annual Maintenance Contract For The Works Given As Item Description At Drugs Testing Laboratory , Thiruvananthapuram During The Financial Year 2020-21 , Microbiology Lab - Camc , I ) Clean Room Validation As Per Grade A , B , C & D ( I ) Air Flow Velocity ( Ii ) Air Changers Per Hour ( Iii ) Filter Integrity Test ( Iv ) Differential Pressure ( V ) Recovery Time ( Vi ) Room Temperature & Humidity ( Vii ) Particle CountIi ) Maintenance , Servicing & Overhauling Works Of Hvac SystemA ) Air Handling Units - 3 Nos ( 8 . 5 Ton X 2 Nos . & 5 . 5 Ton X 1 No . ) ( I ) Flushing And Cleaning Of Finned Surface & Dx Tubes Of Cooling Coils ( Ii ) Checking & Replacement Of Faulty Fan Bearing ( Iii ) Checking & Replacement Of Faulty Motor Bearing ( Iv ) Checking Of Belt Allignment And Tension & Mounting Bolts . ( V ) Cleaning Of Filters , Replacement Of Defective Belts , Pulleys , Blowers , Shafts , Bearings Of Ahus Whenever Found Defective . B ) Electrical Panels And Wiring ( I ) Checking And Servicing Of Contactors , Capacitors , Overloads , Mccbs And Fuses , Tightening Of Wiring Connections And Replacement Of Faulty Parts If Required . ( Ii ) Checking Of Wiring Insulations & Motor Winding ( Iii ) Checking Of Earthing . C ) Outdoor Units - 3 Nos ( 8 . 5 Ton X 2 Nos . & 5 . 5 Ton X 1 No . ) Flushing & Cleaning Of Finned Surface Of Condenser , General Change Of Compressor Oil If Required , Greasing Of Bearing And Oiling Wherever Required , Replacement Of Motors And Compressor If Required . Topping Of Refrigerant Whenever Required . Rectification Of Leak If Any And Testing The System With Nitrogen Pressure And Re-Commissioning After Vaccumization , Replacement Of Insulation Sleeves On Copper Tubings . Iii ) Other WorksValidation Frequency : 2 Tests Per YearBreakdown Attendance: Within 24 Hrs .

BOQ

Name of Work: Entering for Comprehensive Annual Maintenance Contract for the Works given as Item Description at DTL, Thiruvananthapuram during the Financial Year 2020-21
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Microbiology Lab - CAMCBI01010001010000000000000515BI0100001112
21.01I) Clean Room Validation as per grade A, B, C & D\n(i) Air Flow Velocity (ii) Air Changers per Hour\n(iii) Filter Integrity Test (iv) Differential Pressure\n(v) Recovery Time (vi) Room Temperature & Humidity\n(vii) Particle Count\nII) Maintenance, Servicing & Overhauling works of HVAC System\nA) Air Handling Units - 3 Nos (8.5 Ton x 2 Nos. & 5.5 Ton x 1 No.)\n(i) Flushing and Cleaning of Finned Surface & DX Tubes of Cooling Coils\n(ii) Checking & Replacement of faulty Fan Bearing\n(iii) Checking & Replacement of faulty Motor Bearing\n(iv) Checking of Belt Allignment and Tension & Mounting Bolts.\n(v) Cleaning of Filters, Replacement of Defective Belts, Pulleys, Blowers, Shafts, Bearings of AHUs whenever found defective.\nB) Electrical Panels and Wiring\n(i) Checking and Servicing of Contactors, Capacitors, Overloads, MCCBs and Fuses, Tightening of wiring connections and Replacement of faulty parts if required.\n(ii) Checking of Wiring Insulations & Motor Winding\n(iii) Checking of Earthing.\nC) Outdoor Units - 3 Nos (8.5 Ton x 2 Nos. & 5.5 Ton x 1 No.)\nFlushing & Cleaning of finned surface of condenser, General Change of compressor oil if required, greasing of bearing and oiling wherever required, replacement of motors and compressor if required. Topping of refrigerant whenever required. Rectification of leak if any and testing the system with nitrogen pressure and re-commissioning after vaccumization, replacement of insulation sleeves on Copper tubings.\nIII) Other Works\nValidation Frequency : 2 tests per year\nBreakdown attendance: Within 24 hrs.BI01010001010000000000000515BI01000011131Nos

AI Tender Summary

OUR REF NO 23241079
AUTHORITY Government Departments
TENDER VALUE 4 Lakhs
LAST DATE 22-01-2020
Authority
Authority Name Drugs Control Department
Work Description Comprehensive Annual Maintenance Contract For The Works Given As Item Description At Drugs Testing Laboratory , Thiruvananthapuram During The Financial Year 2020-21 , Microbiology Lab - Camc , I ) Clean Room Validation As Per Grade A , B , C & D ( I ) Air Flow Velocity ( Ii ) Air Changers Per Hour ( Iii ) Filter Integrity Test ( Iv ) Differential Pressure ( V ) Recovery Time ( Vi ) Room Temperature & Humidity ( Vii ) Particle CountIi ) Maintenance , Servicing & Overhauling Works Of Hvac SystemA ) Air Handling Units - 3 Nos ( 8 . 5 Ton X 2 Nos . & 5 . 5 Ton X 1 No . ) ( I ) Flushing And Cleaning Of Finned Surface & Dx Tubes Of Cooling Coils ( Ii ) Checking & Replacement Of Faulty Fan Bearing ( Iii ) Checking & Replacement Of Faulty Motor Bearing ( Iv ) Checking Of Belt Allignment And Tension & Mounting Bolts . ( V ) Cleaning Of Filters , Replacement Of Defective Belts , Pulleys , Blowers , Shafts , Bearings Of Ahus Whenever Found Defective . B ) Electrical Panels And Wiring ( I ) Checking And Servicing Of Contactors , Capacitors , Overloads , Mccbs And Fuses , Tightening Of Wiring Connections And Replacement Of Faulty Parts If Required . ( Ii ) Checking Of Wiring Insulations & Motor Winding ( Iii ) Checking Of Earthing . C ) Outdoor Units - 3 Nos ( 8 . 5 Ton X 2 Nos . & 5 . 5 Ton X 1 No . ) Flushing & Cleaning Of Finned Surface Of Condenser , General Change Of Compressor Oil If Required , Greasing Of Bearing And Oiling Wherever Required , Replacement Of Motors And Compressor If Required . Topping Of Refrigerant Whenever Required . Rectification Of Leak If Any And Testing The System With Nitrogen Pressure And Re-Commissioning After Vaccumization , Replacement Of Insulation Sleeves On Copper Tubings . Iii ) Other WorksValidation Frequency : 2 Tests Per YearBreakdown Attendance: Within 24 Hrs .
Basic Detail
Tender No EP-04/2019-2020/DTL/SN
Bidding Type Tender
Location
City Vanchiyoor
State Kerala
Key Dates
Publish Date 14 Jan 2020
Submission Date 22 Jan 2020
Open Date 25 Jan 2020
Finance
Tender Value 4 Lakhs
Tender Fee 800
EMD 4000
Exemption Not Available
Document List
F8D3B1CC-504D-4325-B371-42E543953999.html
Tendernotice_1.pdf
BOQ_467181.xls
Agreement.pdf
eTenderingCoditions.pdf
generalconditions.pdf
FormofTender.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 14, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 22, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 25, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

F8D3B1CC-504D-4325-B371-42E543953999.html

pdf

Tendernotice_1.pdf

xls

BOQ_467181.xls

pdf

Agreement.pdf

pdf

eTenderingCoditions.pdf

pdf

generalconditions.pdf

pdf

FormofTender.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders