Comprehensive Annual Maintenance Contract For The Works Given As Item Description At Drugs Testing Laboratory , Thiruvananthapuram During The Financial Year 2020-21, Vanchiyoor-Kerala

Drugs Control Department has published Comprehensive Annual Maintenance Contract For The Works Given As Item Description At Drugs Testing Laboratory , Thiruvananthapuram During The Financial Year 2020-21. Submission Date for this Tender is 22-01-2020. Bolts Tenders in Vanchiyoor Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

23241079
Comprehensive Annual Maintenance Contract For The Works Given As Item Description At Drugs Testing Laboratory , Thiruvananthapuram During The Financial Year 2020-21
Open Tender
Indian
Kerala
Vanchiyoor
22-01-2020

Tender Details

Comprehensive Annual Maintenance Contract For The Works Given As Item Description At Drugs Testing Laboratory , Thiruvananthapuram During The Financial Year 2020-21 , Microbiology Lab - Camc , I ) Clean Room Validation As Per Grade A , B , C & D ( I ) Air Flow Velocity ( Ii ) Air Changers Per Hour ( Iii ) Filter Integrity Test ( Iv ) Differential Pressure ( V ) Recovery Time ( Vi ) Room Temperature & Humidity ( Vii ) Particle CountIi ) Maintenance , Servicing & Overhauling Works Of Hvac SystemA ) Air Handling Units - 3 Nos ( 8 . 5 Ton X 2 Nos . & 5 . 5 Ton X 1 No . ) ( I ) Flushing And Cleaning Of Finned Surface & Dx Tubes Of Cooling Coils ( Ii ) Checking & Replacement Of Faulty Fan Bearing ( Iii ) Checking & Replacement Of Faulty Motor Bearing ( Iv ) Checking Of Belt Allignment And Tension & Mounting Bolts . ( V ) Cleaning Of Filters , Replacement Of Defective Belts , Pulleys , Blowers , Shafts , Bearings Of Ahus Whenever Found Defective . B ) Electrical Panels And Wiring ( I ) Checking And Servicing Of Contactors , Capacitors , Overloads , Mccbs And Fuses , Tightening Of Wiring Connections And Replacement Of Faulty Parts If Required . ( Ii ) Checking Of Wiring Insulations & Motor Winding ( Iii ) Checking Of Earthing . C ) Outdoor Units - 3 Nos ( 8 . 5 Ton X 2 Nos . & 5 . 5 Ton X 1 No . ) Flushing & Cleaning Of Finned Surface Of Condenser , General Change Of Compressor Oil If Required , Greasing Of Bearing And Oiling Wherever Required , Replacement Of Motors And Compressor If Required . Topping Of Refrigerant Whenever Required . Rectification Of Leak If Any And Testing The System With Nitrogen Pressure And Re-Commissioning After Vaccumization , Replacement Of Insulation Sleeves On Copper Tubings . Iii ) Other WorksValidation Frequency : 2 Tests Per YearBreakdown Attendance: Within 24 Hrs .

Key Value

Document Fees
INR 800 /-
EMD
INR 4000.0 /-
Tender Value
INR 4 Lakhs /-

BOQ Items

Name of Work: Entering for Comprehensive Annual Maintenance Contract for the Works given as Item Description at DTL, Thiruvananthapuram during the Financial Year 2020-21
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Microbiology Lab - CAMC BI01010001010000000000000515BI0100001112
2 1.01 I) Clean Room Validation as per grade A, B, C & D\n(i) Air Flow Velocity (ii) Air Changers per Hour\n(iii) Filter Integrity Test (iv) Differential Pressure\n(v) Recovery Time (vi) Room Temperature & Humidity\n(vii) Particle Count\nII) Maintenance, Servicing & Overhauling works of HVAC System\nA) Air Handling Units - 3 Nos (8.5 Ton x 2 Nos. & 5.5 Ton x 1 No.)\n(i) Flushing and Cleaning of Finned Surface & DX Tubes of Cooling Coils\n(ii) Checking & Replacement of faulty Fan Bearing\n(iii) Checking & Replacement of faulty Motor Bearing\n(iv) Checking of Belt Allignment and Tension & Mounting Bolts.\n(v) Cleaning of Filters, Replacement of Defective Belts, Pulleys, Blowers, Shafts, Bearings of AHUs whenever found defective.\nB) Electrical Panels and Wiring\n(i) Checking and Servicing of Contactors, Capacitors, Overloads, MCCBs and Fuses, Tightening of wiring connections and Replacement of faulty parts if required.\n(ii) Checking of Wiring Insulations & Motor Winding\n(iii) Checking of Earthing.\nC) Outdoor Units - 3 Nos (8.5 Ton x 2 Nos. & 5.5 Ton x 1 No.)\nFlushing & Cleaning of finned surface of condenser, General Change of compressor oil if required, greasing of bearing and oiling wherever required, replacement of motors and compressor if required. Topping of refrigerant whenever required. Rectification of leak if any and testing the system with nitrogen pressure and re-commissioning after vaccumization, replacement of insulation sleeves on Copper tubings.\nIII) Other Works\nValidation Frequency : 2 tests per year\nBreakdown attendance: Within 24 hrs. BI01010001010000000000000515BI0100001113 1 Nos