}

Repair/Maintenance Of Street Lights On Swan Neck Pole And High Mast Lights And Other Connected Items At Jne And Chnc Area Under Ge Utilities Udhampur, UDHAMPUR-Jammu And Kashmir

Military Engineer Services-MES has published Repair/Maintenance Of Street Lights On Swan Neck Pole And High Mast Lights And Other Connected Items At Jne And Chnc Area Under Ge Utilities Udhampur. Submission Date for this Tender is 12-02-2020. Spare Part Tenders in UDHAMPUR Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

23227277
Corrigendum : Repair/Maintenance Of Street Lights On Swan Neck Pole And High Mast Lights And Other Connected Items At Jne And Chnc Area Under Ge Utilities Udhampur
Open Tender
Indian
Jammu And Kashmir
UDHAMPUR
12-02-2020

Tender Details

Repair / Maintenance Of Street Lights On Swan Neck Pole And High Mast Lights And Other Connected Items At Jne And Chnc Area Under Ge Utilities Udhampur - 1 Taking Down Carefully Unserviceable Of 70 Watt Street Liight / Security Light / High Mast Light Fitting From Pole / Structure And Repair / Replacement Of Worn Out Parts Such As Ballast, Lamp, Starter, Ignitor Etc, Cleaning Of Fittings, Cover, Copper Wire, Clamps, Nuts And Bolts, Mounting Bracket And Re Assembling The Same After Repair, Testing And Refixing In Pole / Other Location Including Provision Of Necessery T & P Like Ladder / Boom Vehicle, Tools Ets As Required For Taking Down And Refixing Of Street Light Complete All As Specified And Directed By Engr-In-Charge. Nnote: Replacement Of Defective Spare Parts Of Fitting ( To Make Functional ) Will Be Measured And Paid Separately As Supply Only. However, Cost Of Replacement Screws, Nuts, Bolts, And Cleaning Of Fittings Shall Be Deemed To Be Included In Quoted Rate. 2 Description All As Per Serial Item No 01 Here-In-Before But Hpsv / Mh Light Fittings 150 Watt Street Light Fitting. 3 Description All As Per Serial Item No 01 Here-In-Before But Hpsv / Mh Light Fittings 250 Watt Street Light Fitting. 4 Description All As Per Serial Item No 01 Here-In-Before But Hpsv / Mh Light Fittings 400 Watt Street Light Fitting. 5 Description All As Per Serial Item No 01 Here-In-Before But Hpsv / Mh Light Fittings 250 To 400 Watt Double Ended Lamp Street Light Fitting. 6 Supply Only Copper Wound Ballast Suitable For 70 Watt Hpsv / Mh Light Fitting Complete All As Specified And Directed By Engr-In-Charge. Nmake: Bajaj / Crompton / Philips 7 Description All As Per Serial Item No 06 Here-In-Before But Copper Wound Ballast Suitable For 150 Watt Hpsv / Mh Light Fitting. 8 Description All As Per Serial Item No 06 Here-In-Before But Copper Wound Ballast Suitable For 250 Watt Hpsv / Mh Light Fitting. 9 Description All As Per Serial Item No 06 Here-In-Before But Copper Wound Ballast Suitable For 400 Watt Hpsv / Mh Light Fitting. 10 Description All As Per Serial Item No 06 Here-In-Before But Lamp Suitable For 70 Watt Mh Light Fitting. 11 Description All As Per Serial Item No 06 Here-In-Before But Lamp Suitable For 150 Watt Mh Light Fitting. 12 Description All As Per Serial Item No 06 Here-In-Before But Lamp Suitable For 250 Watt Mh Light Fitting. 13 Description All As Per Serial Item No 06 Here-In-Before But Lamp Suitable For 400 Watt Mh Light Fitting. 14 Description All As Per Serial Item No 06 Here-In-Before But Lamp Suitable For 70 Watt Hpsv Light Fitting. 15 Description All As Per Serial Item No 06 Here-In-Before But Lamp Suitable For 150 Watt Hpsv Light Fitting. 16 Description All As Per Serial Item No 06 Here-In-Before But Lamp Suitable For 250 Watt Hpsv Light Fitting. 17 Description All As Per Serial Item No 06 Here-In-Before But Lamp Suitable For 400 Watt Hpsv Light Fitting. 18 Description All As Per Serial Item No 06 Here-In-Before But Electronic Igniters Suitable For 70 / 150 / 250 / 400 Watt. 19 Description All As Per Serial Item No 06 Here-In-Before But Capacitor 10 Mfd / 20 Mfd / 33 Mfd For Hpsv, Mv, Mh Lamp Fittings. 20 Taking Down Existing Old Pcc / Steel Poles Complete All As Specified And Directed By Engr-In-Charge. Nnote: Damaged Poles Shall Be Removed From The Site As Per Direction Of Engr-In-Charge. 21 Dismantling / Taking Down Of Old Unsv Acsr Conductor Of Any Size For Lt Oh Line, Earth Wire & Cradles Complete All As Specified And Directed By Engr-In-Charge. 22 Taking Down Existing Old Cross Arms Of Ms Channel Or Angle Sections Etc Complete All As Specified And Directed By Engr-In-Charge. 23 Dismantling Of Old Insulators Pin / Shackle Complete And Keeping Aside For Removal Complete All As Specified And Directed By Engr-In-Charge. 24 S&F In Replacement Erecting Steel Tubular Swaged Poles Erected To Truly Vertical Or Planted As Strut Complete With 6Mm Thick Mild Steel Base Plate ( 300Mmx300mm ) , Welded To Pole, Finial Taper Plug, Bolts, Nuts, And Screws Poles Made Out Of Erw Ms Tubing Conforming To Is-2713 Part-Ii Type 410 Sp-31, 9Mtr Long Including Drilling Of Holes Of Required Size For Fixing Of Cross Arms, Painting The Exposed Surfaces Of Pole With Two Coats Of Aluminum Paint Over A Coat Of Red Oxide Zinc Chrome Primer And With Two Coats Of Black Bitumenous Paint Internally And Portion Embedded In Concrete, Making Five Black & White Bands At Lower Portion Of Pole Each 300Mm Wide Alternately Upto The Height And Marking Pole No. With Black Paint At Suitable Height Including Making Two Nos Holes Of Suitable Size In Steel Tubular Pole By Gas Welding For Passing Pvc Cable Connection From Junction Box To Security Lights Through Pole Where Junction Box To Be Fitted In Pole Complete All As Specified And Directed By Engr-In-Charge. Nnote: Excavation And Earth Work, Pcc In Foundation Shall Be Measured And Paid For Separately. 25 Supply, Laying, Jointing In Replacement & Testing 1100 Volts Grade Heavy Duty Cable Pvc Tape Pvc Sheathed 2.5 Sqmm Aluminium Solid Conductor 2 Core Nominal Cross Section Laid In Trenches / Fixed To Walls / Passing Under The Roads In Existing Pipes Etc Including Takind Down Old Unsv Cable Complete All As Specified And Directed By Engr-In-Charge. 26 S&F In Replacement Modular Box Of Size 333 X 233 X 120 Mm Made Of Frp Inpact Resistance Plastic & Heat Resistant Materials Including Mcb Sp 6 A, Connector Terminal Block 4 Pole 16 A Capacity And Fixing To The Street Light Or Post Top Light Pole With Suitable Sizes Of Clamps, Nuts And Bolts Complete All As Specified And Directed By Engr-In-Charge. 27 S&F In Replacement Bracket For Street Light Fittings Made Out Of 40 Mm Dia Gi Pipe Of Medium Grade 1.5 Mtr Long Each Bent To Required Shape & Size And Fixed To Pole With And Including Flat Iron Clamps 02 Nos Made Out Of 32 X 6 Mm Flat Iron Including Gi Nuts, Bolts And Washers And Painting Of Clamps And Street Light Brackets With Two Coat Of Aluminium Paint Over A Coat Of Red Oxide Primer Complete All As Specified And Directed By Engr-In-Charge. 28 S&F In Replacement 150 Watt Led Flood Light With Pressure Die Cast Aluminium Housing & Toughened Glass With Ip-66 Degree Protection, Individual Leds Must Have Peanut Lenses For Better Throw Across & Along The Road With Luminarie Efficacy Of Greater Than 110 Lumen / Watt ( Minimum Lumen Output Of Luminarie Should Be 16500 Lumens ) Color Rendering ( Cri ) Of > 75 And Co-Related Color Temperature ( Cct ) Of 5700K ( + 500K ) , The Luminarie Should Have 5 Kv Surge Protection, Pf > 0.95, And Total Harmonic Distortion Of Thd < 10% ( Make Of Led Shall Be Cree / Nichia / Osram ) , Voltage Range Of 140-280V Should Be Provided. Luminarie Should Have Top Maintainable Driver Compartment For Easy Access To Driver During Maintenance. The Driver Used Must Be A Constant Current Driver With Efficiency Of > 85%. The Manufactures Logo Must Be Embossed / Engraved In The Housing Of The Luminarie. Manufactures To Provide Lm80 Test Report From Source Manufacturer And Should Have Adequate Testing Facilities Approved By Ministry Of Science ( Govt Of India ) To Provide Lm 79 Report Complete All As Specified And Directed By Engr-In-Charge. 29 S&F In Replacement 90 Watt Led Street Light With Pressure Die Cast Aluminium Housing & Toughened Glass With Ip-66 Degree Protection, Individual Leds Must Have Peanut Lenses For Better Throw Across & Along The Road With Luminarie Efficacy Of Greater Than 100 Lumen / Watt ( Minimum Lumen Output Of Luminarie Should Be 9000 Lumens ) Color Rendering ( Cri ) Of > 75 And Co-Related Color Temperature ( Cct ) Of 5700K ( + 500K ) , The Luminarie Should Have 5 Kv Surge Protection, Pf > 0.95, And Total Harmonic Distortion Of Thd < 10% ( Make Of Led Shall Be Cree / Nichia / Osram ) , Voltage Range Of 140-280V Should Be Provided. Luminarie Should Have Top Maintainable Driver Compartment For Easy Access To Driver During Maintenance. The Driver Used Must Be A Constant Current Driver With Efficiency Of > 85%. The Manufactures Logo Must Be Embossed / Engraved In The Housing Of The Luminarie. Manufactures To Provide Lm80 Test Report From Source Manufacturer And Should Have Adequate Testing Facilities Approved By Ministry Of Science ( Govt Of India ) To Provide Lm 79 Report Complete All As Specified And Directed By Engr-In-Charge. 30 S&F In Replacement 60 Watt Led Street Light With Pressure Die Cast Aluminium Housing & Toughened Glass With Ip-66 Degree Protection, Individual Leds Must Have Peanut Lenses For Better Throw Across & Along The Road With Luminarie Efficacy Of Greater Than 100 Lumen / Watt ( Minimum Lumen Output Of Luminarie Should Be 6000 Lumens ) Color Rendering ( Cri ) Of > 75 And Co-Related Color Temperature ( Cct ) Of 5700K ( + 500K ) , The Luminarie Should Have 5 Kv Surge Protection, Pf > 0.95, And Total Harmonic Distortion Of Thd < 10% ( Make Of Led Shall Be Cree / Nichia / Osram ) , Voltage Range Of 140-280V Should Be Provided. Luminarie Should Have Top Maintainable Driver Compartment For Easy Access To Driver During Maintenance. The Driver Used Must Be A Constant Current Driver With Efficiency Of > 85%. The Manufactures Logo Must Be Embossed / Engraved In The Housing Of The Luminarie. Manufactures To Provide Lm80 Test Report From Source Manufacturer And Should Have Adequate Testing Facilities Approved By Ministry Of Science ( Govt Of India ) To Provide Lm 79 Report Complete All As Specified And Directed By Engr-In-Charge. 31 Excavation In Trenches In Any Type Of Soil Not Exceeding 1.5 Meter Wide And Not Exceeding 1.5M In Depth For Laying Of Cables And Getting Out Of Excavated Material Complete All As Specified And Directed By Engr-In-Charge. 32 Description All As Per Serial Item No 31 Here-In-Before But Depth Exceeding 1.5 Meter And Not Exceeding 3 Meter Complete All As Specified And Directed By Engr-In-Charge. 33 Returning, Filling In, Including Spreading, Leveling, Watering And Well Ramming In Layers Not Exceeding 25Cm Thick Each, Excavated Soil In Trenches After The Cables Have Been Laid And Tested Complete All As Specified And Directed By Engr-In-Charge. 34 Removing Excavated Soil To A Distance Not Exceeding 50 Meter And Depositing Where Directed At A Level Not Exceeding 1.50 Meter Above The Starting Point Complete All As Specified And Directed By Engr-In-Charge. 35 M&L For Dry Sand Cushioning To Underground Cables Provided With A Layer Of Sand 8 Cm Thick Before Laying The Cable And 15 Cm Thick After Laying And Stretching The Cable, Sand Cushion Shall Be Punned To 18 Cm Thickness Complete All As Specified And Directed By Engr-In-Charge. Nnote: Only Punned Thickness Shall Be Measured And Paid. 36 Supply And Laying Burnt Brick Sub Class B For Cable Protection Laid Adjacent To Each Other Perpendicular To The Direction Of Cable In Trenches Complete All As Specified And Directed By Engr-In-Charge. 37 M&L For Cement Concreate 1:3:6 Type C-1 ( Using 20 Mm Graded Stone Aggregate ) As In Coping Etc Including Necessary Form Work Complete All As Specified And Directed By Engr-In-Charge. 38 M&L For Pcc 1:4:8 Type D-2 ( Using 40 Mm Graded Stone Aggregate ) In Foundation, Mass Concrate As In Foundation Of Pole & Stay Etc Complete All As Specified And Directed By Engr-In-Charge. 39 Taking Down The Unserviceable Lt Cable Of Any Size From Tranches / Walls / Floor Etc Complete All As Specified And Directed By Engr-In-Charge. 40 Supply, Laying, Jointing & Testing Xlpe Insulated, Pvc Bedded Galvanised Steel Strip Or Wire Armoured Electric Power Cable Heavy Duty With Stranded Aluminium Conductor 1100 Volts Grade Cross Sectional Area 10 Sqmm 2 Core Laid In Trenches Or Passing Through Pipe Or Fixed On Poles Complete All As Specified And Directed By Engr-In-Charge. 41 Description All As Per Serial Item No 40 Here-In-Before But Of Size 16 Sqmm 4 Core 42 Description All As Per Serial Item No 40 Here-In-Before But Of Size 25 Sqmm 4 Core. 43 Description All As Per Serial Item No 40 Here-In-Before But Of Size 35 Sqmm 3.5 Core. 44 Description All As Per Serial Item No 40 Here-In-Before But Of Size 50 Sqmm 3.5 Core. 45 Supply And Laying In Replacement Galvanised Iron Steel Tubes, Isi Marked Light Grade Of Size 40 Mm Bore For Cable Protection Along The Poles Under Road Under Drains, Laid In Trenches / Fixed On Walls / Poles With Suitable Clamps Bolts Nuts Etc Including Taking Down Of Old Unserviceble Pipe Complete All As Specified And Directed By Engr-In-Charge. 46 Supply And Laying In Replacement Galvanised Iron Steel Tubes, Isi Marked Light Grade Of Size 80 Mm Bore For Cable Protection Along The Poles Under Road Under Drains, Laid In Trenches / Fixed On Walls / Poles With Suitable Clamps Bolts Nuts Etc Including Taking Down Of Old Unserviceble Pipe Complete All As Specified And Directed By Engr-In-Charge. N 47 S&F In Replacement Aluminium Conductor Steel Reinforced ( Acsr ) Of Any Size On Poles, Stretched On Lt Poles Without Any Kink And Bends Of Various Sizes Complete Including Fixing To Insulator With Aluminium Binding Wire Complete All As Specified And Directed By Engr-In-Charge. 48 S&F In Replacement Ms Channel / Angle Iron / Flat Iron Of Required Size And Bend To Shape As Cross Arms, Bracing And Support Including, Ms Clamps, Back Plates With Bolts, Nuts, And Washers Drilled For Insulators Including Painting Two Coats Of Synthetic Enemel Paint ( Aluminium Shade ) Over A Coat Of Red Oxide Primer Complete All As Specified And Directed By Engr-In-Charge. 49 Cleaning The Existing Exposed Surfaces Of Steel Tubular Pole Of 9.0 Mtr Long Including Cross Arms, Brackets, Clamps Etc And Painting With Two Coats Of Synthetic Enamel Paint ( Aluminium Shade ) Marking Five Black & White Bands At Lower Portion Of Pole, Each 300 Mm Wide Alternately And Marking Pole No. With Yellow Paint On Black Base At Suitable Height Complete All As Specified And Directed By Engr-In-Charge. 50 S&F In Replacement Power Contactor 3 Phase 415 Volts, 40 Amps, Coil Voltage Of Rating 240 Volts Including Taking Down Old Unserviceable Power Contactor Complete All As Specified And Directed By Engr-In-Charge. 51 S&F In Replacement Power Contactor 4 Pole 240 Volts, 32 Amps, Coil Voltage Of Rating 240 Volts Including Taking Down Old Unserviceable Power Contactor Complete All As Specified And Directed By Engr-In-Charge. 52 Taking Down The Existing Led Street Light Fittings Of Any Type And Make Checking The Serviceability Complete All As Specified And Directed By Engr-In-Charge. 53 S&F In Replacement Driver For Led Energy Saving & Enviornment Area Light Fitting > 90 Watts Security Light With Active Power Factor Correction ( Apfc ) Electronic Driver. Led Driver 90 Watt With Operating Voltage Between 100-270 V Of Existing Specifications & Make Complete All As Specified And Directed By Engr-In-Charge. 54 S&F In Replacement Driver For Led Energy Saving & Enviornment Area Light Fitting > 48 Watts Security Light With Active Power Factor Correction ( Apfc ) Electronic Driver. Led Driver 48 Watt With Operating Voltage Between 100-270 V Of Existing Specifications & Make Complete All As Specified And Directed By Engr-In-Charge. 55 S&F In Replacement Automatic Street Light Switch Using Infrared Sensor Based Nature Switch For Automatic Switching Of Street Lights. Nature Switch Operation Should Be Based On Natural Light Lux* Level. Required Illuminance Level For Switching On Is = 30 Lux And For Switching Off = 10 Lux. The Sensor Should Also Have Part Night Operation Facility Of Min. 4 Hrs. To Max. 12 Hrs. The Sensor Along With Suitable Power Contactor, Incoming- Outgoing Mcbs And Auto-Manual ( Sensor By-Pass ) Selection Option Should Be Enclosed In A Pole / Wall Mountable Enclosure Made Of Rust Proof, Electric Shock Proof, Termite Proof And Fr Grade Smc Junction Box Conforming To Ip54. The Circuit Should Be Suitable Enough To Take Single-Phase Load Of 8Kw With Contactor & Incoming-Outgoing Mcb Rating Of 63 Amps & Circuit Wiring: Min. 16 Sq.Mm Complete All As Specified And Directed By Engr-In-Charge. Nmake: Kakatiya Energy Systems, Model No Swadeep-02Ec8kw1p Or Equivalent In Bajaj / Healer. 56 S&F In Replacement Automatic Street Light Switch Using Infrared Sensor Based Nature Switch For Automatic Switching Of Street Lights. Nature Switch Operation Should Be Based On Natural Light Lux* Level. Required Illuminance Level For Switching On Is = 30 Lux And For Switching Off = 10 Lux. The Sensor Should Also Have Part Night Operation Facility Of Min. 4 Hrs. To Max. 12 Hrs. Nthe Sensor Along With Suitable Power Contactors, Incoming- Outgoing Mcbs And Auto-Manual ( Sensor By-Pass ) Selection Option Should Be Enclosed In A Pole / Wall Mountable Enclosure Made Of Rust Proof, Electric Shock Proof, Termite Proof And Fr Grade Smc Junction Box Conforming To Ip54. Nthe Circuit Should Be Suitable Enough To Take 12Kw Load Equally Distributed Over 3-Phase With Contactors & Incoming-Outgoing Mcb Rating Of 40 Amps & Circuit Wiring: Min. 10 Sq.Mm Complete All As Specified And Directed By Engr-In-Charge. Nmake Of Nature Switch: Kakatiya Energy Systems, Model No Swadeep-02Ec12kw3p Or Equivalent In Bajaj / Healer. 57 M&L For Earthing Complete With Galvanized Steel Earth Plate Electrode 600 Mm X 600Mm X 6.0Mm Thick Buried Directly In Ground ( Earth Pit Not Less Than 2.25 Mtr Below Normal Ground Level ) With Top Edge Plate Not Less Than 1.5 Metre Below Normal Ground Level Connected To Galvanized Earth Wire Of Size 4 Mm Dia As Earthing Lead By Means Of Bolts, Nuts, Chuck Nuts And Washers Of Galvanized Iron Earth Lead Including Pcc Pit In Pcc 1:2:4 Type B-1, Rcc Cover Made Out Of Cement Concrete 1:2:4 Type B-1 ( Using 20 Mm Graded Crushed Stone Aggregate ) Reinforced With Tmt Steel Bars 8 Mm Dia @150 Mm C / C Both Ways With Suitable Handle And Angle Iron 40X40x5mm Frame, Gi Medium Grade Watering Pipe 20Mm Bore And Funnel With Wire Mesh Light Grade Protection Pipe 40Mm Bore Up To Main Board Complete As Shown On Electrical Plate No 3 Of Mes Sch 2009 ( Part-I ) And Testing On Completion Complete All As Specified And Directed By Engr-In-Charge. Nnote: On Testing After Completion Of Earthing, If Desired Earth Resistance Is Not Obtained, The Earthing Will Be Re-Done By The Contractor At His Own Risk & Cost To The Entire Satisfaction Of Engineer-In-Charge. 58 S&F In Replacement Switch Fuse Unit In Sheet Steel Enclosure Powder Coated, Weather Proof Confirming To Is 13947 ( Part 3 ) 1993 With Rewireable And Hrc Cum Rewireable Of Capacity 400 Amps Four Pole 415 Volts With Fuses Including Taking Down Old U / S Switch Fuse Unit All Complete All As Specified And Directed By Engr-In-Charge. Nmake: Haveels / Hpl / C&S

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 07-Feb-2020 REVISED DATES Date 12-02-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 49000.0 /-
Tender Value
INR 24.50 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail