80849 Provision Of Automatic Meter Reading And Billing System Phase I To Naval Govt Md Accn At Ge Haddo Port Blair, Garrison Engineer Haddo Port Blair-West Bengal

Military Engineer Services-MES has published 80849 Provision Of Automatic Meter Reading And Billing System Phase I To Naval Govt Md Accn At Ge Haddo Port Blair. Submission Date for this Tender is 05-02-2020. Accounting Software Tenders in Garrison Engineer Haddo Port Blair West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

23226100
Corrigendum : 80849 Provision Of Automatic Meter Reading And Billing System Phase I To Naval Govt Md Accn At Ge Haddo Port Blair
Open Tender
Indian
West Bengal
Garrison Engineer Haddo Port Blair
05-02-2020

Tender Details

80849 Provision Of Automatic Meter Reading And Billing System Phase I To Naval Govt Md Accn At Ge Haddo Port Blair

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 20-Jan-2020 80849 CORRIGENDUM1 Date 05-02-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 28800.0 /-
Tender Value
INR 14.40 Lakhs /-

BOQ Items

Name of Work : PROVISION OF AUTOMATIC METER READING AND BILLING SYSTEM (PHASE I) TO NAVAL GOVT MD ACCNS AT GE HADDO, PORT BLAIR
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Supply and fix static meter of class 1.0, AC Three Phase two wire, tamper proof, 415V, 50Hz, basis current 10A-60A conforming to IS-13779 and relevent IEC Standards with inbuilt low power radio frequency (LPRF) communitcation facility in 865-867 MHz in Cyantech or equivalent mesh network with default and on demand display, billing data generation facility, anti-tamper features, microprocessor and LED/LCD based circuitry , including removal of exisiting electric meter and depositing to MES Storyard.\nMake: L&T, Capital, Cynatech, HPL, Elmeasure India Pvt Ltd., 10 Each
2 2 Supply and fix static meter of class 1.0, AC Single Phase two wire, tamper proof, 240V, 50Hz, basis current 10A-60A conforming to IS-13779 and relevent IEC Standards with inbuilt low power radio frequency (LPRF) communitcation facility in 865-867 MHz in Cyantech or equivalent mesh network with default and on demand display, billing data generation facility, anti-tamper features, microprocessor and LED/LCD based circuitry, including removal of exisiting electric meter and depositing to MES Storyard.\nMake: L&T, Capital, Cynatech, HPL, Elmeasure India Pvt Ltd., 110 Each
3 3 Supply and fix Data Concentrator Unit (DCU) compatible for remote Automatic meter reading (AMR) solution and capable of communication with the static energy meter in the corresponding frequency band in 865-867 MHz in Cyantech or equivalent Mesh network and with the data server through GPRS and shall have minimum data transfer rate of 9600 Byts/Sec, internal memory to store data of 50 modules for 6 month period and shall be based on LPRF communication Mesh network within 50 meter range Make: L&T, Capital, Cynatech, HPL, Elmeasure India Pvt Ltd., 12 Each
4 4 Supply and fix Repeater unit with inbuilt low power radio frequency (LPRF) communication facility in 865-867 MHz in Cyantech or equivalent Mesh network with inbuilt AC power supply.\nMake: L&T, Capital, Cynatech, HPL, Elmeasure India Pvt Ltd., 10 Each
5 5 Supplying, Fixing, Commissioning and testing of configuration of Cloud Hosted multi user web based software with following modules:\n(i) Meter Data Management Module: The meter data management module would be responsible for collecting the data from the concentrator and make the data available to the billing system. The system would support offline meter data entry. The meter data management system would capture and provide the follwing data:\n(a) 30min instantaneous data from all the meters for seven parameters- Cumulative Energy, Cumulative Apparent Energy, Power, Current, Voltage, Power factor and Frequency.\n(b) Monthly and quarterly billing survey data for cumulative energy and max demand\n(Contd to next page.....)\n 120 Each
6 5.1 (Contd from previous page....)\n(ii) Billing Module: The billing module would collectg the data from the meter data management module, calculate billing determinant and make energy data/ billing data available to admin and end users.\n(iii) Occupation and vacation Module: The System would support occupation/ vacation based on the unit categories. The system would support automatic data capture on occupation and vacation events.\n(iv) Customer portal: The system would include a customer portal for the resident/ occupant to log in and view their own energy / billing data.\n(v) Energy Accounting Module: The system would include features of energy accounting. the system would be able to account for total energy bloack wise, facility wise and would also allow calcyulations of unaccounted energy in case total energy meter is also available.\n(vi) Communication module: The system would provide conmmunication of energy data and bills via print, email and sms methods\n(vii) Meter Master Data : The system would support meter data repository. The system wouls support meter replacment process.\n(viii) Excel Export : The system would support export of metering and billing data in excel format\nMake : L&T , Innologix, Capital, Elmeasure India Pvt Ltd.,
7 6 Hosting, AMC and GPRS charges for four years after one year from project completion ( project includes one year warranty) 48 Per Month