Annual Repairs And Maintenance Of Electrical Installations At Bsc , Hanuman Junction For The Year 2019-20 . Rewiring Of G . No . 1 To G . No . 6 And Improvement Of Railway Siding Lighting With Led Fittings .
Tender Value
14.06 Lakhs
Estimated cost
Bid Submission
16 Jan 2020
0 days left
EMD
28140
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Hanuman Junction → Andhra Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Annual Repairs And Maintenance Of Electrical Installations At Bsc , Hanuman Junction For The Year 2019-20 . Rewiring Of G . No . 1 To G . No . 6 And Improvement Of Railway Siding Lighting With Led Fittings .
BOQ
| Name of Work: Annual Repairs and Maintenance of Electrical Installations at BSC Hanuman Junction for the year 2019-20. S.H: Rewiring of G.No.1 to G.No. 6 and improvement of Railway Siding Lightning with LED Fittings. | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Supplying of PVC/XLPE armoured cable with aluminium conductor 650/1100V. Grade confirming to IS 7098 (part I)1988 with upto date amendments of the following size at the site of work. (make: Polycab/Universal / Havells / Gloster / Finolex etc.,) | BI01010001010000000000000515BI0100001112 | ||
| 2 | 1.01 | 4 X16 Sq.mm | BI01010001010000000000000515BI0100001113 | 70 | Mtr |
| 3 | 2 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required. | BI01010001010000000000000515BI0100001114 | ||
| 4 | 2.01 | upto 35 Sq.mm | BI01010001010000000000000515BI0100001115 | 42 | Mtr |
| 5 | 3 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required. | BI01010001010000000000000515BI0100001116 | ||
| 6 | 3.01 | upto 35 Sq.mm(Clamped with 1 mm thick saddle) | BI01010001010000000000000515BI0100001117 | 28 | Mtr |
| 7 | 4 | Supplying and fixing of light class G.l. pipe of 50 mm dia. (nominal) 3 metres length along the pole/wall for protection of under ground cable as required. | BI01010001010000000000000515BI0100001118 | 3 | Each |
| 8 | 5 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc. as required | BI01010001010000000000000515BI0100001119 | ||
| 9 | 5.01 | 100 mm dia | BI01010001010000000000000515BI0100001120 | 24 | Mtr |
| 10 | 6 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. | BI01010001010000000000000515BI0100001121 | ||
| 11 | 6.01 | 20 mm | BI01010001010000000000000515BI0100001122 | 40 | Mtr |
| 12 | 7 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. | BI01010001010000000000000515BI0100001123 | ||
| 13 | 7.01 | 2 x 1.5 sq. mm | BI01010001010000000000000515BI0100001124 | 4474 | Mtr |
| 14 | 7.02 | 4 x 1.5 sq. mm | BI01010001010000000000000515BI0100001125 | 708 | Mtr |
| 15 | 7.03 | 6 x 1.5 sq. mm | BI01010001010000000000000515BI0100001126 | 192 | Mtr |
| 16 | 7.04 | 3 x 2.5 sq. mm | BI01010001010000000000000515BI0100001127 | 1362 | Mtr |
| 17 | 7.05 | 6 x 2.5 sq. mm | BI01010001010000000000000515BI0100001128 | 702 | Mtr |
| 18 | 7.06 | 3 x 4 sq. mm | BI01010001010000000000000515BI0100001129 | 1290 | Mtr |
| 19 | 8 | Supplying and fixing following way, horizontal type Single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) | BI01010001010000000000000515BI0100001130 | ||
| 20 | 8.01 | 12 way double door | BI01010001010000000000000515BI0100001131 | 9 | Each |
| 21 | 9 | Supplying and fixing following way, horizontal type Triple pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) | BI01010001010000000000000515BI0100001132 | ||
| 22 | 9.01 | 4 way (4+12),Double door | BI01010001010000000000000515BI0100001133 | 2 | Each |
| 23 | 9.02 | 8 way (4+24),Double door | BI01010001010000000000000515BI0100001134 | 1 | Each |
| 24 | 10 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \"C\" curve DP MCB complete with connections, testing and commissioning etc. as required | BI01010001010000000000000515BI0100001135 | 10 | Each |
| 25 | 11 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. | BI01010001010000000000000515BI0100001136 | ||
| 26 | 11.01 | Single pole | BI01010001010000000000000515BI0100001137 | 54 | Each |
| 27 | 11.02 | Single pole and neutral | BI01010001010000000000000515BI0100001138 | 17 | Each |
| 28 | 11.03 | Triple pole and neutral | BI01010001010000000000000515BI0100001139 | 5 | Each |
| 29 | 12 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. | BI01010001010000000000000515BI0100001140 | ||
| 30 | 12.01 | 63 A | BI01010001010000000000000515BI0100001141 | 1 | Each |
| 31 | 13 | Providing and fixing of 100A/415V TPN Switch Disconnector fuse unit on surface of existing panel board including drilling holes , making connections, etc. as required(make :Standard Cat No:ISFCTW4100 or Equivalent) | BI01010001010000000000000515BI0100001142 | 1 | Each |
| 32 | 14 | Supplying and fixing following piano type switch/socket on the existing switch box/ cover including connections etc. as required. | BI01010001010000000000000515BI0100001143 | ||
| 33 | 14.01 | 5/6 amps switch | BI01010001010000000000000515BI0100001144 | 62 | Each |
| 34 | 15 | Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. | BI01010001010000000000000515BI0100001145 | ||
| 35 | 15.01 | 5/6 amps switch | BI01010001010000000000000515BI0100001146 | 24 | Each |
| 36 | 15.02 | 3 pin 5/6 amps socket outlet | BI01010001010000000000000515BI0100001147 | 6 | Each |
| 37 | 16 | Supplying and fixing following size/ modules, GI box alongwith\nmodular base & cover plate for modular switches in recess etc.\nas required. | BI01010001010000000000000515BI0100001148 | ||
| 38 | 16.01 | 8 Module (125mmX125mm) | BI01010001010000000000000515BI0100001149 | 6 | Each |
| 39 | 17 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. \n\n\n\n | BI01010001010000000000000515BI0100001150 | 6 | Each |
| 40 | 18 | Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. | BI01010001010000000000000515BI0100001151 | ||
| 41 | 18.01 | 4 X 16 Sq.mm | BI01010001010000000000000515BI0100001152 | 3 | Each |
| 42 | 19 | Supplying, installation, testing and commissioning of 20W LED T8 tubelight with PC body along with surface/Suspended water proof industrial Luminiare with Poly carbonate housing and diffuser suitable for single T8 LED tube and fixing on wall/truss by using necessary clamps and also dismantling the existing fitting.(Similar to CG make 20 W Retro LED T8(PC) cat no: LT8-20-865-2 and batten shied catno: IPFC111LT8-16 or equivalent in Philips / Bajaj/ Havells)\n | BI01010001010000000000000515BI0100001153 | 96 | Each |
| 43 | 20 | Supplying, installation, testing and commissioning of 20W LED T8 tubelight with PC body along with industrial box type Luminiare suitable for single T8 LED tube and fixing on wall/truss by using necessary clamps and also dismantling the existing fitting.(Similar to CG make 20 W Retro LED T8(PC) cat no: LT8-20-865-2 and LED batten cat no: IGP131LT8-16 or equivalent in Philips / Bajaj/ Havells) | BI01010001010000000000000515BI0100001154 | 252 | Each |
| 44 | 21 | Supplying, installation, Testing and commissioning of 70W LED flood light,Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP65 flood light, suitable for highlighting architectural facade and general purpose lighting, with suitable clamps and nut bolts and also dismantling the existing fitting at site of work etc., as required.( Similar to Havells Make Item Decription no JETAFLAREFL70WLED757LTG or euivalent in Philips / Bajaj/ Crompton ) | BI01010001010000000000000515BI0100001155 | 20 | Each |
| 45 | 22 | Supplying and drawing of Multicore Round PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volts, conforming to IS: 694 in the existing surface/ recessed steel/ PVC conduit as required. | BI01010001010000000000000515BI0100001156 | ||
| 46 | 22.01 | 3 X 1.5 Sq.mm | BI01010001010000000000000515BI0100001157 | 120 | Mtr |
| 47 | 23 | Refixing of existing LED batten on Surface/truss with suitable clamps ,nut and bolts etc. including giving connections etc. at site of work as required. | BI01010001010000000000000515BI0100001158 | 96 | each |
| 48 | 24 | CREDIT ITEMS | BI01010001010000000000000515BI0100001159 | ||
| 49 | 24.01 | Dismantled MS conduit pipe of different sizes, DB’s, GI wire and clamps etc. | BI01010001010000000000000515BI0100001160 | 50 | KG |
| 50 | 24.02 | Dismantled Aluminium insulated wire | BI01010001010000000000000515BI0100001161 | 500 | KG |
| 51 | 24.03 | Dismantled Box type 1x40W/Street light fitting | BI01010001010000000000000515BI0100001162 | 336 | Each |
| 52 | 24.04 | Dismantled HPSV Fittings | BI01010001010000000000000515BI0100001163 | 16 | Each |
AI Tender Summary
Tender Timeline
Jan 08, 2020
11:30 IST
Tender Published
Tender notice published.
CompletedJan 16, 2020
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJan 17, 2020
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender