Special Repairs To Ht Ug Cable And Allied Works At Rupa Power House And Special Repairs/Replacement Of 11 Kv Line Conductor And Allied Work At Dahung Area Under Ge 859 Ews

Issued by Statutory Bodies & Commissions/Committees · Tenga Valley, Arunachal Pradesh
Tender Value
34 Lakhs
Estimated cost
Bid Submission
10 Feb 2020
0 days left
EMD
68000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Tenga Valley → Arunachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Special Repairs To Ht Ug Cable And Allied Works At Rupa Power House And Special Repairs/Replacement Of 11 Kv Line Conductor And Allied Work At Dahung Area Under Ge 859 Ews

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 28-Jan-2020 Change in bid opening date Date 01-Feb-2020
2 03-Feb-2020 dc Date 10-Feb-2020

BOQ

Nature of Work : SPECIAL REPAIR TO HT UG CABLE AND ALLIED WKS AT RUPA POWER HOUSE AND SPECIAL REPAIR/REPLACEMENT OF 11 KV LINE CONDUCTOR AND ALLIED WK AT DAHUNG AREA UNDER GE 859 EWS
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Disconnecting, Servicing and overhauling of 11KV vacuum circuit breaker of 630 Amp capacity including following repair/testings and ensuring smooth functioning of VCB all as directed by Engr-in -charge. Note : Parts to be replaced will be measured and paid separately as \"Supply only\" against appropriate item(s) of this schedule. However labour cost towards replacement shall be deemed to be included in this item.\n(a) Checking of HT 11 KV VCB tripping circuit, over current plus earth fault relay, master tripping relay, breaker control remote switch and tripping mechanism, Calibration of IDMT Relays and CTs cap 100 Amps (set of three) through primary and secondary injection method by using relay test kit and other required measuring equipment including resetting the trip values at the numerical relays and auxillary trip relays and ensuring for healthy triping mechanism at the site of 11KV HT VCB Panel and submitting test report.\n\n(b) Checking of isolating mechanism and Cleaning of all contacts by petroleum jelly for removing deposited carbon including greasing etc.\n\n(c) Checking metering panel for internal wiring, ammeter, volmeter and RYB indicator.\n\n(d) Checking of potential transformer by conducting ratio test/meggering for IR Values provided in VCBs 11 KV, including checking of control wiring meters and calibration for the same.3Each Job
22Supply only the following spares of crompton greaves make vacuum circuit breaker (for replacement against item in-before) :-\n\n(a) Resin cast current transformer of ratio 50/25/5A-5A dual ratio one for metering of class 1 and other for protection of 5P class suitable for 12KV voltage and rear fixing type. Make :- CG4Each
33(b) Big pinion assemble for mechanism6Each
44(c) Small pinion assemble for mechanism6Each
55(d) Closing coil 110 Volt DC4Each
66(e) Tripping coil 110 Volt DC6Each
77(f) 110V DC LED lamp10Each
88(g) Monoplast tape10Each
99(h) Spouch Insulation of incoming and outgoing8Each
1010(j) Spring charged motor as per the specification. (Type-PMRS, Supply Volt- 230 DC, 150 watt, NLRPM - 10, class- B, Make- M/s DELCO).2Each
1111(k) Vacuum interrupter 630 Amp, Make- CG6Each
1212(l) Mono block diode 25A4Each
1313(m) Trolley iron wheel4Each
1414(n) Auxilliary Switch suitable for 11 KV VCB, cap 630 Amps.4Each
1515(o) HRC fuse of rating 2 Amps.30Each
1616(p) RYB Selector Switch. Make :- Salzer/kaycee32Each
1717(q) HT digital display ammeter suitable for CT rating 30/5 & 60/5 amps. Make : CONZERN, Model No. DM 32522Each
1818(r) HT digital display voltmeter suitable for HT VCB panel 1100/100 volts (auxillary volts). Make : CONZERN, Model No. DM 32512Each
1919(s) Breaker control switch code No: Customer Specific2Each
2020(t) HT digital display ammeter suitable for CT primary current 100 Amps. Make : ALPHA4Each
2121(u) HT digital display voltmeter suitable for HT VCB panel 11 KV. Make : ALPHA.2Each
2222(v) Multifunction meter digital display type. Make :- Schneider.2Each
2323(w) Space Heater 20A, 250V AC only, Make:-Vileco.4Each
2424Excavation in trenches not exc. 1.5M wide and n.exc. 1.5M in depth in soft/loose soil including black cotton soil and getting out all as specified and directed.42.12Cum
2525Returning filling in including spreading, watering and well ramming in layers n.exc. 25 cm thick after the cable are laid.33.66Cum
2626Removal of surplus soil to a distance n. exc. 50 Mtrs and depositing where directed at a lavel n.exc. 1.5 Mtr above the starting point.8.46Cum
2727Supply and spreading clean dry river sand in trenches around the cable for cushioning all as specified.6.48Cum
2828Supply and laying in replacement un reinforced precast concrete cable cover, class LV, type 1 flat size 450mmx180mmx40mm complete as in cable protection covering.444Each
2929M & L for Chemical earthing complete with copper earth plate 900x600x5.0mm and copper earth copper earth strip 32mmx6mm, thick burried directly in ground (earth pit not less than 5.0mtr deep and 1.5mtr wide below normal ground level and complete size of pit 1.6M X1.6 M X 5.0M earth plate connected to copper strip of size 50 x 6 mm by brazing only earth strip protected with light grade GI pipe 80mm dia bore from copper earth plate electrode and upto and including the earth test point made of gunmetal Phosporous bronze of size 75x75x25 mm including 25mm bore water pipe medium grade GI tubing including GI Funnel , wire mesh, alternate 5 layers of charcoal (250 Kg) & salt crystal (200 Kg) and top two inches layers with Magnesium sulphate (100 Kg) including excavation in strata, refilling with black cotton soil above the Magnesium Sulphate and removal of the excavate soilland depositing at the place where directed, (PCC pit in PCC (1:3:6) type C1 using 20mm graded stone aggregate , RCC (m) cover 40mm thick in RCC (1:2:4) type B1 using 20 mm grade aggregate reinforced with 8mm dia TMT bars @ 7.5 mm c/c both ways including MS angle iron frame of 40x40x3mm etc watering the earth pit to achieve earth resistance below 01 ohm including6Each
3030Earth continuity conductor or main earthing lead/wire fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 32x6 mm copper strip including PVC black colour sleeves covering.80RM
3131M & L for earthing in replacement complete with galvanised steel earth plate electrode 60x60x6.3 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI strip 32x6 mm dia as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No 3 of SSR Part - I 2009 connected to earthing test point/transformer/pannel all as specified or indicated and testing on completion as directed by Engr-in Charge including necessary excavation and earth work in any type of soil, funnel PCC chamber (1:2:4) type CI , PCC pit cover, charcol, salt including provision of earth lead protected by 40mm dia light grade GI pipe and 20mm dia medium grade GI pipe for watering complete.18Each
3232Supply, laying in trenches or laid under gloors etc and testing XLPE insulated, screened PVC bedded, galvanised step strip armourdm heavy duty HT power cables ISI marked with aluminium conductor, 11000 volts grade corss sectional area 95 sqmm 3 core, 11 KV earthed including taking down old US cable complete all as specified100RM
3333Supply, laying in trenches or laid under gloors etc and testing XLPE insulated, screened PVC bedded, galvanised step strip armourdm heavy duty HT power cables ISI marked with aluminium conductor, 33000 volts grade corss sectional area 95 sqmm 3 core, 33 KV earthed including taking down old US cable complete all as specified60RM
3434S/F outdoor cable and terminals ( heat shrinkcable joint) with joint kits complete for XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts grade cross sec of 95 Sqmm2Each
3535S/F indoor cable and terminals ( heat shrinkcable joint) with joint kits complete for XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts grade cross sec of 95 Sqmm2Each
3636Supply and fix outdoor cable end terminals (heat shrinkcable joint) with joint kits complete for XLPE insulatedm screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 33000 volts grade cross sec of 95 sqmm4Each
3737Supply and fix switch Air break gang operated, triple pole, mechanically operated, mounted on insulator and steel frame with operating mechanism worked from ground level for current rating upto 200 Amps, 11000 volts grade complete including expulsion fuse, single pole, 11000 volts up to 25 amps complete all as specified and directed (Jayshree/ Pactil/Joypuria)4Each
3838Supply, installation, commissioning and testing of Lightning arresters outdoor use, non linear, 12 KV grade, metal oxide (ZnO) type, station class-III for 10 KA rupturing capacity ISI marked (IS 3070) including taking down existing unserviceable Las, complete all as specified and directed, including taking down old US item4Set of three
3939Dismentling of cross-arms of MS channel or angle sections etc complete6Per Qtl
4040Dismentling insulators any type, any size99Each
4141Dismentling of ACSR conductor of any size2.9Per Qtl
4242Dismentling of Earth wire or copper conductor, service feeder or distributor span.1.08Per Qtl
4343Dismantling air break gang operated switches vertical/horizontal mounted including insulators and operating mechanism for repair/replacement of broken/worn out components and insulators etc3Each
4444Dismentling of LA of any size4Per set
4545Taking out existing GI pipe of any size40RM
4646Dismentling of Elect poles/struts, any size2Each
4747Material and labour for steel tubular swaged pole 11.00 mtr long (type 410 SP-55) conforming to IS 2713 complete with bracket, cast iron base plate, finial taper plug, bolts nuts and screws with two coats of synthetic enamel paint (white) over a coat of red oxide primer complete all as specified and directed2Each
4848Excavation in trenches in any type of soil not exceeding 1.5 mtr wide and not exceeding 1.5 meter depth for laying GI tubing/UG cable etc complete all as specified and as directed1.08Cum
4949Excavation in trenches not exceeding 1.5m wide and not exceeding 3.0m deep for foundation of poles stays and struts etcm and getting out in hard/dense soil complete all as specified and directed.0.22Cum
5050PCC 1:4:8 type D-2 (using 40mm graded hard granite stone aggregate) in foundations for pole or in filing as directed by Engineer-in-charge.1.3cum
5151M & L PCC 1:3:6 type C-1 using 20mm graded store aggregate as in stay foundation/coping to poles, filling and mass concrete including necessary form work and taking out existing coping complete all as specified and directed.5.4Cum
5252M&L cross arms bracings, supports, clamps & back plate fabricated from structural steel sections including nuts bolts washers, welding bending cold or hot, driling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and finishing coat of paint.6Per Qtl
5353S & F pin type porcelain, vitreous, white, brown and green insulator including one galvanised mild steel spindle, two galavanised iron washers and one galavanised iron nut, 150mm height, 150mm dia for 11000 volts grade.90Each
5454S & F Disc type insulator, porcelain, viterous 145mm high and 255mm dia ball and socket type white, brown or green 'Two-in-series' assembly for tension with tension clamps for conductors working pressure 11000 volts.9Each
5555M & L Galvanised steel wire fixed on poles without kinks and bends of size 3.15 or 4mm dia.1.08Qtl
5656Supply and install HT 11 Kv outdoor gang operated air break switch suitable for horizontal or vertical mounting with drop out fuse having 12 insulators of rating upto 200 Amps Make Jaipuria/alston/Pactil.3Each
5757Supply and fix lightning arresters high tension expulsion type complete with all fitings, transmission class, suitable 11kv discharge capacity 65 kilo amp.4per set
5858Supply and fixing danger notice board of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figure and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size of HT, 25x20cm.30Each
5959GI tubing light grade 80mm dia galavanised with all fittings laid in trenches as protection of cable.40RM
6060M & L anti climbing device spikes type fabricated out of MS bars (round, square and flat) including nuts, bots, washers and welding in two halves made to shape to suit the cross section of the pole.0.3Per Qtl
6161M & L ACSR conductor fixed on poles without kinds and bends2.9Per Qtl
6262M & L for painting of steel surface of HT steel tubular pole 11 mtr incl accessories like cross arms and clamps etc and painted with one coat of red oxide primer and two coats of aluminium paint over the prepared surface incl numbering of poles approved size with black colour or as approved by Engr-in-charge90Each

AI Tender Summary

OUR REF NO 23175471
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 34 Lakhs
LAST DATE 10-02-2020
Authority
Authority Name Military Engineer Services
Work Description Special Repairs To Ht Ug Cable And Allied Works At Rupa Power House And Special Repairs/Replacement Of 11 Kv Line Conductor And Allied Work At Dahung Area Under Ge 859 Ews
Basic Detail
Tender No 8160/E8
Bidding Type Tender
Location
City Tenga Valley
State Arunachal Pradesh
Key Dates
Publish Date 03 Feb 2020
Submission Date 10 Feb 2020
Open Date 12 Feb 2020
Finance
Tender Value 34 Lakhs
Tender Fee 500
EMD 68000
Exemption Not Available
Document List
Tenderdocuments8160.pdf
BOQ_349841.xls
B340BB68-2E1F-49A0-8E7E-6B396683739C.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Feb 03, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
Feb 01, 2020
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Feb 10, 2020
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Feb 10, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Feb 12, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tenderdocuments8160.pdf

xls

BOQ_349841.xls

html

B340BB68-2E1F-49A0-8E7E-6B396683739C.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders