Supply , Installation , Testing And Commissioning Of Inverter Type Split Ac Units At Ktdc-Tamarind Easy Hotel , Kannur Supply Installation , Testing And Commissioning Of 5 Star Invertertype Split Ac Units
Tender Overview
Project Description
Supply , Installation , Testing And Commissioning Of Inverter Type Split Ac Units At Ktdc-Tamarind Easy Hotel , Kannur Supply Installation , Testing And Commissioning Of 5 Star Invertertype Split Ac Units , Supply , Installation , Testing And Commissioning Of Inverter Type Full Copper ( Condensor & Evaporator Coils ) Split Type High Wall Mounted Air Conditioner Unit With Cordless Remote Of Following Ratings Including Fixing Of Indoor & Outdoor Units , Initial Gas Charging As Per Manufacturer Standards , Giving Power Connection To Nearest Power Plug Point / Mcs With 16A Plug Top , Connecting Indoor And Outdoor Units Using Hard Drawn Copper Refrigerant Pipes Insulated With Nitrile Rubber Or Equivalent Material Of Minimum 3 Mtrs , Pvc Insulated Flexible Copper Cable Of Minimum 3 Meters As Per Original Manufacturers Standards , Necessary Drain Water Line Using 20Mm Pvc Pipe Minimum 3 Mtrs . Necessary Opening On Wall Shall Be Made For Drawing Refrigerant / Power / Drain Lines And Shall Be Restored To Normal Using Cement Plastering . ( Drain Pipe Line Shall Be Properly Fixed And Clamped To Line And Level As Per The Direction Of Site Engineer In Charge ) . Approved Make: Bluestar/Daikin/Panasonic/O General/Carrier/Hitachi/Mitsubushi , 1 . 0Tr Capacity Inverter Type 5 Star Rated Working On Single Phase 240 V , 50 Hz +/-1% Ac Supply Of Good Quality And Approved Make , 1 . 5Tr Capacity Inverter Type 5 Star Rated Working On Single Phase 240 V , 50 Hz +/-1% Ac Supply Of Good Quality And Approved Make , Supply & Laying Additional Refrigerant Lines ( Both Suction & Discharge ) Using Hard Drawn Copper Pipe Of The Suitable Sizes Recommended By The Manufacturer For 1 . 0Tr Ac Unit Including Nitrile Rubber Thermal Insulation Of Good Quality To Extend The Refrigerant Gas Connection Till Outdoor Unit As Required At Site . , Supply & Laying Additional Refrigerant Lines ( Both Suction & Discharge ) Using Hard Drawn Copper Pipe Of The Suitable Sizes Recommended By The Manufacturer For 1 . 5Tr Ac Unit Including Nitrile Rubber Thermal Insulation Of Good Quality To Extend The Refrigerant Gas Connection Till Outdoor Unit As Required At Site . , Supply & Erecting Additional 20Mm Pvc Drain Piping Of Good Quality To Extend Water Drain Connection Till Nearest Silt Terminal As Required At Site . , Supply & Drawing Additional Control Cable Of Suitable Size Recommended By The Manufacturer Between Indoor And Outdoor Unit . , Supply & Providing Wall Mounting Type 4 Kva Voltage Stabilizer Designed For Air Conditioning Load Working On 240V , 50Hz Single Phase Ac Supply To Feed Output Voltage At +/- 10% Tolerance With Automatic Low Voltage & High Voltage Cutoff , Built In Thermal Overload Protection , Powder Coated Enclosure Etc . Complete Good Quality And Approved Make And Giving Connection . ( Approved Make: Vguard Or Equivalent Reputed Brand ) , Supply & Fixing Supporting Stand / Clamp For Fixing The Outdoor Unit Using Suitable Support Bars /Anchor Bolts And Safety Hook Up Etc . Including All Accessories Etc . Complete . , Less Buyback Charges For 1 . 0 /1 . 5Tr Capacity Existing Ac Units At Site Including All Accessories
BOQ
| Name of Work:Supply, Installation, Testing and Commissioning of Inverter type split AC units at KTDC-Tamarind easy Hotel, kannur | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Supply,Installation, testing and commissioning of inverter type full copper (Condensor & evaporator coils) Split type High wall mounted Air Conditioner unit with cordless remote of following ratings including fixing of Indoor & outdoor units, initial gas charging as per manufacturer standards, giving power connection to nearest Power plug point / MCS with 16A plug top, connecting indoor and outdoor units using hard drawn copper refrigerant pipes insulated with nitrile rubber or equivalent material of minimum 3 mtrs, PVC insulated flexible copper cable of minimum 3 meters as per original manufacturers standards, necessary drain water line using 20mm PVC pipe minimum 3 mtrs. Necessary opening on wall shall be made for drawing refrigerant / power / drain lines and shall be restored to normal using cement plastering. (Drain pipe line shall be properly fixed and clamped to line and level as per the direction of site engineer in charge). Approved Make: BlueStar/Daikin/Panasonic/O General/Carrier/Hitachi/Mitsubushi | |||
| 2 | 1.1 | 1.0TR Capacity inverter type 5 star rated working on single Phase 240 V, 50 Hz +/-1% AC supply of good quality and approved make | 26 | Nos | |
| 3 | 2 | 1.5TR Capacity inverter type 5 star rated working on single Phase 240 V, 50 Hz +/-1% AC supply of good quality and approved make | 7 | Nos | |
| 4 | 3 | Supply & laying additional refrigerant lines (Both suction & discharge) using hard drawn copper pipe of the suitable sizes recommended by the manufacturer for 1.0TR AC unit including nitrile rubber thermal insulation of good quality to extend the refrigerant gas connection till outdoor unit as required at site. | 75 | m | |
| 5 | 4 | Supply & laying additional refrigerant lines (Both suction & discharge) using hard drawn copper pipe of the suitable sizes recommended by the manufacturer for 1.5TR AC unit including nitrile rubber thermal insulation of good quality to extend the refrigerant gas connection till outdoor unit as required at site. | 15 | m | |
| 6 | 5 | Supply & erecting additional 20mm PVC drain piping of good quality to extend water drain connection till nearest silt terminal as required at site. | 50 | m | |
| 7 | 6 | Supply & drawing additional control cable of suitable size recommended by the manufacturer between indoor and outdoor unit. | 90 | m | |
| 8 | 7 | Supply & providing wall mounting type 4 kVA Voltage Stabilizer designed for Air conditioning load working on 240V, 50Hz Single Phase AC supply to feed output voltage at +/- 10% tolerance with automatic low voltage & high voltage cutoff, built in thermal overload protection, powder coated enclosure etc. complete good quality and approved make and giving connection. (Approved make: Vguard or equivalent reputed brand) | 33 | Nos | |
| 9 | 8 | Supply & fixing supporting stand / clamp for fixing the outdoor unit using suitable support bars /anchor bolts and safety hook up etc. including all accessories etc. complete. | 21 | set | |
| 10 | 9 | Less buyback charges for 1.0 /1.5TR capacity existing AC units at site including all accessories | 10 | set |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender