| 1 | 1 | Supply and erection of pre-stressed cement concrete pole of suitable length with a given planting depth confirming to IS1678-1978 below ground level in excavated pit of suitable dimension complete in all respect as per satisfaction of Engineer-in-charge. | | | |
|---|
| 2 | 1.01 | PCC pole overall length 9 metre, planting depth 1.83 metre, top dimensions 105mm x 115mm, bottom dimensions 105mm x 315mm, load capacity 200 kg and weight 478 kg. | | 10 | Each |
|---|
| 3 | 1.02 | PCC pole overall length 11 metre, planting depth 1.83 metre, top dimensions 152.4mm x 203.2mm, bottom dimensions 152.4mm x 368.3mm, load capacity 363 kg and weight 1146 kg. | | 40 | Each |
|---|
| 4 | 2 | Supply & erection of dead end clamps of di-cast Aluminium (size 20-100sq. mm) for making T line end terminal including cost of nuts & bolts etc. complete in all respect as approved by the Engineer-in-Charge. | | 10 | Each |
|---|
| 5 | 3 | Supply & erection of PG di-cast Aluminium suitable for ACSR conductor size 30-50sq. mm for making T/lines ends including cost of nut and bolts etc. as approved by Engineer-in-charge. | | 40 | Each |
|---|
| 6 | 4 | Supply & erection of PVC insulated PVC sheathed aluminium conductor single core cable size 70sq. mm for providing jumpering arrangement on overhead lines. | | 50 | Mtr |
|---|
| 7 | 5 | Supply & erection of Egg/ strain insulator as required at site confirming to ISI specifications as approved by Engineer-in-charge. | | 40 | Each |
|---|
| 8 | 6 | Supply & erection of 11 KV polymer pin insulator with GI pin confirming to ISI specifications. The item includes supply and erection of nuts bolts and other accessories whatsoever required at site for fixing it to the structure pole. The job is to be completed as approved by Engineer-in-charge. | | 150 | Each |
|---|
| 9 | 7 | Supply & erection of 11 KV polymer disc insulator confirming to ISI specifications. The item includes supply and erection of nuts bolts and other accessories whatsoever required at site for fixing it to the structure pole. The job is to be completed as approved by Engineer-in-charge. | | 36 | Each |
|---|
| 10 | 8 | Supply & erection of shackle insulator (medium) with fixing bolts and nuts confirming to relevent ISI specification as approved by Engineer-in-charge | | 110 | Each |
|---|
| 11 | 9 | Supply & erection of stay set consisiting of 19/20mm dia. 1.8 metre long G.I. stay rod duly threaded upto 300mm at one end and shped on the other end. MS plate size 30cm x 30cm x 6mm with 20mm dia. hole drilled in the centre of the plate G.I. stay wire size 7/10 SWG, G.I. thimble for stay, binding, Egg/Strain insulator, MS elbow made out of 16mm plain sheet and a piece of 50mm x 50mm x 6mm size 20cm long angle iron made to the shape as approved by Engineer-in-charge. Stay set complete shall be fixed to the pole by providing suitable size full clamps made out 50mm x 6mm size MS flat with required number of nut and bolts 16mm dia. on one end and shall be embedded in the on the other end. The stay plate shall be covered with cement concrete having total volume of the concrete not less that 0.042Cum. The job shall include excavation of pit and back filling and after pouring concrete with excavated soil etc. as approved/desired by the the Engineer-in-charge. | | 10 | Sets |
|---|
| 12 | 10 | Supply & erection of stay set consisiting of 19/20mm dia. 2.4metre long G.I. stay rod duly threaded upto 300mm at one end and shped on the other end. MS plate size 30cm x 30cm x 6mm with 20mm dia. hole drilled in the centre of the plate G.I. stay wire size 7/10 SWG, G.I. thimble for stay, binding, Egg/Strain insulator, MS elbow made out of 16mm plain sheet and a piece of 50mm x 50mm x 6mm size 20cm long angle iron made to the shape as approved by Engineer-in-charge. Stay set complete shall be fixed to the pole by providing suitable size full clamps made out 50mm x 6mm size MS flat with required number of nut and bolts 16mm dia. on one end and shall be embedded in the on the other end. The stay plate shall be covered with cement concrete having total volume of the concrete not less that 0.042Cum. The job shall include excavation of pit and back filling and after pouring concrete with excavated soil etc. as approved/desired by the the Engineer-in-charge. | | 20 | Sets |
|---|
| 13 | 11 | Supply & erection of cradle guard suitable for 2 lines overhead line as required at site as approved by Engineer-in-charge. | | 10 | Each |
|---|
| 14 | 12 | Supply & erection of cradle guard suitable for 4 lines overhead line as required at site as approved by Engineer-in-charge. | | 10 | Each |
|---|
| 15 | 13 | Supply and erection of pre-stressed cement concrete pole of suitable length with a given planting depth confirming to IS1678-1978 below ground level in excavated pit of suitable dimension complete in all respect as per satisfaction of Engineer-in-charge. | | | |
|---|
| 16 | 13.01 | Circular Aluminium conductor, conductor screened with extruded semiconducting compound, XLPE insulated,insulation screened with extruded semiconducting combination in combination with copper tape (0.3KA for 1sec.) cores laid up, FRLS PVC inner sheathed, galvanised steel strip armoured and overall FRLS PVC sheathed cable confirming to IS:7098/II/85 working voltage 11KV(E) grade 150sq.mm (Three Core) | | 3000 | Mtr |
|---|
| 17 | 13.02 | Circular Aluminium conductor, conductor screened with extruded semiconducting compound, XLPE insulated, insulation screened with extruded semiconducting combination in combination with copper tape (0.3KA for 1sec.) cores laid up, FRLS PVC inner sheathed, galvanised steel strip armoured and overall FRLS PVC sheathed cable confirming to IS:7098/II/85 working voltage 11KV(E) grade 300sq.mm (Three Core) | | 700 | Mtr |
|---|
| 18 | 13.03 | Circular Aluminium conductor, conductor screened with extruded semiconducting compound, XLPE insulated, insulation screened with extruded semiconducting combination in combination with copper tape (0.3KA for 1sec.) cores laid up, FRLS PVC inner sheathed, galvanised steel strip armoured and overall FRLS PVC sheathed cable confirming to IS:7098/II/85 working voltage 11KV(E) grade 35sq.mm (Three Core) | | 2300 | Mtr |
|---|
| 19 | 14 | Supply and erection of double walled corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation (making necessary trench), placing the pipe in position and back filling with excavated soil etc. of the required size. | | | |
|---|
| 20 | 14.01 | Double walled corrugated (DWC) HDPE pipe 50/ 38mm (outer/ inner dia.) | | 50 | Mtr |
|---|
| 21 | 14.02 | Double walled corrugated (DWC) HDPE pipe 180/ 152mm (outer/ inner dia.) | | 900 | Mtr |
|---|
| 22 | 15 | Supply & erection of 11 KV GO switch confirming to ISI specifications. The item includes supply and erection of operating pipe and handle arrangement of MS flat 50mm x 6mm and channels 75mm x 40mm sheet. The GO switch is to be fitted with locking arrangement so as it locks upward on 'ON' position and locks downward in 'OFF' position. The entire GO switch assembly/unit should be properly earthed and the job is to be completed as approved by Engineer-in-charge. | | 60 | Each |
|---|
| 23 | 16 | Supply & erection of 'D' iron clamp 50mm x 6mm flat iron complete with fixing bolts and nuts (16mm x 200mm) including making holes in the pole as approved by Engineer-in-charge. | | 500 | Each |
|---|
| 24 | 17 | Supply & erection of 'bar shape shape cross arm of MS channel 75mm x 40mm size 1200 mm long made of FRP material with 4 holes drilled in it for ( 2 for supporting pin insulators. Distance between CC to be 1070mm and two for clamp for mounting with PCC pole. The item include supply and erection of half clamp made out of 50mmx6mm flat including cost of nut & bolts as approved by Engineer-in-charge. | | 80 | Each |
|---|
| 25 | 18 | Supply & erection of 11 KV Top Hamper made out of MS flat 50mmx 6xmm as per standard drawing. The item includes supply and erection of nut and bolts( 19mm x125mm) asrequired. This job is completed as approved by Engineer-in-charge. | | 10 | Each |
|---|
| 26 | 19 | Supply and Erection of MS angle iron size 50mm x 50mm x 6mm thick with cutting, bending and necessary holes as desired by Engineer-in-charge at site. | | 120 | Mtr |
|---|
| 27 | 20 | Supply and Erection of MS channel iron size 100mm x 50mm x 6mm thick with cutting, bending and necessary holes as desired by Engineer-in-charge at site. | | 250 | Mtr |
|---|
| 28 | 21 | Supply and Erection of MS channel iron size 75mm x 40mm x 4mm thick with cutting, bending and necessary holes as desired by Engineer-in-charge at site. | | 75 | Mtr |
|---|
| 29 | 22 | Supply and Erection of MS flat iron size 50mm x 5mm thick with cutting, bending and necessary holes as desired by Engineer-in-charge at site. | | 50 | Mtr |
|---|
| 30 | 23 | Supply & erection of 4 way 11 KV ring main unit comprising of 4 no. locl break switches and one no. VCB with 300/5 A CT ratio CTs enclosed in SF6 gas enclosure. The panel shall be out doo mouinting type complete in all rspec gs in cludwes OC,SC and eartyh fault protection, capacitive voltage indicators and self power relay complete in all respects. | | 1 | Each |
|---|
| 31 | 24 | Supply, stringing and sagging of aluminium conductor steel reinforced (ACSR) on poles including binding with insulators using aluminium wires complete as desired by the Engineer in charge of the site. | | | |
|---|
| 32 | 24.01 | ACSR-DOG conductor (100 sq. mm) Size (6/4.55 Al.+1/4.55mm GI) | | 100 | Mtr |
|---|
| 33 | 24.02 | ACSR-RABIT conductor (50 sq. mm) Size (6/3.35 Al.+1/3.35mm GI) | | 200 | Mtr |
|---|
| 34 | 24.03 | ACSR-RACOON conductor (80 sq. mm) Size (6/4.09 Al.+1/4.09mm GI) | | 200 | Mtr |
|---|
| 35 | 25 | S/E of Heat shrinkable cable end termination for 11 KVA /6.6 | | | |
|---|
| 36 | 25.01 | Heat Shrinkable for cable size 120-185 sq. mm (Outdoor Type) | | 75 | Each |
|---|
| 37 | 25.02 | Heat Shrinkable for cable size 240-300 sq. mm (Outdoor Type) | | 15 | Each |
|---|
| 38 | 25.03 | Heat Shrinkable for cable size 35 sq. mm (Outdoor Type | | 20 | Each |
|---|
| 39 | 26 | Supply & erection of M.S. sheet danger notice plate at least 2 mm thick and vitreous enameled white on both sides and with inscriptions in the signal red colour on the front side as required : | | | |
|---|
| 40 | 26.01 | Size 200 mm x 200 mm | | 60 | Each |
|---|
| 41 | 27 | Earthing of Sheet metal/ iron clad Switches and metallic cases etc., with No. 7/12 S.W.G. (7/2.80mm dia.) G.I. wire in 20mm dia G.I. pipe partly recessed and partly on surface complete with 135cm long 50mm dia. G.I. earth pipe with G.I. reducing socket (50mm x 20mm) including erection of the same, 10 metre below ground level with necessary charcoal & salt mixture etc., up to 13 metre in length (including boring & refilling). | | 240 | Each |
|---|
| 42 | 28 | Supply and laying of XLPE/ P.V.C. insulated P.V.C. sheathed aluminium conductor un-armoured cable working voltage upto and including 1100 volts grade to be laid loose in the existing trench or pipe as per PWD General Specifications 2010:- | | | |
|---|
| 43 | 28.01 | XLPE/ PVC insulated PVC sheathed aluminium conductor unarmoured cable working voltage 1100volts grade 150sq.mm (3 ½ Core) | | 500 | Mtr |
|---|
| 44 | 28.02 | XLPE/ PVC insulated PVC sheathed aluminium conductor unarmoured cable working voltage 1100volts grade 240sq.mm (3 ½ Core) | | 100 | Mtr |
|---|
| 45 | 29 | S/E of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary | | | |
|---|
| 46 | 29.01 | Aluminium cable core size 95 sq. mm | | 80 | Each |
|---|
| 47 | 29.02 | Aluminium cable core size 150 sq. mm | | 150 | Each |
|---|
| 48 | 29.03 | Aluminium cable core size 240 sq. mm | | 50 | Each |
|---|
| 49 | 30 | Supply & erection of G.I pipe along the pole along with 50x6mm size M.S.flat for protection of under ground cables.(up to 3 m in length) including painting wherever required complete to Satisfaction of client. | | | |
|---|
| 50 | 30.01 | G.I. pipe 80 mm dia | | 10 | Each |
|---|
| 51 | 30.02 | G.I. pipe 100 mm dia | | 150 | Each |
|---|
| 52 | 31 | Supply & Erection of GI wire no. 8 SWG on pole including binding with the existing system as maybe desired. | | 300 | Kg |
|---|
| 53 | 32 | Dismentlement of ACSR off sizes from the over head line and storing at site store. | | 15000 | Mtr |
|---|
| 54 | 33 | Distmantlement and re-erection of distribution transformers off sizes. | | 50 | Each |
|---|
| 55 | 34 | TRANSFORMER | | | |
|---|
| 56 | 34.01 | Supply & errection, placing on 2 pole structure, testing and commissioning of 100KVA 11KV/433V outdoor type transformer suitable for 3 phase 50 HZ A.C. supply, oil immersed naurally air cooled ONAN core type connected with standard fitting as per IS 1180/2014 (part-I) amended up to date. Aluminium wound with, temperature guage complete in all respects as PSPCL specificaions and as desired and approved by the Engineer in charge having following components:- | | 6 | Each |
|---|
| 57 | 34.02 | housed in oil tight sheet steel container having corrugated side walling angle iron and flat and the edges of the colling fin to provide rigidity of the fins keeping sufficient clearance of the bottom edge of the fins above the ground so that to prevent any damages to the fins by lifting with the following specifications, | | | |
|---|
| 58 | 34.03 | accessories and standard fitting | | | |
|---|
| 59 | 34.04 | Connections | | | |
|---|
| 60 | 34.05 | Delta on HV | | | |
|---|
| 61 | 34.06 | Star on LV side with neutral brought out | | | |
|---|
| 62 | 34.07 | Capacity : 100 KVA | | | |
|---|
| 63 | 34.08 | No load voltage ratio of 11 KV/433 volt | | | |
|---|
| 64 | 34.09 | Temperature rise (IS 2026) not to exceed 45oC by thermometer in oil and 55oC resistance at 45oC temperature. | | | |
|---|
| 65 | 34.1 | Rating : Continuously rating for full load | | | |
|---|
| 66 | 34.11 | First filling of transformer oil | | | |
|---|
| 67 | 34.12 | accessories and standard fitting | | | |
|---|
| 68 | 34.13 | Conservator with oil level indicator | | | |
|---|
| 69 | 34.14 | Rating and name plate | | | |
|---|
| 70 | 34.15 | Terminal making plate | | | |
|---|
| 71 | 34.16 | Earthing terminal minimum two 12 oild filling hole with capacity. | | | |
|---|
| 72 | 34.17 | Air released device | | | |
|---|
| 73 | 34.18 | De-hydrating slica gel breather | | | |
|---|
| 74 | 34.19 | Filter vent | | | |
|---|
| 75 | 34.2 | Explosion vent | | | |
|---|
| 76 | 34.21 | Pocket for 4\" dia thermometer with max. reading pointer and resetting device. | | | |
|---|
| 77 | 34.22 | Terminal arrangements | | | |
|---|
| 78 | 34.23 | Lifting lugs | | | |
|---|
| 79 | 34.25 | Make PVJ/Kirloskar/JB Bathinda | | | |
|---|
| 80 | 34.26 | Liassioning work with PSPCL for getting passed electrical installation and connection etc complete as required. | | | |
|---|
| 81 | 35 | Electric Cable trench | | | |
|---|
| 82 | 35.01 | Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15cm layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres. | | 1993.48 | Cum |
|---|
| 83 | 36 | Cement concrete 1:4:8 with 40 mm gauge stone ballast. using concrete mixer volumetric type | | 196.73 | Cum |
|---|
| 84 | 37 | First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth. | | 672.52 | Cum |
|---|
| 85 | 38 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS 1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. | | 190.86 | Cum |
|---|
| 86 | 39 | Shuttering for faces of concrete foundations and foundation beam and plinth beam (vertical or battering). | | 5246 | Sqm |
|---|
| 87 | 40 | Cold twisted deformed (Ribbed/Tor Steel Bar) Bars Fe 500 grade as per IS 1786-1985, for RCC works, where not including in the complete rate of RCC including bending and placing in position complete. | | 140.26 | Qtl |
|---|
| 88 | 41 | 12.5mm thick cement plaster 1:5 | | 2924 | Sqm |
|---|
| 89 | 42 | Steel work, fixed independently without connecting plates, including cutting, hoisting and fixing in position: | | | |
|---|
| 90 | 42.01 | Tees, angles and channels | | 235.21 | Qtl |
|---|
| 91 | 42.02 | Flats | | 51.22 | Qtl |
|---|