Electrical Work For Replcement And Repair Of Electrical Distribution Panel In Central Jail , Ajmer
Tender Value
9.83 Lakhs
Estimated cost
Bid Submission
13 Jan 2020
0 days left
EMD
19660
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ajmer → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Electrical Work For Replcement And Repair Of Electrical Distribution Panel In Central Jail , Ajmer
BOQ
| Name of Work: Electrical Work For Replcement & Repair of Electrical Distribution Panel in Central Jail , Ajmer | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | P & F ISI marked (IS :3854) 16 amp. flush type switch including cutting hole in tile and making connection testing etc. as required. Group-1 | BI01010001010000000000000515BI0100001112 | 60 | Each |
| 2 | 2 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required. Group-1 | BI01010001010000000000000515BI0100001113 | ||
| 3 | 2.1 | 3x 1.5 sq.mm | BI01010001010000000000000515BI0100001114 | 200 | Mtr. |
| 4 | 2.2 | 2 x 2.5 sq. mm. + 1x1.5sqmm | BI01010001010000000000000515BI0100001115 | 200 | Mtr. |
| 5 | 3 | P & F paper phenolic resin bonded laminates confirming to IS : 2036 - 1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc plated nut and bolts as required. Group-1 | BI01010001010000000000000515BI0100001116 | ||
| 6 | 3.1 | 3.0 mm thick | BI01010001010000000000000515BI0100001117 | 3 | Sqm. |
| 7 | 4 | P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections, testing etc. as required. Group-A1 | BI01010001010000000000000515BI0100001118 | ||
| 8 | 4.1 | Single pole MCB 6 A to 32 A rating | BI01010001010000000000000515BI0100001119 | 20 | Each |
| 9 | 4.2 | Double pole MCB 40 A 63 A rating | BI01010001010000000000000515BI0100001120 | 20 | Each |
| 10 | 4.3 | Four pole MCB 40 A 63 A rating | BI01010001010000000000000515BI0100001121 | 30 | Each |
| 11 | 5 | P & F ISI marked (IS :3854) 6 amp. flush type switch including cutting hole in tile and making connection testing etc. as required. Group-1 | BI01010001010000000000000515BI0100001122 | 1000 | Each |
| 12 | 6 | P & F of 3 pin 6 amp. flush type socket including cutting hole in tile and making connection testing etc. as required. Group-1 | BI01010001010000000000000515BI0100001123 | 25 | Each |
| 13 | 7 | P & F socket size flush type 120/280 watt rotary 5 step fan regulator including making connection testing etc. as required. Group-1\n | BI01010001010000000000000515BI0100001124 | 25 | Each |
| 14 | 8 | SITC of wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel made out of CRCA sheet , required hardware ,duly treated for derusting in 7 tank process with dephosphating and with powder coating on both side of panel in desired shade The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness, separate detachable gland plate M.S. base channel, hinged door with locking arrangement for equipment/switchgear. Thickness of sheet shall not be less than 1.6 mm up to 600 mm length / width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required . Side walls and cable alley compartments having bolted type doors with / without detachable extension type structure. (only outer area on all sides shall be measured & panel to be fabricated from CPRI approved fabricator). Interconnection between bus bar and switchgears / cable shall be rigidly supported and made out by flexible copper wires (up to 125 amp ) and by solid bus bar (>125 amp ). All joints / interconnections of copper bus bar shall be dully tinned. Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves. Earth and Neutral bus bar shall be half of the size of phase bus bar. | BI01010001010000000000000515BI0100001125 | 37 | Sqm. |
| 15 | 9 | Supplying and fixing of Aluminium / Copper bus bar by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. | BI01010001010000000000000515BI0100001126 | ||
| 16 | 9.1 | Electrolytic grade Aluminium bus bar | BI01010001010000000000000515BI0100001127 | 60 | Kg. |
| 17 | 10 | SF of 110/220 V, LED (22.5 mm dia ) Indicating lamp with integral circuit, terminal block, including connection etc. as required. Group-1 | BI01010001010000000000000515BI0100001128 | ||
| 18 | 10.1 | Red/yellow/Green colour | BI01010001010000000000000515BI0100001129 | 18 | Each |
| 19 | 11 | SITC of quick make and quick break 4 POLE current limiting MCCB having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings and conforming to IS 60947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip ,earth fault trip, push ( test ) to trip , including making connections with lugs & spreaders, etc. as required. Group-1 With Thermal Magnetic release | BI01010001010000000000000515BI0100001130 | ||
| 20 | 11.1 | up to 100 Amp , 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu | BI01010001010000000000000515BI0100001131 | 18 | Each |
| 21 | 11.2 | 160 Amp, 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu | BI01010001010000000000000515BI0100001132 | 5 | Each |
| 22 | 11.3 | 200 Amp , 25/35kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu | BI01010001010000000000000515BI0100001133 | 6 | Each |
| 23 | 11.4 | 250 Amp , 35 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu | BI01010001010000000000000515BI0100001134 | 1 | Each |
| 24 | 11.5 | 400 Amp ,35 kA, adjustable O/L & adjustable S/C setting, Ics = 100 % Icu | BI01010001010000000000000515BI0100001135 | 1 | Each |
| 25 | 12 | Supply and fixing of following accessories for MCCB | BI01010001010000000000000515BI0100001136 | ||
| 26 | 12.1 | Direct Rotary Handle | BI01010001010000000000000515BI0100001137 | 28 | Each |
| 27 | 13 | P&F on load change over switch, front handle operated, four pole 415 V conforming to IS:13947 P-III including connections , testing etc. as required. Group-1 in the following rating: | BI01010001010000000000000515BI0100001138 | ||
| 28 | 13.1 | Open execution type 400 A | BI01010001010000000000000515BI0100001139 | 1 | Each |
| 29 | 14 | P&F Insulated DMC fuse bases suitable for Din type HBC fuse links conforming to IS:9224-79 including making connections with lugs, testing etc. as required. Group-1 | BI01010001010000000000000515BI0100001140 | ||
| 30 | 14.1 | 250 A rating | BI01010001010000000000000515BI0100001141 | 3 | Each |
| 31 | 15 | P/Laying P.V.C. / XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required. of size. Armoured | BI01010001010000000000000515BI0100001142 | ||
| 32 | 15.1 | 10.0 Sq.mm 4 core | BI01010001010000000000000515BI0100001143 | 300 | Mtr. |
| 33 | 15.2 | 16.0 Sq.mm 4 core | BI01010001010000000000000515BI0100001144 | 100 | Mtr. |
| 34 | 15.3 | 25.0 Sq.mm 3.5 core | BI01010001010000000000000515BI0100001145 | 100 | Mtr. |
| 35 | 16 | P/Laying P.V.C. / XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with Copper conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required. Group-1 of size. Armoured | BI01010001010000000000000515BI0100001146 | ||
| 36 | 16.1 | 95.0 Sq.mm | BI01010001010000000000000515BI0100001147 | ||
| 37 | 16.2 | 3.5 core | BI01010001010000000000000515BI0100001148 | 10 | Mtr. |
| 38 | 17 | Supplying and making one end termination with heavy duty single compression brass gland SIBG type, heavy duty aluminium lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size. | BI01010001010000000000000515BI0100001149 | ||
| 39 | 17.1 | 3.5 x 70.0 sq.mm | BI01010001010000000000000515BI0100001150 | 2 | Set |
| 40 | 17.2 | 3.5 x 95.0 sq.mm | BI01010001010000000000000515BI0100001151 | 2 | Set |
| 41 | 18 | Supplying and making end termination with heavy aluminium lugs ( Pin / ring type ) duly crimped with crimping tool, PVC tape etc of following size. | BI01010001010000000000000515BI0100001152 | ||
| 42 | 18.1 | 10.0 Sq.mm | BI01010001010000000000000515BI0100001153 | 20 | Each |
| 43 | 18.2 | 16.0 Sq.mm | BI01010001010000000000000515BI0100001154 | 20 | Each |
| 44 | 18.3 | 25.0 Sq.mm | BI01010001010000000000000515BI0100001155 | 10 | Each |
| 45 | 18.4 | 35.0 Sq.mm | BI01010001010000000000000515BI0100001156 | 20 | Each |
| 46 | 18.5 | 50.0 Sq.mm | BI01010001010000000000000515BI0100001157 | 20 | Each |
| 47 | 18.6 | 70.0 Sq.mm | BI01010001010000000000000515BI0100001158 | 20 | Each |
| 48 | 18.7 | 95.0 Sq.mm | BI01010001010000000000000515BI0100001159 | 20 | Each |
| 49 | 18.8 | 120.0 Sq.mm | BI01010001010000000000000515BI0100001160 | 10 | Each |
| 50 | 18.9 | 150.0 Sq.mm | BI01010001010000000000000515BI0100001161 | 10 | Each |
| 51 | 19 | 240.0 Sq.mm | BI01010001010000000000000515BI0100001162 | 10 | Each |
| 52 | 20 | S & Making Heat shrinkable type outdoor straight through joint for following size of PVC/ XLPE insulated aluminium conductor cable of 1.1 KV grade including cost of compound, sleeves etc. as required. Group-1 | BI01010001010000000000000515BI0100001163 | ||
| 53 | 20.1 | 3.5 x 25.0 sq.mm | BI01010001010000000000000515BI0100001164 | 5 | Set |
| 54 | 20.2 | 3.5 x 35.0 sq.mm | BI01010001010000000000000515BI0100001165 | 5 | Set |
| 55 | 20.3 | 3.5 x 50.0 sq.mm | BI01010001010000000000000515BI0100001166 | 5 | Set |
| 56 | 21 | Supply, Fabricating & installing following sizes of powder coated perforated M.S. cable trays including horizontal and vertical bends, reducers tees, cross members and other accessories as required. Group-1 and duly suspended from the ceiling with M.S. suspenders, fastners, supports etc. as required. | BI01010001010000000000000515BI0100001167 | ||
| 57 | 21.1 | 300mm x 50mm x 1.6mm | BI01010001010000000000000515BI0100001168 | 40 | Mtr. |
| 58 | 22 | Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 25 mm dia. G.I. 'B' class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. Group-1 | BI01010001010000000000000515BI0100001169 | 6 | Set |
| 59 | 23 | S & Laying following size earth wire / strip in horizontal or vertical run in ground / surface / recess including riveting, soldering, saddles, making connection etc. as required. | BI01010001010000000000000515BI0100001170 | ||
| 60 | 23.1 | 32 mm x 6 mm G.I. ( Hot Dipped ) Strip | BI01010001010000000000000515BI0100001171 | 40 | Mtr. |
| 61 | 23.2 | 8 SWG G.I. ( Hot Dipped ) Wire | BI01010001010000000000000515BI0100001172 | 100 | Mtr. |
| 62 | 24 | S & Laying following size' B ' class G.I. Pipe confirming to IS : 1239 P - 1 ( 1990 ) with accessories for laying earth conductor/strip / cable in ground/surface/recess as required. Group-1 | BI01010001010000000000000515BI0100001173 | ||
| 63 | 24.1 | 50 mm dia. | BI01010001010000000000000515BI0100001174 | 20 | Mtr. |
| 64 | 25 | P & F paper phenolic resin bonded laminates confirming to IS : 2036 - 1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc plated nut and bolts as required. Group-1 | BI01010001010000000000000515BI0100001175 | ||
| 65 | 25.1 | 9.0 mm thick | BI01010001010000000000000515BI0100001176 | 0.5 | Sqm. |
| 66 | 26 | Supply & Fixing ISI marked ( IS : 15683 ) Portable Fire Extinguisher, ABC type, finished externally with red enamel paint, complete in all respects including initial fill and wall suspension of following capacity. \nMake:-Cease fire, Safex, Minimax, Newage, Peterautokit, Eversafe, Ansul | BI01010001010000000000000515BI0100001177 | ||
| 67 | 26.1 | 4 kg | BI01010001010000000000000515BI0100001178 | 4 | Each |
| 68 | 27 | P & F of IP 20 LED tube Light 20 watt with external batten made from CRCA sheet steel suitable to replace T-8/ T-12 tube light, internal driver, 2000 luman + 5% tolerance system luman efficiency of 100Lm/ watt minimum expected life time of 25000 burning hours, CCT5700 K, ANSI, CRI 80, driver efficiency>85%, Life expectancy of driver min 30000 hrs. PF 0.95 at full load /230 volt AC.\nMake:- Philips / HPL / Surya / Bajaj / Havell's / Crompton / Wipro / Syska / K-Lite / Lighting Science & EESL approved make. | BI01010001010000000000000515BI0100001179 | 100 | Each |
| 69 | 28 | Providing experienced and Highly skilled/skilled/ semi-skilled/Un Skilled labour for electric repair/ maintenance / operation of Air conditioning/Air cooling/Fire fighting/Lift/DG set/CCTV/EPABX or any other electromechanical systems as per requirement (one shift of 8 Hrs per day for 26 Working Days in a month) | BI01010001010000000000000515BI0100001180 | ||
| 70 | 28.1 | Semi skilled labour | BI01010001010000000000000515BI0100001181 | 3 | Each Per Month |
| 71 | 28.2 | Un skilled labour | BI01010001010000000000000515BI0100001182 | 2 | Each Per Month |
| 72 | 29 | P&F of IP65 protected LED Street Light Luminaire on existing bracket. Fixture made of powder coated single piece pressure die cast aluminum with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover ( from 45W onwards ) and should be secondary lens on each LED . The System level Luminaire efficacy >=100 with High Power LEDs of CREE/NICHIA/OSRAM/PHILIPS/SEOUL make is to be used .The LED Driver shall be BIS certified and Input Voltage AC 110 to 270 V AC with Input Frequency 50Hz±3% Power Factor >0.95 Driver Efficiency >85% , THD(I) <10% Humidity 10% to 90% RH Working Temp -20C to 50C . Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% initial lumens maintained ,Rendering Index >75% .Surge protection shall be min = 5 KV internal and min 10 KV external. Manufactures Word Mark/Name Engraved/Embossed on die cast housing to allow traceability/authenticity till life of fixture. Fixtures shall be CE complianed. | BI01010001010000000000000515BI0100001183 | ||
| 73 | 29.1 | LED Street Light fixture 70 Watt | BI01010001010000000000000515BI0100001184 | 5 | Each |
| 74 | 30 | P & F of IP-65 protected high power LED flood light system with Pressure diecast aluminium housing , toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240 volt, 50Hz, of high power LED fixture supplied with pre wired cable of 1 mtr. Integrated driver shall be high efficiency having efficiency more than 85 % and in compliance to IEC standards/BIS certified. The System level Luminaire efficacy >=100 with High Power LEDs of CREE/NICHIA/OSRAM/PHILIPS/SEOUL make is to be used . LED Driver Input Voltage AC 110 to 270 V AC with Auto resetting Safety Cut-off. Input Frequency 50Hz±3% Power Factor >0.95 Driver Efficiency >85% ,Control Gear Integral Design, THD(I) <10% ,. Electrical Connector Must be provided Surge Protection Min >=5KV internal and 10KV external in 80W onwards,Humidity 10% to 90% RH Working Temp -20C to 50C . LED Luminaire Specifications: Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintenance.Manufactures Word Mark/Name Engraved/Embossed on die cast housing to allow traceability/authenticity till life of fixture. Fixtures shall be CE complianed. | BI01010001010000000000000515BI0100001185 | ||
| 75 | 30.1 | High Power LED Flood Light 120W | BI01010001010000000000000515BI0100001186 | 2 | Each |
| 76 | 31 | Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , Painting etc. as required. Group-1 | BI01010001010000000000000515BI0100001187 | 200 | Kg. |
| 77 | 32 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. | BI01010001010000000000000515BI0100001188 | ||
| 78 | 32.1 | M10 grade Nominal Mix \n1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). | BI01010001010000000000000515BI0100001189 | 5 | Cum. |
| 79 | 33 | Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding: | BI01010001010000000000000515BI0100001190 | ||
| 80 | 33.1 | New work (Two or more coats applied @ 3.84 kg/10 sqm). | BI01010001010000000000000515BI0100001191 | 50 | Sqm. |
AI Tender Summary
Tender Timeline
Jan 01, 2020
11:30 IST
Tender Published
Tender notice published.
CompletedJan 13, 2020
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJan 15, 2020
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender