Assam State Warehousing Corporation has published Renovation And Up Gradation Of Warehousing Facilities Under The Scheme Of Nabards Ridfxxi In Existing Hijuguri Warehousing Complex Dist Tinsukia Assam. Submission Date for this Tender is 18-01-2020. Storage and Warehousing Tenders in Amingaon Assam. Bidders can get complete Tender details and download the document.
Name of Work:- Renovation & up gradation of Warehousing facilities under the scheme of NABARDs RIDFXXI in existing HIJUGURI Warehousing Complex Dist Tinsukia Assam | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | RETROFITTING WORKS, | |||
2 | 2 | Chipping and breaking / cutting of loose concrete, mortars etc. using electrical chipping hammers to the satisfaction of the Engineer-in charge for successful execution of the subsequent rehabilitation works at all heights with all leads, lifts etc complete with all tools and machineries required for the job , operator, applicator, labour, scaffolding for staging and supervision etc. | item1 | 100 | M2 |
3 | 3 | Providing and applying two coats of NitozincPrimer a two component epoxy zinc rich primer/ sika top Aarmatec- 108 or equivalent product on the properly cleaned and prepared steel bars after the required chipping and cleaning of the concrete surface as per the manufacturer's specifications. | item2 | 100 | M2 |
4 | 4 | Before laying of the Micro Concrete, the substrate shall be coated with a bonding agent, Nitobond EP Std. / Sikadur -32 LP or equivalent product and the micro concrete shall be poured within 6 hrs/ 4 hrs or as applicable of the application of the bonding agent. | item3 | 10 | M2 |
5 | 5 | Providing and placing free flow micro concrete Renderoc RG / Sika Micro - concrete-2 or equivalent product of after fixing slurry tight shuttering. The micro concrete should be mixed mechanically while maintaining water, powder ratio of 0.16 strictly in accordance with the manufacturer's instructions and as per the direction of the Engineer- in -Charge.The micro concrete should develop a compressive strength of 10N/mm2 within 1 day, 40N/mm2 within 7 days and 50N/mm2 within 28 days.The cost is inclusive of materials, transportation, labour, taxes etc. all completre. | item4 | 1 | M3 |
6 | 6 | Drilling 12mm diax100 mm hole into the concrete surface using concrete hammer drill machine.Providing 10mm PGMS nozzles in a grid of 0.25m both and injecting with high strength cementitious grout- Cebex 100/ sika Intraplast EP or equivalent product till completion and refusal of grout complete as per manufacturer's specifications. The nozzles are to be sealed off after grouting using Renderoc Plug / Sika - 2 mortar or equivalent product injection with high strength cementitious grout-Cebex 100/ Sika intraplast EEP or equivalent product of Fosroc Complete as per the Specifications of the manufacturer. | item5 | 15 | each hole |
7 | 7 | Providing and applying two components epoxy resin based moisture intensive low viscous Sikadur-53 UF for high pressure injection grout with drilling & fixing of nozzle at 0.30 mt centre to centre as per manufacturer specification. The cost is inclusive of material, labour, tools & tackles etc all complete. | item6 | 15 | each hole |
8 | 8 | Crack openings should be chiselled out to approximately 20 mm x 20 mm , and should always be undercut to avoid formation of a" V" shape and cut back to a minimum depth of 15 mm and given a good mechanical key to apply Renderoc Plug / Sikadur-31 or equivalent product based per manufacture's specification. | item7 | 144 | RM |
9 | 9 | Providing and applying Nitobond SBR Latex / Ska Latex or equivalent priming coat followed by placement of renderoc S2/ sika top 122 or equivalent high build light weight polymer modified morter to give a composited thickness of 100. The Mortar should be mixed mechanically white maintaining water powder ratio strictly in accordance with the manufacturer's instructions and as per the direction of the Engineer-in-charge. The cost is inclusive of materials and application and exclusive of scaffolding | item8 | 67.549 | M2 |
10 | 10 | DISMANTLING AND DEMOLISHING | |||
11 | 11 | Demolishing RCC work including stacking of steel bars and disposal of unserviceable material as directed for all levels | item9 | 39.74 | M3 |
12 | 12 | Extra for cutting reinforcement in RCC or RB work at all levels (Payment to be made on cross sectional area of RCC or RB work obtained by multiplying the length of the cut reinforcement and thickness of the member). | item10 | 37.94 | M2 |
13 | 13 | Extra for scraping, cleaning and straightening reinforcement from RCC or RB work at all levels | item11 | 5000 | KG |
14 | 14 | Demolishing brickwork including stacking of serviceable materials and disposal of unserviceable materials as directed for all levels | item12 | 48.6 | M3 |
15 | 15 | Dismantling steel work in built up sections in joists, angles, channels, tees, flats etc. including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking the materials as directed by the Department for all levels | item13 | 1066.5 | KG |
16 | 16 | Dismantling all types of corrugated/ trapezoidal sheet roofing including ridges, hips, valleys and gutters etc. and stacking the materials as directed by the department for all levels | item14 | 2309.5 | M2 |
17 | 17 | Demolishing the plastering from walls/ R.C.C. and P.C.C. members without causing any damage to the wall/ member upto any height including disposal of debris as directed for all levels. | item15 | 6.45 | M3 |
18 | 18 | Demolishing CC floors of various thickness including top layer and base course and disposal of debris as directed for all levels. | item16 | 101.1 | M2 |
19 | 19 | Dismantling of existing steel windows/ steel ventilators/ steel windows and steel ventilators without damaging the walls, removing to a safe place and necessary repairs to the edges of walls. | item17 | 139.68 | M2 |
20 | 20 | EARTHWORK IN EXCAVATION | |||
21 | 21 | Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. | item18 | ||
22 | 22 | (A) Up to a depth of 2.00m below the existing ground level. | item19 | ||
23 | 23 | (a) In ordinary soil | item20 | 50.52 | M3 |
24 | 24 | CEMENT CONCRETE WORKS: | |||
25 | 25 | PLAIN CEMENT CONCRETE WORKS | |||
26 | 26 | Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). | item21 | ||
27 | 27 | (a) In prop 1cement: 3 sand :6 coarse aggregate by volume | item22 | 181.36 | M3 |
28 | 28 | (b) In prop 1cement: 4 sand :8 coarse aggregate by volume | item23 | 4.53 | M3 |
29 | 29 | Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) | item24 | ||
30 | 30 | (I) Using Mixer Machine | item25 | ||
31 | 31 | (A) In substructure up to plinth level | item26 | ||
32 | 32 | Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. | item27 | ||
33 | 33 | N) Without using admixture, plasticiser | item28 | ||
34 | 34 | b) M20 grade concrete or Prop. 1:1.5:3 | item29 | 14.94 | M3 |
35 | 35 | (B) In super structure from plinth level up to 1st floor level. | item30 | ||
36 | 36 | ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. | item31 | ||
37 | 37 | N) Without using admixture, plasticiser | item32 | ||
38 | 38 | b) M20 grade concrete or Prop. 1:1.5:3 | item33 | 41.14 | M3 |
39 | 39 | SHUTTERING & FORM WORK | |||
40 | 40 | TIMBER SHUTTERING ( FORM WORK) | |||
41 | 41 | Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: | item34 | ||
42 | 42 | Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. | item35 | ||
43 | 43 | (b) Using 25mm thick plank | item36 | 44.8 | M2 |
44 | 44 | Sides of tie beams, grade beams etc. at or below ground level. | item37 | ||
45 | 45 | (b) Using 25mm thick plank | item38 | 36 | M2 |
46 | 46 | Columns, Pillars, Posts & Strut | item39 | ||
47 | 47 | (a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face | item40 | ||
48 | 48 | (ii) Using 25mm thick plank | item41 | 339.02 | M2 |
49 | 49 | Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. | item42 | ||
50 | 50 | (a) For depth not exceeding 1.0M. | item43 | ||
51 | 51 | (ii) Using 25mm thick plank | item44 | 184 | M2 |
52 | 52 | BRICK WORKS ( CONVENTIONAL / FLY ASH ) | |||
53 | 53 | Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. | item45 | ||
54 | 54 | (c).Stone soling of thickness 150mm. | item46 | 48.84 | M2 |
55 | 55 | Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. | item47 | ||
56 | 56 | (II) In superstructure above plinth level up to 1st floor level. | item48 | ||
57 | 57 | (b) In proportion 1:4.(1 cement:4 sand) | item49 | 34.4 | M3 |
58 | 58 | 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) | item50 | ||
59 | 59 | (A) 112mm thick brick wall | item51 | ||
60 | 60 | (a) In cement mortar in proportion 1:4. | item52 | 622.8 | M2 |
61 | 61 | CEMENT PLASTERING | |||
62 | 62 | 10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed | item53 | ||
63 | 63 | b) In cement mortar 1:4 | item54 | 854.796 | M2 |
64 | 64 | 15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. | item55 | ||
65 | 65 | A) On rough side | item56 | ||
66 | 66 | b) In cement mortar 1:4 | item57 | 828 | M2 |
67 | 67 | Extra over item no 6.2.1 to 6.2.3 for providing and mixing water proofing materials in cement mortar in prop as recommended by the manufacturer including curing complete as directed. | item59 | ||
68 | 68 | i) 10 mm thick plaster | item60 | ||
69 | 69 | b) In cement mortar 1:4 | item61 | 112.8 | M2 |
70 | 70 | ii) 15 mm thick plaster | item62 | ||
71 | 71 | b) In cement mortar 1:4 | item63 | 86 | M2 |
72 | 72 | Providing Pre Painted Galvanized Iron Sheet Roofing (PPGI) at all levels including fitting and fixing with self drilling, self tapping screws complete. (Roof trusses, purlins etc. to be measured and paid separately.) \nTATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement | item68 | ||
73 | 73 | (iii) 0.50 mm thick | item69 | 2304 | M2 |
74 | 74 | Providing Pre Painted Galvanized Iron Sheet (PPGI) accessories (Ridges / Valley / Gutter /Flashing) at all levels including fitting and fixing self drilling, self tapping screws complete complete.\nTATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement | item70 | ||
75 | 75 | (iii) 0.50 mm thick | item71 | 82 | RM |
76 | 76 | BARGE BOARD | |||
77 | 77 | Providing barge board of size 200mm x 20mm with 1st class local Hollock/ Bonsum timber including fitting and fixing with necessary wood screws etc. complete. | item72 | 165 | M3 |
78 | 78 | CEMENT PAINT & PRIMER | |||
79 | 79 | a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth. | item73 | 4995.65 | M2 |
80 | 80 | b) Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on new wall surface (two coats) to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials. | item74 | 2232 | M2 |
81 | 81 | PAINTING ON STEEL AND OTHER METAL SURFACE | |||
82 | 82 | Synthetic enamel paint, aluminium paint / bituminus paint on steel and other metal surfeces.\ni).Removing old paint from steel and other metal surface and making the surface even. | item75 | ||
83 | 83 | a). With hand scraping | item76 | 3620.92 | M2 |
84 | 84 | Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. | item77 | ||
85 | 85 | a). With ready mixed "red-lead/ red oxide" primer. | item78 | 3620.92 | M2 |
86 | 86 | Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. | item79 | ||
87 | 87 | (i).Surfaces over 100mm in width or girth. | item80 | ||
88 | 88 | a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac). | item81 | 3620.92 | M2 |
89 | 89 | Finishing old/new wall with water proofing weather coat smooth anti-fungal exterior painting of approved make of Dulux (ICI) paint of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats) | item82 | 2686.65 | M2 |
90 | 90 | REINFORCEMENT | |||
91 | 91 | Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.\n(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) | item83 | ||
92 | 92 | a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL | item84 | ||
93 | 93 | (i) TMT Corrosion resistant steel (CRS) reiforcement bar | item85 | 5.93 | QTL |
94 | 94 | (ii)Super Ductile (SD) TMT reinforcement bars | item86 | 43.47 | QTL |
95 | 95 | Providing and fixing rolling shutters of approved make made of 80mm wide M.S. laths interlocked together through their entire lenth and jointed together at the ends by end-locks mounted on specially designed pipe shaft with bracket plates, guide channels and arrangements for inside and outside locking with push-pull operation complete including cost of wire, spring and hood cover for the shutters. | item87 | 55 | M2 |
96 | 96 | ROOF TRUSS | |||
97 | 97 | Providing fitting, hoisting and fixing of roof trusses including purlins fabricated using MS circular hollow section conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed. | item88 | ||
98 | 98 | a) TATA make Circular Hollow section- CHS of Grade YST-310 conforming to I.S. Specification : 1161-1998 | item89 | 5 | QTL |
99 | 99 | PRE CONSTRUCTION ANTI - TERMITE TREATMENT | |||
100 | 100 | Pre construction anti - termite treatment at the bottom of foundation pits and walls on either side up to a height of 300mm from bottom of the excavation made for column plinth beam, wall, trenches etc. by applying the emulsion @ 5 (five) litres per square meter of the surface area before starting construction work (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. | item90 | ||
101 | 101 | a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution. | item91 | 177 | M2 |
102 | 102 | PVC PIPES,BENDS,JUNCTIONS,TEES ETC. | |||
103 | 103 | Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. | item92 | ||
104 | 104 | a) In exposed surfaces or in trenches. | item93 | ||
105 | 105 | (iv) 75mm dia. | item94 | 20 | RM |
106 | 106 | turbo ventilator | item95 | 18 | EACH |
107 | 107 | ELECTRICLE | |||
108 | 108 | Wiring in surface/ recessed ISI marked Steel conduit pipe FR.(Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) cable | item96 | ||
109 | 109 | Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia rigid ISI marked Steel conduit pipe (AKG or equivalent as approved by the Deptt.) including 6 amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete | item97 | ||
110 | 110 | Medium point up to 6.00 metre. Length. | item98 | 125 | EACH |
111 | 111 | long point up to 10.0 metre. Length. | item99 | 75 | EACH |
112 | 112 | Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed ISI marked Steel conduit pipe (AKG or equivalent as approved by the Deptt.) wiring system including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. marked) with phenolic laminated sheet cover including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete, when placed elsewhere. | item100 | ||
113 | 113 | Short point up to 3.00 metre. length. | item101 | 15 | EACH |
114 | 114 | Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed ISI marked Steel conduit pipe wiring system. | item102 | ||
115 | 115 | With 3 x 1.5 sq. mm. cable in 20 mm dia. rigid Steel conduit. | item103 | 750 | Metre |
116 | 116 | Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) including earth continuity in surface/ recessed ISI marked Steel conduit pipe wiring system . | item104 | ||
117 | 117 | With 3 x 4 sq. mm. + earth continuity with 2x 2.5 sq. mm. cable in 25 mm. dia. rigid Steel conduit. | item105 | 15 | Metre |
118 | 118 | FITING AND ACCESSORIES | |||
119 | 119 | Supplying and fixing of bulk head fitting suitable for CFL lamp complete with all accessories including 20 watts CFL lamp and connection as approved by the Deptt.)as required. | item106 | 8 | EACH |
120 | 120 | Supplying and fixing of 3 plate Ceiling Rose (Anchor Penta PC CHERRY /Gold medal /Kolor kany.kom/Havells or equivalent make as approved by the Deptt.) on the existing block including connection as approved by the Deptt.)complete as required | item107 | 40 | EACH |
121 | 121 | LUMINARIES | |||
122 | 122 | Supplying with fitting fixing of CFL/Fluorescent luminaries complete with all accessories such as ballast, starter etc. directly on wall / ceiling including connection as approved by the Deptt.)with 1.5 sq mm P.V.C. insulated S.C. copper conductor as required and as directed by the department. | item108 | 8 | EACH |
123 | 123 | Sleek Box type luminaries complete with Electronic ballast and plastic holder brackets/ top cover & decorative dual colour end caps with 1 X 36 / 40 watt Fluorescent tube.(Crompton Greaves make) Model- DJB 1314LDB50 / DJBN1314EB CROMTEK with Power Lux Lamp/ DMLUN36EB MIRRORLITE ULTRA SLIM with Super Saver Lamp or equivalent (Equivalent will be selected by the deptt considering the mother items rate) PHILIPS/ WIPRO/ BAJAJ/ Havells/ HPL/ SOLAR/ JAQUAR make. [FL] | item109 | 180 | EACH |
124 | 124 | MCB DB (ABB, SCHNEIDER MG, LEGRAND, HAGER MAKE) & (SCHNEIDER NEO BREAK, C&S, Havells, INDOASIAN, HPL OR EQUIVALENT MAKE AS PPROVED BY THE DEPTT.) | item110 | ||
125 | 125 | MCB IN-comer SPN DB | item111 | ||
126 | 126 | Supplying with fitting and fixing sheet steel, phosphatised, powder painted Single door surface mounting MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. | item112 | ||
127 | 127 | ABB, Schneider MG, legrand, Hager make) | item113 | ||
128 | 128 | 6 way TPN (4+18) single door | item114 | 2 | EACH |
129 | 129 | PART - 16 | item115 | ||
130 | 130 | MCB, MCCB, RCCB, RCBO (ABB, SCHNEIDER MG, LEGRAND, AND HAGER MAKE) & (SCHNEIDER NEO BREAK, C&S, Havells, INDO ASIAN, HPL OR EQUIVALENT MAKE AS PPROVED BY THE DEPTT.) MCB (Conform to IS / IEC 60898-1:200/ MCCB (Conform to IS/IEC 60947- RCCB (Conform to IS/IEC 12640 / 61008) | item116 | ||
131 | 131 | Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. | item117 | ||
132 | 132 | B Series\n(Schneider MG, legrand, Hager make) | item118 | ||
133 | 133 | 6 to 32A | item119 | 24 | EACH |
134 | 134 | Supplying with fitting and fixing TP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. | item120 | ||
135 | 135 | B Series\n(Schneider MG, legrand, Hager Crabtree xpro make) | item121 | ||
136 | 136 | 40A | item122 | 1 | EACH |
137 | 137 | Supply, installation & testing of G.I. earth station with perforated 50 mm dia and 3.00 Metre long heady duty G.I. pipe with necessary 50 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 65 mmx50 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt . | item125 | 2 | EACH |
138 | 138 | Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt. | item126 | 2 | EACH |
139 | 139 | Supplying & laying of 8 SWG G.I. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt. | item127 | 80 | EACH |
140 | 140 | Repairing brick wall with cement concrete ( 1:2:4 ) of thickness varing from 25mm to 100 mm after cleaning of the surface of the brick wall applying bonding agent Nitobond EP Std./Sikadur-32 LP or equivalent product to cover up the damaged portion of existing brick wall including fixing of chicken wire netin position to hold the c.concrete if necessary. Finished and complete as per direction of Engineer in Charge. | item128 | 30 | M2 |
141 | 141 | Providing VDF flooring for top coat of floor (75mm0 with dewatering of concrete by vaccum pump and sprinkling non metallic hardener @ 5 Kg/sqm folowed by a coat of cement slurry mixed with Nitobond SBR latex or equivalent @ 50 Kg cement and 10lit Nitobond SBR Latex before laying the concrete 1:3:6 over the levelling CC base 1:3:6. 10mmX12mm groove @ 5.00 M or equally distributed pattern to be cutted and filled with appropriate grouting compound. Complete and finished in all respect as per company specification and Engineer in charge. | item129 | 1960 | M2 |
142 | 142 | Louvre for Air inlet | item130 | 10 | NOS |
143 | 143 | BARGE BOARD | item131 | 50 | RM |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy