| 1 | 1 | Taking down carefully existing unserviceable aluminum point wiring of any description & in any position with and including existing wooden battens/conduits fixed on surface or conceled and all fittings including sunken/surface boxes & terminal boxes of any description, accessories & fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings, lamp holders etc including sunken boxes / junction boxes and making good the disturbed surface of walls, floors, ceiling etc. to match with the existing surfaces complete all as specified and directed. | | 325 | Each point |
|---|
| 2 | 2 | Taking down carefully existing unserviceable aluminum point wiring of any descreption & in any position from existing conduits fixed on surface or concealed including accessories & fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings, lamp holders etc and making good the disturbed surface of walls, floors, ceiling etc. to match with the existing surfaces complete all as specified and directed. | | 150 | Each point |
|---|
| 3 | 3 | Material and labour for point wiring for one light point or one fan point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, PVC insulated & unsheathed cable, 1100 volts grade in and including concealed PVC conduits (Medium grade) of size not less than 20 mm dia all as directed with sunken type pressed steel terminal box and junction boxes 1.6mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings and wiring to be terminated in pressed steel sunken boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed. \nNOTE :- (i) Quoted rate shall be deemed to include the cost of cutting chases in walls / pillars /column etc. of any description for concealing the conduit to required depth & making good the disturbed surface in CM 1:4 including finishing the surface to match with the existing surface. The portion of point wiring at ceiling shall be in surface PVC conduit/ casing & caping of suitable size fixed on ceiling surface with using PVC rawl plugs.\n(ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A'.\n(iii) The quoted rates shall be deemed to be inclusive for provision of covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thick laminated sheet fixed with suitable brass screws and cup washers | | 130 | Each point |
|---|
| 4 | 4 | Description same as per Srl item No 2 above but, point wiring for 5 pin switch socket outlet combination, 5/6 Amps on independent board.---ditto--- | | 35 | Each point |
|---|
| 5 | 5 | Description same as per Srl item No 2 above but, point wiring for 5 pin socket outlet, 5/6 Amps on same board. ----ditto--- | | 15 | Each point |
|---|
| 6 | 6 | Description same as per Srl item No 2 above but, point wiring for one six pin switch socket outlet combination, 15 Amps & 5 Amp (independent) with using 2.5 Sqmm (nominal area) stranded copper conductor and 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete -ditto- | | 35 | Each Point |
|---|
| 7 | 7 | Material and labour for point wiring for one light point or one fan point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, PVC insulated & unsheathed cable, 1100 volts grade in existing conduit as directed with using old existing sunken type pressed steel box / cast iron switch boards/terminal boxes for mounting fittings/junction boxes and wiring to be terminated in existing sunken boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed.\nNOTES : (i) The quoted rates shall be deemed to be inclusive for provision of covering existing sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thick laminated sheet fixed with suitable brass screws and cup washers. \n(ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A' \n(iii) Quoted rate shall be deemed to include the cost of making good the disturbed surface in CM 1:4 including finishing the surface to match with the existing surface. | | 85 | Each point |
|---|
| 8 | 8 | Description same as per Srl item No 6 above but, point wiring for 5 pin switch socket outlet combination, 5/6 Amps on independent board complete all as specified and directed. | | 25 | Each point |
|---|
| 9 | 9 | Description same as per Srl item No 6 above but, point wiring for 5 pin socket outlet, 5/6 Amps on same board complete all as specified and directed. | | 15 | Each point |
|---|
| 10 | 10 | Description same as per Srl item No 6 above but point wiring for one six pin switch socket outlet combination, 15 Amps & 5Amp (independent) with using 2.5 Sqmm (nominal area) stranded copper conductor complete all as specified and directed. | | 25 | Each point |
|---|
| 11 | 11 | Material and labour for point wiring for one light point or one fan point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, PVC insulated & unsheathed cable, 1100 volts grade in surface PVC casing and caping of suitable size all as directed with sunken type pressed steel terminal box 1.6mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings/junction boxes and wiring to be terminated in pressed steel sunken boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed. \nNOTE :- (i) Quoted rate shall be deemed to include the cost of making good the disturbed surface in CM 1:4 including finishing the surface to match with the existing surface. \n(ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A'.\n(iii) The quoted rates shall be deemed to be inclusive for provision of covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thick laminated sheet fixed with suitable brass screws and cup washers | | 45 | Each Point |
|---|
| 12 | 12 | Description same as per Srl item No 10 above but, point wiring for 5 pin socket outlet, 5 Amps on same board with other switches.complete all as specified and directed. | | 15 | Each Point |
|---|
| 13 | 13 | Description same as per Srl item No10 above but, point wiring for 5 pin switch socket outlet combination, 5 Amps on independent board complete all as specified and directed. | | 25 | Each Point |
|---|
| 14 | 14 | Description as per Srl item No 10 above but, point wiring for one six pin switch socket outlet combination, 15 Amps & 5Amp (independent) with using 2.5 Sqmm (nominal area) stranded copper conductor complete all as specified and directed. | | 25 | Each Point |
|---|
| 15 | 15 | Supplying & fixing for switch socket outlet combination, five pin, 5 Amps, flush type, 230 volts AC circuit complete all as specified and directed.\nMake: Anchor/Cona/ Leader | | 85 | Each |
|---|
| 16 | 16 | Supplying & fixing for socket outlet, five pin 2-1, 5 Amps, flush type, 230 volts AC circuit complete all as specified and directed.\nMake: Anchor/Cona/ Leader | | 45 | Each |
|---|
| 17 | 17 | Supplying & fixing for switch socket outlet combination, multipurpose, three pin, 15 Amps & three pin 5 Amps controlled by one switch , flush type, 230 volts AC circuit complete all as specified and directed.\nMake: Anchor/Cona/ Leader | | 85 | Each |
|---|
| 18 | 18 | Supplying & fixing for ceiling rose surface bakelite 63.5 x 20 mm, three terminals, complete all as specified and directed.\nMake: Anchor/Cona/ Leader | | 214 | Each |
|---|
| 19 | 19 | Supplying & fixing for switch flush type, 5/6 Amps, single pole, one way, 230 volts AC circuit complete all as specified and directed. \nMake: Anchor/Cona/ Leader | | 305 | Each |
|---|
| 20 | 20 | Supplying & fixing for lamp holder, insulated body with back plate suitable for angular fitting complete with & including one No. CFL 15 Watt 6500 K complete all as specified and directed.\nMake: Anchor/Cona/ Leader | | 30 | EACH JOB |
|---|
| 21 | 21 | M&L for sub main wiring in repair using two single core PVC insulated, unsheathed stranded copper conductor cable of size 4 Sqmm of voltage rating 1100 Volts drawn in and including surface PVC conduit of dia not less than 20mm/ casing caping with standard accessories, along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 2.5 Sqmm as earth continuity conductor all as specified and directed. \nNOTE: Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit. | | 250 | RM |
|---|
| 22 | 22 | Description as per item No 21 above but cable of size 6 Sqmm with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 6 Sqmm as earth continuity conductor all as specified and directed.\nNote : Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit | | 200 | RM |
|---|
| 23 | 23 | M&L for sub main wiring in repair using two single core PVC insulated, unsheathed stranded copper conductor cable of size 6 Sqmm of voltage rating upto and including 1100 Volts drawn in existing conduit along-with one run of PVC (Green colour) insulated , unsheathed, stranded copper conductor of size 6 Sqmm as earth continuity conductor all as specified and directed.\nNote:- Two run of single core PVC cable with one run of earth conductor shall be measured as one unit | | 200 | RM |
|---|
| 24 | 24 | M&L for sub main wiring in repair using four single core PVC insulated, unsheathed stranded copper conductor cable of size 10 Sqmm of voltage rating upto and including 1100 Volts drawn in recessed PVC conduit of dia not less than 32mm with standard accessories, along-with two run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 6 Sqmm as earth continuity conductor all as specified and directed. \nNOTE:- Four run of single core PVC cable with two run of earth conductor and conduit shall be measured as one unit. | | 150 | RM |
|---|
| 25 | 25 | Supplying & fixing in replacement LED batten for surface and pendant applications .Anozied extruded aluminium housing high transmissitivity diffuser .High lumen output fitting 20 watt and including all accessories, pre-wired and connecting the same to ceiling rose with & including three core PVC insulated and sheathed copper conductor 1.5 sqmm cable including all accessories and fixing arrangement for fixing the light fitting to walls / roof surface complete all as specified and directed. Make :- Bajaj Cat No BCLAB 20 Watt LED/Havell/CG. | | 100 | EACH |
|---|
| 26 | 26 | Supplying & fixing in repair wall / surface mounting type bulk head LED luminaries 10 watt LED comprising of deep drawn anodized aluminium body, epoxy white powder coated, complete with accessories on a detachable tray and covered with heat resistant prismatic glass cover with weather proof gasket complete all as specified and directed. \nMake :- Bajaj Cat Part No- BIBWP 10W LED /Havell/CG | | 25 | Each |
|---|
| 27 | 27 | S&F in repair LED roadway luminaries 60 Watt LED, pressure die cast aluminium housing LED street light luminaries with IP66 protection and accessories including GI light grade tube bracket of required shape & size, and connecting the same to electric source with using copper conductor 0.5 sqmm flexible twisted three core cable , including all accessories and fixing arrangements for fixing the light fitting to walls / pillars complete all as specified and directed.\nMake :- Bajaj Cat Part No- BRTFG 60W LED /Havells/ CG/C&S | | 90 | Each |
|---|
| 28 | 28 | Supplying and fixing in repair industrial type socket & plug top with and including sheet metal enclosure 20 amp SP, MCB ‘C’ series 10KA complete all as directed and specified. \nMake:- Legrand /Havells/C&S | | 4 | Each |
|---|
| 29 | 29 | Supply, fixing, connecting & testing in repair sheet metal enclosures double door, triple pole and neutral, 4 way DBs for using MCBs / MCB isolators with having aluminium bus bars suitable for 200 Amps rating complete all as specified and directed.\nMake :-Legrand /Havells/ C&S \n | | 4 | EACH |
|---|
| 30 | 30 | Supply, fixing, connecting & testing in repair sheet metal enclosures double door, single pole and neutral, 12 way DBs for using MCBs / MCB isolators with having aluminium bus bars suitable for 200 Amps rating complete all as specified and directed.\nMake :-Legrand /Havells/ C&S \n | | 3 | EACH |
|---|
| 31 | 31 | Supply, fixing, connecting & testing in repair sheet metal enclosures double door, single pole and neutral, 8 way DBs for using MCBs / MCB isolators with having aluminium bus bars suitable for 200 Amps rating complete all as specified and directed.\nMake :-Legrand /Havells /C&S \n | | 15 | EACH |
|---|
| 32 | 32 | Description same all as per Item No 36 above but, MCB DB suitable for single pole & neutral, 4 way complete all as specified and directed.\nMake :-Legrand /Havells/ C&S \n | | 10 | EACH |
|---|
| 33 | 33 | Supplying & fixing in repair MCB FP, 63 Amps (`C’ series) having current rating 10 KA complete all as specified and directed.\nMake :- Legrand /Havell/C&S. | | 4 | EACH |
|---|
| 34 | 34 | Supplying & fixing in repair MCB SPN, 32 Amps (`C’ series) having current rating 10 KA complete all as specified and directed.\nMake :- Legrand /Havell/C&S. | | 28 | EACH |
|---|
| 35 | 35 | Supplying & fixing in repair MCB single pole, 6 to 32 Amps (`C’ series) having current rating 10 KA complete all as specified and directed.\nMake :- Legrand /Havell/C&S. | | 188 | EACH |
|---|
| 36 | 36 | Supplying & fixing in repair Racessed mounted Adjustable downlight for Accent lighting LED light 6Watt white powder coated recessed mounted fixture pressure die cast aluminium housing with high efficiency reflactor spring loaded mounting brackets for ease of installation complete all as specified and directed. \nMake :- Bajaj Cat Part No-BGSLO Sleeek 6W WH RD/Havells/CG. | | 20 | EACH |
|---|
| 37 | 37 | Supplying & fixing in repair Mirror optics light LED light Watt white powder coated recessed mounted fixture pressure die cast aluminium housing with high efficiency reflactor spring loaded mounting brackets for ease of installation complete all as specified and directed. \nMake :- Bajaj Cat Part No- BCLSB 5W LED /Havells/ CG. | | 15 | EACH |
|---|
| 38 | 38 | Supplying, fixing in repair & testing 50watt LED flood light with high pressure die cast housing with IP65 and including copper conductor 23/0.0076 flexible twisted twin core cable , including all accessories and fixing arrangements for fixing the light fitting to false ceiling complete all as specified and directed.\nMake :Bajaj cat part No BJFL 50W LED /Havells/CG | | 20 | Each |
|---|
| 39 | 39 | Supply and fixing in repair fan regulator electronic, step type, suitable for ceiling fans of any capacity, pre-wired 230 volts AC 50Hz supply 100Watt complete all as specified and directed by Engineer-in-Charge. \nMake:Anchor /Cona /Leasder. | | 15 | EACH |
|---|
| 40 | 40 | Supply and fixing in repair Exhaust fan 450mm sweep iron body with louvsrs and including copper conductor 23/0.0076 flexible twisted twin core cable , including all accessories and fixing arrangements for fixing the light fitting to false ceiling complete all as specified and directed.\nMake:Havells/ Bajaj/ GEC or equivalent others make as specified. | | 2 | EACH |
|---|
| 41 | 41 | Supplying and laying testing & commissioning in repair LT cable PVC insulated, PVC inner sheathing, electric power cables (heavy duty) with copper conductor 1100 volt grade of 2.5 Sqmm 2 core size fixed to walls/ steel trusses/drawn in conduit/laid in floor complete all as specified and directed. | | 150 | RM |
|---|
| 42 | 42 | Supplying and laying testing and commissioning in repair LT cable XLPE insulated armoured, heavy duty, aluminium conductor cable 25 Sqmm 3.5 core, 1100 volt grade,on wall,flor,roof with clamps and saddles complete all as specified and directed. | | 200 | RM |
|---|
| 43 | 43 | Supplying and laying testing and commissioning in repair LT cable XLPE insulated armoured, heavy duty, aluminium conductor cable 10 Sqmm 2 core, on wall,flor,roof with clamps and saddles 1100 volt grade complete all as specified and directed. | | 200 | RM |
|---|
| 44 | 44 | Supplying & fixing in repair Integral LED Post Top Lantern 70 watt LED and accessories fixing to electric source complete and fixing GI pipe of suitable length grouting in PCC complete all as specified and directed at site.\nMake: Bajaj Cat Part No - BGCL 70W LED /Havells/CG. | | 15 | Each |
|---|
| 45 | 45 | Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI wire 4 mm dia main earthing lead by means of galvanized bolts, nuts and washers all as shown in electrical plate no 3 of MES Schedule Part-I, earth lead connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt alround earth plate, PCC 1:3:6 type C-1 using 20mm graded black trap/granite/Basalt stone aggregate for earth pit with pre cast RCC 1:2:4 type B-1 using 20mm graded black trap/granite/Basalt stone aggregate, 40mm thick cover reinforced with 8mm dia TMT bars 3 Nos both way with 08mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh, complete all as specified and directed. \n\n | | 6 | Each Job |
|---|
| 46 | 46 | S & F earth wire GI wire 4 mm dia as earth continuty conductor all as specified and directed | | 80 | RM |
|---|
| 47 | 47 | Supply and fixing / laying pipe, GI medium grade 40 mm bore fixed on walls or laid under floor complete all as specified & directed. | | 20 | RM |
|---|
| 48 | 48 | Supply, laying and connecting 15mm bore galvanized iron medium grade pipe fixed on walls or laid under floor complete all as specified and directed | | 15 | RM |
|---|
| 49 | 49 | Excavation in trenches in soft/loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out including forming bottom surface to required slope/gradient for laying cables/pipes etc. complete all as specified and directed | | 135 | Cum |
|---|
| 50 | 50 | Returning, filling in including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed and tested complete all as specified and directed. | | 110 | Cum |
|---|
| 51 | 51 | Removal of surplus excavated spoil not exceeding 50 Mtr distance and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. | | 25 | Cum |
|---|
| 52 | 52 | Material and labour for sand filling with clean dry sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed. | | 41 | Cum |
|---|
| 53 | 53 | Supplying & Laying Sub Class `B’ bricks old size with axis of the bricks perpendicular to the axis of the cable as in cable protection complete all as specified and directed. | | 4.3 | Per 1000 Nos |
|---|
| 54 | 54 | S&F in replacement LED bollard light with Opel acrylic diffuser and IP-65 protection including necessary concreat work complete all as specified and directed Make :- Bajaj cat part No BGBOM 650 9WLED /CG/Havells | | 20 | Each |
|---|