}

Procurement Of Led Lams And Fittings - 1 Led Tube As Retrofit For Ordinary 4 Feet ( 1200 Mm ) 40 / 36 W Fitting Nwith The Following Specifications: N Nworking Voltage : 120 - 270 V Ac, 50 Hz Npower Consumption : 22 W ( Maximum ) Noutput Lumen : 1, 400 Lm ( Minimum ) Npower Factor : 0.9 ( Minimum ) Ncolour Temperature : 4, 000 - 5, 500 Degree Kelvin 2 Hand Lamp, 24V, 12W, Led Nnominal Power Consumption : 12W Nled Color : Warm White Nsupply Voltage : 24 V Ac Noperating Temperature : Up To 60°C Nworking Humidity : 95% Nenclosure : Die Cast Aluminum With Acrylic Cover N N 3 Flood Light Fitting With High Power Led Cluster Flood Light Fitting With Nhigh Power Led Cluster Lamps Conforming To Iec60598. Nwattage : 30 + / - 10 W Ninput Supply : 230V + / - 5%, 50Hz Ncolor Temperature : Cool White ( 5700K ) Nlumen Output : > 70 Lm / W Ndegree Of Protection : Ip65 Npower Factor : >0.95Pf Nefficiency : >90% Including Driver Nenclos, UDYOGAMANDAL-Kerala

Fertilisers And Chemicals Travancore Limited has published Procurement Of Led Lams And Fittings - 1 Led Tube As Retrofit For Ordinary 4 Feet ( 1200 Mm ) 40 / 36 W Fitting Nwith The Following Specifications: N Nworking Voltage : 120 - 270 V Ac, 50 Hz Npower Consumption : 22 W ( Maximum ) Noutput Lumen : 1, 400 Lm ( Minimum ) Npower Factor : 0.9 ( Minimum ) Ncolour Temperature : 4, 000 - 5, 500 Degree Kelvin 2 Hand Lamp, 24V, 12W, Led Nnominal Power Consumption : 12W Nled Color : Warm White Nsupply Voltage : 24 V Ac Noperating Temperature : Up To 60°C Nworking Humidity : 95% Nenclosure : Die Cast Aluminum With Acrylic Cover N N 3 Flood Light Fitting With High Power Led Cluster Flood Light Fitting With Nhigh Power Led Cluster Lamps Conforming To Iec60598. Nwattage : 30 + / - 10 W Ninput Supply : 230V + / - 5%, 50Hz Ncolor Temperature : Cool White ( 5700K ) Nlumen Output : > 70 Lm / W Ndegree Of Protection : Ip65 Npower Factor : >0.95Pf Nefficiency : >90% Including Driver Nenclos. Submission Date for this Tender is 08-01-2020. Halogen Light Tenders in UDYOGAMANDAL Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

23083011
Procurement Of Led Lams And Fittings - 1 Led Tube As Retrofit For Ordinary 4 Feet ( 1200 Mm ) 40 / 36 W Fitting Nwith The Following Specifications: N Nworking Voltage : 120 - 270 V Ac, 50 Hz Npower Consumption : 22 W ( Maximum ) Noutput Lumen : 1, 400 Lm ( Minimum ) Npower Factor : 0.9 ( Minimum ) Ncolour Temperature : 4, 000 - 5, 500 Degree Kelvin 2 Hand Lamp, 24V, 12W, Led Nnominal Power Consumption : 12W Nled Color : Warm White Nsupply Voltage : 24 V Ac Noperating Temperature : Up To 60°C Nworking Humidity : 95% Nenclosure : Die Cast Aluminum With Acrylic Cover N N 3 Flood Light Fitting With High Power Led Cluster Flood Light Fitting With Nhigh Power Led Cluster Lamps Conforming To Iec60598. Nwattage : 30 + / - 10 W Ninput Supply : 230V + / - 5%, 50Hz Ncolor Temperature : Cool White ( 5700K ) Nlumen Output : > 70 Lm / W Ndegree Of Protection : Ip65 Npower Factor : >0.95Pf Nefficiency : >90% Including Driver Nenclos
Open Tender
Indian
Kerala
Udyogamandal
08-01-2020

Tender Details

Corrigendum - Procurement Of Led Lams And Fittings - 1 Led Tube As Retrofit For Ordinary 4 Feet ( 1200 Mm ) 40 / 36 W Fitting Nwith The Following Specifications: N Nworking Voltage : 120 - 270 V Ac, 50 Hz Npower Consumption : 22 W ( Maximum ) Noutput Lumen : 1, 400 Lm ( Minimum ) Npower Factor : 0.9 ( Minimum ) Ncolour Temperature : 4, 000 - 5, 500 Degree Kelvin 2 Hand Lamp, 24V, 12W, Led Nnominal Power Consumption : 12W Nled Color : Warm White Nsupply Voltage : 24 V Ac Noperating Temperature : Up To 60°C Nworking Humidity : 95% Nenclosure : Die Cast Aluminum With Acrylic Cover N N 3 Flood Light Fitting With High Power Led Cluster Flood Light Fitting With Nhigh Power Led Cluster Lamps Conforming To Iec60598. Nwattage : 30 + / - 10 W Ninput Supply : 230V + / - 5%, 50Hz Ncolor Temperature : Cool White ( 5700K ) Nlumen Output : > 70 Lm / W Ndegree Of Protection : Ip65 Npower Factor : >0.95Pf Nefficiency : >90% Including Driver Nenclosure Type : Industrial Standard Powder Coated Aluminium Alloy Ncasting N Nmounting : C Clamp Mounted With Suitable Up / Down Nadjustments Nleds Shall Have A Minimum Lifetime Of 50000 Hrs And Shall Be Of Reputed Nmake. N 4 Flood Light Led Fitting With High Power Led Cluster Nconforming To Iec60598. Nwattage : 30W ( Minimum ) Ninput Supply : 24V + / - 5%, 50Hz Ncolor Temperature : Cool White ( 5700K ) Nlumen Output : > 70 Lm / W Ndegree Of Protection : Ip65 Npower Factor : >0.9Pf Nenclosure Type : Industrial Standard Powder Coated Aluminium Alloy Ncasting Nmounting : C Clamp Mounted With Suitable Up / Down Nadjustments Nleds Shall Have A Minimum Lifetime Of 50000 Hrs And Shall Be Of Reputed Nmake. N N 5 Flood Light Fitting With High Power Led Cluster Lamps Conforming Nto Iec 60598. N Nwattage : 25 + / - 2.5 W Ninput Supply : 230V+ / -5%, 50Hz Ncolor Temperature : Cool White ( 5700K ) Nlumen Output : >70 Lm / W Ndegree Of Protection : Ip65 Npower Factor : >0.9 Nefficiency : >90% Including Driver Unit Nenclosure Type : Industrial Standard Powder Coated Aluminium Alloy Nmounting : C Clamp Mounted With Suitable Up / Down Nadjustments N 6 Led Lamp As Retrofit For Incandescent Lamp, Suitable For Working On 230 Nv, 50 Hz Ac Supply, As Per Is 16101 To 16108 ( Or Equivalent Iec Nstandards As Applicable ) With Latest Amendments N Npower Consumption Of 14 W ( Maximum ) And Output Lumen Of 1, 100 Lm N ( Minimum ) . Cap Size: B22-D2 7 Led Lamp As Retrofit For Incandescent Lamp, Suitable For Working On 230 Nv, 50 Hz Ac Supply, As Per Is 16101 To 16108 ( Or Equivalent Iec Nstandards As Applicable ) With Latest Amendments N Npower Consumption Of 14 W ( Maximum ) And Output Lumen Of 1, 100 Lm N ( Minimum ) . Cap Size: E27 8 4 Ft Led Batten Light Fixture With Intgral Drive And Lamp With All Naccessories Suitable For Surface Mounting With The Following Nspecifications: Nworking Voltage : 220 - 240 V Ac, 50 Hz Npower : 20 W Noutput Lumen : 90 Lumen Per Watt ( Minimum ) Ncolour : Cool Day Light N

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail