| 1 | 1 | Supply, Fixing & Testing of multistage submersible pump set of 30 HP motor capacity having water discharge 7700 GHP @ 120 Mtr head, complete all as specified and directed by Engineer-in-Charge.\nMake :- Kirloskar / Mather & Platt / CRI / Crompton\n | | 1 | Each |
|---|
| 2 | 2 | Supply, Fixing & Testing of multistage submersible pump set of 20 HP motor capacity having water discharge 7000 GHP @ 110 Mtr head, complete all as specified and directed by Engineer-in-Charge.\nMake :- Kirloskar / Mather & Platt / CRI / Crompton\n | | 1 | Each |
|---|
| 3 | 3 | Supply, Fixing & Testing of multistage submersible pump set of 40 HP motor capacity having water discharge 8000 GHP @ 130 Mtr head, complete all as specified and directed by Engineer-in-Charge.\nMake :- Kirloskar / Mather & Platt / CRI / Crompton\n | | 1 | Each |
|---|
| 4 | 4 | Supply, Installation and Testing of centrifugal pump set of discharge 10000 GHP @ 100 Mtr head with suitable capacity 50 HP prime mover electric motor with necessary PCC foundation in cement concrete 1:2:4 type B-1 including necessary formwork and including fully automatic Star-Delta motor starter in sheet metal enclosure type AC-3 phase, 415 Volts, 50 Hz suitable for 50 HP electric motor, complete all as specified and directed by Engineer-in-Charge.\nMake of star delta starter :- L & T model MU-G50 or technocommercially equivalent model of make ABB / Havells. \nMake of C/F Pump Set :- Kirloskar / Mather & Platt / KSB / Crompton.\n | | 1 | Each |
|---|
| 5 | 5 | M&L for XLPE insulated armoured heavy duty electric LT cable of size 120 Sqmm 3.5 core, 1.1 KV aluminium conductor, complete all as specified and directed by Engineer-in-Charge.\n | | 280 | RM |
|---|
| 6 | 6 | Excavation in trenches not exc. 1.5 mtr wide and not exc. 1.5 mtr in depth for foundation of poles, stay, laying of cable, pipe etc. and getting out in any type of soil including forming bottom surface to required slope/gradient for laying cable, complete all as specified and directed by Engineer-in-Charge.\n | | 192.97 | Cum |
|---|
| 7 | 7 | Returning, filling in including spreading, leveling, watering and well ramming in layers not exc 25cm thick after the laying of cable/pipe etc, complete all as specified and directed by Engineer-in-Charge.\n | | 97.44 | Cum |
|---|
| 8 | 8 | Removal of surplus excavated spoil to a distance not exc 50 Mtr and depositing where at a level not exceeding 1.5 mtr above the starting point, complete all as specified and directed by Engineer-in-Charge.\n | | 95.53 | Cum |
|---|
| 9 | 9 | M&L for sand cushioning to under ground cables 8cm thick before laying the cable and 15cm thick after laying, stretching and testing the cable, complete all as specified and directed by Engineer-in-Charge.\n | | 76.69 | Cum |
|---|
| 10 | 10 | M&L for Sub class ‘B’ bricks old size, laid dry flat over the cable abutting each other, complete all as specified and directed by Engineer-in-Charge.\n | | 11719 | Each |
|---|
| 11 | 11 | M&L for earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm x 6mm, burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanised strip 25×4mm as earthing by means of welding including earth work in any type of soil, charcoal dust and salt layers 15cm thick all around the earth plate as shown in electrical plate No. 5 of SSR Part I (2009) including 20mm bore GI watering pipe 'medium grade' with funnel and wire mesh, GI protection piple 'light grade' 40mm bore from earth pit to main board including PCC pit in PCC 1:3:6 type C-1 (using 20mm graded stone aggregate), angle iron frame of size 40mm x 40mm x 4mm with hold fast embeded in PCC, RCC pit cover with suitable handle, complete all as specified and directed by Engineer-in-Charge.\nNote :- If the desired resistance not found, earthing shall be done again by the contracor at no extra cost to the Govt.\n | | 8 | Each Job |
|---|
| 12 | 12 | Supply, Installation, Commissioning and Testing of PLC based 240 vac 1P2W Water level controller system for over head tank of the water supply system to send the wireless data information to the main panel from Master panel with help of sensing the water level - 6 different level through sensor in the over head tank. The controller PLC should be compliance CE, IEC 61131-2 and UL 508, CSA22.2 for Industrial Control Equipment. The main control panel shall be wall/floor mounting and shall be of suitable size made of 2mm CRCA sheet powder coated, complete all as specified and directed by Engineer-in-Charge.\nMake of Controller Panel :- TRICOLITE / DVEPL / SCHNEIDER / ADLEC. \nMake of Controller :- SCHNEIDER / ROCKWELL / PROFACE. | | 4 | Each |
|---|
| 13 | 13 | Supply, Installation, Commissioning and Testing of PLC based 240V AC, 1P2W supply system for master panel for monitoring of water level in the tank and display the visual information on panel. The system should be capable to receive the wireless data. Panel should be protected with over/under voltage (OV/UV), short circuit (SC), over load (OL), Phase indicator - 1 SET, alarm on tank empty and tank full. The panel shall be wall/floor mounting and shall be of suitable size made of 2mm CRCA sheet powder coated, complete all as specified and directed by Engineer-in-Charge.\nThe controller PLC should compliance CE, IEC 61131-2 and UL 508, CSA22.2 for Industrial Control Equipment. The programming language of controller should compliance IEC 61131-3. The program should be downable. \nMake of Controller :- SCHNEIDER / ROCKWELL /PROFACE.\nMake of Controller Panel :- TRICOLITE / DVEPL / SCHNEIDER / ADLEC.\n | | 4 | Each |
|---|
| 14 | 14 | S&F on wall / Laying in ground 1.5 Sqmm 8 Core PVC insulated & PVC Copper armoured cable with heavy duty PVC Saddles 60cm apart, complete all as specified and directed by Engineer-in-Charge.\n | | 75 | RM |
|---|
| 15 | 15 | Supply, Laying & Testing XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric cable (heavy duty) with stranded aluminium conductor, 1100 volts grade, cross sectional area 10 Sqmm 2 core, complete all as specified and directed by Engineer-in-Charge.\n | | 100 | RM |
|---|
| 16 | 16 | Supply, Laying & Testing XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 35 Sqmm 3.5 core, complete all as specified and directed by Engineer-in-Charge.\n | | 317 | RM |
|---|
| 17 | 17 | Supply, Laying & Testing XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric cable (heavy duty) with stranded aluminium conductor, 1100 volts grade, cross sectional area 35 Sqmm 4 core, complete all as specified and directed by Engineer-in-Charge.\n | | 240 | RM |
|---|
| 18 | 18 | Supply, Laying & Testing XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 70 Sqmm 3.5 core, complete all as specified and directed by Engineer-in-Charge.\n | | 230 | RM |
|---|
| 19 | 19 | S&F GI tubing light grade 40mm bore, cut to size and fixed along the pole for cable protection including clamps 02 Nos of size 25x4mm, nut bolts, washers etc, complete all as required at site and directed by Engineer-in-Charge.\n | | 22 | RM |
|---|
| 20 | 20 | S&F GI tubing light grade 50mm bore, cut to size and fixed along the pole for cable protection including clamps 02 Nos of size 25x4mm, nut bolts, washers etc, complete all as required at site and directed by Engineer-in-Charge.\n | | 27 | RM |
|---|
| 21 | 21 | S&F GI tubing light grade 80mm bore with fittings, laid for protection of cable under road crossing, culvert, fixed to walls or poles including clamps 02 Nos of size 25x4mm, nut bolts, washers etc, complete all as required at site and directed by Engineer-in-Charge.\n | | 6 | RM |
|---|
| 22 | 22 | S&F GI tubing light grade 100mm bore with fittings, laid for protection of cable under road crossing, culvert, fixed to walls or poles including clamps 02 Nos of size 25x4mm, nut bolts, washers etc, complete all as required at site and directed by Engineer-in-Charge.\n | | 10 | RM |
|---|
| 23 | 23 | Supply, Installation, Connecting electrically and Testing of feeder pillar box of size 75cm x 75cm x 30cm, outdoor type, CPRI type tested, LT 440 Volts, 50 Hz, 4 Nos aluminium bus bar, 3 Phase 4 wire supply, floor mounted, factory fabricated weather and vermin proof, made out of 3mm thick MS CRCA sheet powder coated with using 50x50x6mm size angle iron frame, powder coated having magnetic door, complete with following accessories :-\n(i) MCCB 100 Amps, 3 Pole, 415 Volts with rupturing capacity 25 KA conf to Cat Part No. HHA040U of Hager or technocommercially equivalent make as listed in Appx 'B' of the tender - 01 No.\n(ii) Contactor 32 Amp, 3 Module, conf to Cat Part No. ESC 465 of Hager or technocommercially equivalent make as listed in Appx 'B' of the tender - 01 No.\n(iii) Astronomical time switch 2 channel, conf to Cat Part No. EE181 of Hager or technocommercially equivalent make as listed in Appx 'B' of the tender - 01 No. \n(iv) MCB single pole 2 A, 1 Module, conf to Cat Part No. NCN102N of Hager or technocommercially equivalent make as listed in Appx 'B' of the tender - 02 Nos. \n(v) MCB single pole 40 Amp conf to Cat Part No. NCN140N of Hager or technocommercially equivalent make as listed in Appx 'B' of the tender - 4 Nos\n | | 1 | Each |
|---|
| 24 | 24 | Supply, Installation, Connecting electrically and Testing of LT panel board of suitable shape and size as approved by GE for B23 Phase, 4 wire, 440 Volts, AC supply, indoor cubical type, floor mounted, factory fabricated weather, dust and vermin proof, made out of 3mm thick MS CRCA sheet powder coated with using 40x40x6mm size angle iron frame and legs dully finished with using powder coated paint of approved colour all over steel surfaces complete with including PCC work for fixing panel legs, front and back door locking arrangement and aluminium busbar of suitable shape and size for 3 Phase and neutral not less than 200 Amps with and including the folloing switchgear and controls :-\nINCOMING :-\n(i) MCCB 125 Amps, 4 Pole, 415 Volts with rupturing capacity 25 KA with adjustable load setting - 01 No.\n(ii) Multifunctional meters 3 Phase, 415 Volts, accuracy class 1.0 flush mounting 96 x 96mm complete including CTs - 01 No. \n(iii) Indicating lamp (LED type) - 01 No. (Set of three)\n | | 4 | Each |
|---|
| 25 | 24.01 | OUTGOING :-\n(i) Panel mounting socket 415 Volts, 63 Amps, 5 Pin, 3P+N+E with plug top - 01 No.\n(ii) Panel mounting socket 415 Volts, 32 Amps, 5 Pin, 3P+N+E with plug top - 01 No.\n(iii) Panel mounting socket 240 Volts, 32 Amps, 2 Pin, P+N with plug top - 01 No. \n(iv) Panel mounting socket 240 Volts, 16 Amps, 2 Pin, P+N with plug top - 01 No. \n(v) MCB TPN 63 Amps, breaking capacity of Icu=10KA - 01 No.\n(vi) MCB TPN 32 Amps, breaking capacity of Icu=10KA - 01 No.\n(vii) MCB SPN 32 Amps, breaking capacity of Icu=10KA - 01 No.\n(viii) MCB SPN 16 Amps, breaking capacity of Icu=10KA - 01 No.\n | | | |
|---|
| 26 | 25 | S&F LED flood light fitting 40 Watts, IP 66, having pressure die-cast aluminium housing, heat resistant, toughened glass, individual LED lences complete making connection with street light box or OH line PVC insulated and sheathed single core multistranded aluminium conductor cable of size 1.5 sqmm, complete all as specified and directed by Engineer-in-Charge.\n | | 2 | Each |
|---|
| 27 | 26 | S&F LED street light fitting 25 Watts, IP 66, having pressure die-cast aluminium housing, heat resistant, toughened glass, individual LED lences complete making connection with street light box or OH line PVC insulated and sheathed single core multistranded aluminium conductor cable of size 1.5 sqmm, complete all as specified and directed by Engineer-in-Charge.\n | | 2 | Each |
|---|
| 28 | 27 | Supply & Installation steel tubular swaged pole 8.50 Metre long complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-22 including PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregates) as in foundation and cement concerete 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in coping, complete all as specified and directed by Engineer-in-Charge.\nNote :- Excavation and earth work shall be measured and paid saperately under respective items of BOQ.\n | | 2 | Each |
|---|
| 29 | 28 | S&F junction box made of mild steel sheet 1.6mm thick of size 250x200x150mm including 04 Nos aluminium bus bar of 2mm thick duly fitted on the suitable insulator with fixing arrangement and including MCB SP 6 Amp, clamped with pole, complete all as specified and directed by Engineer-in-Charge.\n | | 2 | Each |
|---|
| 30 | 29 | M&L for two run single core zero halogen flame retardant insulated cable of size 2.5 sqmm with unilay aluminium conductor and drawn through pole from junction box to street light connection, complete all as specified and directed by Engineer-in-Charge.\n | | 40 | RM |
|---|
| 31 | 30 | S&F street light bracket, made out of light grade 40mm bore GI tubing, 1.2 mtr long, bend to shape and size at an angle 120° by welding, fixed to pole with and including clamps 02 Nos made out of 32x6mm flat iron including nuts, bolts and washer and including two coats of aluminium paint over a coat of red oxide primer, complete all as specified and directed by Engioneer-in-Charge.\n | | 2 | Each Job |
|---|
| 32 | 31 | M&L for earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm x 6mm, burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire 4mm dia by means of welding including earth work in any type of soil, charcoal dust and salt layers 15cm thick all around the earth plate as shown in electrical plate No. 3 of SSR Part I (2009) including 20mm bore GI watering pipe 'medium grade' with funnel and wire mesh, GI protection piple 'light grade' 15mm bore upto 7.5 Mtr from earth pit to main board including PCC pit in PCC 1:3:6 type C-2 (using 20mm graded stone aggregate), angle iron frame of size 40mm x 40mm x 3mm with hold fast embeded in PCC, RCC pit cover with suitable handle, complete all as specified and directed by Engineer-in-Charge.\n | | 3 | Each |
|---|
| 33 | 32 | S&F steel sheet enclouser VTPN distribution board, double door, factory made, 3 Phase, 415 Volts, 4 way with 250 Amps MCCB 16 KA breaking capacity pre fitted at factory, IP-43 protection and 12 outgoing MCBs, complete all as specified and directed by Engineer-in-Charge.\nNote :- MCB shall be measured paid saperately under respective item of BOQ.\n | | 1 | Each |
|---|
| 34 | 33 | S&F MCB single pole 240 Volts, 63 Amps, 1 Module, C series, complete all as specified and directed by Engineer-in-Charge.\n | | 12 | Each |
|---|
| 35 | 34 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets etc. removing materials to store for keeping in safe custody or for taking credit (credit for items should be made as per conditions separately) and making good disturbed surface to match with existing surfaces, complete all as specified and directed by Engineer-in-Charge.\n | | 393 | Per Point |
|---|
| 36 | 35 | M&L for modular point wiring for one light, fan, bell, socket point controlled by one switch with 1.5 sqmm multistranded FR PVC insulated unsheathed 1100 volts grade single core copper conductor cable and 1.5 sqmm FR PVC insulated unsheathed 1100 volts grade copper conductor single core cable (green colour) as earth lead drawn in and including non metallic rigid PVC concealed conduit (ISI Marked) inclusive of conduit fitting such as bend, Tee, reducer etc. and galvanised iron sheet steel terminal box of required size 16 gauge with plastic modular top sheet cover including cutting chases to wall, making good the disturbed surfaces to match with the existing specifications, complete all as specified and dirceted by Engineer-in-Charge.\n\n | | 245 | Per Point |
|---|
| 37 | 36 | All as per srl item No. 35.00 above but two way point wiring controlled by two switchs 5 Amps two way.\n | | 2 | Per Point |
|---|
| 38 | 37 | All as per srl item No. 35.00 above but for 5 pin 5 Amp socket outlet point controlled by one switch 5 Amp one way on independant board.\n | | 56 | Each |
|---|
| 39 | 38 | All as per srl item No. 35.00 above but for 5 pin 5 Amp socket outlet point controlled by one switch 5 Amp one way on same board.\n | | 50 | Per Point |
|---|
| 40 | 39 | All as per srl item No. 35.00 above but for one 15 Amps socket outlet point concealed using 2.5 Sqmm FR PVC insulated multistrand copper conductor wire including 2.5 Sqmm FR PVC insulated unsheathed copper conductor earth wire.\n | | 40 | Point |
|---|
| 41 | 40 | S&F in replacement of modular socket outlet 6 Amps 2/3 pin, multipurpose, 2 module, complete all as specified.\n | | 106 | Each |
|---|
| 42 | 41 | S&F in replacement of modular socket outlet 5/15 Amps, 2/3 pin, multipurpose, 2 module, complete all as specified.\n | | 40 | Each |
|---|
| 43 | 42 | S&F in replacement of modular switch, one way, 6 Amps, 1 module, complete all as specified.\n | | 451 | Each |
|---|
| 44 | 43 | S&F in replacement of modular switch, two way, 6 Amps, 1 module, complete all as specified.\n | | 4 | Each |
|---|
| 45 | 44 | S&F in replacement of modular switch, one way, 16 Amps, 1 module, complete all as specified.\n | | 40 | Each |
|---|
| 46 | 45 | S&F in replacement of lamp holder insulated body with back plate for batten fittings with polycarbonate body, complete all as specified.\n | | 56 | Each |
|---|
| 47 | 46 | S&F in replacement of ceiling rose surface bakelite, 2 to 3 terminals with polycarbonate body.\n | | 141 | Each |
|---|
| 48 | 47 | S&F in replacement of fan regulator, modular step type, suitable for 1200/1400mm sweep ceiling fan, hum free, 120 W, 2 module, control speed of fan 0 to 100% and connecting electrically, complete all as specified and directed.\n | | 40 | Each |
|---|
| 49 | 48 | M&L for submain wiring with two single core FRLS PVC insulated cable 2x6 sqmm (nominal dia) copper conductor (multistrand) and drawing in and including PVC concealed conduit pipe, ISI marked including 1x6 sqmm multistranded copper conductor FRLS PVC green insulated unsheathed cable for earth continuity including taking down old unsv cable, complete all as specified and directed by Engineer-in-Charge.\n | | 90 | RM |
|---|
| 50 | 49 | S&F in replacement of surface mounted 1x20 Watt LED tube light fittings (4 feet long), prewired, decorative luminaire with inbuilt LED tube rod and acrylic cover with all accessories and making connection using 3 core, 1.50 sqmm PVC insulated and overall sheathed flexible copper conductor cable from ceiling rose/PVC connector to light fitting and testing etc, complete all as specified and directed.\nNote :- CA number shall be written on each fitting before installation.\n | | 125 | Each |
|---|
| 51 | 50 | S&F in replacement of surface mounted 1x10 Watt LED tube light fittings (2 feet long), prewired, decorative luminaire with inbuilt LED tube rod and acrylic cover with all accessories and making connection using 3 core, 1.50 sqmm PVC insulated and overall sheathed flexible copper conductor cable from ceiling rose/PVC connector to light fitting and testing etc, complete all as specified and directed. \nNote :- CA number shall be written on each fitting before installation.\n | | 12 | Each |
|---|
| 52 | 51 | S&F in replacement distribution board iron clad, double door with IP-43 protection, suitable for MCCB as incommer and MCB as outgoing 415 volts, 3 phase 50 C/S, 4 way, complete with appropriate size copper bus bar and neutral link with and including one MCCB 3 Pole, 415 Volts, 100 Amps rating with rapturing capacity 16 KA including cutting chases to wall for fixing DB and making good distributed wall surfaces to match with existing specification, complete all as specified and directed by Engineer-in-Charge.\nNote :- Outgoing MCB shall be measured and paid saperately under respective item of BOQ.\n | | 2 | Each |
|---|
| 53 | 52 | S&F in replacement of sheet metal enclosure MCB distribution board, single pole & neutral 240 volts 12 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification, complete all as specified and directed by Engineer-in-Charge.\n | | 8 | Each |
|---|
| 54 | 53 | S&F in replacement of building security light luminaire 25 Watt LED 5000 K AC 230 volts, new generation saving & enviromental friendly, long life versatile pressure die-cast, aluminium luminaries with high power LED as light source complete making connection with street light / building securty light box or OH line using PVC insulted and sheathed single core multi stranded copper conductor cable of size 1.5 Sqmm including 40mm bore medium grade GI pipe, 1.2 Mtr length of bracket including two coats of aluminium painting for muntaining of fitting, complete all as specified and directed by Engineer-in-Charge. \n | | 4 | Each |
|---|
| 55 | 54 | S&F in replacement of MCB SP 6-32 Amps 240 volts.\n\n | | 90 | Each |
|---|
| 56 | 55 | S&F in replacement of MCB SPN 6-32 Amps, breaking capacity 10 KA, 'B' series, 240 volts, 50 Hz, complete all as specified and directed.\n | | 8 | Each |
|---|
| 57 | 56 | S&F in replacement of sheet metal enclosure, SPN, 240 Volts with a two pin and earth plug and socket complete with one double pole MCB of 20 Amps rating 240 volts, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification, complete all as specified and directed by Engineer-in-Charge.\n | | 2 | Each |
|---|
| 58 | 57 | Taking down fan, sealing cable end, dismantling blades and removing fan and blades and refix the same, complete all as specified and directed by Engineer-in-Charge.\n | | 40 | Each |
|---|
| 59 | 58 | S&F LED lamp 12 Watt.\n\n | | 56 | Each |
|---|