| 1 | 1 | (1.10) Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed heavy grade PVC conduit (approx. 1.93 mm wall thickness), with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.\n(1.10.3 ) Group C | | 16 | Point |
|---|
| 2 | 2 | (1.14) Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy grade PVC conduit (approx. 1.93 mm wall thickness) as required\n(1.14.1) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire | | 10 | Metre |
|---|
| 3 | 3 | …do….(1.14.2) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | | 50 | Metre |
|---|
| 4 | 4 | …do….(1.14.3) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire | | 50 | Metre |
|---|
| 5 | 5 | …do….(1.14.4) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire | | 1 | Metre |
|---|
| 6 | 6 | …do….(1.14.5) 2 X 10 sq. mm + 1 X 6 sq. mm earth wire | | 1 | Metre |
|---|
| 7 | 7 | …do….(1.14.6) 2 X 16 sq. mm + 1 X 6 sq. mm earth wire | | 1 | Metre |
|---|
| 8 | 8 | …do….(1.14.9) 4 X 6 sq. mm + 2 X 6 sq. mm earth wire | | 1 | Metre |
|---|
| 9 | 9 | …do….(1.14.10) 4 X 10 sq. mm + 2 X 6 sq. mm earth wire | | 1 | Metre |
|---|
| 10 | 10 | …do….(1.14.11) 4 X 16 sq. mm + 2 X 6 sq. mm earth wire | | 1 | Metre |
|---|
| 11 | 11 | (1.20) Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.\n\n(1.20.1) 20 mm | | 10 | Mtr |
|---|
| 12 | 12 | (1.23) Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. \n(1.23.1) 5/6 amps switch | | 1 | Each |
|---|
| 13 | 13 | ….do… (1.23.2) 2 way 5/6 amps switch | | 1 | Each |
|---|
| 14 | 14 | ….do…(1.23.3) 15/16 amp switch | | 1 | Each |
|---|
| 15 | 15 | ….do…(1.23.4) 3 pin 5/6 amp socket outlet | | 1 | Each |
|---|
| 16 | 16 | ….do…(1.23.5) 6 pin 15/16 amp socket outlet | | 1 | Each |
|---|
| 17 | 17 | (1.24 ) Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. \n(1.24.1) 5/6 amps switch | | 2 | Each |
|---|
| 18 | 18 | ….do…(1.24.2) 2 way 5/6 amps switch | | 1 | Each |
|---|
| 19 | 19 | ….do…(1.24.3) 15/16 amp switch | | 1 | Each |
|---|
| 20 | 20 | ….do…(1.24.4) 3 pin 5/6 amp socket outlet | | 2 | Each |
|---|
| 21 | 21 | ….do…(1.24.5) 6 pin 15/16 amp socket outlet | | 1 | Each |
|---|
| 22 | 22 | (1.25) Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. | | 4 | Each |
|---|
| 23 | 23 | (1.26) Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. | | 5 | Each |
|---|
| 24 | 24 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.\n(1.27.1) 1 or 2 Module (75mmX75mm) | | 1 | Each |
|---|
| 25 | 25 | \n…do….(1.27.3) 4 Module (125mmX75mm) | | 1 | Each |
|---|
| 26 | 26 | \n…do….(1.27.4) 6 Module (200mmX75mm) | | 1 | Each |
|---|
| 27 | 27 | \n…do….(1.27.5) 8 Module (125mmX125mm) | | 1 | Each |
|---|
| 28 | 28 | \n…do….(1.27.6) 12 Module (200mmX150mm) | | 1 | Each |
|---|
| 29 | 29 | (1.41) Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. | | 1 | Each |
|---|
| 30 | 30 | (1.44) Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. | | 1 | Each |
|---|
| 31 | 31 | (2.10) Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. \n(2.10.1) Single pole | | 2 | Each |
|---|
| 32 | 32 | (2.10.3)…do…. Double pole | | 1 | Each |
|---|
| 33 | 33 | (2.16) \nSupplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts “C” curve DP MCB complete with connections, testing and commissioning etc. as required.\n | | 1 | Each |
|---|
| 34 | 34 | (2.18) Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. \n | | 1 | Each |
|---|
| 35 | 35 | (2.23)\nSupplying and fixing Cable End Box (Loose wire box)(IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required\n\n(2.23.3) For 10 way, Double door SPN MCBDB | | 1 | Each |
|---|
| 36 | 36 | (2.23.4) ….do…. For 14 way, Double door SPN MCBDB | | 1 | Each |
|---|
| 37 | 37 | (2.24) \nSupplying and fixing Cable End Box (Loose wire box)(IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.\n\n(2.24.3) For 8 way, Double door TPN MCBDB | | 1 | Each |
|---|
| 38 | 38 | (2.25)\nSupplying and fixing Cable End Box (Loose wire box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. | | 1 | Each |
|---|
| 39 | 39 | (17) Providing & installation of Wipro/Crompton/Philips make LED luminaries as follows:- \n[Note:- The job includes providing & fixing of fixing accessories as required but excluding the GI/MS conduit pipes]\n\n(17.1.1) Wipro make- CRCO10R038HP57G1/ Crompton make LCPL-36-CDL/TL (2x2)/ Philips make RC370B\n | | 12 | Each |
|---|
| 40 | 40 | (17.1.6(c)) Wipro Garnet/Philips/Crompton make 18W LED round/square light, surface/recess mounted type | | 1 | Each |
|---|
| 41 | 41 | …do...(17.1.7) Wipro make Garnet 20W LED Batten / Philips make Astra line 20W LED Batten\n | | 1 | Each |
|---|
| 42 | 42 | Providing, commissioning & testing of Usha/Crompton make following items:-\nUsha/Crompton make 240V AC, Crisp/Brisk air fan complete with bracket louvers & shutter as follows:-\n(21.3) 56” sweep size with down rod up to 2 feet long. | | 1 | Each |
|---|
| 43 | 43 | \nP/F of Usha/Crompton make 240V AC, Heavy duty industrial exhaust fan complete with bracket louvers & shutter with following:-\n…do...(21.7) 12” impeller dia, 1400 rpm | | 1 | Each |
|---|
| 44 | 44 | \nP/F of Usha/Crompton make 240V AC, Crisp/Brisk air fan complete with bracket louvers & shutter as follows:-\n…do...(21.15) 250mm size, 900 rpm | | 1 | Each |
|---|
| 45 | 45 | Providing, commissioning & testing of Usha/Crompton make following items:-\n(21.18) Wall fan, 400 mm sweep size | | 1 | Each |
|---|
| 46 | 46 | End termination of 1.1KV grade SWA PVC sheathed stranded Al. /cu conductor cable of the following sizes including supply of compression type cable glands & crimping type cu/ Al. sockets/lugs & all other consumables & accessories required for the termination.\n\n(52.2) 3 1/2 C x 185/150 sqmm. AYFY.\n | | 1 | Each |
|---|
| 47 | 47 | …do…...(52.3) 3 1/2 C x 120/95 sqmm. AYFY. | | 1 | Each |
|---|
| 48 | 48 | …do…...(52.4) 3 1/2 C x 70/50 sqmm. AYFY. | | 1 | Each |
|---|
| 49 | 49 | ….do…..(52.5) 3 1/2 C x 35/25 sqmm. AYFY. | | 1 | Each |
|---|
| 50 | 50 | ….do…..(52.6) 4 C x 16/10 sqmm. AYFY. | | 1 | Each |
|---|
| 51 | 51 | ….do…..(52.7) 4 C x 6/4 sqmm. AYFY. | | 1 | Each |
|---|
| 52 | 52 | Supply & laying/fixing/grouting/hanging of GI pipe of following sizes:-\n[Note :- The GI pipe shall be of Tata/QST/ Jindal make, medium class & all fixing accessories like socket, union, reducer etc. are to be provided by the contractor at no extra cost]\n((52(A).6)) 50 mm | | 1 | Mtr |
|---|