| NAME OF WORK: SPECIAL REPAIR TO B&R SERVICES, TOILETS, DAMAGED BIRD PROOFING AT TECH FLT AND HYDRAULIC LAB, SPECIAL REPAIR TO ROOF AND CERTAIN PORTION OF ARMOURY BUILDING, ADDN / ALTN TO GROUND CREW REST ROOM AT ORP 29 AND PROVISION OF CERTAIN WORK SERVICES IN SSC BUILDING FOR SHIFTING OF ROLE EQUIPMENT BAY AT AF STATION IZATNAGAR, BAREILLY. | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed. | 566 | Sqm | |
| 2 | 2 | M & L for vitrified ceramic nano polished, double charged, coloured tiles 10 mm thick (Square or Rectangular), area of each tile not exc. 0.36 Sqm, as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including 15 mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes finished even and rough complete all as specified and directed. | 210 | Sqm | |
| 3 | 3 | Taking down cement or cement lime plaster from brick or stone walls etc. including raking out joints, hacking for keys, scrubbing down with water etc. complete all as specified and directed. | 680 | Sqm | |
| 4 | 4 | M & L for glazed ceramic coloured tiles 600 mm X 300 mm X 7 mm thick as on vertical surface of wall such as skirting, dado, riser etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including 10 mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar 1:4 on vertical surfaces of wall finished even and rough suitable for laying wall tiles complete all as specified and directed. | 655 | Sqm | |
| 5 | 5 | M & L for preparation of old camouflage pattern painted wall or ceiling surfaces of any description over 10 cm width or girth and applying one coat of exterior grade acrylic emulsion paint as throughout base coat of olive green colour and two coats of additional exterior grade acrylic emulsion paint as in patches of different colours for making camouflage pattern as directed at site as per existing pattern complete all as specified and directed. | 200 | Sqm | |
| 6 | 6 | Supply and fixing of vertical type venetion blind of approved colour using 100 mm wide fabric blinds with and including operation cords, threads, counter nuts, connection chains and all necessary accessories and fittings as required for functioning complete all as specified and directed. MAKE- Amar or MAC. | 22 | Sqm | |
| 7 | 7 | M & L for Non skid ceramic coloured tiles 7 to 8 mm thick (Square or Rectangular) area of each tile exc. 0.11 Sqm but not exc. 0.18 sqm, as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including 15 mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes finished even and rough complete all as specified and directed. | 175 | Sqm | |
| 8 | 8 | M & L for 20 mm thick machine cut black granite stone slab as in floor, bedded and jointed with grey cement slurry, set in over and including 15 mm thick cement screed in cement mortar 1:6 and pointed with white cement with admixture of pigment to match the shade of the slab including necessary cutting, grinding, rubbing, polishing rounding to exposed edges complete all as specified and directed. | 7 | Sqm | |
| 9 | 9 | S & F in repairs vitreous china wash basin white, flat back or angle back type, size 550 X 400 mm excluding taps, waste, chain and plug but including brackets, cutting for and pinning in as required complete all as specified and directed. | 5 | Each | |
| 10 | 10 | S & F in repairs vitreous china white wash basin, oval shaped, nearest size 550 X 400 mm, fixed over counter, excluding taps, waste, chain and plug but including brackets, waste pipe, waste coupling, cutting for and pinning in as required complete all as specified and directed. | 3 | Each | |
| 11 | 11 | S & F in repairs polymer white (polypropylene Delrin and ABS) low level flushing cistern 10 litre capacity valve less, syphonic action type, complete with inlet, ball valve, float valve, bends, brackets, flush pipe, brass screws, handle etc complete having BIS description mark with IS: 7231 with and including 32 mm bore PVC flush pipe of suitable length complete all as specified and directed. | 8 | Each | |
| 12 | 12 | S & F in repairs vitreous china full stall type white urinal (Flat back or corner back type), providing and fixing plugs, bedding urinals against wall in cement mortar 1:2, securing urinal to plug and 60 cm long brass screws, pointing around urinals back in cement morter, including making connections to flushing pipe and out going pipes etc. complete all as specified and directed. | 8 | Each | |
| 13 | 13 | S & F in repairs vitreous china wash down water closet pan (Pedestal pattern) white including fixing bolts and making connection to flushing cistern, flush pipe etc. with and including plastic seat cover suitable for water closet pedestal pan, coloured closed pattern with flat bottom and cover and mid steel chromium plated or aluminium hinges devices complete all as specified and directed. | 8 | Each | |
| 14 | 14 | S & F in repairs 15 mm bore fancy type bib tap, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. | 8 | Each | |
| 15 | 15 | S & F in repairs 15 mm bore fancy type pillar tap, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘HOT’ or ‘COLD’ with long screwed shank and fly nuts, screwed for iron pipe complete all as specified and directed. | 10 | Each | |
| 16 | 16 | S & F of 32 mm size waste fitting, brass, chromium plated for glazed ware sink, basin etc. with long screwed shanks and fly-nuts, flange end, bedded in red lead cement and other end fixed complete all as specified and directed. | 16 | Each | |
| 17 | 17 | S & F of 450 mm long PVC connection with two Nos. PTMT nuts internally threaded and PVC washer suitable for 15 mm bore pipe line complete all as specified and directed. | 24 | Each | |
| 18 | 18 | S & F in repairs 15 mm bore fancy type, chromium plated stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed. | 24 | Each | |
| 19 | 19 | Demolition and breaking up drain pipes of 100 mm bore (salt glazed stoneware, AC or reinforced concrete) set in cement mortar complete all as specified and directed. | 80 | RM | |
| 20 | 20 | S & F of 100 mm bore reinforced concrete pipe class NP-2 laid, jointed with collar in neat cement slurry complete all as specified and directed. | 80 | RM | |
| 21 | 21 | M & L for cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in bed to drain pipes of 100 mm bore including packing under and haunching against the sides of pipe after they are laid and tested complete all as specified and directed. | 80 | RM | |
| 22 | 22 | Taking up or down 15 mm bore steel water tubing and connection complete all as specified and directed. | 68 | RM | |
| 23 | 23 | Re-fixing of 15 mm bore old steel water tubing and connection in new or old position (wall, ceiling, floors etc) including cleaning of old pipes and provision of new GI fittings as required complete all as specified and directed. NOTE: - OLD STEEL WATER TUBING OBTAINED FROM DISMANTLING SHALL BE USED UNDER THIS ITEM. | 20 | RM | |
| 24 | 24 | S & F of 15 mm bore steel water tubing medium grade galvanized with and including all fittings and fixed to walls and ceilings or laid under floors complete all as specified and directed | 48 | RM | |
| 25 | 25 | M & L for brick work with fly-ash old size bricks having designation 75 conforming to IS-12894 (2002), straight or curved on plan and any radius in half brick thick wall built in cement mortar 1:4 complete all as specified and directed. | 18 | Sqm | |
| 26 | 26 | M & L for rendering 15 mm thick cement plaster on fair faces of brick work or concrete surfaces with cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed. | 160 | Sqm | |
| 27 | 27 | M & L for preparation of new plastered or previously untreated surfaces of walls and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and directed. | 160 | Sqm | |
| 28 | 28 | S & F in repairs galvanised mild steel wire cloth, 0.63 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed. | 15 | Sqm | |
| 29 | 29 | S & F in repairs 4 mm thick plain, ordinary quality sheet glass and glazing with oil putty in square not exc. 0.5 sqm in each pane at any height complete all as specified and directed. | 15 | Sqm | |
| 30 | 30 | M & L for preparation of steel surfaces not exc. 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. | 22 | Per 10 RM | |
| 31 | 31 | S & F of stainless steel chromium plated soap dish complete all as specified and directed. | 13 | Each | |
| 32 | 32 | M & L for preparation of old painted wooden surfaces exc. 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. | 35 | Sqm | |
| 33 | 33 | M & L for cutting of damaged wiremesh of any description and providing new galvanised mild steel wire cloth, 0.63 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples as in bird proofing of hangers above a height of 12.00 metres from FFL complete all as specified and directed. | 60 | Sqm | |
| 34 | 34 | M & L for cutting of damaged flat iron members and providing new flat iron members of existing size duly welded to existing frame of the bird proofing of hangers above a height of 12.00 metres from FFL complete all as specified and directed. | 60 | Kg | |
| 35 | 35 | M & L for preparation of new or previously untreated steel surfaces, provided as bird proofing of hangers above a height of 12.00 metres from FFL, over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. | 60 | Sqm | |
| 36 | 36 | Complete removal to existing roof treatment comprising polymeric membrane, fibre felt, tar felt including bitumenous layers by scrapping the same and removal of the debries in low laying areas complete all as specified and directed. | 1040 | Sqm | |
| 37 | 37 | M & L for providing roof treatment comprising of the following specifications complete all as specified and directed: - \n(i) Rendering 10 mm thick cement plaster in cement mortar 1:3 mixed with and including polymer based water proofing compound over existing roof surface after proper cleaning.\n(ii) Applying a coat of bituminous primer @ 0.30 Liters per Sqm over fully dried plastered surface.\n(iii) Applying a coat of hot, blown bitumen grade 85/25 confirming to IS-702 @ 1.2 Kg per Sqm to the entire roof surface over primed surface. | 1040 | Sqm | |
| 38 | 37.01 | (iv) Laying of polymeric water proofing membrane consisting of 90 to 100 micron thick central core of HMHDPE film and standard weight 3 Kg per Sqm with minimum 100 mm side and end laps as per manufacture’s instructions and strict supervision of manufacture’s technical representative.\n(v) Again applying a coat of hot, blown bitumen grade 85/25 confirming to IS-702 @ 1.2 Kg per Sqm to the entire roof surface over membrane.\n(vi) Applying two coats of aluminium paint on bitumenous surface of roof. | |||
| 39 | 38 | M & L for cutting out cracks to V-section in existing roof, chajjas, terracing or any similar position upto 40 mm deep, cleaning out the same with water jets to get rid of any loose material, wetting, grouting with cement and sand slurry 1:3 mixed with liquid water proofing compound complete all as specified and directed. | 105 | RM | |
| 40 | 39 | Taking up or down 20 mm bore steel water tubing and connection complete all as specified and directed. | 60 | RM | |
| 41 | 40 | S & F of 20 mm bore steel water tubing medium grade galvanized with and including all fittings and fixed to walls and ceilings or laid under floors complete all as specified and directed | 45 | RM | |
| 42 | 41 | Re-fixing of 20 mm bore old steel water tubing and connection in new or old position (wall, ceiling, floors etc) including cleaning of old pipes and provision of new GI fittings as required complete all as specified and directed. NOTE: - OLD STEEL WATER TUBING OBTAINED FROM DISMANTLING SHALL BE USED UNDER THIS ITEM. | 15 | RM | |
| 43 | 42 | S & F of 20 mm bore gunmetal globe or gate valve, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed. | 3 | Each | |
| 44 | 43 | Dismantling of brick tiles or terracing tiles, bedded and pointed in cement mortar, single layer on roof complete all as specified and directed. | 750 | Sqm | |
| 45 | 44 | Demolition of existing mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) complete all as specified and directed. | 56.25 | Cum | |
| 46 | 45 | M & L for providing plain cement concrete, type B-1, 1:2:4 (using 20 mm graded stone aggregate) as in levelling course over roof slab, base for PVC water tanks or antina mast and the like complete all as specified and directed. | 56.25 | Cum | |
| 47 | 46 | M & L for providing plain cement concrete type B-1, 1:2:4, (using 20 mm graded stone aggregate), as in copings, bed block for embedding hold fasts, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed. | 2 | Cum | |
| 48 | 47 | M & L for rendering 15 mm thick cement plaster in cement mortar 1:4 including mixing of water proofing compound as per manufacturer’s instructions on fair faces of brick work or concrete surfaces finished even and fair complete all as specified and directed. NOTE: - WATER PROOFING COMPOUND SHALL BE MEASURED AND PAID SEPARATELY AS SUPPLY ONLY. | 100 | Sqm | |
| 49 | 48 | Supply only liquid water proofing compound complete all as specified. | 34 | Litre | |
| 50 | 49 | Taking down eaves gutters and rain water pipes (any size or pattern) including all fittings, heads, shoes, bends, swan necks etc. complete all as specified and directed. | 77.3 | RM | |
| 51 | 50 | S & F of 110 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joint fixed to walls complete all as specified and directed. | 77.3 | RM | |
| 52 | 51 | Dismantling of water tank exc. 250 Litre but not exc. 500 Litre capacity complete all as specified and directed. | 2 | Each | |
| 53 | 52 | Dismantling of water tank exc. 500 Litre but not exc. 1000 Litre capacity complete all as specified and directed. | 2 | Each | |
| 54 | 53 | S & F of 20 mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gram) complete all as specified and directed. | 4 | Each | |
| 55 | 54 | S & F in repairs 20 mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gram) complete all as specified and directed. | 1 | Each | |
| 56 | 55 | S & F of 500 Litre capacity rotational moulded polythene water storage tanks (cylindrical vertical with closed top) of specifications as per MES Schedule 2009, Part – I and hoisted, fixed in position complete all as specified and directed. | 2 | Each | |
| 57 | 56 | S & F of 1000 Litre capacity rotational moulded polythene water storage tanks (cylindrical vertical with closed top) of specifications as per MES Schedule 2009, Part – I and hoisted, fixed in position complete all as specified and directed. | 2 | Each | |
| 58 | 57 | Demolition of brick work or stone / boulder masonry including all quoins, arches, pillars, etc. built in cement mortar or cement lime mortar complete all as specified and directed. | 3 | Cum | |
| 59 | 58 | M & L for providing reinforced cement concrete 1:2:4 (Nominal Mix) type B-1, using 20 mm graded stone aggregate, as in beams, cantilevers, bressummers, lintels over 1.50 m span and the like complete all as specified and directed. | 0.47 | Cum | |
| 60 | 59 | M & L for use & waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc. also splayes between floors and beams in rough finished surface of concrete complete all as specified and directed. | 5.3 | Sqm | |
| 61 | 60 | M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. | 55 | Kg | |
| 62 | 61 | M & L for mild steel TMT bars 5 mm dia and over up to and including 10 mm dia as in stirrups, spacer and binders, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. | 18 | Kg | |
| 63 | 62 | Taking down plastering on lathing (other than wire-netting), without removing lathing, in lime mortar (one side only measured in cases where both sides are plastered) complete all as specified and directed. | 10 | Sqm | |
| 64 | 63 | M & L for rendering 10 mm thick cement plaster on fair faces of brick work or concrete surfaces with cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed. | 13 | Sqm | |
| 65 | 64 | Taking down chowkhats or frames area not exc. 1.50 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed. | 4 | Each | |
| 66 | 65 | S & F of aluminum section powder coated of approved colour as in door frame and shutter partially glazed with 5.5 mm thick one side refelctive glass and partially panelled, panel made of 5 mm thick PVC composite board duly fixed with aluminium clips comprising of the following complete as specified and directed:-\n(i) Frame made of section size 100 x 40 x 2 mm thick. \n(ii) Styles of shutter made of section size 85 x 44.45 x 1.7 mm thick. \n(iii) Top rail made of section size 114.30 x 44.45 x 1.7 mm thick. \n(iv) Middle rail made of section size 83.50 x 44.75 x 1.7 mm thick.\n(v) Bottom rail made of section size 114.30 x 44.15 x 1.7 thick.\n(vi) Glazing aluminium clips made of 0.70 mm thick section. \n(vii) 2 Nos. stainless steel Handles 300 mm long as approved.\n(viii) Tower bolt having dia of bolt 9.90 mm dia and 200 mm long.\n(ix) Mortice lock 100 mm size, 7 Livers make Godrej.\n(x) Hold fast aluminium 100 mm long.\n(xi) Rubber gasket made of virgin white PVC and namda rope of appropriate size for proper air tightness. | 11.5 | Sqm | |
| 67 | 66 | S & F aluminium powder coated sliding windows with shutter and frame made with aluminium section 02 tracks (One shutter with stainless steel wire cloth and another one with glass) complete comprising the following: - \n(i) Frame made of section size 61.85 x 31.75 x 1.2 mm thick, suitable for 02 tracks and having weight not less than 0.659 Kg per RM. \n(ii) Shutter made of section size 40 x 18 x 1.5 mm for styles and rails. \n(iii) Aluminium powder coated grill weighing not less than 1.00 Kg per Sqm. \n(iv) Glass 4.8 mm thick tinted or reflective with rubber gasket of white colour and suitable aluminium clips.\n(v) Stainless steel wire cloth. | 8 | Sqm | |
| 68 | 67 | M & L for preparation of new plastered or previously untreated surfaces of walls and applying two coats of distemper oil emulsion over a thin layer of wall care putty wherever required complete all as specified and directed. | 113 | Sqm | |
| 69 | 68 | M & L for preparation of preparation of old decorated wall surfaces and applying one coat of distemper oil emulsion over a thin layer of wall care putty wherever required complete all as specified and directed. | 600 | Sqm | |
| 70 | 69 | S & F of solid PVC door frame of size 50 mm X 47 mm made out of 5 mm thick plain coloured PVC sheet reinforced with mild steel square tube as per specification and drawing given on MES schedule Part-II (2010) complete all as specified and directed. | 5 | RM | |
| 71 | 70 | S & F of 30 mm thick (style thickness) factory made solid panel PVC shutter consisting of frame made out of mild steel tubes for top and bottom rails, mild steel frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side & as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles and rails with suitable PVC sheets beading and joined together with solvent cement as per specification and drawing given on MES schedule Part-II (2010) complete all as specified and directed. | 2 | Sqm | |
| 72 | 71 | S & F of 75 mm long mild steel butt hinges, medium weight cold rolled complete all as specified and directed. | 3 | Each | |
| 73 | 72 | S & F of 100 mm long mild steel butt hinges, medium weight cold rolled complete all as specified and directed. | 2 | Each | |
| 74 | 73 | S & F of 250 mm long (Length of bolt) aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheets, cast or extruded sections and fixing bolts and sliding bolt of extruded sections or cast aluminium alloy complete all as specified and directed. | 2 | Each | |
| 75 | 74 | S & F of aluminium powder coated grill of weight not less than 1.50 Kg / Sqm fixed to aluminium frame with Aluminium powder coated beading complete all as specified and directed. | 12 | Sqm | |
| 76 | 75 | S & F of stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed. | 12 | Sqm | |
| 77 | 76 | Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation etc. or for manholes, cesspits, shafts etc. not exc. 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed. | 1.5 | Cum | |
| 78 | 77 | Removing surplus excavated material (SOIL) to distance not exc. 50 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed. | 1.1 | Cum | |
| 79 | 78 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soil complete all as specified and directed. | 0.4 | Cum | |
| 80 | 79 | M & L for providing plain cement concrete, type D-2, 1:4:8 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed. | 0.7 | Cum | |
| 81 | 80 | M & L for brick work with fly-ash old size bricks having designation 75 conforming to IS-12894 (2002), straight or curved on plan exc. 6.00 m mean radius built in cement mortar 1:6 complete all as specified and directed. | 2 | Cum | |
| 82 | 81 | M & L for rendering 15 mm thick cement plaster on fair faces of brick work or concrete surfaces with cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed. | 105 | Sqm | |
| 83 | 82 | M & L for sand filling under floors or in foundations including watering and consolidation as required complete all as specified and directed. | 2.5 | Cum | |
| 84 | 83 | M & L for providing 100 mm thick cement concrete 1:4:8 type D-2 (using 40 mm grade stone aggregate) as in sub floor, sub base of floor finished even and rough complete all as specified and directed. | 1.5 | Sqm | |
| 85 | 84 | M & L for providing 100 mm thick cement concrete 1:2:4 type B-1 (using 20 mm thick graded stone aggregate) as in floor, finishing top surface even and smooth without using extra cement complete all as specified and directed. | 1.5 | Sqm | |
| 86 | 85 | S & F of double action heavy duty floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass and other parts made of mild steel complete all as specified and directed. | 2 | Each | |
| 87 | 86 | S & F of fine fissured board of size 595 X 595 X 15 mm thick mineral fibre accoustic false ceiling tiles with and including false ceiling grid system at any height with back of the ceiling duly sanded and finished with a coat of protective paint and front duly finished and fixed to true lock PVC DLE KL-24 suspension system (hot dipped galvanised steel section) of exposed T-section grid with exposed face powder coated white colour including making good electric service such as point wiring etc. complete all as specified and directed. NOTE: - For detailed description and specificatios of ceiling grid and ceiling board refer Particular Specifications hereinafter. (CAT Part No. 1833 M of ARMSTRONG or as approved by GE in writing.) | 11.6 | Sqm | |
| 88 | 87 | S & F of collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and directed. | 35 | Sqm | |
| 89 | 88 | M & L for preparation of new or previously untreated steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. | 105 | Sqm | |
| 90 | 89 | S & F of 2 mm thick linoleum, plain coloured, laid dry in floors including stretching, cutting, fitting and sealed down with an approved adhesive complete all as specified and directed. | 250 | Sqm | |
| 91 | 90 | Taking down carefully aluminium / copper point wiring (light point, fan point, socket outlet point or power point) any type (batten, surface conduit or concealed conduit) complete with and including fittings and fixtures such as switches, ceiling rose, pendent, lamp holder, regulator, switch, socket outlet, light fittings, shade conical etc. and separating serviceable fittings for reuse in the work as directed including removing of unserviceable fittings & fixtures with wiring cable, battens, wooden boards etc. from site and making good disturbed surfaces of walls, floors ceiling etc. complete all as specified and directed. | 23 | Per Point | |
| 92 | 91 | Taking down carefully old unserviceable sub main wiring of any description including batten or conduit complete all as specified and directed. | 50 | RM | |
| 93 | 92 | Taking down carefully old unserviceable MCB DB main switch alongwith MCBs / Isolators of any description complete all as specified and directed. | 1 | Each | |
| 94 | 93 | M & L for point wiring for one light point / fan point / bell point / 5 Ampere socket outlet point (independent point), controlled by one, one way switch with 1.50 sqmm size, PVC insulated, unsheathed 1100 volts grade single core multi-stranded copper conductor cable (FRLS) drawn into and including PVC conduit medium grade (not less than 20 mm dia) with and including its all necessary fittings and accessories fixed concealed with and including necessary chase cutting on brick / stone masonry walls and making good as per existing and sunk cast iron or 1.2 mm thick pressed steel terminal boxes for mounting fittings like switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated sheet cover fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.50 sqmm size stranded copper conductor cable (FRLS) as in earth wire and connecting all metal parts to common earth dolly complete all as specified and directed. | 14 | Per Point | |
| 95 | 94 | All as per item No. 93.00 hereinbefore but wiring for one 3 / 5 pin 5 Ampere socket outlet point on independent board, controlled with other switches complete all as specified and directed. | 3 | Per Point | |
| 96 | 95 | All as per item No. 93.00 hereinbefore but wiring for one 3 / 5 pin 5 Ampere socket outlet point on the same board, controlled with other switches complete all as specified and directed. | 2 | Per Point | |
| 97 | 96 | All as per item No. 93.00 hereinbefore but wiring for one 3 / 6 pin 15 Ampere socket outlet point on independent board and wiring using with 2.50 sqmm size cables complete all as specified and directed. | 4 | Per Point | |
| 98 | 97 | S & F of switch piano flush button single pole 230 volts, one-way 5 Ampere complete all as specified and directed. | 31 | Each | |
| 99 | 98 | S & F of socket outlet 5 Ampere, 2 and 3 pins (TOTAL 05 PINS), flush type 250 volts AC complete all as specified and directed. | 5 | Each | |
| 100 | 99 | S & F of lamp holder, PVC / polycarbonate type insulated body with back plate suitable for batten / angle fittings complete all as specified and directed. | 2 | Each | |
| 101 | 100 | S & F of ceiling rose surface bakelite, 65 X 50 mm, three terminals, PVC / polycarbonate insulated body complete all as specified and directed. | 26 | Each | |
| 102 | 101 | S & F of socket outlet two-in-one, 3 pin each suitable for 5 and 15 Amperes flush type, 250 volts AC complete all as specified and directed. | 12 | Each | |
| 103 | 102 | S & F of switch piano flush button single pole 230 volts, one-way 15 Ampere complete all as specified and directed. | 12 | Each | |
| 104 | 103 | S & F of wall / surface mounted type LED light fitting 1 X 20 watt (4 feet long), extruded aluminium batten with multiple lumen packages complete with all accessories internally pre-wired and including making electric connection with flexible twin core 1.00 sqmm size stranded copper conductor cable from light fitting to ceiling rose complete all as specified and directed. Make- Philips Cat. Part No. BN021C LED20S PSU CW GR S2 (SmartBright) of Philips or SLE BTN T8 20W (LED T8 AL Batten) of Surya. | 6 | Each | |
| 105 | 104 | S & F of retrofit type LED lamp 12 watt capacity complete all as specified and directed. | 2 | Each | |
| 106 | 105 | Supply and fixing of 1200 mm sweep 240 volts, AC having BEE 5 star rating ISI marked, off white coloured ceiling fan complete with fan blade, capacitor, canopy, down rod etc. with and including making electric connection with three single core flexible copper conductor cable of size 1.50 Sqmm from ceiling rose to connector of ceiling fan and writing MES No. with black synthetic enamel paint minimum font size 2.00 cm high complete all as specified and directed. | 2 | Each | |
| 107 | 106 | Supply and fixing of wall mounted fan 300 mm sweep, 1350 RPM, single phase, 230 volts AC, 50 Hz, single phase metalic body (Heavy Duty) complete with pull cord control for speed and oscilleting mechanism, necessary mounting arrangement and making electric connection using three core flexible twisted copper conductor of size 23/0.0076 complete all as specified and directed. | 2 | Each | |
| 108 | 107 | Supply and fixing of 450 mm sweep heavy duty metal body exhaust fan, single phase 230 volts AC, 900 RPM complete with and including all accessories, louver shutter and making suitable size hole for fixing of exhaust fan including making good the disturbed surface as per existing specifications, grouting of ragged bolts in wall for fixing of exhaust fan, frame, louvers and making electric connection with three single core flexible copper conductor cable of size 2.50 Sqmm from ceiling rose to connector of exhaust fan and writing MES No. with black synthetic enamel paint minimum font size 2.00 cm high complete all as specified and directed. | 2 | Each | |
| 109 | 108 | S & F of electronic type fan regulator 230 volts, step type having five steps, switch type, hum free complete all as specified and directed. | 2 | Each | |
| 110 | 109 | S & F of 1100 volts grade heavy duty PVC insulated (FRLS) copper multi-stranded conductor cable as in sub main wiring, drawn into & including PVC conduit medium grade not less than 25 mm dia including its all accessories & fittings, fixed concealed with and including chase cutting and making good the same as per existing specifications along with continuous run of multi-stranded copper conductor PVC insulated (FRLS) (green colour) cable as earth wire drawn in same conduit complete all as specified and directed comprising of the following: - | |||
| 111 | 109.01 | (a) 2 X 2.50 sqmm as main wires + 1 X 1.50 sqmm as earth wire. | 25 | RM | |
| 112 | 109.02 | (b) 2 X 4.00 sqmm as main wires + 1 X 2.50 sqmm as earth wire. | 25 | RM | |
| 113 | 110 | S & F of flush mounting factory made Ekinoxe SPN DB's Double door, 8 way (Cat. Part No. 607711 of Legrand or Cat. Part No. A9HSND08 of SCHNEIDER or Cat. Part No. CSDBSPNDD08 of C&S), IP-43 Protection, IK-09 with metal door, with neutral bar, Earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed. | 3 | Each | |
| 114 | 111 | S & F of MCB single pole and neutral, 240 volts, 32 to 40 Ampere breaking capacity 10 KA, ‘C’ Series complete all as specified and directed. | 2 | Each | |
| 115 | 112 | S & F of MCB single pole 240 volts, 6 to 32 Ampere 50 Hz, 10 KA, ‘C’ series complete all as specified and directed. | 24 | Each | |
| 116 | 113 | M & L for earthing complete with galvanised steel earth plate electrode 600 mm X 600 mm X 6 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.50 m below normal ground level, connected to galvanised earth lead 4 mm dia all as shown on electrical plate No. 3 of MES schedule 2009, Part–I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover in PCC 1:2:4, type B-1, duly reinforced with 6 mm dia mild steel TMT bars @ 150 mm both ways center to center with suitable lifting handle to cover, earth pit of PCC 1:2:4 type B-1, GI protection pipe light grade 15 mm bore including testing on completion of job complete all as specified and directed. NOTE: - ON TESTING AFTER COMPLETION OF JOB, IF DESIRED EARTH RESISTANCE (i.e. LESS THAN ONE OHM) IS NOT OBTAINED, THE EARTHING SHALL BE REDONE BY THE CONTRACTOR WITHOUT ANY EXTRA COST TO GOVT. | 2 | Each | |
| 117 | 114 | Supply and fixing of test point terminal block made of gun metal or phasphorous bronze size 75 X 75 X 25 mm drilled and screwed including 3 Nos. 8 mm dia 25 mm long hexagonal head screw fixed to wall and connected with earth strip complete all as specified and directed. | 2 | Each | |
| 118 | 115 | S & F of 40 mm bore light grade galvanised iron tubing with all necessary GI fittings as in protection pipe of cable laid in trenches or fixed to pole or other vertical surface or for insertion in horizontal boring complete all as specified and directed. | 10 | RM | |
| 119 | 116 | M & L for making horizontal hole by mechanical Boring under hard standing, pavements or roads for insertion of GI pipes 40 to 80 mm bore and making good the disturbed surface complete all as specified and as directed. | 10 | RM | |
| 120 | 117 | M & L for point wiring for one light point / fan point / bell point / 5 Ampere socket outlet point (independent point), controlled by one, one way switch with 1.50 sqmm size, PVC insulated, unsheathed 1100 volts grade single core multi-stranded copper conductor cable (FRLS) drawn into and including PVC casing-N-capping medium grade of suitable size fixed on surface and sunk cast iron or 1.2 mm thick pressed steel terminal boxes for mounting fittings like switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated sheet cover fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.50 sqmm size stranded copper conductor cable (FRLS) as in earth wire and connecting all metal parts to common earth dolly complete all as specified and directed. | 12 | Per Point | |
| 121 | 118 | All as per item No. 117.00 hereinbefore but wiring for one 3 / 6 pin 15 Ampere socket outlet point on independent board and wiring using with 2.50 sqmm size cables complete all as specified and directed. | 8 | Per Point | |
| 122 | 119 | Supply and fixing of wall mounted fan 450 mm sweep, 1350 RPM, single phase, 230 volts AC, 50 Hz, single phase metalic body (Heavy Duty) complete with pull cord control for speed and oscilleting mechanism, necessary mounting arrangement and making electric connection using three core flexible twisted copper conductor of size 23/0.0076 complete all as specified and directed. | 12 | Each | |
| 123 | 120 | S & F of 1100 volts grade heavy duty PVC insulated (FRLS) copper multi-stranded conductor cable as in sub main wiring, drawn into & including PVC casing-N-capping not less than 25 mm size fixed on surface along with continuous run of multi-stranded copper conductor PVC insulated (FRLS) (green colour) cable as earth wire drawn in same casing-N-capping complete all as specified and directed comprising of the following: - | |||
| 124 | 120.01 | (a) 2 X 4.00 sqmm as main wires + 1 X 2.50 sqmm as earth wire. | 60 | RM | |
| 125 | 120.02 | (b) 4 X 10.00 sqmm as main wires + 2 X 6.00 sqmm as earth wire. | 50 | RM | |
| 126 | 121 | S & F of MCB 04 pole, 415 volts, 63 Ampere breaking capacity 10 KA, ‘C’ Series complete all as specified and directed. | 1 | Each | |
| 127 | 122 | S & F of blanking plate to fill up the blank spaces of DBs after fixing of MCBs complete all as specified and directed. | 1 | Each | |
| 128 | 123 | M & L for Chemical Earthing with copper earth plate electrode 900 x 600 x 5 mm thick burried directly in ground, earth pit not less than 5.10 metres below normal ground level and complete size of pit shall be 1.60 m x 1.60 m x 5.10 metres, with top edge of the plate not less than 3.75 metres below normal ground level, earth plate surrounded from all sides by 20 cm thick salt and charcoal dust and Magnisium sulphate filling in alternate layers of 20 cm thick up to 1.8 metres height and including connected to copper strip 50 x 6 mm (upto 7.5 Metres) by means of brazing / coppers nut-bolts, earth strip protected with 65 mm bore light grade pipe from electrode and upto and including the earth test point of galvanised iron / steel of size 75 x 75 x 25 mm test point 15 mm bore watering pipe light grade GI funnel, wire mesh, earth plate surrounded from all sides by 20 cm thick salt (40 Kg), charcoal dust (40 Kg) and Magnisium sulphate (50 Kg) filling in each alternate layers upto 1.80 m height including excavation, removal surplush soil to a distance not exc. 50 m, PCC pit in PCC (1:3:6) type C-1, using 20 mm graded stone aggregate, RCC cover 40 mm thick in RCC (1:2:4) type B-1, using 20 mm graded stone aggregate reinforced with 8 mm dia mild steel deformed bars @ 75 mm centre to centre both ways complete all as specified and directed. NOTE:- Additional Chemical compound if required on account to achieve earth resistance less than 1.00 ohm shall deemed to be included in the unit rate of this item. On testing after completion of job, if desired earth resistance (i.e. less than one ohm) is not obtained, the earthing shall be redone by the contractor without any extra cost to Govt. | 2 | Each Job | |
| 129 | 124 | Supply, installation, commissioning and testing of hi wall, copper wounded, BEE 5 star rating, inverter type (DC inverter type) (hot and cool type) R-410A, CFC free split AC with indoor and outdoor units and cordless remote control unit suitable for 2.00 TR capacity complete all as specified and directed. NOTE: - Power cable between indoor and outdoor unit shall be deemed to be included in quoted rates. Copper piping and drain pipe shall be measured and paid seperately under respective items of this schedule. | 4 | Each | |
| 130 | 125 | S & F of copper tubing pair of two pipe for suction and discharge, size of suction pipe 3/4\" and discharge pipe 1/2\" diameter, 0.8 mm wall thick complete with separate nythyle vinil insulation 9 mm thick including chase cutting wall and making good of existing surface as required on site complete all as specified and directed. | 12 | RM | |
| 131 | 126 | Supply and fixing of wall / floor mounting type powder coated stand suitable for mounting of out door unit of Split AC as per manufactur's recommendations complete all as specified and directed. | 4 | Each Set | |
| 132 | 127 | S & F of 25 mm dia unplasticised PVC pipes of pressure rating 100 Kg per Sqcm fixed to walls, ceilings or laid in floors including chase cutting on wall and making good as per existing complete all as specified and directed. | 20 | RM | |
| 133 | 128 | S & F of sheet metal enclosure with socket plug top and MCB single pole and neutral enclosure with a two pin and earth plug and socket complete with one No. single pole MCB 25 Ampere capacity 240 Volts as per Cat. Part No. 607841 of Legrand or CSDBPSSPN020 of C&S complete all as specified and directed. | 4 | Each | |
| 134 | 129 | Supply and fixing of 5 KVA capacity copper wounded voltage stabilizer for automatic operation, single phase naturally air cooled, indoor type designed for input voltage of 90 to 250 Volt with stabilized output voltage at 230 Volts with accuracy of + 2.5% complete all as specified and directed. | 4 | Each |