Military Engineer Services-MES has published Provision Of Certain Sanctioned Br And Electromechanical Works At Military Station Dharamshala And Charri Camp. Submission Date for this Tender is 17-01-2020. Electromechanical Work Tenders in Dharamshala Himachal Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 13-Jan-2020 | Corrigendum02 | Date | 17-01-2020 |
Name of Work : Provn of certain sanctioned BR and EM works at military station Dharamshala and Charri camp. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Excavation over areas, not exceeding 1.5 m deep and getting out in any type of Soil, complete all as specified and directed by Engr-in-Charge. | 27.5 | Cum | |
2 | 2 | Plain cement concrete M-10, nominal mix, type C-2 ( using 40 mm graded stone arrgegates) as in foundation, filling and mass concrete complete all as specified & directed by Engr-in-Charge. | 2 | Cum | |
3 | 3 | Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking and binding spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or\nsecuring with clips complete all as specified and directed by the Engr-in-Charge. | 1100 | Kg | |
4 | 4 | Formwork to sides of concrete foundations, footings bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter complete all as specified and directed by the Engr-in-Charge. | 15 | Sqm | |
5 | 5 | RCC, M-30, (Design mix), type B-1 (using 20mm graded stone aggregate) for foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc, basement slabs, under reamed piles and mass concrete complete all as specified and directed by the Engr-in-Charge. | 6 | Cum | |
6 | 6 | Form work to faces of walls, retaining walls, abutments, parapets and staircase arailings and similar work including attached pillasters, buttresses, etc, vertical or to battle complete all as specified and directed by the Engr-in-Charge. | 60 | Sqm | |
7 | 7 | RCC, M-30, (Design mix), type B-1 (using 20mm graded stone aggregate) for walls, retaining walls, basement walls, ballest walls and the like any thickness above top of footings including attached pilasters and buttresses complete all as specified and directed by the Engr-in-Charge. | 11 | Cum | |
8 | 8 | 80mm bore GI steel water tubing, medium grade, galvanised with all fittings and fixtures fixed to walls and celling or laid in floor, complete all as specified and directed by Engr-in- Charge complete all as specified and directed by the Engr-in-Charge. | 5.5 | RM | |
9 | 9 | 12 mm wire netting to galvanised steel wire 1.40mm dia complete all as specified and directed by the Engr-in-Charge. | 6 | Sqm | |
10 | 10 | Hand packing (any thickness) at back of walls over arches etc and raising (or lowering ) to the required level complete all as specified and directed by the Engr-in-Charge. | 0.38 | Cum | |
11 | 11 | Removal of excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above starting point, complete all as specified & directed by Engr-in-Charge. | 10.85 | Cum | |
12 | 12 | Returning, filling in (soil), including spreading, levelling, watering and well ramming in layers not exc 25 cm thick in any type of soil complete all as specified and directed by Engr-in-Charge. | 16.65 | Cum | |
13 | 13 | Excavaion in post holes (or similar holes), each n exc 0.5 cum, getting out returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, in any type of soil complete all as specified and directed by the Engr-in-Charge. | 9 | Each | |
14 | 14 | Plain cement concrete, M-15, type B-1 (using 20 mm graded crushed stone aggregate) as in post holes for fixing iron pole/angles etc Complete all as specified and directed by Engr-in-Charge. | 0.3 | Cum | |
15 | 15 | Plain cement concrete, M-7.5, nominal mix, type B-2 ( using 40 mm graded stone arrgegates) in foundation, filling and mass concrete, complete all as specified & directed by Engr-in-Charge. | 8 | Cum | |
16 | 16 | Rolled MS work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. of Fe-410W (Gde E-250) quality 'B' complete all as specified and directed by Engr-in-Charge. | 550 | Kgs | |
17 | 17 | Mild steel framed work as in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes confirming to IS 1161-1979 grade St-240 complete all as specified and directed by the Engr-in-Charge. | 320 | Kg | |
18 | 18 | Two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel surfaces including prepration of surfaces area over 10cm width or girth complete all as spcified and directed by Engr-in-Charge. | 18 | Sqm | |
19 | 19 | Hard Core of gauge 63mm, deposited, spread and levelled in layers not execeeding 15cm thick, watered and rammed to a true surfaces with broken stone complete all as specified and directed by Engr-in-Charge. | 6 | Cum | |
20 | 20 | Plain cement concrete, 100 mm thick, M-15, (nominal mix), type B-2 (using 40mm graded crushed stone aggregates) as in hard standing, finished even and smooth without using extra cement complete all as specified & directed by Engr-in-Charge. | 65 | Sqm | |
21 | 21 | Pre-painted galvalume aluminium Zinc coating GI based corrugated steel sheeting 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws complete all as specified and directed by Engr-in-Charge. | 68 | Sqm | |
22 | 22 | Cutting holes into or thorugh brick walls built in cement mortar and stone walls built in lime mortar or walls of lime concrete exceeding 150 sqcm all as specified and directed by Engr-in-Charge. | 500 | Per CM | |
23 | 23 | Galvanised iron steel water tubing, medium grade, 15mm bore, ISI marked with screwed socket joints together with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, lugs and union etc., fixed to wall/roofs/under floors/trenches etc. complete all as specified and directed by Engr-in-charge. | 116 | RM | |
24 | 24 | Bib taps, 15mm bore chromium plated(lang bend), cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engr-in- Charge. | 12 | Each | |
25 | 25 | Sink made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes,including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe,overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm including 40mm size CP waste coupling & PVC waste pipe complete all as specified and directed by Engr-in-Charge. | 12 | Each | |
26 | 26 | 32 mm dia waste fittings, brass chromium plated for glazed ware sinks, basins etc with long crewed shanks and fly-nuts, flange and end bedded in red lead cement and other end fixed all as specified and directed by Engr-in-Charge. | 12 | Each | |
27 | 27 | 32 bore Poleyethylene pipe, low density polyethylene (LDPE) pipes of pressure rating 6 Kgs/sq cm complete all as specified and directed by Engr-in-Charge. | 18 | RM | |
28 | 28 | Walling of random rubble stone masonry, uncoursed, well bonded, bedded and solidly hearted built in CM 1:6 complete all as specified and directed by Engr-in-Charge. | 12 | Cum | |
29 | 29 | Plain cement concrete, M-5, nominal mix, type C-2 ( using 40 mm graded stone arrgegates) in foundation, filling and mass concrete, complete all as specified & directed by Engr-in-Charge. | 1.32 | Cum | |
30 | 30 | Extra over stone walling for hammer dressing to face stone and dressing of face beds and joints as specified of random rubble walling uncoursed or brought up to courses with maximum depression on face from straight edge held against the dressed surface not exceeding 40mm for granite or trap stone,complete all as specified and directed by Engr-in-Charge. | 20 | Sqm | |
31 | 31 | Rendering 20mm thick in cm 1:4 in two layers on stone masonry surface or other than fair faces of brick finished even and smooth without using extra cement complete, all as specified and directed by Engr-in-Charge. | 20 | Sqm | |
32 | 32 | Plain Cement concrete, M-15, type B-1 (using 20 mm graded crushed stone aggregate) as in coping and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed by Engr-in-Charge. | 0.35 | Cum | |
33 | 33 | Electric water heater, storage type, capacity 25 ltr, BEE 5 star rated inclduing inlet & outlet connections, testing & commissioning complete all as specified and directed by Engr-in-Charge. \nMake: Jaquar Model Elena/Racold Model ALTRO 2/Venus Model: WAVE \nNote : Fixing of geyser on wall with suitable size anchore bolt with hammer drill and making good the disturbed surface including plaster work shall be part of job at no extra cost. | 16 | Each | |
34 | 34 | Point wiring with 2.5 Sqmm copper conductor (Multi-stranded) PVC insulated and unsheathed FRLS electric cable 1100 volts cable and including PVC casing and caping of suitable size (as per conductor run) with all fittings/ accessories and including PVC insulated electric cable 1100 volts 2.5 Sqmm ( multi-stranded) copper conductor single core( Green colour) cable as continuous earth wire connected to common earth dolly including CI/PVC box covered with 3 mm thick plastic laminated sheet for one light point/ fan/exhaust fan point/ Geyser point etc; controlled by one, one way switch,complete all as specified and as directed by the Engineer-in-Charge. \nMake: Havells/Plaza/Polycab \nNote : \n(i) Eye/bottle thimbles shall be used for connection in switches/sockets & MCB's in DB's without any extra cost.\n(ii) Electric rewiring should be followed by proper colour coding i.e. Red for phase, Black for neutral and Green for earth.\n | 16 | Per Point | |
35 | 35 | Socket outlet 2 in 1, 3 pin 5 Amp and 15 Amp, multipurpose complete all as specified and as directed by the Engineer-in-Charge. \n | 16 | Each | |
36 | 36 | Switch piano, flush type, single pole, one way, 15 Amp, complete all as specified and as directed by the Engineer-in-Charge. \n | 16 | Each | |
37 | 37 | PVC bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed 15mm dia GI pipe omplete all as specified and directed by Engr-in-Charge. | 22 | Each | |
38 | 38 | Stop valve, 15mm bore, cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions suitable complete, fancy type, chromium plated complete all as specified and directed by Engr-in-Charge. | 17 | Each | |
39 | 39 | Cutting existing steel tubing of 15mm bore for alterations or additions (each cut measured) complete all as specified and directed by Engr-in-Charge. | 11 | Each | |
40 | 40 | Ceiling fan, 1400 mm sweep complete with electronic type regulator and accessories 230V, BEE 5 star rated inlcuding necessary connections for making its functional, suitable clamps, nuts, bolts and downrod for hanging complete all as specified and directed by Engr-in-Charge. \nMake: Bajaj/Havells/Crompton. | 62 | Each | |
41 | 41 | Switch piano flush type single pole one way 5/6 Amp complete all as specified and as directed by Engineer-in-Charge. \nMake: Plaza /SSK/Cona/Havells | 62 | Each | |
42 | 42 | Point wiring with 1.5 Sqmm copper conductor (Multi-stranded) PVC insulated and unsheathed FRLS electric cable 1100 volts cable and including PVC casing and caping of suitable size (as per conductor run) with all fittings/ accessories and including PVC insulated electric cable 1100 volts 1.5 Sqmm ( multi-stranded) copper conductor single core( Green colour) cable as continuous earth wire connected to common earth dolly including wooden box covered with 3 mm thick plastic laminated sheet for one light point/ fan/exhaust fan point/ bell point etc controlled by one, one way switch,complete all as specified and as directed by the Engineer-in-Charge. \nMake: Havells/Plaza/Polycab \nNote : \n(i) New Sunken boxes wherever required shall be measured & paid separately. \n(ii) Eye/bottle thimbles shall be used for connection in switches/sockets & MCB's in DB's without any extra cost.\n(iii) Electric rewiring should be followed by proper colour coding i.e. Red for phase, Black for neutral and Green for Earth. | 62 | Per Pont | |
43 | 43 | Ceiling rose surface type, 65 mm x 50 mm two to three terminals / PVC / polycarbonate, isolated body fixed on PVC block complete all as specified and as directed by Engineer-in-Charge. | 62 | Each | |
44 | 44 | MCB SP 16/20 Amp breaking capacity 10KA complete all as specified and directed by the Engineer-in-Charge. \n | 12 | Each | |
45 | 45 | Cutting existing steel tubing of 20mm bore for alterations or additions (each cut measured) complete all as specified and directed by Engr-in-Charge. | 1 | Each | |
46 | 46 | Galvanised iron steel water tubing, medium grade, 20mm bore, ISI marked with screwed socket joints together with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, lugs and union etc., fixed to wall/roofs/under floors/trenches etc. complete all as specified and directed by Engr-in-charge. | 120 | RM | |
47 | 47 | Stop valve, 20mm bore, cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions suitable complete, fancy type, chromium plated complete all as specified and directed by Engr-in-Charge. | 2 | Each | |
48 | 48 | Rotational moulded polyethylene water storage tank 1000 Ltrs capacity four layered (ISI Marked) cylinderical vertical with closed top, hoisted and fixed in position with ball brass valve, high pressure with PVC float valve 20mm dia with polythene float and fly nut, tank nipples with check nuts and washers complete and making connections with existing water supply line, all as specified and directed by Engr-in-Charge.\n | 1 | Each |