Military Engineer Services-MES has published Replacement Of Oh Line Into Lt Ug Cable From Dsc Guard Room To Dsc Barrack At Nad Goa Provision Of 10Kva Voltage Stabilizer For Cold Room Cool Room At Blo Goa And Provision Of Certain Minor Works Under Ge Gomantak Vasco. Submission Date for this Tender is 20-01-2020. Voltage Stabiliser Tenders in Vasco Da Gama Goa. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 09-Jan-2020 | postpone | Date | 16-01-2020 |
2 | 17-Jan-2020 | postpone2 | Date | 20-01-2020 |
Name of Work: Replacement of OH line into LT UG cable from DSC Guard Room to DSC Barrack at NAD (Goa), Provn of 10KVA voltage stabilizer for cold room /cool room at BLO Goa and provision of certain Minor Works under GE Gomantak Vasco | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | M & L for one light point controlled by one switch with 1.5 Sqmm PVC insulated, unsheathed, single core, multi stranded, FRLS, 1100 Volts, copper conductor cable drawn in & including stove enamelled steel conduit on surface of wall and 1.5 sqmm PVC insulated, unsheathed, single core, multi stranded, FRLS, 1100 Volts copper conductor cable for earth wire including making connection with common earth and earth dolly including pressed steel terminal al boxes with 3 mm thick plastic laminated sheet top cover fixed with brass screw etc and making good disturbed surface of walls and floors to match with existing surfaces all as per specified and directed by Engr-in-Charge. | 10 | 16 | Per Point |
2 | 2 | M&L for one light point or fan point controlled by one switch with cables 1.5 Sqmm copper cable FRLS multistranded unsheathed drawn through & including casing and capping and 1.5 sqmm conductor cable for earth wire including making connection with common earth and earth dolly including pressed steel terminal al boxes concealed in wall with 3 mm thick plastic laminated sheet top cover fixed with brass screw for mounting switches sockets regulator etc all as per directed by Engr-in-Charge. | 11 | 12 | Per \nPoint |
3 | 3 | M&L for one light point or fan point controlled by one switch with cables 4 Sqmm copper cable FRLS multistranded unsheathed drawn through & including casing and capping and 4 sqmm conductor cable for earth wire including making connection with common earth and earth dolly including pressed steel terminal al boxes concealed in wall with 3 mm thick plastic laminated sheet top cover fixed with brass screw for mounting switch socket combination 15 Amps etc all as per directed by Engr-in-Charge. | 12 | 1 | Per \nPoint |
4 | 4 | Supply and fix switch piano flush type single pole, one way 5 Amp. | 13 | 18 | Each |
5 | 5 | Supply & Fixing modular switch 1 way 6A, 1 module, 230 volts. | 14 | 8 | Each |
6 | 6 | Supply & fixing modular metal flush box 1 module. | 15 | 8 | Each |
7 | 7 | Supply & fixing modular white cover plate with frame, 1 module | 16 | 8 | Each |
8 | 8 | Supply & fixing ceiling rose, surface bakelite 65x50 mm two to three terminals all as specified and directed. | 17 | 16 | Each |
9 | 9 | Supply and fix polycarbonate switch box with 02 Nos 15 Amp Switch. | 18 | 1 | Each |
10 | 10 | Supply and fix polycarbonate uni-switch socket combination 2 in 1, 3/5 pin 5/6 Amp box white with 4 fixing. Make Anchor Note: (Cost quoted is inclusive of surface mounting box and Switch socket combination) | 19 | 13 | Each |
11 | 11 | Supply and fix polycarbonate uni-switch socket combination 2 in 1, 3/5 pin 15/20 Amp box white with 4 fixing. Make Anchor or Equivalent in Other Makes having ISI marked. Note: (Cost quoted is inclusive of surface mounting box and Switch socket combination) | 20 | 20 | Each |
12 | 12 | M & L for fixing Surface mounting sockets IP 66/67, 240 Volts, 16 Amps complete. | 21 | 1 | Each |
13 | 13 | M & L for fixing Surface mounting sockets IP 66/67, 240 Volts, 32 Amps complete. | 22 | 1 | Each |
14 | 14 | Supply & Fix MCB single pole 240 Volts 6-32 Amps 10kA C Series | 23 | 24 | Each |
15 | 15 | S & Fixing MCB single pole and neutral 240 Volts 6-32 Amps 10kA C Series | 24 | 4 | Each |
16 | 16 | S & Fixing MCB single pole and neutral 240 Volts 40 Amps 10kA C Series | 25 | 4 | Each |
17 | 17 | S & Fixing MCB single pole and neutral 240 Volts 63 Amps 10kA C Series | 26 | 2 | Each |
18 | 18 | Supply and fix sheet metal enclosure (DB) SPN, 4 way, 240 V double door with 200 a rated bus bar. | 27 | 1 | Each |
19 | 19 | Supply and fix sheet metal enclosure (DB) SPN, 8 way, 240 V double door with 200 a rated bus bar. | 28 | 1 | Each |
20 | 20 | Supply & Fixing of sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 20 Amps. | 29 | 6 | Each |
21 | 21 | Supply and fix 1 row 3 module weatherproof IP 65 thermoplastic distribution board suitable for MCB's. | 30 | 2 | Ecah |
22 | 22 | Supply and fix 4/4.5 module weatherproof IP 65 thermoplastic distribution board suitable for MCB's. | 31 | 5 | Ecah |
23 | 23 | Supply and fix 9 module weatherproof IP 65 thermoplastic distribution board suitable for MCB's. | 32 | 1 | Ecah |
24 | 24 | S & F Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66, 100 watt LED flood light Complete with driver and fixing arrangements such as clamps of flat iron of suitable size ,nut ,bolts all as specified and directed by Eng-in-charge. | 33 | 4 | Each |
25 | 25 | S & F Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66, 120 watt LED flood light Complete with driver and fixing arrangements such as clamps of flat iron of suitable size ,nut ,bolts all as specified and directed by Eng-in-charge. | 34 | 2 | Each |
26 | 26 | S&F PVC sheathed 1100V grade weather proof flat twin core copper cable of size 4 Sqmm from flood light connector to switch box . Make: Finolex/Polycab/Anchor | 35 | 20 | RM |
27 | 27 | Supply & fixing exhaust fan 230mm sweep, heavy duty, 230 volts with louvers as per specified and directed by Engr-in-Charge. Make : Orient/Havells/Bajaj/Usha | 36 | 8 | Each |
28 | 28 | S & F Exhaust Fan (Metal body) Single Phase 380mm sweep with louver shutter and connecting up with electric system with & including flexible PVC copper cable three core 23/0.0076 from ceiling rose to exhaust fan and grouting of holding down bolts of suitable size in and including PCC M-15 (Nominal mix) blocks as specified. | 37 | 14 | Each |
29 | 29 | Supply and fixing FIAMMA II flameproof 2x20W LED Tubelight fixture with IP 65 protection etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. | 38 | 1 | Each |
30 | 30 | S & F Flame proof exhaust fans AC single phase 230/240 V of size 305 mm sweep with louvers incl wall opening and making good the disturbed areas all as specified. | 39 | 1 | Each |
31 | 31 | S & F Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V. | 40 | 1 | Each |
32 | 32 | Supply and fixing Submain wiring with 1.5 sqmm two runs of single core multi stranded PVC sheathed copper conductor cable 1100 FRLS 1100 Volts drawn in and including PVC casing and caping with all accessories such as tees, elbows, junction box Reducers etc as required along with one run of 1.5 Sqmm single core PVC insulated unsheathed copper conductor cable as continuous earth wire and connecting to Existing main switch board\Distribution Board and testing on completion complete all as directed. | 41 | 30 | RM |
33 | 33 | Supply and fixing Submain wiring with 2.5 sqmm two runs of single core multi stranded PVC sheathed copper conductor cable 1100 FRLS 1100 Volts drawn in and including steel enameled conduit with all accessories such as tees, elbows, junction box Reducers etc as required along with one run of 2.5 Sqmm single core PVC insulated unsheathed copper conductor cable as continuous earth wire and connecting to Existing main switch board\Distribution Board and testing on completion complete all as directed. | 42 | 12 | RM |
34 | 34 | Supply & Fixing submain wiring with 2 Runs of 4 Sqmm, PVC insulated, unsheathed, single core, multi stranded, 1100 volts, FRLS, copper conductor cable drawn in and including 25/32mm wide PVC casing and caping with all accessories such as tees, elbows, juction box, reducers etc as required along with 1 run of 4 sqmm PVC insulated, unsheathed, single core, multi stranded, FRLS, copper conductor cable as continuous earth wire and connecting to existing main switch board/Distribution Board and testing on completion including taking down old submain wiring of any type with conduit complete all as directed by Engineer-in-Charge. | 43 | 259 | RM |
35 | 35 | Supply and fix submain wiring with 2 runs of 6 sqmm, PVC insulated, unsheathed, single core, multi stranded, FRLS, 1100 Volts, copper conductor cable drawn in and incl PVC surface type caping casing with all accessories such as tees, elbows, junction box, reducers etc as required along with 1 run of 6 sqmm PVC insulated, unsheathed, single core, multi stranded, FRLS, copper conductor cable as continuous earth wire and connecting to existing main switch board \ Distribution Board and testing on completion complete all as directed by Engineer-in-charge. | 44 | 24 | RM |
36 | 36 | Taking down of split AC/Window AC from existing place and placed all Acs to store complete all as specified and directed by Engr-in-Charge. | 45 | 9 | Each |
37 | 37 | Reinstallation of split units indoor/outdoor complete all necessary fixing arrangement and accessories including mounting bracket for outdoor unit | 46 | 9 | Each |
38 | 38 | Supply and fix insulation for copper tubes of split type AC units,insulation type superion of sizen 3/8"diameter | 47 | 45 | RM |
39 | 39 | Supply and fix insulation for copper tubes of split type AC units,insulation type superion of sizen 5/8"diameter | 48 | 45 | RM |
40 | 40 | Supply and fix in repairs copper tubing soft grade suitable for split type AC suction /discharge line of size 5/8" diameter | 49 | 45 | RM |
41 | 41 | Supply and fix in repairs copper tubing soft grade suitable for split type AC suction /discharge line of size 3/8" diameter | 50 | 45 | RM |
42 | 42 | Supply, installation, commissioning of water cooler fully stainless steel, electric driven single phase having approx storage and nominal cooling capacity 40/80 Ltrs including foundation, fitting with drainage pipe up to the drain, electrical & water supply connection all as directed by Engr-in-Charge. Make : LG/Blue Star/Voltas | 51 | 1 | Each |
43 | 43 | M&L for voltage stabilizer for automatic operation single phase naturally air cooled indoor tpe and designed for input variation between 170 volt to 250 volt with output voltage stabilized at 230 volt with accuracy of +/- 2.5% for the capacity 5 KVA. Make : V-Guard/Everest/Microtech | 52 | 2 | Each |
44 | 44 | Supply & Fixing Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position of capacity 500 Ltr tank all as specified and directed. | 53 | 2 | Each |
45 | 45 | Supplying and laying of 16mm dia CPVC pipes SDR 13.5 & Plain CPVC SDR 11 fittings on wall/ceiling or laying in floor complete all as specified. | 54 | 40 | RM |
46 | 46 | Supplying and laying of 20mm dia CPVC pipes SDR 13.5 & Plain CPVC SDR 11 fittings on wall/ceiling or laying in floor complete all as specified. | 55 | 15 | RM |
47 | 47 | Supply and fix Gun-metal, globe or gate valves of 15mm, with iron wheel head, screwed both ends for pipe and fix or laying in floor complete all as specified | 56 | 1 | Each |
48 | 48 | Supply and fix Gun-metal, globe or gate valves of 20mm, with iron wheel head, screwed both ends for pipe and fix or laying in floor complete all as specified | 57 | 1 | Each |
49 | 49 | M&L for demolition of brickwork for mounting exhaust fan of 230 mm sweep | 58 | 1 | CUM |
50 | 50 | M&L for Rendering 10mm thick on fair faces of brickwork or concrete surface with cement plaster 1:4 complete. | 59 | 0.5 | SQM |
51 | 51 | Making of hole on existing wall for fixing of exhaust fan 380 mm sweep including M&L for plaster at distarbed surfaces and making good with colour wash and grouting of stud bolts etc. complete all as directed by Engineer-in-charge. | 60 | 14 | Each Job |
52 | 52 | Cutting openings, through brick walls for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks,\nremoving surplus serviceable bricks, hard-core, etc.. to store and rubbish not exc. 50m | 61 | 0.02 | CUM |
53 | 53 | Forming jambs, etc. to openings (to foregoing item), including cutting, toothing and properly\nbonding into old work, also facing, jointing and pointing to match existing work, complete | 62 | 0.22 | SQM |
54 | 54 | M&L preparation of new wall, applying a layer of Birla white wall care putty on wall and applying two coat of oil bond distemper complete all as specified and directed | 63 | 1.4 | SQM |
55 | 55 | Supply, Laying, joining & testing LT XLPE Insulated & sheathed armoured electric cables with multistranded aluminium conductor cable 1100 volts grade, laid in trenches/ ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes including cable gland of suitable sizes & aluminium lugs for connection for following size complete all as specified and directed. Make:- Polycab/Finolex/Havells | 64 | 0.0001 | SQM |
56 | 55.01 | (a) 50 Sqmm 3.5 core | 65 | 290 | RM |
57 | 55.02 | (a) 25 Sqmm 4 core | 66 | 255 | RM |
58 | 55.03 | (a) 16 Sqmm 4 core | 67 | 500 | RM |
59 | 55.04 | (a) 70 Sqmm 3.5 core | 68 | 220 | RM |
60 | 55.05 | (e) 120 Sqmm 3.5 core | 69 | 280 | RM |
61 | 55.06 | (f) 25 sqmm 3.5 core | 70 | 20 | RM |
62 | 55.07 | (g) 10 sqmm 2 core | 71 | 102 | RM |
63 | 55.08 | (h) 10 sqmm 3 core | 72 | 85 | RM |
64 | 56 | Excavation in trenches not exceeding 1.5 m width and not exc 1.5m in depth getting out in hard/dense soil | 73 | 127.19 | Cum |
65 | 57 | Excavation in trenches not exceeding 1.5 m width and not exc 1.5m in depth getting out in soft disintegrated rock | 74 | 189.49 | Cum |
66 | 58 | M & L for sand cushion in trenches for cable protection complete all as directed and specified. | 75 | 109.44 | Cum |
67 | 59 | Supply and lay PCC cable cover class LV type 1 flat size 250mmx150mmx40mm. Make : Mehtab/National | 76 | 8543 | Each |
68 | 60 | M&L for Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in thick using excavated hard/dense soil. | 77 | 190.22 | Cum |
69 | 61 | M&L for Removal of surplus soil to a distance not exceeding 50 m and depositing where directed by Engr-in-charge. | 78 | 126.44 | Cum |
70 | 62 | M & L for GI tubing (light grade) with all fittings, laid in trenches, or fixed along with walls /poles, bore of pipe 32mm. | 79 | 3 | RM |
71 | 63 | M & L for GI tubing (light grade) with all fittings, laid in trenches, or fixed along with walls /poles, bore of pipe 40mm. | 80 | 52 | RM |
72 | 64 | M & L for GI tubing (light grade) with all fittings, laid in trenches, or fixed along with walls /poles, bore of pipe 50mm. | 81 | 18 | RM |
73 | 65 | M & L for GI tubing (light grade) with all fittings, laid in trenches, or fixed along with walls /poles, bore of pipe 80mm. | 82 | 12 | RM |
74 | 66 | S & F sheet moulding compound junction (SMC) suitable for terminating 2 Nos 4 x 6/10/16 Sqmm UG cable with provn of one in Nos MCB SP 6A including cable glandes- 2 Nos, and two way connector 1 No, including dismantling old one. Make ; Sintex. | 83 | 14 | Each |
75 | 67 | Supply and installation of factory made LT panel 'KIOSK type' cubical, weather, dust and vermin proof (out door type) CRPI approved factory made suitable for operation on 1100 volts 3 phase, 4wire, 50 HZ AC electric supply, externally powder coated & internally painted with two coats of synthetic enamel paint over one coat of red-oxide primer, made out of 3mm thick CRCA steel sheet as size having opening and locking arrangement both from front and back side with cable tray of size not less than 20cm including copper busbar size 25x06 mm, fixing on angle iron size of 50x50x6mm including connected accessories and necessary PCC work 1:3 :6 type C-2 blocks complete with following accessories :-\n(i) MCCB 200 Amps 4 Pole - 01 No (Incoming).\n(ii) MCCB 100 Amps 4 pole - 01 No (Outgoing).\n(iii) MCCB 63 Amps 4 pole - 02 No (Outgoing).\n(iv) S&F multi function digital meter with LCD display incl CT having CTR 50/5\n(v) Indicators with neon lamp with RYB shade, 240 volts 50 c/s of suitable capacity resistance - 01 set.\n(vi) Internal wiring with suitable size PVC insulated single core copper cable for connecting instruments-01 lot | 84 | 1 | Each Job |
76 | 68 | Supply and installation of factory made LT panel 'KIOSK type' cubical, weather, dust and vermin proof (out door type) CRPI approved factory made suitable for operation on 1100 volts 3 phase, 4wire, 50 HZ AC electric supply, externally powder coated & internally painted with two coats of synthetic enamel paint over one coat of red-oxide primer, made out of 3mm thick CRCA steel sheet as size having opening and locking arrangement both from front and back side with cable tray of size not less than 20cm including aluminium busbar of size 25x06 mm, fixing on angle iron size of 50x50x6mm including connected accessories and necessary PCC work 1:3 :6 type C-2 blocks complete with following accessories :-\n(i) MCCB 100 Amps 4 Pole - 01 No (Incoming).\n(ii) MCCB 63 Amps 4 pole - 02 No (Outgoing).\n(iii) S&F multi function digital meter with LCD display incl CT having CTR 50/5\n(iv) Indicators with neon lamp with RYB shade, 240 volts 50 c/s of suitable capacity resistance - 01 set.\n(v) Internal wiring with suitable size PVC insulated single core copper cable for connecting instruments-01 lot | 85 | 2 | Each Job |
77 | 69 | Supply and installation of LT panel 'KIOSK type' cubical, weather, dust and vermin proof (out door type) CRPI approved suitable for operation on 1100 volts 3 phase, 4wire, 50 HZ AC electric supply, externally powder coated & internally painted with two coats of synthetic enamel paint over one coat of red-oxide primer, made out of 3mm thick CRCA steel sheet as suitable size having opening and locking arrangement both from front and rear side with cable tray of size not less than 20cm including copper busbar strip of 25 x 6 mm size 04 Nos fixing on angle iron size of 50 x 50 x 6mm including connected accessories and necessary PCC work 1:3 :6 type C-2 blocks complete with following accessories:-\n(i) MCCB 100 Amps 4 Pole 16 KA - 01 No (Incoming)\n(ii) Industrial Plug and Socket 415V, 63A, 3P + E - 01 No (Outgoing)\n(iii) S&F multi function digital meter with LCD display incl CT having CTR 50/5 (Parameters : V, A, F, PF, kW, kVA, KWh) - 01 No\n(iv) Indicators with neon lamp with RYB shade, 240 volts 50 c/s of suitable capacity resistance - 01 set\n(v) Internal FRLS wiring with suitable size PVC insulated single core copper cable for connecting instruments-01 lot. | 86 | 1 | Each |
78 | 70 | “Material and labour for earthing complete with galvanised steel earth plate electrode 600mm x 600mm x not less than 6mm, burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanised earth lead wire 4.00mm dia by means of bolts , nuts, check nuts and washers of GI/steel all as shown in electric plate No 3connected to earth test point/MCB DBs all as specified and indicated complete and including charcoal dust ,salt etc and GI protection pipe medium grade 15 mmand GI watering pipe 20mm medium grade with funnel and wire mesh,40 mm thick precast RCC M-15 (Nominal mix) cover reinforced with XPM weight not less than 4 kg/sqm with suitable handle of 6mm dia MS bar and angle iron 40x40x3mm frame for cover, PCC M-15 (Nominal mix) pit, excavation and earth work in any type of soil and connected all as specified and directed by Engineer-in-Charge.” | 87 | 5 | Each |
79 | 71 | M/L for earthing complete with steel earth plate eletrode 60cm x 60cm x6mm thick buried directly in ground vertically (earth pit not less than 2.25 mtr below ground level) with top edge of plate not less than 1.5 mtr below ground level connected to GI earth strip 25x4mm by means of bolts. nuts, check nuts and washers etc including protection pipe 15mm dia up to 7.5m length, provision the earth lead to earth connection in their main distribution box with lugs and GI nuts, bolts, earthing shall be done all as per shown electrical plate No 5 of SSR part 1 Including neccessary excavation disintergrated hard rock filling earth of 15 mm thick and privision of earth pit provision of 20mm dia with funnel, PCC earth chamber 100mm thick, precast RCC cover with suitable precast RCC frame and earth test point and testing in presence of Engr -in -Charge. | 88 | 2 | Each |
80 | 72 | M&L for earthing complete with copper plate earth plate electrode 60 cm x 60 cm x 3.15 mm thick buried directly in ground vertically to a depth not less than 2.25 m below ground level with top connected to Copper earth strip 25 x 3 mm by means of bolts, nuts, check nuts and washers of brass and earth lead connected to terminal box with including necessary and earth work and excavation including PCC chamber made up of 1:3:6 and RCC cover all as specified and or shown in electric plate No 5 of SSR-1 complete all as specified and directed by Engr-in-Charge. | 89 | 4 | Each |
81 | 73 | M&L for test point terminal block made out of gun metal 75 mm x 75 mm x 25 mm drilled and screwed including three Nos 8mm dia 25 mm long hexagonal head screws and including provision of suitable MS box made out of 3 mm thick MS sheet to accommodate the terminal block all as specified and directed by Engr-in-Charge. | 90 | 4 | Each |
82 | 74 | Supply & fixing aluminium strip 25 x 3 mm fix on Dough moulding compound insulator for roof conductors and down conductors above ground level as lighting conductor (including insulater) for building /store shed all as directed including removing the old U/S strips. | 91 | 35 | RM |
83 | 75 | Supply and fixing Air termination, single pointed Copper Rod 12mm dia and 300 mm long as specified and directed by Engr-in-Charge. | 92 | 3 | Each |
84 | 76 | Material and labour for "SERVO CONTROLLED VOLTAGE STABILIZER"(Conforming as per BIS: 9815: Part 1: 1994 reaffirmed 2009) for automatic operation, three phase, naturally oil cooled indoor type ,Unbalanced type,copper wound,Digital display type,Relay free smooth and silent operation designed for input Voltage variation between 300V to 480 V with output voltage stabilized at 415 V with accuracy +/- 1% , rated frequency 50 Hz ,No distortion in wave form,response time not to exceed 10 mili seconds, speed of corection 8 volts per second and 20 volts per second for phase to phase,Digital display Voltmeter/Ammmeter,Overload/Short circuit protections, High/low voltage cut off,Bypass arrangement in case of emergency,single phase sequence change protection, degree of protection IP 45 capacity 10 KVA including first filling of oil in servo Voltage Stabilizers Complete all as specified & Directed by Eng-in-Charge. | 93 | 1 | Each |
85 | 77 | Supply and Install Inverter AC hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with 5 star rating and EER 3.2 of capacity 1.5 TR with copper tubing condensor including inverter technology all necessary fixing arrangement and accessories including mounting bracket for outdoor unit. Make :- Bluestar/Voltas/Carrier/Daikin | 94 | 1 | Each |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy