| 1 | 1 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.(02 set x 10 DG Sets=20 sets) for 10 different BOPs) | item2 | 20 | Set |
|---|
| 2 | 2 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.(02 set x 10 DG Sets =20 sets)( for 10 different BOPs) | item3 | 20 | Set |
|---|
| 3 | 3 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.(06 mtr x 10 DG Sets =60 mtr)( for 10 different BOPs) | item4 | 60 | MTR |
|---|
| 4 | 4 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.(06 mtr x 10 DG Sets =60 mtr)( for 10 different BOPs) | item3 | 60 | MTR |
|---|
| 5 | 5 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.(05 mtr x 10 DG Sets=50 mtr)( for 10 different BOPs) | item5 | 50 | MTR |
|---|
| 6 | 6 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.(05 mtr x 10 DG Sets=50 mtr)( for 10 different BOPs) | item1 | 50 | MTR |
|---|
| 7 | 7 | Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.(1.67 cum x 10 DG Sets=16.70 cum)( for 10 different BOPs) | item5 | 16.7 | CUM |
|---|
| 8 | 8 | Providing and laying in position cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required..(1.53 cum x 10 DG Sets=15.30 cum)( for 10 different BOPs) | item2 | 15.3 | CUM |
|---|
| 9 | 9 | Providing 15mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand) at all levels.(9.96 sqm x 10 DG Sets=99.60 sqm)( for 10 different BOPs) | item3 | 99.6 | Sqm |
|---|
| 10 | 10 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. A) 3½ X 120 sq. mm (45mm)(02 set x 10 DG Sets=20 sets)( for 10 different BOPs) | item4 | 20 | Set |
|---|
| 11 | 10.1 | B) 3½ X 35 sq. mm (32mm)(02 set x 10 DG Sets=20 sets)(for 10 different BOPs) | item3 | 20 | Set |
|---|
| 12 | 11 | Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels.(2.08 cum x 10 DG Sets=20.80 cum)( for 10 different BOPs) | item5 | 20.8 | CUM |
|---|
| 13 | 12 | Supplying and Laying of control cable unarmoured 6 core 2.5 sqmm copper conductor for DG set panel to AMF control pannel direct in existing the trench etc. as required. Polycab/Havells make(33 mtr x 10 DG Sets=330 mtr)(for 10 different BOPs) | item1 | 330 | MTR |
|---|
| 14 | 13 | Unloading of DG set from truck and placing at required site with the help of crane etc as required ( as per direction of Engineer in Charge )(02 set x 10 DG Sets=20 sets)( for 10 different BOPs) | item2 | 20 | JOB |
|---|
| 15 | 14 | Placing of DG set at plateform with the help of crane etc as required ( as per direction of Engineer in Charge )(02 set x 10 DG Sets=20 sets)( for 10 different BOPs) | item3 | 20 | JOB |
|---|
| 16 | 15 | S/ITC of outdoor type feeder piller CPRI approved , double door made out of 16 SWG CRCA sheet of size 1000 mm x 1000 mm x 350 mm deep having 125 amps, 04 nos insulated aluminium bus bars and to accommodate following accessories, front & back door openable and P & F of internal connection with 10 sqmm size of Copper wires, following accessories & angle iron frame of size 1000 mm x 350 mm with 600 mm long legs made out of 40 mm x 40 mm x 5 mm thick angle & grouting the same in suitable cement concrete foundation, arrangement for incoming / outgoing cabling / cable termination, earthing, locking, interconnection with following accessories etc. as required.(01 set x 10 DG Sets=10 sets)( for 10 different BOPs) | | | |
|---|
| 17 | 15.1 | (i)4 pole, 100 Amp 18 KA MCCB CM90677OOLO with Spreader link (L&T) or equivalent make Legrand/ Schnieder / Siemens- 1 No. (ii)4 pole, 63 Amp 18 KA MCCB CM90518OOJO with , Spreader link L&Tor equivalent make Legrand/ Schnieder / Siemens- 4No. (iii)125 Amp ChangeOver,415 Volts, 50 Hz CO21250OOOO(L&T) make or equivalent specification C&S/Schenider make-01 no (iv)Indicating lights - 06 Nos (3 Nos for Incoming power supply and 3 Nos for outgoing power supply) (v)Digital ampere meter 96X96sqmm -01 no (vi)Digital Volt meter 96X96sqmm range 0-500 V-01 no (vii)Ampere meter selector switch 01 no (viii)Volt meter selector switch 01 no (ix)CT 200/5A -03 nos | item4 | 10 | each |
|---|