| 1 | 1 | Servicing of split AC of any type/size/make /model & capacity up to 3TR in any position/ work shop as convenent indoor & out door unit by cleaning of dust from condenser,airfilter, coolingcoils, by pressure pump of liquid line filter/capallary tube /expension valve, refrigerent inlet /out let pipe by Nitrogen and Etheline tri chloride(ETC),and checking of all electrical components and compressor etc. Replacement of minor part such as nut, bolts, screws, washers, brazing, lugs etc and testing proper cooling all as directed.\nNote:-\n(i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under this item. \n(ii) Gas for charging of gas, if required, shall be issued free for filling under Schedule 'B'. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item \n(iii) Contractor shall be paid only one time the labour charges quoted above in Schedule `A' items for a particular AC's repaired irrespective of the number of times labour and resources arranged by him to check the serviceability of the ACs and replacement of unserviceable / defective parts in order to maintain the ACs in serviceable/working condition. | | 200 | Each |
|---|
| 2 | 2 | Servicing of Window type AC of any type/size/make /model & capacity at any position including cleaning & washing condenser assembly by chemical such as suction air filter & coil, brazing the discharge and suction line by and checking & retightening of all electrical connections. Replacement of minor part such as nut, bolts, screws, washers incl replacment of unserviceable parts of capacity 1.5/2.0 TR of single phase etc and testing complete all as specified and directed.\nNOTE :-\n(i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under this item. \n(ii) Gas for charging of gas, if required, shall be issued free for filling under Schedule 'B'. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item (iii) Contractor shall be paid only one time the labour charges quoted above in Schedule `A' items for a particular AC's repaired irrespective of the number of times labour and resources arranged by him to check the serviceability of the ACs and replacement of unserviceable / defective parts in order to maintain the ACs in serviceable/working condition. | | 10 | Each |
|---|
| 3 | 3 | Supply only the following items of Air conditionshining split/window type AC of capacity 1.5/2/3TR of any make/model/ capacity.including checking of defects and rectified. | | | |
|---|
| 4 | 3.01 | Starting capacitor 80 mfd suitable for 240 Volts 50 HZ AC supply. | | 50 | Each |
|---|
| 5 | 3.02 | Starting capacitor 100/120 mfd suitable for 240 volts 50 HZ AC supply | | 35 | Each |
|---|
| 6 | 3.03 | Running capacitor of 36 mfd +5/6 mfd suitable for 240 volts 50 HZ AC supply | | 50 | Each |
|---|
| 7 | 3.04 | Running capacitor of 45/50/60 + 5/6 mfd suitable for 240 volts 50 HZ AC Supply | | 50 | Each |
|---|
| 8 | 3.05 | Running capcitor of 10 mfd suitable for 230 volts 50 HZ AC supply | | 25 | Each |
|---|
| 9 | 3.06 | PVC braded drain pipe of size 15 mm dia | | 50 | RM |
|---|
| 10 | 3.07 | PVC braded drain pipe of size 20 mm dia | | 50 | RM |
|---|
| 11 | 3.08 | PVC braded drain pipe of size 30 mm dia | | 50 | RM |
|---|
| 12 | 3.09 | Blower motor 1330 RPM, 32W, Single phase suitable for 230 volts of 1.5 TR split AC Make : Guangdong welling Motor Model No. RP35 B-3 or equivalent as approved. | | 12 | Each |
|---|
| 13 | 3.1 | Blower motor three speed 1/7HP to 1/5 HP 900 RPM suitable for 230 volts of 3.0 TR split AC Make : Speed King or equivalent as approved. | | 12 | Each |
|---|
| 14 | 3.11 | Copper tubing of special annealed pressure copper of size 3/8\" bore | | 25 | RM |
|---|
| 15 | 3.12 | Copper tubing of special annealed pressure copper of size 5/8\" bore | | 20 | RM |
|---|
| 16 | 3.13 | Copper tubing of special annealed pressure copper of size 1/4\" bore | | 20 | RM |
|---|
| 17 | 3.14 | Copper tubing of special annealed pressure copper of size 1/2\" bore | | 20 | RM |
|---|
| 18 | 3.15 | Over load Relay confirming to Model 85001-2/3/4/5 Make :Annapurna | | 50 | Each |
|---|
| 19 | 3.16 | Harmetic sealed Reciprocating compressor suitable for 1.5 TR 230 volts, Make : Techamsha model No. 5522E | | 5 | Each |
|---|
| 20 | 3.17 | Harmetic sealed Reciprocating compressor suitable for 1.5 TR 230 volts, Make : Emersion CR22 MK-6 | | 5 | Each |
|---|
| 21 | 3.18 | Harmetic sealed Reciprocating compressor suitable for 2.0 TR 230 volts Make :- Emersion model No. CR-30 | | 5 | Each |
|---|
| 22 | 3.19 | Harmetic sealed Reciprocating compressor suitable for 3.0 TR 415 volts Make :- Emersion model No. CR-42 | | 5 | Each |
|---|
| 23 | 3.2 | Rotary compressor suitable for 1.5 TR 230 volts 50 HZ\nMake :- Techamsha model No. 5521 | | 5 | Each |
|---|
| 24 | 3.21 | Rotary compressor suitable for 2.0 TR Make :- Techamsha or equivalent as approved | | 5 | Each |
|---|
| 25 | 3.22 | Electronic sensing unit (PCB) with hand set suitable for PCB and display unit suitable for Split AC/Window AC 1.5/2.0 TR of any capacity, model and make \n | | 50 | Each Set |
|---|
| 26 | 3.23 | Electronic sensing unit (PCB) with hand set suitable for PCB and display unit suitable for Split AC 1.5 TR of Make : LG complete all as specified and directed Make :- LG Model No. 1842 | | 8 | Each Set |
|---|
| 27 | 3.24 | Electronic sensing unit (PCB) with hand set suitable for PCB and display unit suitable for Split AC 2.0 TR of Make : LG complete all as specified and directed Make :- LG Model No. 1846 | | 8 | Each Set |
|---|
| 28 | 3.25 | Electronic sensing unit (PCB) with hand set suitable for PCB and display unit suitable for Split AC 3.0 TR (2x1.5) of any capacity, model and make | | 10 | Each Set |
|---|
| 29 | 3.26 | Electric fan motor 1/8 HP 900 RPM suitable for 3 TR split AC out door unit, three phase \n Make :- LG/Blue star/ Voltas or as per existing make of AC at site | | 10 | Each |
|---|
| 30 | 3.27 | Electric fan motor 1/10 or 1/12 HP 900 RPM, 60 Watt suitable for 1.5/2 TR split AC out door unit, single phase, Make:- LG/Bluestar/Voltas or as per existing make of AC at site. | | 10 | Each |
|---|
| 31 | 3.28 | Electric fan motor 1/10 or 1/12 HP 1400 RPM, 60 Watt suitable for 1.5/2 TR split AC out door unit, single phase, Make:- LG/Bluestar/Voltas or as per existing make of AC at site. | | 10 | Each |
|---|
| 32 | 3.29 | Electric fan motor 1/8 HP 1400 RPM suitable for 1.5/2 TR split AC out door unit, single phase, Make:- LG/Bluestar/Voltas or as per existing make of AC at site. | | 10 | Each |
|---|
| 33 | 3.3 | Blade set of fan motor of out door unit, made out of Aluminium sheet Suitable for shaft bore dia 1/2\" and fan dia 16\"/ 18\" in existing air conditioner split type | | 20 | Each Set |
|---|
| 34 | 3.31 | Blade set of fan motor of out door unit, made out of PVC Suitable for shaft bore dia 1/2\" and fan dia 16\"/ 18\" in existing air conditioner split type | | 20 | Each Set |
|---|
| 35 | 3.32 | Evaporator indoor unit body made of PVC with GI base plate suitable for 1.5TR/2TR split AC .\n | | 5 | Each |
|---|
| 36 | 3.33 | Evaporator indoor unit body made of PVC with GI base plate suitable for 3 TR split AC .\n Make :- LG/Blue Star/Voltas/Totaline/Carrier\n | | 5 | Each |
|---|
| 37 | 3.34 | Power contactor of rating 11 amps four pole suitable for 415 volts 1.5/2.0 TR split type AC having standard coil voltage of 220 volts in existing air conditioner, split type Make L&T type MNX-12 | | 20 | Each |
|---|
| 38 | 3.35 | Power contactor of rating AC-3, 40 amps three pole suitable for 415 volts with auxillary contacts 02NO+02NC 50 HZ suitable for 3.0 TR (2x1.5 TR) for split type AC having standard coil voltage of 220 volts in existing air conditioner, split type Make :- Siemens cat No. 3 TH-32 | | 20 | Each |
|---|
| 39 | 3.36 | Power contactor 35 Amps, single pole coil voltage 220 V/230V Model :- MR-I of Make : L&T or equivalent model of make as approved | | 50 | Each |
|---|
| 40 | 3.37 | Expansion valve model No. TX-2 with 05 Nos orriface including reducer size 1/2\" x 3/8\" with 02 Nos flair nuts of size 3/8\" | | 5 | Each set |
|---|
| 41 | 3.38 | Liquid line filter drier of size 3/8\" to 1/2\" suitable for 3.0 TR three phase split AC \nMake:- Sporlan /danfoss or as approved. | | 10 | Each |
|---|
| 42 | 3.39 | Pre-air filter made up of PVC for indoor unit of split AC suitable for any make and description complete | | 5 | Each |
|---|
| 43 | 3.4 | Brass service valve of 5/8\" dia with flare unit in existing air conditioner split type \n Make CAM or equivalent make as approved \n | | 10 | Each |
|---|
| 44 | 3.41 | Brass service valve of 3/8\" dia with flare unit in existing air conditioner split type\nMake CAM or equivalent make as approved | | 10 | Each |
|---|
| 45 | 3.42 | Brass service valve of 1/2\" dia with flare unit in existing air conditioner split type\nMake CAM or equivalent make as approved | | 10 | Each |
|---|
| 46 | 3.43 | Brass service valve of 1/4\" dia with flare unit in existing air conditioner split type\nMake CAM or equivalent make as approved | | 10 | Each |
|---|
| 47 | 3.44 | PVC Grills as per exisitng make of window AC\nMake :- LG/Carrier/Blue star/Feederllord | | 10 | Each |
|---|
| 48 | 3.45 | Capacitor 4/6 mfd 230 volts for blower motor of window AC | | 20 | Each |
|---|
| 49 | 3.46 | Thermostate switch with knob 230 volts for Window AC | | 15 | Each |
|---|
| 50 | 3.47 | AC electrical blower motor of 1/7 HP to 1/6 HP 230 volts 930 RPM, 3 speed Make :- Carrier/Voltas/LG/Samsung | | 15 | Each |
|---|
| 51 | 3.48 | Ventury made of thermo-coal insulation suitable for Window AC \nMake: LG/Videocon/Samsung | | 5 | Each |
|---|
| 52 | 3.49 | PVC fan blower assembly for 1.5 /2TR window / split AC's any make | | 15 | Each |
|---|
| 53 | 3.5 | Wiring kit consisting of 2.5 Sqmm copper PVC insulated stranded copper wire with copper lugs , thimbles and solder connection complete suitable for window type AC's of any make or model\n | | 10 | Each |
|---|
| 54 | 3.51 | Condenser side fan blade suitable for existing Window type AC's of make : LG/Samsung/Videocon/Carrier/Voltas | | 10 | Each |
|---|
| 55 | 3.52 | PCB plate complete with connection suitable for `DAIKIN' make of model FTK-D-50 split type AC of capacity 1.5 TR with dihumidification system, single phase | | 2 | Each Set |
|---|
| 56 | 3.53 | PCB plate complete with connection suitable for `DAIKIN' make of model FTK-D-50 split type AC of capacity 2.0 TR with dihumidification system, single phase | | 2 | Each Set |
|---|
| 57 | 3.54 | PCB plate complete with reversible connection for hot/cool ACs incl remote set suitable for split AC/Window type ACs of capacity upto 2.0 TR single phase \nMake Carrier/Voltas/Blue star/LG\nNote :- The item rate includes indoor and outdoor unit PCBs with reversible valve suitable for hot/cool split/windowAC's | | 3 | Each set |
|---|
| 58 | 3.55 | Fan motor for outdoor unit suitable for inverter type split AC 1.5/2.0 TR of existing make complete | | 3 | Each |
|---|
| 59 | 3.56 | Blower motor for indoor unit suitable for inverter type split AC 1.5/2.0 TR of existing make complete | | 3 | Each |
|---|
| 60 | 3.57 | Check valve 3/8\" dia for upto 2.0 TR capacity Split AC's Make :- Danfoss or equivalent make as approved | | 2 | Each |
|---|
| 61 | 4 | Disconnecting, dismanlting and taking out the functional air conditioner window type of any description any make and in any position 1.5/2.0 TR capacity single phase, 50 HZ and reassembling, fixing and testing the dismantled AC in new position after making necessary cutting/opening and making good in window frame of 2nd class hardwood with 6mm thick ply wood BWR grade complete all as specified and directed\nNote- (i) The rate for above items are deemed to include for transportation to any distance inside the AF area as appoved by Engr-in-charge(ii) Gas for charging of gas if required shall be measured and paid separatly under appropriate item of schedule `A'. | | 5 | Each Job |
|---|
| 62 | 5 | Disconnecting,dismantling and taking out the functional air conditioner split type of any description, any make, and in any poition single/three phase 50 HZ and reassembling, fixing and testing incl installation of AC in new position/location after making necessary cutting/opening in wall and making good to match with the existing surface complete all as specified and directed \nNote : (i) The rate for above items are deemed to include for necessary servicing, cleaning and testing of indoor/outdoor unit of AC & replacement of necessary unserviceable screws/nuts/bolts/washer/packing's etc with new one, brazing of copper pipe & provn of PVC drain pipe of suitable size & length for split AC, transpotation to any distance inside the AF area as approved by Engr-in-charge(ii) Gas for charging of gas if required shall be measured and paid seperatly under appropriate item of schedule A | | 20 | Each |
|---|
| 63 | 6 | Taking down old unserviceable MS braket of Split AC complete all as specified and directed | | 20 | Each |
|---|
| 64 | 7 | S&F MS factory made bracket with powder coated, fixed on wall with neccessory grouting MS bolts,washer duly painted and making good of disturbed surfaces, suitable for installing outdoor unit of 1.5/2.0/3.0 TR AC complete all as specified and directed | | 20 | Each |
|---|
| 65 | 8 | S&F in repair plywood 4 mm thick, grade BWR type BB, 3 ply, cut to size, made to shape and fixed in position with nails as to make the window of AC's/Desert coolers air tight complete all as specified and directed. | | 15 | Each |
|---|
| 66 | 9 | Taking down old unserviceable voltage stablizer of capacity 4 KVA/5 KVA | | 15 | Each |
|---|
| 67 | 10 | Supply and fixing voltage stablizer electronic type for automatic operation single phase naturally air cooled, indoor, type, wall mounted for input variation between 140 V to 280 V with output voltage stablized at 200V to 245 V with accuracy of + 2.5% and of capacity 5.0 KVA complete all as specified and directed Make:- Blue Bird or equivalent | | 10 | Each |
|---|
| 68 | 11 | Supply and fixing voltage stablizer electronic type for automatic operation single phase naturally air cooled, indoor type, wall mounted for input variation between 140 V to 280 V with output voltage stablized at 200V to 245 V with accuracy of + 2.5% and of capacity 4.0 KVA complete all as specified and directed\nMake:- Blue Bird or equivalent | | 5 | Each |
|---|
| 69 | 12 | M&L for MCB Plug and socket DBs with one MCB SP 25 /32 Amps, 10 KA, 'C' Series complete all as specified and directed \nMake of Plug and socket DB :- Legrand cat No. 607841 or equivalent | | 35 | Each |
|---|
| 70 | 13 | Taking down old unserviceable MCBs of any description complete all as specified and directed | | 80 | Each |
|---|
| 71 | 14 | S&F MCB 10 KA C series of following capacity complete all as specified and directed Make :- Legrand/Havells/Schneider | | | |
|---|
| 72 | 14.01 | MCB SP 25/32 Amps, 230 Volts, 10 KA 'C' Series | | 50 | Each |
|---|
| 73 | 14.02 | MCB TPN 40 Amp 415 votls , 10 KA 'C Series | | 10 | Each |
|---|
| 74 | 14.03 | MCB SPN 32 Amps, 230 Volts, 10 KA 'C' Series | | 10 | Each |
|---|
| 75 | 14.04 | MCB SPN 40 Amps, 230 Volts, 10 KA 'C' Series | | 10 | Each |
|---|
| 76 | 15 | Taking down old unserviceable submain wiring of any description and any type including making good to disturbed surfaces complete all as specified and directed | | 390 | RM |
|---|
| 77 | 16 | M&L for Sub main wiring with PVC insulated FRLS cable LT 1100 volts grade with stranded copper conductor and drawn into and incl with concealed non metalic rigid PVC coduit alongwith earth wire and connected to comman earth dolly of the following size complete all as specified and directed. Make of cable :- Havells/L&T | | | |
|---|
| 78 | 16.01 | 2x4 sqmm ( 2 single run) with one contineous wire of size 2.5 sqmm | | 150 | RM |
|---|
| 79 | 16.02 | 2x6 sqmm ( 2 single run) with one contineous wire of size 4 sqmm | | 90 | RM |
|---|
| 80 | 16.03 | 4x6 sqmm (4 single run) with two contineous wire of size 4 sqmm | | 50 | RM |
|---|
| 81 | 16.04 | 4x10 sqmm (4 single run) with two contineous wire of size 6 sqmm | | 100 | RM |
|---|
| 82 | 17 | Taking down old unserviceable PVC conduit of any size complete all as specified and directed | | 50 | RM |
|---|
| 83 | 18 | M&L for non metalic rigid PVC conduit, medium grade ISI marked of size 25mm dia fixed on angle with suitable size clamp with mahine screw incl all other accessories complete all as specifed and directed | | 50 | RM |
|---|
| 84 | 19 | Taking down old unserviceable PVC cable of any conductor and any core complete all as specified and directed | | 150 | RM |
|---|
| 85 | 20 | S&F PVC insulated & sheathed copper round cable 1100 volts of following size incl copper thimble/pin type lugs connecting both side and testing complete all as specified and directed. Make :- L&T/Havells | | | |
|---|
| 86 | 20.01 | Size 2.5 sqmm 6 core | | 50 | RM |
|---|
| 87 | 20.02 | Size 2.5 sqmm 3 core | | 50 | RM |
|---|
| 88 | 20.03 | Size 4.0 Sqmm 3 core | | 50 | RM |
|---|
| 89 | 21 | S&F in replacement of worn out insulating material suitable for copper tubing of split AC's of following sizes complete all as specified and directed:- | | | |
|---|
| 90 | 21.01 | Internal bore 3/8\" and thickness 1/4\". | | 150 | RM |
|---|
| 91 | 21.02 | Internal bore 5/8\" and thickness 1/4\" | | 150 | RM |
|---|
| 92 | 21.03 | Internal bore 3/4\" and thickness 1/4\" | | 150 | RM |
|---|
| 93 | 21.04 | Internal bore 1/2\" and thickness 1/4\" | | 150 | RM |
|---|
| 94 | 21.05 | Internal bore 1/4\" and thicel wags 1/4\"\nMake:- Totalive/Century flex | | 150 | RM |
|---|
| 95 | 22 | Dismantling disconnecting connection refregerent pipe from outdore/ indoor unit, taking outdoor unit of split AC 1.5/2TR from wall at 30 ft height safely carried out servicing , reinstalling on roof/ on wall at suitable height/ on angle iron frame including additional copper tubing of suitable existing pipe, 3 core pvc cable Brazing, pcc on roof, bracet on wall/ angle iron wall and testing compleat all as specified directed | | 20 | Each Job |
|---|
| 96 | 23 | Taking down old unserviceable MCCB DB/MCB DB/MCCBs of any description complete | | 8 | Each |
|---|
| 97 | 24 | M&L for MCCB TPN DB double door 4 way (IP-43 Protection) complete all as specified and directed Make : Legrand cat No. 607751 or equivalent in Schneider | | 1 | Each |
|---|
| 98 | 25 | M&L for MCCB TPN DB double door 6 way (IP-43 Protection) complete all as specified and directed Make : Legrand cat No. 607750 or equivalent in Schneider | | 1 | Each |
|---|
| 99 | 26 | M&L for MCCB 3 pole 415V, fixed type 100 Amps with breaking capacity 25 KA complete all as specified and directed Make :- Legrand cat No. 420005 or equivalent in Schneider | | 3 | Each |
|---|
| 100 | 27 | M&L for MCCB 3 pole 415V, fixed type 160 Amps with breaking capacity 25 KA complete all as specified and directed Make :- Legrand cat No. 420087 or equivalent in Schneider | | 2 | Each |
|---|
| 101 | 28 | M&L for MCCB 3 pole 415V, fixed type 250 Amps with breaking capacity 36 KA complete all as specified and directed Make :- Legrand cat No. 420208 or equivalent in Schneider | | 1 | Each |
|---|