Housing Urban and Rular Development Government Departments Closing in 0 days TDR #22973877

Construction Of Model Urban P . S . With Force Barrack And Canteen With Boundary Wall , Gate With Security Post , Internal Road And External Electrification At Naihati Under Barrackpore Police Commissionerate . ( 1St Call )

Issued by Government Departments · Naihati, West Bengal
Tender Value
6.83 Crore
Estimated cost
Bid Submission
14 Jan 2020
0 days left
EMD
13.66 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Naihati → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of Model Urban P . S . With Force Barrack And Canteen With Boundary Wall , Gate With Security Post , Internal Road And External Electrification At Naihati Under Barrackpore Police Commissionerate . ( 1St Call )

BOQ

Name of Work: Construction of Model urban P.S. with Force Barrack and Canteen with Boundary Wall, Gate with Security post, Internal Road and External Electrification at Naihati under Barrackpore Police Commissionerate.
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Civil and Electrical Items of workBI01010001010000000000000515BI0100001112
22Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed.BI01010001010000000000000515BI01000011131098.34SqM
33Earth work in excavation of foundation trenches of drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing spreading or stacking the spoils with in a lead of 75m. As directed. The item includes necessary trim-ming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water etc. as required complete. Depth of excavation not execeeding 1,500 mmBI01010001010000000000000515BI01000011141749.57CuM.
44Earth work in excavation of foundation trenches of drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing spreading or stacking the spoils with in a lead of 75m. As directed. The item includes necessary trim-ming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water etc. as required complete. Depth of excavation execeeding 1,500 mmBI01010001010000000000000515BI0100001115630.452CuM.
55Earth work in filling in foundation trenches or plinth with good earth, in layer not exceeding 150mm including watering and ramming etc. layer by layer complete a) With earth obtained from excavation of foundation.BI01010001010000000000000515BI01000011161878.14CuM.
66Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consoliding the same by through saturation with water ramming complete including the cost of supply of sand (payment to be made on measurment of finished quantity) Flooring BaseBI01010001010000000000000515BI0100001117418.218CuM.
77Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level, and filling joints with powdered or local sand.BI01010001010000000000000515BI0100001118713.084SqM
88Cement concrete with graded stone ballast (40 mm size excluding shuttering)\n(A) [Pakur Variety]\n1:3:6 proportion\nBI01010001010000000000000515BI0100001119116.465CuM.
99Providing Bored Cast-in-situ M25 grade R.C.C. pile in position as per specifications in all kinds of soil including cost of boring using drilling mud to stabilize the bore and flushing the bore of excess mud with freshly prepared drilling fluid by using pumps prior to placing concrete by tremie pipe in one continuous operation and excluding the cost of all materials and labour for placing of concrete and also including the cost of mobilization and hire charges of all equipment necessary for boring, welding of reinforcement cage as necessary and lowering of reinforcement cage, preparation and placing of concrete, including the cost of concrete but excluding the cost of reinforcement and labour for bending binding etc. complete as per Drawing and Technical Specifications and removal of excavated earth with all lifts and lead upto 1000 m. Work to be executed as per IS: 2911 (Part II Sec 2).\n(a) Using tripod, winches\nii) Pile diameter - 500 mm.BI01010001010000000000000515BI01000011205522Mtr.
1010Removal of mud/sludge/slurry/liquid earth obtained during piling work from the working site and disposal of the same beyond the KMC/Municipal or any suitable area with conformity of Municipal Corporation Rules using tanker including loading and unloading the same with pump, clearing the site complete in all respect as per direction of the Engineer-in-charge. For 500mm PileBI01010001010000000000000515BI01000011215522Mtr.
1111Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture] (b) M 25 Grade\nFOUNDATION & GROUND FLOORBI01010001010000000000000515BI01000011221790.3CuM.
1212Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture] (b) M 25 Grade\nFIRST FLOORBI01010001010000000000000515BI0100001123187.393CuM.
1313Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture] (b) M 25 Grade\nSECOND FLOORBI01010001010000000000000515BI0100001124150.219CuM.
1414Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture] (b) M 25 Grade\nTHIRD FLOORBI01010001010000000000000515BI010000112521.491CuM.
1515Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) When the height of a particular floor is more than 4 m the equivalent floor\nheight shall be taken as 4 m and extra for works beyond the initial 4 m ht. shall be allowed under 12 (e) for every 4 m or part thereof)\n9 to 12 mm thick approved quality ply board shuttering\nin any concrete work\nFOUNDATION & GROUND FLOORBI01010001010000000000000515BI01000011268216SqM.
1616Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) When the height of a particular floor is more than 4 m the equivalent floor\nheight shall be taken as 4 m and extra for works beyond the initial 4 m ht. shall be allowed under 12 (e) for every 4 m or part thereof)\n9 to 12 mm thick approved quality ply board shuttering\nin any concrete work\nFIRST FLOORBI01010001010000000000000515BI0100001127845.73SqM.
1717Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) When the height of a particular floor is more than 4 m the equivalent floor\nheight shall be taken as 4 m and extra for works beyond the initial 4 m ht. shall be allowed under 12 (e) for every 4 m or part thereof)\n9 to 12 mm thick approved quality ply board shuttering\nin any concrete work\nSECOND FLOORBI01010001010000000000000515BI0100001128663.154SqM.
1818Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) When the height of a particular floor is more than 4 m the equivalent floor\nheight shall be taken as 4 m and extra for works beyond the initial 4 m ht. shall be allowed under 12 (e) for every 4 m or part thereof)\n9 to 12 mm thick approved quality ply board shuttering\nin any concrete work\nTHIRD FLOORBI01010001010000000000000515BI010000112995.09SqM.
1919Labour for Chipping of concrete surface before taking up Plastering work.BI01010001010000000000000515BI01000011309429.24SqM.
202040 mm. thick damp proof course with cement concrete(1:1.5:3) (with graded stone chips 20 mm nominal size) with water proofing compound of approved brand @ 0.2% weight of cement including cost of materials over two coats of nontoxic acrylic polymer modified cementitious waterproofing\nslurry coat complete [cost of water proofing compound and non toxic paint to be paid seperately) for underground water retaining structures.BI01010001010000000000000515BI0100001131127.342SqM.
2121(b) Applying 2 coats of Non-Toxic Acrylic Polymer modified Paint having adhesive & waterproofing properties by mixing in proportion (1 liquid: 4 cementitious material) or as per manufacturer's specification for water proofing layer in water tank etc. (No Departmental Cement is required)BI01010001010000000000000515BI0100001132632SqM.
2222Reinforcement for reinforced concrete work in all sorts structure including distribution bars, stirrups, binders etc. including of rods initial straightening and removal of loose rust (if necessary), cutting to requisite length , hooking and bending with 16 gauge black annealed wire at every inter section, complete as per drawing and direction.\nI. SAIL/TATA/RINL\nFOUNDATION & GROUND FLOORBI01010001010000000000000515BI0100001133182.945M.T.
2323Reinforcement for reinforced concrete work in all sorts structure including distribution bars, stirrups, binders etc. including of rods initial straightening and removal of loose rust (if necessary), cutting to requisite length , hooking and bending with 16 gauge black annealed wire at every inter section, complete as per drawing and direction.\nI. SAIL/TATA/RINL\nFIRST FLOORBI01010001010000000000000515BI010000113422.487M.T.
2424Reinforcement for reinforced concrete work in all sorts structure including distribution bars, stirrups, binders etc. including of rods initial straightening and removal of loose rust (if necessary), cutting to requisite length , hooking and bending with 16 gauge black annealed wire at every inter section, complete as per drawing and direction.\nI. SAIL/TATA/RINL\nSECOND FLOORBI01010001010000000000000515BI010000113518.026M.T.
2525Reinforcement for reinforced concrete work in all sorts structure including distribution bars, stirrups, binders etc. including of rods initial straightening and removal of loose rust (if necessary), cutting to requisite length , hooking and bending with 16 gauge black annealed wire at every inter section, complete as per drawing and direction.\nI. SAIL/TATA/RINL\nTHIRD FLOORBI01010001010000000000000515BI01000011362.364M.T.
2626Brick work with 1st class bricks in cement mortar (1:6)\n(a) In foundation and plinthBI01010001010000000000000515BI010000113788.742CuM.
2727Brick work with 1st class bricks in cement mortar (1:6)\nGROUND FLOOR (Super Structure)BI01010001010000000000000515BI0100001138121.87CuM.
2828Brick work with 1st class bricks in cement mortar (1:4) in\nIn superstructure, ground floorBI01010001010000000000000515BI010000113977.97CuM.
2929Brick work with 1st class bricks in cement mortar (1:6)\nFIRST FLOORBI01010001010000000000000515BI0100001140118.674CuM.
3030Brick work with 1st class bricks in cement mortar (1:6)\nSECOND FLOORBI01010001010000000000000515BI010000114190.586CuM.
3131Brick work with 1st class bricks in cement mortar (1:6)\nTHIRD FLOORBI01010001010000000000000515BI010000114220.242CuM.
3232125 mm. thick brick work with 1st class bricks in cement mortar (1:4)in\nGROUND FLOORBI01010001010000000000000515BI0100001143385.806SqM
3333125 mm. thick brick work with 1st class bricks in cement mortar (1:4)in\nFIRST FLOORBI01010001010000000000000515BI0100001144465.798SqM
3434125 mm. thick brick work with 1st class bricks in cement mortar (1:4)in\nSECOND FLOORBI01010001010000000000000515BI0100001145414.337SqM
3535125 mm. thick brick work with 1st class bricks in cement mortar (1:4)in\nTHIRD FLOORBI01010001010000000000000515BI0100001146113.31SqM
3636Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]\n(ii) With 1:4 cement mortar ,\nb) 10 mm thick plaster. Ceiling Plaster\nGROUND FLOORBI01010001010000000000000515BI0100001147709.21SqM
3737Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]\n(ii) With 1:4 cement mortar ,\nb) 10 mm thick plaster. Ceiling Plaster\nFIRST FLOORBI01010001010000000000000515BI0100001148681.17SqM
3838Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]\n(ii) With 1:4 cement mortar ,\nb) 10 mm thick plaster. Ceiling Plaster\nSECOND FLOORBI01010001010000000000000515BI0100001149555.36SqM
3939Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]\n(ii) With 1:4 cement mortar ,\nb) 10 mm thick plaster. Ceiling Plaster\nTHIRD FLOORBI01010001010000000000000515BI010000115049SqM
4040Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]\nWith 6:1 cement mortar \na) 20mm thick plaster OUTSIDE\nGROUND FLOORBI01010001010000000000000515BI01000011511389.64SqM
4141Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]\nWith 6:1 cement mortar \na) 20mm thick plaster OUTSIDE\nFIRST FLOORBI01010001010000000000000515BI0100001152588SqM
4242Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]\nWith 6:1 cement mortar \na) 20mm thick plaster OUTSIDE\nSECOND FLOORBI01010001010000000000000515BI0100001153594.77SqM
4343Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]\nWith 6:1 cement mortar \na) 20mm thick plaster OUTSIDE\nTHIRD FLOORBI01010001010000000000000515BI0100001154701.8SqM
4444Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]\nWith 6:1 cement mortar \nb) 15mm thick plaster INSIDE\nGROUND FLOORBI01010001010000000000000515BI01000011553603.29SqM
4545Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]\nWith 6:1 cement mortar \nb) 15mm thick plaster INSIDE\nFIRST FLOORBI01010001010000000000000515BI01000011562964.36SqM
4646Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]\nWith 6:1 cement mortar \nb) 15mm thick plaster INSIDE\nSECOND FLOORBI01010001010000000000000515BI01000011572335.08SqM
4747Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]\nWith 6:1 cement mortar \nb) 15mm thick plaster INSIDE\nTHIRD FLOORBI01010001010000000000000515BI0100001158419.25SqM
4848Neat Cement Punning above 1.5mm thick in Wall dado,Window Sill Floor and Drain etc Note Cement 0.152 cum 100 Sqmts\nALL FLOORBI01010001010000000000000515BI0100001159142.8SqM
4949Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick)\nALL FLOORSBI01010001010000000000000515BI01000011606401.85SqM
5050Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. Two Coats\nSolvent based interior grade Acrylic Primer\nALL FLOORBI01010001010000000000000515BI010000116111316.7SqM
5151Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty\n(to be done under specific instruction of Superintending Engineer) :\n(Two coats)\nStandard Quality\nALL FLOORSBI01010001010000000000000515BI010000116211316.7SqM
5252Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (Two coats)\nGROUND FLOORBI01010001010000000000000515BI01000011631389.64SqM
5353Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (Two coats)\nFIRST FLOORBI01010001010000000000000515BI0100001164588SqM
5454Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (Two coats)\nSECOND FLOORBI01010001010000000000000515BI0100001165594.77SqM
5555Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (Two coats)\nTHIRD FLOORBI01010001010000000000000515BI0100001166447.4SqM
5656Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.\n (Two Coat)\nNormal Acrylic Emulsion\nGROUND (External surface )BI01010001010000000000000515BI01000011671389.64SqM
5757Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.\n (Two Coat)\nNormal Acrylic Emulsion\nFIRST FLOORBI01010001010000000000000515BI0100001168588SqM
5858Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.\n (Two Coat)\nNormal Acrylic Emulsion\nSECOND FLOORBI01010001010000000000000515BI0100001169594.77SqM
5959Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer's specification. \n(b) Two coats \nTHIRD FLOORBI01010001010000000000000515BI0100001170447.4SqM
6060Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). \nSal : Malaysian Sal\nGROUND FLOORBI01010001010000000000000515BI01000011710.793CuM.
6161Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). \nSal : Malaysian Sal\nFIRST FLOORBI01010001010000000000000515BI01000011720.912CuM.
6262Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). \nSal : Malaysian Sal\nSECOND FLOORBI01010001010000000000000515BI01000011730.549CuM.
6363Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wideeach and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneerscomplete, including fitting, fixing shutters inposition but excluding the cost of hinges andother fittings.\n(b) 32 mm thick shutters (single leaf)\nGROUND FLOOR\nBI01010001010000000000000515BI010000117442.21SqM
6464Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wideeach and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneerscomplete, including fitting, fixing shutters inposition but excluding the cost of hinges andother fittings.\n(b) 32 mm thick shutters (single leaf)\nFIRST FLOORBI01010001010000000000000515BI010000117549.77SqM
6565Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wideeach and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneerscomplete, including fitting, fixing shutters inposition but excluding the cost of hinges andother fittings.\n(b) 32 mm thick shutters (single leaf)\nSECOND FLOORBI01010001010000000000000515BI010000117624.57SqM
6666Supplying fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core so as to import monolitaheic composite structure as per approved technology of Departmant of Science (DST) to satisfy IS : 4020 door testing performance . ii) 66mm X 90 mmBI01010001010000000000000515BI0100001177227.7mtr
6767Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria.(ii) 32 mm thick\nGround floorBI01010001010000000000000515BI010000117812.6SqM
6868Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria.(ii) 32 mm thick\n1st floorBI01010001010000000000000515BI010000117928.35SqM
6969Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria.(ii) 32 mm thick\n2nd floorBI01010001010000000000000515BI010000118031.5SqM
7070Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria.(ii) 32 mm thick\n3rd floorBI01010001010000000000000515BI01000011813.78SqM
7171Primming One coat on Timber or Plaster surface with Synthetic Oil bound Primer of approved Quality inclusing smooting surface by sand Papering etc\nALL FLOORSBI01010001010000000000000515BI0100001182174.825SqM
7272Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.BI01010001010000000000000515BI0100001183184.719SqM
7373Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :\nOn timber or plastered surface :With super gloss (hi-gloss) - \n(iv) Two coats (with any shade except white)BI01010001010000000000000515BI0100001184174.825SqM
7474Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :\niv) On Steel and other Metal Surface \nTwo coat with any shade except whiteBI01010001010000000000000515BI0100001185184.719SqM
7575Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick\ncement slurry at back side of tiles using cement @ 2.91\nKg/Sq.m & joint filling using white cement slurry @\n0.20kg/Sq.m.\n(a) Area of each tile upto 0.09 Sq.m \n(i) Coloured decorative at Wall\nGROUND FLOORBI01010001010000000000000515BI010000118689.483SqM
7676Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick\ncement slurry at back side of tiles using cement @ 2.91\nKg/Sq.m & joint filling using white cement slurry @\n0.20kg/Sq.m.\n(a) Area of each tile upto 0.09 Sq.m \n(i) Coloured decorative at Wall\nFIRST FLOORBI01010001010000000000000515BI0100001187175.178SqM
7777Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc(B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick\ncement slurry at back side of tiles using cement @ 2.91\nKg/Sq.m & joint filling using white cement slurry @\n0.20kg/Sq.m.\n(a) Area of each tile upto 0.09 Sq.m \n(i) Coloured decorative at Wall\nSECOND FLOORBI01010001010000000000000515BI0100001188178.613SqM
7878Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m \n(a) Area of each tile upto 0.09 Sq.m \n(i) Coloured decorative at FLOOR\nGROUND FLOORBI01010001010000000000000515BI010000118930.316SqM
7979Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m \n(a) Area of each tile upto 0.09 Sq.m \n(i) Coloured decorative at FLOOR\nFIRST FLOORBI01010001010000000000000515BI010000119065.618SqM
8080Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m \n(a) Area of each tile upto 0.09 Sq.m \n(i) Coloured decorative at FLOOR\nSECOND FLOORBI01010001010000000000000515BI010000119166.256SqM
818118 mm. to 22 mm. thick, kota stone slab set in 20 mm thick(avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing\nwork. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0kg/Sq.m]\nGROUND FLOORBI01010001010000000000000515BI0100001192549.83SqM
828218 mm. to 22 mm. thick, kota stone slab set in 20 mm thick(avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing\nwork. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0kg/Sq.m]\nFIRST FLOORBI01010001010000000000000515BI0100001193547.946SqM
838318 mm. to 22 mm. thick, kota stone slab set in 20 mm thick(avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing\nwork. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0kg/Sq.m]\nSECOND FLOORBI01010001010000000000000515BI0100001194419.925SqM
848418 mm. to 22 mm. thick, kota stone slab set in 20 mm thick(avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing\nwork. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0kg/Sq.m]\nTHIRD FLOORBI01010001010000000000000515BI01000011959.45SqM
8585Supplying, fitting and fixing 18 mm. to 22 mm. thick kota stone slab in wall, dado in 15 mm thick [avg] cement mortar (1:3) including making suitable arrangement to hold the stone properly by brass / copper hooks including pointing in cement mortar (1:2) (1 cement : 2 marble dust) with admixture of\npigments matching the stone shade, including grinding and polishing all complete as per direction of Engineer-in-charge including cost of materials, labour, scaffolding, staging, curing complete.\n[Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m]\nGROUND FLOOR\nBI01010001010000000000000515BI010000119655.32SqM
8686Supplying, fitting and fixing 18 mm. to 22 mm. thick kota stone slab in wall, dado in 15 mm thick [avg] cement mortar (1:3) including making suitable arrangement to hold the stone properly by brass / copper hooks including pointing in cement mortar (1:2) (1 cement : 2 marble dust) with admixture of\npigments matching the stone shade, including grinding and polishing all complete as per direction of Engineer-in-charge including cost of materials, labour, scaffolding, staging, curing complete.\n[Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m]\nFIRST FLOOR\nBI01010001010000000000000515BI010000119779.853SqM
8787Supplying, fitting and fixing 18 mm. to 22 mm. thick kota stone slab in wall, dado in 15 mm thick [avg] cement mortar (1:3) including making suitable arrangement to hold the stone properly by brass / copper hooks including pointing in cement mortar (1:2) (1 cement : 2 marble dust) with admixture of\npigments matching the stone shade, including grinding and polishing all complete as per direction of Engineer-in-charge including cost of materials, labour, scaffolding, staging, curing complete.\n[Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m]\nSECOND FLOOR\nBI01010001010000000000000515BI010000119867.813SqM
8888Supplying, fitting and fixing 18 mm. to 22 mm. thick kota stone slab in wall, dado in 15 mm thick [avg] cement mortar (1:3) including making suitable arrangement to hold the stone properly by brass / copper hooks including pointing in cement mortar (1:2) (1 cement : 2 marble dust) with admixture of\npigments matching the stone shade, including grinding and polishing all complete as per direction of Engineer-in-charge including cost of materials, labour, scaffolding, staging, curing complete.\n[Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m]\nTHIRD FLOOR\nBI01010001010000000000000515BI01000011992.67SqM
8989Extra cost of labour for prefinished and premoulded Nosing to treads of steps, railing, window sill etc. of Kota Stone.BI01010001010000000000000515BI0100001200162RM
9090Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg..............\n(I) With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment.\nDeep Colour & White\nGROUND FLOORBI01010001010000000000000515BI010000120141.99SQM
9191Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing.\nGROUND FLOORBI01010001010000000000000515BI010000120215.12sqm
9292Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing.\nFIRST FLOORBI01010001010000000000000515BI010000120315.12sqm
9393Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing.\nSECOND FLOORBI01010001010000000000000515BI010000120415.12sqm
9494Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing.\nTHIRD FLOORBI01010001010000000000000515BI01000012050.343sqm
9595Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & upto 6\nm height for external wall)\n3mm thick (weight 7.4kg/sqm)BI01010001010000000000000515BI010000120645.703SQM
9696Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes.\nPakur varietyBI01010001010000000000000515BI010000120765.54Cum
9797Supplying dividing strip fitted and fixed with cement mortar(1:3) in mosaic or patent stone floor, dado etc. complete as per direction of the Engineer-in-charge. Glass - 3mm. thick\n37 mm. wide stripBI01010001010000000000000515BI01000012081174.95mtr
9898Extra rate for using water proofing and plasticising admixture @ 0.2% by weight of cement (or at manufacturer's specified rate) for concrete of various grades.BI01010001010000000000000515BI010000120919.752kg
9999a) M.S. or W.I. Ornamental grill of approved design joints continuously welded with M.S,W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.\n(i) Grill weighing above 16 Kg./sq. Mtr \nGROUND FLOORBI01010001010000000000000515BI010000121019.334Qntl
100100a) M.S. or W.I. Ornamental grill of approved design joints continuously welded with M.S,W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.\n(i) Grill weighing above 16 Kg./sq. Mtr \nFIRST FLOORBI01010001010000000000000515BI01000012118.114Qntl
101101a) M.S. or W.I. Ornamental grill of approved design joints continuously welded with M.S,W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.\n(i) Grill weighing above 16 Kg./sq. Mtr \nSECOND FLOORBI01010001010000000000000515BI01000012128.016Qntl
102102a) M.S. or W.I. Ornamental grill of approved design joints continuously welded with M.S,W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.\n(i) Grill weighing above 16 Kg./sq. Mtr \nTHIRD FLOORBI01010001010000000000000515BI01000012130.1728Qntl
103103Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side\nframe), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film\nNatural whiteBI01010001010000000000000515BI0100001214408.044KG
104104Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987.\n4mm thickBI01010001010000000000000515BI010000121562.776SQM
105105Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987.\n12mm thick cleared toughened glass coforming to IS: 2553-1992 (Part-II)BI01010001010000000000000515BI010000121613.95SQM
106106Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. IN GROUND FLOORBI01010001010000000000000515BI010000121712.6SqM
107107Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-in-charge. Weight of Strainless Steel railing per metre 6.5 Kg (approx)BI01010001010000000000000515BI010000121840Mtr.
108108Supplying fitting and fixing 600 mm (+/- 30 mm) diametre R.B.T (Reinforced Barbed Tape) Concertina fencing on wall top using concertina coils stretched to approx.6 meters length at site clipped with two nos. of horizontal R.B.T strands which will be tensioned and fixed with the vertical M.S angle iron posts by means of security fasteners (such as 'C' clips, R.B.T clips etc.)BI01010001010000000000000515BI0100001219430Mtr
109109Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately). (a) 40mm X 6mm, 250mm LengthBI01010001010000000000000515BI0100001220500Each
110110Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark 100mm X 50mm X 1.25mmBI01010001010000000000000515BI0100001221401Each
111111Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting. 250mm longBI01010001010000000000000515BI0100001222130Each
112112(i) Brass floor door stopper.BI01010001010000000000000515BI0100001223130Each
113113Anodised aluminium barrel / tower /socket bolt (full covered) of approved manufractured from extructed section conforming to I.S. 204/74 fitted with cadmium plated screws. \n150 mm long X 10mm dia bolt.BI01010001010000000000000515BI0100001224250Each
114114Anodised aluminium barrel / tower /socket bolt (full covered) of approved manufractured from extructed section conforming to I.S. 204/74 fitted with cadmium plated screws. \n300 mm long X 10mm dia bolt.BI01010001010000000000000515BI0100001225100Each
115115Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete:\n(a) With continuous plate base (Hexagonal / Round rod) \n125 mm grip x 12 mm dia rod.BI01010001010000000000000515BI0100001226250Each
116116Godrej Hydraulic door closer fitted and fixed complete.Medium TypeBI01010001010000000000000515BI0100001227130Each
117117Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem mad (a) For Exposed Work -- PVC Pipes (Dia)40 mmBI01010001010000000000000515BI0100001228160Mtr.
118118Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem mad (a) For Exposed Work -- PVC Pipes (Dia) 32mmBI01010001010000000000000515BI0100001229210Mts
119119Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem mad (a) For Exposed Work -- PVC Pipes (Dia) 25 mmBI01010001010000000000000515BI0100001230330Mtr.
120120Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem mad (b) For Concealed work 15 mmBI01010001010000000000000515BI0100001231320Mtr.
121121Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem mad (b) For Concealed work 20 mmBI01010001010000000000000515BI0100001232250Mtr.
122122Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem mad (b) For Concealed work 25 mmBI01010001010000000000000515BI0100001233160Mtr.
123123Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.). 40mmBI01010001010000000000000515BI010000123415Each
124124Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.). 32 mmBI01010001010000000000000515BI010000123519Each
125125Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.). 25 mmBI01010001010000000000000515BI010000123632Each
126126Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.). 20 mmBI01010001010000000000000515BI010000123730Each
127127Supplying, fitting and fixing Anglo-Indian W.C. in white glazed vitreous china ware of approved make complete in position with necessary bolts, nuts etc. Hindware/ Parryware / Cera, made (a) With 'P' trapBI01010001010000000000000515BI010000123827Each
128128Supplying, fitting and fixing Orissa Pattern water closet with white glazed vitreous china ware of approved make in position complete excluding P or S trap (excluding cost of concrete for Fixing) a)580mm x 440 mmBI01010001010000000000000515BI01000012394Each
129129Supplying, fitting and fixing Closet seat of approved make with lid and C.P.hinges, rubber buffer and brass screws complete. (b) Anglo Indian (ii) Plastic (hallow type) whiteBI01010001010000000000000515BI010000124027Each
130130Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.WhiteBI01010001010000000000000515BI010000124129Each
131131Supplying, fitting and fixing vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 32 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. (ii) 450 mm X 300 mm sizeBI01010001010000000000000515BI010000124235Each
132132Supplying, fitting and fixing pedestal of approved make for wash basin (white)BI01010001010000000000000515BI010000124335Each
133133Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete. ii) 470 mm X 280 mm X 340 mmBI01010001010000000000000515BI010000124415Each
134134Supplying, fitting and fixing porcelain partition wall of approved make of size 618 mm X 310 mm complete in all respect.BI01010001010000000000000515BI010000124513Each
135135Supplying, fitting and fixing urinal flush pipe fittings and approved brand. a) C.P. Urinal flush pipe fittings range of one.BI01010001010000000000000515BI010000124615Each
136136Supplying,fitting and fixing 32 mm dia. with necessary fixing materials and clamps complete. Polythene Flush Pipe.BI01010001010000000000000515BI010000124750Each
137137Supplying, fitting and fixing approved brand 32 mm dia. P.V.C. waste pipe, with coupling at one end fitted with necessary clamps. 1050 mm longBI01010001010000000000000515BI010000124837Each
138138Supplying, fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia. (iv) 750 mm longBI01010001010000000000000515BI010000124966Each
139139Supplying , Fitting & Fixing pillar cock of approved make (a) CP Pillar cock -15 mm (code no. 5011 & model FLORENTINE of JAQUAR or equivalentBI01010001010000000000000515BI010000125035Each
140140Supplying ,fitting and fixing bib cock or stop cock. chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar).BI01010001010000000000000515BI010000125170Each
141141Supplying ,fitting and fixing bib cock or stop cock. chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513 (B) Model - Tropical / Sumthing Special of ESSCO or similar).BI01010001010000000000000515BI010000125270Each
142142Chromium plated angular stop cock with wall flange (Equivalent to code no. 5053 & model - Florentine of Jaquar or similar brandBI01010001010000000000000515BI010000125370Each
143143Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mmBI01010001010000000000000515BI010000125435Each
144144Supplying, fitting and fixing shower of approved brand.Chromium plated round shower with revolving joint 100 mm dia with rubid cleaning system (Equivalent to Code No. 542(N) & Model -Tropical / Sumthing Special of ESSCO or similar brand).BI01010001010000000000000515BI010000125519Each
145145Hand Shower(Health Faucet) with 1mtr Fexible Tube with Wall Hook(Equivalent to Code No.573 & Model -ALLIED of Jaquar or similar).BI01010001010000000000000515BI010000125628Each
146146Supplying, fitting and fixing towel rail with two brackets. C.P. over brass 25 mm dia. and 600 mm longBI01010001010000000000000515BI010000125732Each
147147Suppling fitting fixing liquid soap container b) PTMT (Prayag or Equivelent)BI01010001010000000000000515BI010000125835Each
148148Suppling fitting fixing soap holder a) PTMT (Prayag or Equivelent)BI01010001010000000000000515BI010000125935Each
149149Supplying fitting fixing PTMT smart shelf of approved make of size 300 mmBI01010001010000000000000515BI010000126035Each
150150Supplying, fitting and fixing C.I. round grating. (ii) 150 mm diaBI01010001010000000000000515BI010000126160Each
151151Supplying, fitting and fixing C.I. square jalli. (ii) 150 mmBI01010001010000000000000515BI010000126230Each
152152Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992 (A) (i) Single Socketed 3 Mtr. Length b) 110 mmBI01010001010000000000000515BI0100001263320Mtr.
153153Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992 Fittings (110 MM)(i) Door Tee (110 mm)BI01010001010000000000000515BI010000126455Each
154154Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992 Fittings (110 MM) (ii) Door Y (LH) & (RH).BI01010001010000000000000515BI010000126540Each
155155Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992 Fittings (iii) Door Bend T.S 110 mmBI01010001010000000000000515BI010000126632Each
156156Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992 Fittings (iv) Plain Tee 110 mmBI01010001010000000000000515BI010000126742Each
157157Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992 Fittings (v)Bend 45 DegreeBI01010001010000000000000515BI010000126833Each
158158Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992 Fittings (vi) Pipe Clip 110 mmBI01010001010000000000000515BI0100001269130Each
159159Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992 Fittings(A) (i) Single Socketed 3 Mtr. Length c) 160 mmBI01010001010000000000000515BI0100001270290metre
160160Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(i) Door Tee (160 mm)BI01010001010000000000000515BI010000127152Each
161161Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992 (ii) Door Bend T S.(160 MM)BI01010001010000000000000515BI010000127237Each
162162Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992 (iv) Plain TeeBI01010001010000000000000515BI010000127343Each
163163Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992 (v) Bend 87.5 DegreeBI01010001010000000000000515BI010000127440Each
164164Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992 (vi) Pipe Clip 160 mmBI01010001010000000000000515BI0100001275140Each
165165Labour for fitting and fixing U.P.V.C pipes for above ground work including cost of joining materials etc. fitting and fixing all necessary specials, cutting pipes,cutting holes in walls or R.C floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 mtr. and refilling the same complete as per direction of the Engineer - in - Charge.(payment will be made on centre line measurment of the total pipe line including specials)(ii) 110 mmBI01010001010000000000000515BI0100001276270Mtr.
166166Labour for fitting and fixing U.P.V.C pipes for above ground work including cost of joining materials etc. fitting and fixing all necessary specials, cutting pipes,cutting holes in walls or R.C floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 mtr. and refilling the same complete as per direction of the Engineer - in - Charge.(payment will be made on centre line measurment of the total pipe line including specials) (iii) 160 mmBI01010001010000000000000515BI0100001277180Mtr.
167167Labour for fitting and fixing U.P.V.C pipes for above ground work including cost of joining materials etc. fitting and fixing all necessary specials, cutting pipes,cutting holes in walls or R.C floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 mtr. and refilling the same complete as per direction of the Engineer - in - Charge.(payment will be made on centre line measurment of the total pipe line including specials) (ii) 110 mmBI01010001010000000000000515BI0100001278120Mtr.
168168Labour for fitting and fixing U.P.V.C pipes for above ground work including cost of joining materials etc. fitting and fixing all necessary specials, cutting pipes,cutting holes in walls or R.C floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 mtr. and refilling the same complete as per direction of the Engineer - in - Charge.(payment will be made on centre line measurment of the total pipe line including specials)(iii) 160 mmBI01010001010000000000000515BI0100001279150Mtr.
169169Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer (d) 1500 litre capacityBI01010001010000000000000515BI01000012807Each
170170Labour for hoisting plastic water storage tank. (ii) upto 1500 litre.BI01010001010000000000000515BI01000012817Each
171171Labour for punching hole in plastic water storage tank upto 50 mm diaBI01010001010000000000000515BI010000128221Each
172172Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling,15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials.BI01010001010000000000000515BI010000128316Each
173173Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. For 50 users\nBI01010001010000000000000515BI01000012842Each
174174Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials.With 250 mm thick dry brick work and 250 mm thick cement brick work (6:1) and 1.00m inside dia.BI01010001010000000000000515BI01000012852Each
175175Box cutting or filling in Road embankment in all sorts of soil including spreading the spoils properly over the flank as necessary or on berm to approximate grade\n& camber and rolling the sub-grade with power roller to proper camber and grade as per direction and satisfaction of Engineer-in-charge including uprooting and removing plants and jungles when and where necessary.BI01010001010000000000000515BI01000012861250sqm
176176Construction of granular sub-base by providing graded material, mixing in Wet Mix Plant at OMC, carriage of mixed material to work site, spreading in uniform layers with Motor grader on prepared surface in proper grade and camber, compacting with vibratory power roller to achieve the desired density, including lighting, guarding, barricading, including cost of all materials, machinery, tools and plants and cost of quality control complete as per Clause 401 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).\nGrading - VBI01010001010000000000000515BI0100001287312.5Cum
177177Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening / binding materials to fill up the interstices of coarse aggregate, watering including lighting, guarding, barricading and making necessary earthen bundh of one metre width on each side and preparing the bed by necessary cutting or filling, including cost of all materials and hire and labour charges of all men and machinery and compacting to the required density, as per Clause 404 of Specifications for Road & Bridge Works\nof MoRT&H (5th Revision).\nGrading-II Aggregate (53 mm to 22.4 mm) Using Stone Screening Type B (11.2 mm)\nmanual meansBI01010001010000000000000515BI0100001288281.25Cum
178178Providing and applying primer coat with Cationic Bitumen Emulsion of approved grade conforming to IS: 8887-1978 and requisite quantity on prepared surface of granular base including cleaning of road surface and spraying primer using Mechanical means including cost and carriage of bitumen emulsion and all other incidental costs of work complete as per Clause 502 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).\nFor WBM / WMM Surface: (with primer @ 0.70-1.0 kg/sqm)BI01010001010000000000000515BI01000012891250sqm
179179Providing, laying and rolling of Open - graded premix surfacing of 20 mm thickness composed of 13.2 mm (@ 0.018 m³ per m²) and 11.2 mm (@ 0.009 m³ per m²)\nsize stone aggregates, including thoroughly cleaning of the surface, screening, cleaning and pre-heating stone chips and fully pre-coating the same either\nusing viscosity grade paving bitumen or cut-back or emulsion, carrying the mixture by any suitable arrangements, laying the mixture uniformly over the surface, including line, grade and level to serve as wearing course on a previously prepared base, including mixing in Mobile Hot Mix Plant (Light Duty) and thoroughly rolling with a smooth wheeled roller 8-10 tonne capacity, finished to required level and\ngrades including the cost and carriage of stone chips and matrix, heating the matrix, preheating the aggregates to required temperature and including the hire charges of Mobile Hot Mix Plant (Light Duty) and other machinery, pay of operators, cost of fuel\nand lubricants etc. complete to be followed by seal coat of either Type A or Type B as per Technical Specification Clause 508 for Rural Roads of MORD.BI01010001010000000000000515BI01000012901250sqm
180180Providing and laying Premixed Seal Coat (Type B) with approved quality sand/grit @ 0.6 m3/ 100 m2 and bitumen binder on thoroughly cleaned black top surface coated with tack coat, including heating and mixing cleaned sand/grit (100 % passing through 2.36 mm sieve and retained on 180 micron sieve) uniformly with bitumen binder, laying and spreading the mix at an uniform rate using suitable means,\nbrushing the surface, if necessary, to ensure uniformity, followed by rolling with power roller including the cost and carriage of binder and aggregates, cost of heating the binder and aggregates and all other incidental charges, cost of\nfuel and lubricants, including hire charges of machineries, tools & plants required for construction and quality control complete as per Clause 511 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).\nBy Manual Means With Hot Bitumen Binder (@ 6.80 kg / 10 sqm.)BI01010001010000000000000515BI01000012911250sqm
181181Labour for boring through any type of soil for sinking tube well of required dia. With top enlargement by rig boring system (either by reverse circulation of by direct rotary method) including hire charges and labour for rig machine, tools, plants, staging, force pumping set and making arrangement for water required for boring, etc. complete and lowering of pipes, stainer, blind pipes etc. complete (where no lowering pipe is involved the corresponding rate would be reduced by 30%) For depth upto 250 mtr. 100 mm dis. Tube well with top enlargement of 200 mm dia. (upto 50 Mtr.) First 50 mtrs.BI01010001010000000000000515BI010000129250Mtr
182182Labour for boring through any type of soil for sinking tube well of required dia. With top enlargement by rig boring system (either by reverse circulation of by direct rotary method) including hire charges and labour for rig machine, tools, plants, staging, force pumping set and making arrangement for water required for boring, etc. complete and lowering of pipes, stainer, blind pipes etc. complete (where no lowering pipe is involved the corresponding rate would be reduced by 30%) For depth upto 250 mtr. 100 mm dis. Tube well with top enlargement of 200 mm dia. (upto 50 Mtr.) First 50 mtrs. Next 50 mtrs.BI01010001010000000000000515BI010000129350Mtr
183183Labour for boring through any type of soil for sinking tube well of required dia. With top enlargement by rig boring system (either by reverse circulation of by direct rotary method) including hire charges and labour for rig machine, tools, plants, staging, force pumping set and making arrangement for water required for boring, etc. complete and lowering of pipes, stainer, blind pipes etc. complete (where no lowering pipe is involved the corresponding rate would be reduced by 30%) For depth upto 250 mtr. 100 mm dis. Tube well with top enlargement of 200 mm dia. (upto 50 Mtr.) First 50 mtrs. Next 50 mtrs. Next 50 mtrs.BI01010001010000000000000515BI010000129450Mtr
184184Labour for boring through any type of soil for sinking tube well of required dia. With top enlargement by rig boring system (either by reverse circulation of by direct rotary method) including hire charges and labour for rig machine, tools, plants, staging, force pumping set and making arrangement for water required for boring, etc. complete and lowering of pipes, stainer, blind pipes etc. complete (where no lowering pipe is involved the corresponding rate would be reduced by 30%) For depth upto 250 mtr. 100 mm dis. Tube well with top enlargement of 200 mm dia. (upto 50 Mtr.) First 50 mtrs. Next 50 mtrs. Next 100 mtr.BI01010001010000000000000515BI010000129510Mtr
185185Supplying at site and fitting, fixing of the following accessories corresponding to the dia. Of the blank/housung pipes as specified in details below including two coats of bituminious paint in all sides.PVC end cap conforming to IS : 12818 - 2010 and \"V\" square threaded for sealing the bottom of well assembly)\n 100 mm dia.BI01010001010000000000000515BI01000012961Each
186186Supplying at site and fitting, fixing of the following accessories corresponding to the dia. Of the blank/housung pipes as specified in details below including two coats of bituminious paint in all sides. PVC Reducing socket\n150 mm X 100 mm.BI01010001010000000000000515BI01000012971Each
187187Supplying at site and fitting, fixing G.I Top cap \n200mm dia.BI01010001010000000000000515BI01000012981Each
188188Supplying at site and fitting, fixing 300mm M.S. Housing clamp of approved qualityBI01010001010000000000000515BI01000012991per set
189189Centre guide of approved quality\n200 mm dia. (with clamp)BI01010001010000000000000515BI01000013008per set
190190Labour for making arrangement for showing verticality test including the cost for hire charge tools and plants, scaffolding, labour etc all completeBI01010001010000000000000515BI01000013011L.S.
191191Collecting sample of water for bacteriological and chemical test from any depth at any time during execution of work including hire and labour charges for tools and plants and sterilising the equipments, paying all charges and fees, testing etc. complete in all respect as per direction.BI01010001010000000000000515BI01000013021L.S.
192192Packing the annular space between the outside of the tube well pipes & strainers and the bore with pea size washed gravel of approved qualityhaving size from 2 mm to 5 mm or the size approved by the Engineer-incharge including cost of all materials labour and equipment complete.\nNote: Initial 6 m. of Annular space between the housing pipe and the bore should not be shrouded with Pea size gravel to avoid contamination with surface water\nBI01010001010000000000000515BI010000130310Cum
193193Packing annular space between the outside of the housing pipe and the bore with puddled clay balls of approved size as per direction of the Engineer-in-charge with cost of all materials and labour complete.BI01010001010000000000000515BI01000013044Cum
194194Geophysical investigation of the acquifer by electrologging system with all tools and plants as necessary including supply of necessary report.BI01010001010000000000000515BI01000013051Each Item
195195Washing and developing tube well with air compressor pump and engine for 8 (eight) hours continuous pumping per day with necessary arrangements for testing the yield in gallons per hour with 'V' notch including hire and labour charges for all tools and plants and scaffolding as required.BI01010001010000000000000515BI01000013063Days
196196Supply of PVC pipes & fittings (medium duty) conforming to ASTMD -1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). 100 mm diaBI01010001010000000000000515BI010000130779Mtr
197197Supply of PVC pipes & fittings (medium duty) conforming to ASTMD -1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). 150 mm diaBI01010001010000000000000515BI010000130851Mtr
198198Supplying, fibre glass reinforced Epoxy resin slotted strainer of 1 mm slot width in 6.1m length of approved make and as per direction of the Engineer - in - Charge. 150 mm nominal dia 6.0 mm wall thicknessBI01010001010000000000000515BI010000130930Mtr
199199Supplying M.S. male/ female adopter of approved make and brand for coupling of M.S. pipe and fibre glass strainers, as per direction of the Engineer - in - Charge.\n10 mm dia.BI01010001010000000000000515BI01000013104Mtr
200200Supplying of G.I. Pipe ( Make TATA-M) pipe having heavy duty G.I. Socket/elbow(TATA) incl cutting & threading as required a) 50 mm.dia \nLight QualityBI01010001010000000000000515BI010000131130Mtr
201201Supplying of G.I. Pipe ( Make TATA-M) pipe having heavy duty G.I. Socket/elbow(TATA) incl cutting & threading as required a) 25 mm dia \nLight QualityBI01010001010000000000000515BI010000131215Mtr
202202Supply & fixing 50 mm dia Gun metal Non-Return valve(Wheel valve) tested 21 kg per sq cmBI01010001010000000000000515BI01000013131Each
203203Supply & fixing 50 mm dia Gun Metal Peets Valve(ISI)(Tested 21 kg per cm)BI01010001010000000000000515BI01000013145Each
204204Supply & fixing 50 mm dia G.I. FlangeBI01010001010000000000000515BI01000013152pair
205205Supply & fixing holding clamp fabricated by 50mm x 6mm with necy. Nuts, bolts & washers for holding the the column pipe.\nBI01010001010000000000000515BI01000013162pair
206206Labour charge for Testing & Lowering the submersible Pump motor set with submersible cable along with the column pipes into the tube well after socketing the column pipes step by step including arrangement of tripod, chain pully & tools & Tackles & providing suitable manpower to satisfactory operation.\nBI01010001010000000000000515BI01000013171L.S.
207207ELECTRICAL (Schedule Items) :\nSupply & Fixing 415V 125A TPN switch (L&T) in suitable SS enclosure with HRC fuses on LS & NL on angle iron frame on wall incl. earthing attachment.\n\nBI01010001010000000000000515BI01000013181set
208208Supply & Fixing 415V 125A four pole on load Change over switch (L&T/Havells) in suitable SS enclosure on angle iron frame on wall incl. earthing attachment.\n\nBI01010001010000000000000515BI01000013191set
209209Supply & fixing sheet metal (16SWG, 500x150mm) Iron Clad 415V, 315A 4 bars Busbar Chambers on angle iron frame on wall, incl. earthing attachment and painting as required.BI01010001010000000000000515BI01000013201set
210210Supply & fixing 415 volt 63A TPN switch in S.S. enclosure with HRC fuses on LS & NL to be fixed on angle frame on wall including earthing attachment.(L&T/Seimens)BI01010001010000000000000515BI01000013211set
211211Supply & fixing 240 volt 32A DP switch in S.S. enclosure with fuses on LS & NL to be fixed on angle frame on wall including earthing attachment.(Havells/Standard)BI01010001010000000000000515BI01000013221set
212212Supply & fixing double door type 6 way Vertical TPN MCB DB (Legrand) with IP 42/43 protection SS enclosure recessed in wall & mending good the damages to original finish incl. interconnection with suitable size of copper wire, neutral link & earthing attachment comprising of the following accessories \na) 125A Four pole thermal magnetic MCCB- 1 no\nb) 63A TP MCB ---4 nos\nc) 32A TP MCB --- 2 nosBI01010001010000000000000515BI01000013231set
213213Supply & fixing 4 way double door Horizontal TPN MCB DB with SS enclosure (Legrand/Seimens/ABB) concealed in wall after cutting the wall & mending good the damages to original finish with earthing attachment comprising with the following. a) 63 A Four Pole isolator -1 No. b)16 to 32 A range SP MCB.-6 Nos.\nc) Blank plate -6 nosBI01010001010000000000000515BI01000013242set
214214Supply & Fixing (2+12) way SPN MCBDB (Legrand) with IP-42/43 protection Concealed in wall & mending good the damages to original finish incl. Interconnection with suitable copper wire & nuetral link incl. earthing attachment comprising with the following (All Legrand):\na) 63A DP MCB isolator & necy. connection --- 1 no\nb) 6 to 16A SP MCB as required breaking capacity \n 10KA & C characteristic ---- 12 nosBI01010001010000000000000515BI01000013254set
215215Supply & fixing SPN MCB DB (2+8) WAY (Make legrand/ Seimens/ ABB) with S.S. Enclosure concealed in wall after cutting wall & mending good the damages & earthing attachment comprising with the following: \na) 40 A DP isolator - 1 No. b) 6 to 16 A range SPMCB - 8 Nos.BI01010001010000000000000515BI01000013266set
216216Supplying & Fixing MS fan clamp of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and paintingBI01010001010000000000000515BI010000132730each
217217Supplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S&F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concre from entering the box.BI01010001010000000000000515BI010000132875each
218218Supply & Fixing electronics step type & Moduler Socket type (2 module), Fan regulator (Legrand/Nort-West)BI01010001010000000000000515BI010000132975each
219219Laying of the following XLPE Al armoured cable incl. 2 x 10 SWG G.I. Earth continuity conductor recessed in wall & mending good the damages to original finish:- a) 3.5 x 35 sq mmBI01010001010000000000000515BI010000133010mtr
220220Laying of the following Al armoured cable through under ground trench 460mm wide x 760mm average depth with necy brick protechtion 8 nos brick per metre, incl filling up the excaveted trench with shifted soil, levelling up & restoring the surface duly rammed a) 3.5 x 35 sq mmBI01010001010000000000000515BI010000133175mtr
221221Laying of the following Al armoured cable through under ground trench 460mm wide x 760mm average depth with necy brick protechtion 8 nos brick per metre, incl filling up the excaveted trench with shifted soil, levelling up & restoring the surface duly rammed b) 4 X 16 sqmm. XLPE /A Cable.BI01010001010000000000000515BI010000133280mtr
222222Laying of the following Al armoured cable through under ground trench 460mm wide x 760mm average depth with necy brick protechtion 8 nos brick per metre, incl filling up the excaveted trench with shifted soil, levelling up & restoring the surface duly rammed c) 2 X 6 sqmm. XLPE /A Cable.BI01010001010000000000000515BI0100001333145mtr
223223Supply & laying medium gauge G.I.Pipe(ISI-Medium) for cable protection a) 50 mm diaBI01010001010000000000000515BI01000013343mtr
224224Supply & laying medium gauge G.I.Pipe(ISI-Medium) for cable protection b) 40 mm diaBI01010001010000000000000515BI01000013356mtr
225225Supply & fixing compression type gland with brass gland brass ring incl. socketing the ends off by crimping method incl. S/F solderless socket (Dowels make) & jointing ,materials etc. Of the following XLPE/A cable a) 3.5 x 35 sq mmBI01010001010000000000000515BI01000013366set
226226Supply & fixing compression type gland with brass gland brass ring incl. socketing the ends off by crimping method incl. S/F solderless socket (Dowels make) & jointing ,materials etc. Of the following XLPE/A cable a) 4 X 16 sqmm. XLPE /A Cable.BI01010001010000000000000515BI01000013372set
227227Supply & fixing compression type gland with brass gland brass ring incl. socketing the ends off by crimping method incl. S/F solderless socket (Dowels make) & jointing ,materials etc. Of the following XLPE/A cable b) 2 X 6 sqmm. XLPE /A Cable.BI01010001010000000000000515BI01000013382set
228228Supply & drawing of 1.1 Kv grade single core stranded 'FR' Pvc insulated & unsheathed copper wire (Finolex/Havells/Polycab/ Mescab/KEI) of the following sizes through 19mm Polythene pipe recessed in wall. a)2 x 4 + 1 x 2.5 sq mm through 19mm Alka.Pipe (SPNDB), (AC)BI01010001010000000000000515BI0100001339250mtr
229229Supply & drawing of 1.1 Kv grade single core stranded 'FR' Pvc insulated & unsheathed copper wire (Finolex/Havells/Polycab/ Mescab/KEI) of the following sizes through 19mm Polythene pipe recessed in wall. b) 2 x 2.5 + 1 x 1.5 sq mm through 19mm Alka.pipe (P/P & Com)BI01010001010000000000000515BI0100001340585mtr
230230Supply & drawing of 1.1 Kv grade single core stranded 'FR' Pvc insulated & unsheathed copper wire (Finolex/Havells/Polycab/ Mescab/KEI) of the following sizes through 19mm Polythene pipe recessed in wall. d) 3x1.5 sq mm through 19mm Alkathene pipe(Out door Light)BI01010001010000000000000515BI0100001341425mtr
231231Distn. wiring in 3 x 1.5 sqmm single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Gloster/Finolex/Havells) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/ call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish a) Average run 8 mtrBI01010001010000000000000515BI0100001342142Pts
232232Distn. wiring in 3 x 1.5 sqmm single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Gloster/Finolex/Havells) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/ call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish b) Average run 7 mtrBI01010001010000000000000515BI010000134382Pts
233233Supply & drawing of 1.1 Kv grade single core stranded 'FR' Pvc insulated & unsheathed copper wire (Finolex/Havells/Polycab/ Mescab/KEI) of the following sizes through Polythene pipe recessed in wall. c) Average run 6 mtrBI01010001010000000000000515BI010000134450Pts
234234Distribution wiring in 1.1 KV grade 3 x 1.5 sq mm single core stranded 'FR' PVC insulated & unsheathed copper wire (brand approved by EIC) in 19mm bore, 3mm thickpolythene pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240V 6A 3 pin modular type plug socket & modular type switch(Brand appr. by EIC) incl. S&F earth continuity wire fixed on 4 module GI switch board with 3/4 module top cover plate flushed in wall incl mending good damage to original finish. (on board)BI01010001010000000000000515BI010000134574pts
235235Supply & fixing of Modular type computer plug board of 12 module GI box with cover plate recessed in wall comprising of the following(Legrand/Crabtree/North West/Philips):\na) 6/16A socket ---1 no\nb) 6A socket - 2 nos \nc) 16A switch -- 2 nosBI01010001010000000000000515BI010000134634set
236236Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Legrand/Crabtree/North West/Philips) with 16A Modular type\nswitch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.BI01010001010000000000000515BI010000134717set
237237Supply & fixing of Modular type 16A control switch of 2 module GI box with cover plate recessed in wall comprising of the following (Legrand/Crabtree/North West/Philips):\na) 16A switch ---1 set \nBI01010001010000000000000515BI01000013484each
238238Fixing only the tube light fitting suspended 25 cm below the ceiling with 2 nos 20mm dia E I conduit(14 SWG) support fixed with \"L\" type MS clamp fixed on ceiling with fastener & connecting the length with PVC insulated copper wire 1.10 mtr length.BI01010001010000000000000515BI010000134980each
239239Fixing the above Tube light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener.BI01010001010000000000000515BI010000135025each
240240Supply & fixing 40mm dia GI (ISI-M) pipe of length 1.20 \nMtr long KMDA type Arm bracket thouroughly welded \nwith 100mm dia 30 cm long vertical jacket with necy. tie \nsupport incl. S/F pole cap & painting as derection of the EIC.BI01010001010000000000000515BI010000135116set
241241Earthing the the Installation by 50 mm dia G.I. Pipe (ISI -M) 3.04 mtr long & 1x4 SWG G.I.(Hot dip) wire (4 mtr long) with suitable nuts, bolts & washer etc. Incl S/F 15 mm dia GI protection pipe (1 mtr long) to be filled with bitumen partly under ground level & partly under ground level driven to an depth of 3.65 mtr below the ground level.BI01010001010000000000000515BI01000013529set
242242Supply & fixing earth busbar of galvanised (Hot dip) MS flat 25mm x 6mm on wall having clearance of 6mm from wall Incl providing drilled holes on the busbar complete with nuts, bolts & washers spacing insulator etc. as requiredBI01010001010000000000000515BI01000013532mter
243243ELECTRICAL (Non Schedule Items) :\nSupply & delevery of 1.1 Kv grade XLPE Aluminium armoured cable(make Gloster/Polycab/Havells/Cystal) \na) 3.5 x 35 sq mmBI01010001010000000000000515BI010000135485mtr
244244Supply & delevery of 1.1 Kv grade XLPE Aluminium armoured cable(make Gloster/Polycab/Havells/Cystal) b) 4 X 16 sqmm. XLPE /A Cable.BI01010001010000000000000515BI010000135580mtr
245245Supply & delevery of 1.1 Kv grade XLPE Aluminium armoured cable(make Gloster/Polycab/Havells/Cystal) c) 2 X 6 sqmm. XLPE /A Cable.BI01010001010000000000000515BI0100001356145mtr
246246Supply & Fixing multitune call bell on suitable board on wallBI01010001010000000000000515BI01000013573set
247247Supply & fixing of 1200mm sweep Ceiling Fan (White) complete with all acessaries without regulater (Make Orient, New bridge) Incl S/F necy copper flex wire.BI01010001010000000000000515BI010000135875set
248248Supply of recessed/Surface type 15w LED fitting suitable for false ceiling/Surface (Make Philips/ Crompton, cat no - LSCSM-15W- CDL/NW/WW)BI01010001010000000000000515BI010000135924set
249249Fixing charge of the recessed type LED light after cutting false ceiling board neatly and making connection.BI01010001010000000000000515BI010000136024set
250250Supply and delivery of 4' single LED type tube light fitting complete with all acessaries directly on ceiling with HW round block & suitable size of MS fastener (make Crompton /Havells/ Philips cat no - IGP 131LT8-16, LTT8-20, MAS B269LED Tube 1200mm 18W865 T8 I as Lapproved by EICBI01010001010000000000000515BI010000136170set
251251Supply and delivery of 4' Twin LED type tube light fitting complete with all acessaries directly on ceiling with HW round block & suitable size of MS fastener (make Crompton /Havells/ Philips cat no - TMC 501 P 2xT - LED 22W P3242, MAS LED Tube 1200mm 18W865 T8 I as approved by EIC)BI01010001010000000000000515BI010000136215set
252252Supply 2' 8w LED tube light (Make Crompton cat - LTT8-8) complete with Mirolta decorative box type fitting (Make Crompton, cat no - DMLNLT8 - 8)BI01010001010000000000000515BI010000136320set
253253Supply & fixing of LED Bulk Head light fitting (Crompton, cat no - LBHE-10-CDL)BI01010001010000000000000515BI01000013644set
254254Supply & delivery 0.5W LED night Lamp (SSK-PAG-0.5W) for batten light points.BI01010001010000000000000515BI010000136516each
255255Supply and delivery of 9 W LED Bulb (Make PHILIPS Steller Bright High Wattage)BI01010001010000000000000515BI010000136613each
256256Supply & fixing only of the following Exhaust Fan (Metal Body) (Make Orient/Crompton/EPC)with louvre shutter after cutting wall & mening good the damages. a) 230 mm (9\") sweep exhaust fan (Make EPC, Heavy duty)BI01010001010000000000000515BI01000013678set
257257Supply & fixing only of the following Exhaust Fan (Metal Body) (Make Orient/Crompton/EPC)with louvre shutter after cutting wall & mening good the damages. b) 300 mm (12\") sweep exhaust fan (Make EPC)BI01010001010000000000000515BI01000013689set
258258Supply & fixing of 72W LED Street light fitting (Make Crompton, cat no - LSTP-72-CDL)BI01010001010000000000000515BI01000013696set
259259Supply & fixing of 45W LED street light fitting (Make Crompton, cat no - LSTP-45-CDL)BI01010001010000000000000515BI01000013706set
260260Supply & fixing of 30W LED Street light fitting (Make Crompton, cat no - LSTS-30-CDL)BI01010001010000000000000515BI01000013714set
261261Supply and delivery of 1.5 TON Air Conditioner ( Make - O GENERAL / MITSUBISHI Cat no. TURBO JET FLOW SRK18CS-S6 ( 1 star)BI01010001010000000000000515BI01000013724set
262262Supply & fixing drawing copper pipe, Power cable, Drainage pipe with necessary insulation etc. completeBI01010001010000000000000515BI010000137340Mtr
263263Supply of 415V 3-Phase 3 Hp 2.2 Kw) submersible Pump Motor set suitable fot 150 mm borewell - radial flow having overall head of (43 mtr to 18 mtr) & discharge capacity of (380 LPM to 135 LPM), 4 Stages. The discharge outlet size will be 50mm (2\"inch) \n(Make KSB Cat No. 150WT4J3\nBI01010001010000000000000515BI01000013741set
264264Supply & Laying 3 core 2.5 sqmm flat submersible cable (Finolex/ Mescab/KEI )\n\nBI01010001010000000000000515BI010000137580set
265265Supply & Laying OF 50 mm G.I.Pipe .BI01010001010000000000000515BI010000137630mtr
266266Supply & fixing of 415V 32A TPN SFU with sheet steel enclosure on flat iron frame on wall incl. S/F HRC fuses on LS & NL (Make L&T/Siemens)BI01010001010000000000000515BI01000013771set
267267Supply & Fixing of control panel suitable for 3-Phase 3 HP Submersible Pump motor set comprising of DOL starter, dual Ammeter & Voltmeter, indicator lamp to be fixed on wall incl making connection & necy. earthing attachment. (Make L&T M-G6 DOL Starter Cat No. SS97756)BI01010001010000000000000515BI01000013781set
268268Supply & installation of G.I. pipe (Make TATA-M) pipe having heavy duty G.I. socket/elbow (TATA) incl cutting & threading as required \na) 40mm dia (For Vertical column pipe & upto Header Assembly) \nBI01010001010000000000000515BI010000137950set
269269Supply & fixing 50 mm dia Gun metal Non-Return/Horizontal Check valve (ISI) \nBI01010001010000000000000515BI01000013801set
270270Supply & fixing 50mm dia G.I.Peets Valve(ISI)(Tested 21 kg per cm)\nBI01010001010000000000000515BI01000013813set
271271Supply & fixing 100 mm x 65 mm dia G.I. Reducing Tee (For header)BI01010001010000000000000515BI01000013824set
272272Supply & fixing 100mm dia G.I. nipple short piece 150mm longBI01010001010000000000000515BI01000013835set
273273Supply & fixing 100mm dia G.I. plugBI01010001010000000000000515BI01000013842set
274274Supply & fixing 65 mm x 50 mm dia G.I. Reducing socket (For delivery Line from header)BI01010001010000000000000515BI01000013853set
275275Supply & fixing 50 mm dia G.I. Union\nBI01010001010000000000000515BI01000013864set
276276Making holes on wall & mending good the damages to original finishBI01010001010000000000000515BI01000013874set
277277Labour charge for Testing & Lowering the submersible Pump motor set with submersible cable & delivery pipe line into the U. G Resovoir including arrangement of tools & Tackles etc. to satisfactory operation.\nBI01010001010000000000000515BI01000013881set
278278Supply & delivery of 415V (3-Ph) 20 KVA Silent Deisel Generator Set complete with all accessaries (Make JACKSON)BI01010001010000000000000515BI01000013891set
279279Installation, testing & commissioning of the above D.G. set incl. making flatform for installation of above D.G.Set with Supply of full tank Diesel oil & required Mobil oil to satisfactory operationBI01010001010000000000000515BI01000013901item

AI Tender Summary

OUR REF NO 22973877
AUTHORITY Government Departments
TENDER VALUE 6.83 Crore
LAST DATE 14-01-2020
Authority
Authority Name West Bengal State Police Housing Corporation Limited
Work Description Construction Of Model Urban P . S . With Force Barrack And Canteen With Boundary Wall , Gate With Security Post , Internal Road And External Electrification At Naihati Under Barrackpore Police Commissionerate . ( 1St Call )
Basic Detail
Tender No WBPHIDCL/ACE/NIT- 166(e)/2019-2020
Bidding Type Tender
Location
City Naihati
State West Bengal
Key Dates
Publish Date 20 Dec 2019
Submission Date 14 Jan 2020
Open Date 16 Jan 2020
Finance
Tender Value 6.83 Crore
Tender Fee Ref. Documents
EMD 13.66 Lakhs
Exemption Not Available
Document List
Tendernotice_1.pdf
BOQ_477317.xls
0DA41389-2E78-437F-9C31-1BA7AB0E9737.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Dec 20, 2019
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 14, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 16, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

xls

BOQ_477317.xls

html

0DA41389-2E78-437F-9C31-1BA7AB0E9737.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders