Electrical Street Light And Cable Laying Work At Lgbrimh Tezpur Electrical Street Light Earlier Opd To Main Hospital And Auditorium To Canteen In The Lgbrimh Campus , Tezpur
Tender Value
49.33 Lakhs
Estimated cost
Bid Submission
30 Dec 2019
0 days left
EMD
1 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
LGBRIMH Tezpur → Assam
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Electrical Street Light And Cable Laying Work At Lgbrimh Tezpur Electrical Street Light Earlier Opd To Main Hospital And Auditorium To Canteen In The Lgbrimh Campus , Tezpur
BOQ
| Name of Work: Electrical Street Light earlier OPD to Main hospital and auditorium to canteen in the LGBRIMH Campus,Tezpur. | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Electrical Works | |||
| 2 | 1.01 | Pole type BOP or equivalent-9030 Height 9 m. The materials of the pole as follows: conforming to grade S355JO, base plate:- Fe 410 conforming to IS 226/IS 2062, Foundation Bolts:-6.8 Gr. As per IS 1367, pole section:-the octagonal poles shall be in single piece with single longitual welding join, galvanization:: The poles shall be hot dip galvanized as per IS 2629/IS2633/IS 4759 standards with average coating thickness of 65 micron. the galvanizing shall be done in single dipping. door opening :- the octagonal poles shall have door of approximate 500 mm length at the elevation of 500 mm from the base plate . the door shall be vandal resistance and shall be weatherproof to ensure safety of inside connection as approved by the deptts. the door shall be flush with the exterior surface and shall have suitable locking arrangement. the pole shall be adequately strengthened at the location of the door compensate for the loss in section. there shall also be suitable arrangement for the purpose of earthing, smart pack junction box wit 32 A DP MCB & terminals for mounting inside base compartment of pole Top dia : -70, botton dia 155, sheet thick ness -3 mm, base plate dimensions in mm (L x B x T ) 260 x 260 x 16 ,Foundation Bolt Size:-(no. x dia.)4 x 24 dia , pitch circle dia :- (PC 250 ), Bolt Lenght :- 750 , Projected Bolt Lenght :- 125 Anchor plate thickness :-4 mm, pole Foundation :- The octagonal poles shall be bolted on a pre- cast foundation with a set of four foundation bolts for greater rigidity foundation :- the doundation shall be done with (Earth work 2.04 cubic Meters. RCC 1: 1.5:3 Proporation 0.65 cubic meters steel 22.43 Kg. Shuttering 4.32 squre metres. | item1 | 36 | Each |
| 3 | 1.02 | Supplying including fitting and fixing of Hot Dip galvanised arm bracket for installation of luminaries. Header with top cap 300 mm long pipe of thickness 3 with arrangement to fix on pole top with 3 nos of bolts. I . Armed of required length size 48.3 mm out side dia x 3.25 mm thick (Bajaj /philips/valmont/ paruthi engr/ nezone make) stiffener plate from arm of the following types: \n(A)Single arm bracket 1500 mm long for 3 m to 10metre poles. | item2 | 33 | Each |
| 4 | 1.03 | (B). Double arm bracket 1000 mm long for 3 m to 10 metre poles. | item3 | 12 | Each |
| 5 | 1.04 | Supplying, Fabrication ,Erection, Testing commissioing of vermin and dust proof (IP-43 protection ) totally enclosed cubical type compartmental floor mounting panel board of size 1450 mm x 100 0mm x 500 mm made of 16 SWG ( mm ) C.R. Sheet and 300 mm x 30 mm x 5 mm MS Angle having 4 nos legs at the bottom and C.R sheet roofing on the top complete painting with 2 coats of Red Oxide metal primer and 2 coats of Enamel paint. The panel board is to be erected in 1 : 3: ^PCC foundation including excavation complete neatly wiring done, with the provision for the following electrical accessories .Incomer 125 A , 4 Pole 25 KA AC 415 V MCCB with D.P Handle Outgoing TPN 5 Nos, 33 nos DP Outgoing. 0-125 A (digital ) Ammeter. 0-500 V (Digital) Voltmeter. Ammeter selector Switch-1. Voltmeter selector Switch-1, Indicator Lamp (R,Y,B)-03, 2 A slide lock fuse-03,125 /5 CT coils-3, control wiring along with required size of copper busbar including All MCCB/ MCB Incoming and Outgoing complete as requied. | item4 | 1 | Each |
| 6 | 1.05 | Supply and laying of following size PVC/ XLPE insulated and PVC sheathed 1.1 KV Grade solid Aluminium cnductor up to 10 sq mm balance stranded conductor , XLPE Insulated, cores laid up , PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Alumium strip, Galvanised for cables up to 2 x 10 sq mm . 3 x 10 sq mm , 4 x 6 sq mm balance all galvanised steel strip ) extruded PVC Type 5T2 shearhed 650 /1100 V grade as per IS 7908 (part1) 1988 armoured U.G cable . U.G cable laid in ground/ partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm. refilling protective brick covering , sand cushioning etc complete handling of surplus spoil, debris etc to proper place as specified and directed by the dept.Nicco/ Havells/Polycab/RPG/Finolex/Gloster/ 25.00 Sq.mm 4 Core armoured U.G. cable | item5 | 945 | Metre |
| 7 | 1.06 | Supply and laying of following size PVC/ XLPE insulated and PVC sheathed 1.1 KV Grade solid Aluminium cnductor up to 10 sq mm balance stranded conductor , XLPE Insulated, cores laid up , PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Alumium strip, Galvanised for cables up to 2 x 10 sq mm . 3 x 10 sq mm , 4 x 6 sq mm balance all galvanised steel strip ) extruded PVC Type 5T2 shearhed 650 /1100 V grade as per IS 7908 (part1) 1988 armoured U.G cable . U.G cable laid in ground/ partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm. refilling protective brick covering , sand cushioning etc complete handling of surplus spoil, debris etc to proper place as specified and directed by the dept.Nicco/ Havells/Polycab/RPG/Finolex/Gloster\n 240 Sq.mm 4 Core armoured U.G. cable | item6 | 400 | Metre |
| 8 | 1.07 | Wiring for drawing sub main line with p.v.c insulated single core unsheathed industrial (multistrand) cable FR conforming to IS-694:1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts in surface flat ISImarked casing n capping system including earth continuity.(Finolex /RR Kabel/Polycab/ Havells)\n(a) with 2 x 4 sq.mm + earth continuity with 1 x 2.5 sq.mm in flat 19 mm ISI marked casing n capping system. | item7 | 290 | Metre |
| 9 | 1.08 | Supplying and fitting of 90 watt LED Street Light LSTN-90- CDL-A Set complete with screws nuts etc complete as required. (Crompton Greaves. /Philips/Havells/ Bajaj) | item8 | 35 | Set |
AI Tender Summary
Tender Timeline
Dec 20, 2019
11:30 IST
Tender Published
Tender notice published.
CompletedDec 30, 2019
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedDec 31, 2019
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender