Repair/Maintenance To Street Security Light , Summer Cooling Appliances And External Electric Supply Systems , E/M Installations And Other Connected Works At Mil Stn Nowgong Under Ge Jhansi, NOWGONG-Madhya Pradesh

Military Engineer Services-MES has published Repair/Maintenance To Street Security Light , Summer Cooling Appliances And External Electric Supply Systems , E/M Installations And Other Connected Works At Mil Stn Nowgong Under Ge Jhansi. Submission Date for this Tender is 07-01-2020. Electrification Work Tenders in NOWGONG Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

22918164
Repair/Maintenance To Street Security Light , Summer Cooling Appliances And External Electric Supply Systems , E/M Installations And Other Connected Works At Mil Stn Nowgong Under Ge Jhansi
Open Tender
Indian
Madhya Pradesh
NOWGONG
07-01-2020

Tender Details

Repair / Maintenance To Street Security Light , Summer Cooling Appliances And External Electric Supply Systems , E / M Installations And Other Connected Works At Mil Stn Nowgong Under Ge Jhansi

Key Value

Document Fees
INR 500 /-
EMD
INR 65780.0 /-
Tender Value
INR 32.89 Lakhs /-

BOQ Items

Name of Work : REPAIR MAINT TO STREET SECURITY LIGHT, SUMMER COOLING APPLIANCES AND EXTERNAL ELECTRIC SUPPLY SYSTEMS, E&M INSTALLATIONS & OTHER CONNECTED WORKS AT MIL STN NOWGONG UNDER AGE E&M AT GE JHANSI
Sl. No. Item Description Item Code / Make Quantity Units
1 1 M&L in replacement of Power Cables, Aluminum Stranded Conductor, XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured Galvanized Wire or Galvanized Steel Strip, PVC Sheathed, 1100V grade as per IS:7098(Part 1) 1988 complete laid in trenches / floors / fixed to poles/walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting as per site requirement and testing on completion for the following size of cables:- Note: Excavation, earth work and cable protection pipe shall be measured and paid separately under relevant items.
2 1.01 25 Sqmm, 4 Core 100 RM
3 1.02 16 Sqmm, 2 Core 300 RM
4 2 Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth and getting in any type soil for laying of cables/ pipes etc complete all as specified and directed by Engineer-in-Charge. 80 Cum
5 3 Returning, filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed by Engineer-in-Charge. 65 Cum
6 4 Removing surplus excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge. 15 Cum
7 5 M&L for cutting of existing road / hard standing up to 15 cm depth for laying of pipe lines and making good the disturbed surfaces by providing PCC 1:2:4 after laying of pipes lines and returning filling of soil, complete all as specified and directed.\nNote:- Excavation and earth work below road / hard standing will be measured and paid under relevant items. 10 Sqm
8 6 Supply and laying of High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 of size 50mm dia laid in trenches for cable protection. 690 RM
9 7 Supply and laying of High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 of size 40mm dia laid in trenches for cable protection. 270 RM
10 8 Supply and connect in replacement of PVC insulated and PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volts grade, conforming to IS 694, twin core, 1.5 sqmm for connecting from junction box to street light fitting complete all as specified and directed by Engineer-in-Charge. 200 RM
11 9 Supplying and fixing 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4mm dia GI suspension wire, one twin core cable flat or circular of size 10 sqmm complete all as specified and directed by Engineer-in-Charge. 200 RM
12 10 Supply and fix in replacement of GI pipe bracket made out of 40mm dia medium grade GI pipe of 1.50mtr long bent to required shape and fixed to steel tubular / PCC pole with clamps(02 Nos) made out of 40mm x 5 mm MS flat fixed with suitable nuts, bolts and washers etc complete all as specified and directed by Engineer-in-Charge. 20 Each
13 11 Supply and fix SMC(Sheet Moulded Compound) outdoor type junction box of size 200mm x 140mm x 95mm (Outside Dimensions) with 63Amps rated four pole connector, one single pole MCB of 6 Amps rating mounted on DIN rail, stainless steel cable glands of suitable size for incoming and outgoing cables including fixing on steel tubular poles / PCC poles with 25mm x 4mm MS clamps (02 Nos), nuts & bolts etc including taking down existing u/s junction box of any type and size complete all as specified and as directed. 30 Each
14 12 Supply and fix in replacement of LED street light fitting 35 Watt with pressure die-cast housing along with polycarbonate diffuser and LEDs with secondary optics and IP 65 protection including taking down existing unserviceable street light fitting of any description complete all as specified and directed by Engineer-in-Charge. 25 Each
15 13 Supply and fix in replacement of LED street light fitting 70 Watt with pressure die-cast housing along with polycarbonate diffuser and LEDs with secondary optics and IP 65 protection including taking down existing unserviceable street light fitting of any description complete all as specified and directed by Engineer-in-Charge. 15 Each
16 14 Supply and fix in replacement of LED street light fitting 90 Watt with pressure die-cast housing along with polycarbonate diffuser and LEDs with secondary optics and IP 65 protection including taking down existing unserviceable street light fitting of any description complete all as specified and directed by Engineer-in-Charge. 15 Each
17 15 Supply and fix in replacement of LED street light fitting 120 Watt with pressure die-cast housing along with polycarbonate diffuser and LEDs with secondary optics and IP 65 protection including taking down existing unserviceable street light fitting of any description complete all as specified and directed by Engineer-in-Charge. 10 Each
18 16 Supply and fix in replacement of LED flood light fitting 100 Watts in Aluminium die-cast housing and toughened glass with silicon gasket for IP66 protection including taking down existing unserviceable flood light fitting of any description complete all as specified and directed by Engineer-in-Charge. 5 Each
19 17 Supply and fix in replacement of LED flood light fitting 150 Watts in Aluminium die-cast housing and toughened glass with silicon gasket for IP66 protection including taking down existing unserviceable flood light fitting of any description complete all as specified and directed by Engineer-in-Charge. 5 Each
20 18 Supply and fix in replacement of Post top lantern Black ABS plastic spigot, spun aluminium canopy, with clear acrylic diffuser and accessories along with LED lamp 14 Watt with B22 base lamp holder including taking down existing unserviceable post top lantern fitting of any description complete all as specified and directed by Engineer-in-Charge. 10 Each
21 19 Supply only LED tube rod 20 watt, retrofit type, 4 feet with PC body, full white. 500 Each
22 20 M&L for preparation of old painted surfaces of LT 9.0m long poles and painting with aluminium paint on all steel surfaces such as poles, channels, angles, clamps, nuts, bolts and washers of any description including zebra marking with black paint upto 1.50 m height from coping of pole, radium reflector band / strips of 5cm wide Green (02 Nos) & White (01 No) shall be provided at a height of 1.50mtr from coping of pole and numbering of pole shall be done in white colour on black background at suitable place on the pole complete as directed by Engineer-in-Charge. 50 Each
23 21 Supply and erection of Hot dip galvanized tapered octagonal pole of height 8.0 mtrs in single or double section having top dia 70mm and bottom dia 130mm made up of 3mm thick sheet and welded with a base plate of size 200mm x 200mm x 16mm thick and provided with 1000mm long single arm bracket with 15 degree of angle for mounting street light fitting complete with provision of 04 Nos of ‘J’ type foundation bolts of size not less than 20mm dia, 600mm long embedded in PCC foundation concrete as per manufacturer’s recommendation including necessary earth work, RFR etc complete. A door should be provided at a height of 500mm from the base plate for accommodating and including provision of TPN aluminium bus bar system suitable for connecting upto 4 core, 25 sqmm aluminium cable and 01 No. of 6A SP MCB for street light protection inside the pole shaft. Radium reflector band / strips of 5cm wide in Green (02 Nos) & White (01 No.) colour shall be provided at a height of 1.25mtr from base plate. Numbering of pole shall be done in black colour on yellow background at suitable place on the pole complete as directed by Engineer-in-Charge. 10 Each
24 22 M&L for preparation of old painted surfaces of DG Set of capacity upto 62.5 KVA by cleaning the outer surfaces with costic soda, removing the grease, oil, carbon over the surfaces and applying two coats of Duco paint of approved colour with spray machine for body of engine and alternator, synthetic enamel black paint for base frame & radiator, red paint for fly wheel guard and writing MES number on body of both engine and alternator complete all as specified and directed by Engineer-in-Charge. 2 Each Job
25 23 Supply and fix maintenance free battery 12V, 80 AH for DG set including initial charging complete all as specified and directed by Engineer-in-Charge 1 Each
26 24 Supply and fix battery 12V, 150 AH for DG set including initial filling & charging complete all as specified and directed by Engineer-in-Charge 1 Each
27 25 M&L for taking down carefully window type AC of 1.5/2.0 TR capacity, any type/make, from window/wall and removing power connection and front PVC grills, air filters, cleaning, washing, removing dirt, servicing including chemical wash of cooling and condenser coil and re-assembling the dismantled components and fixing to its original position, complete all as directed. 2 Each Job
28 26 M&L for servicing of split type AC of 1.5/2.0 TR capacity, any type/make, at site /wall and removing power connection and front PVC grills, air filters, cleaning, washing, removing dirt, servicing including chemical wash of cooling coil of indoor cooling unit and condenser coil of outdoor unit and re-assembling the dismantled components and fixing to its original position complete all as directed. Note : The cost of additional inlet/outlet copper pipes, drain pipe and electrical cord, if required and making good of surface as original by plastering / whitewash / colour / distemper etc is included in quoted rate and no extra payment will be made to contractor in this effect. 5 Each Job
29 27 M&L for servicing of water cooler of any capacity, type/make, at site and removing power connection and drain out water, cleaning, washing, removing dirt, try cleaning, including re-assembling the dismantled components and fixing to its original position and testing the machine to its optimum efficiency complete all as directed. 7 Each Job
30 28 M&L for shifting of Split type AC of any type/make but of 1.5/2.0 TR capacity alongwith stabilizer including taking down carefully indoor and outdoor unit, copper piping, drain pipe and thermal sleeve, lifting angle etc and installing the same to new location using copper piping of suitable gauge for suction and delivery with insulation, drain pipe and re-fixing arrangement i.e. gas top up, lifting angle, fasteners, nut bolt, washer etc with and incl testing & commissioning, complete all as directed. Note : 1. The cost of making hole for passing through inlet/outlet copper pipes, drain pipe and electrical cord and making good of surface at both location as original by plastering / whitewash / colour / distemper etc is included in quoted rate and no extra payment will be made to contractor in this effect. 2. The copper piping, as required, will be measured and paid separately under respective items only. 2 Each Job
31 29 M&L for shifting of window type AC of any type/make but of 1.5/2.0 TR capacity alongwith stabilizer from one location to another complete with and including making of suitable opening OR removing aluminum grill and/or glass pane from existing window, with and incl supply and fixing of new wooden frame of suitable size and thickness for proper fixing of outer chassis of AC at new location, making good of disturbed surface as original etc, with and incl testing & commissioning, complete all as directed. Note : The cost of making suitable opening in brick wall or removing aluminum grill and/or glass pane from existing window and making good of surface at both location as original by brick work, plastering / whitewash / colour / distemper etc is included in quoted rate and no extra payment will be made to contractor in this effect. 1 Each Job
32 30 S&F, in replacement of hermetically sealed reciprocating / rotary type compressor unit of 1.5 TR capacity complete for 1.5 ton Window type/split type Air conditioners including gas charging complete all as directed. 2 Each
33 31 All as per item No 30 here-in-above but of capacity 2 ton. 2 Each
34 32 M&L for gas charging of Air Conditioner window/split type of capacity 1.5/2.0 Ton with R - 22 / R-410 or any other recommended refrigerant gas, including detecting of leakage, repairing using welding/brazing, pressure tesing, replacement of connection lead, tin coated copper thimbles and installation of AC at site and testing on full load for 24 hours continuously and six month top up warranty etc complete all as directed. 4 Each Job
35 33 Taking down fan blower motor from window air conditioner of any make/type for 1.5 Ton / 2.0 ton capacity and replacing with the new motor of same rating, copper wound, single phase, 200/230 volt, 50 Hz, in the same position, with and incl fixing arrangements i.e. nut, bolt, washer etc complete all as directed. 2 Each
36 34 S&F, in replacement of starting relay suitable for air conditioner of any make / type / capacity including making connection etc, complete all as directed. 3 Each
37 35 S&F, in replacement of window AC Kit, company made, consist of metal sheet enclosure/housing, cooling coil, condenser coil, PVC front grill, wiring kit, Fan motor, condenser fan and blower, PCB and remote hand set etc complete, suitable for air conditioner of 1.5 Ton capacity, completely all as specified. 1 Each
38 36 S&F, in replacement, of split AC outdoor unit Kit of 1.5 TR capacity, company made, consist of metal sheet enclosure/housing, condenser coil, wiring kit, condenser fan motor, condenser fan and blower, PCB etc complete, suitable for split air conditioner of any make but of 1.5 Ton capacity, complete all as directed. 1 Each
39 37 All as per Srl item No 36 here in before but for AC of 2.0 TR capacity. 1 Each
40 38 S&F in replacement of temperature control relay with digital display ranging from 0 to 50°C for cooling purpose, complete all as directed. 3 Each
41 39 S&F, in replacement, of indoor cooling unit complete, suitable for split air conditioner of any make but of 1.5 Ton capacity with and incl making connection etc, complete all as directed. 1 Each
42 40 All as per Srl item No 39 here in before but for AC of 2.0 TR capacity. 1 Each
43 41 M&L for MS work, for AC & cooler stand fabricated from MS channel, angle iron, flat iron of any size with and incl all machine wks i.e. welded, cutting, grinding, drilling of holes of suitable size etc with and including nuts, bolts and washers etc, as required and fixing the same on any level of the building, including painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as directed. 50 KG
44 42 S&F of PVC pipe 25mm, medium grade with and including all fitting i.e. elbow, bend, Tee, etc suitable to connect Window/split type AC drain line to nearby rain water pipe or any other pipe/drain with and incl fixed on wall with necessary clamping arrangement, complete all as directed. 15 RM
45 43 S&F in replacement of flexible foam type insulation suitable for insulating the suction and discharge line of split AC, suitable for split air conditioner of any make / type / capacity, complete all as specified. 30 RM
46 44 S&F, in replacement, of electronic control circuit card i.e. PCB suitable for air conditioner of any make / type / capacity, with and incl making all connection etc, complete all as directed. 3 Each
47 45 S&F, in replacement of MCB, C Curve type, 10 kA, 10 to 32 Amp, Single Pole with over load and short circuit protection, complete all as directed. 5 Each
48 46 S&F in replacement of MCB protected modular type AC/Geyser box complete with and including 6 pin socket, plug top, modular cover plates, mini MCB SP 25 Amp capacity, fixed on concealed modular type metal flush box of suitable size, complete all as specified and directed. 3 Each
49 47 S&F in replacement of plug top for industrial type enclosure with a two pin and earth as per sample, complete all as specified and directed. 2 Each
50 48 S&F in replacement PVC insulated and FR PVC Round Sheathed, Copper Conductor, 3 Core, 2.5 Sq mm (flexible) industrial cable, 1100 Volts, conforming to IS: 694, complete all as specified and directed. 10 RM
51 49 Supply only in replacement of remote with battery cell for operation of Split AC & window AC, suitable for air conditioner of any make / type / capacity, complete all as specified and directed. 3 Each
52 50 S&F, in replacement of fan blower motor of same rating as original, copper wound, single phase, 200/230 volt, 50 Hz, fixed in the same position, suitable for indoor unit of split type AC of any make / type / capacity (1.5 TR /2.0 TR), complete all as specified and directed. 2 Each
53 51 S&F, in replacement of fan blower motor of same rating as original, copper wound, single phase, 200/230 volt AC, 50 Hz, fixed in the same position, suitable for outdoor unit of split type AC of any make / type / capacity (1.5 TR /2.0 TR), with and incl replacement of foundation bolts, rubber pad etc complete all as specified and directed. 2 Each
54 52 S&F, in replacement of starting capacitor 80 to 120 mfd . 6 Each
55 53 S&F in replacement running capacitor 45 mfd to 60 mfd. 6 Each
56 54 S&F in replacement running capacitor 30 mfd to 36 mfd. 6 Each
57 55 S&F in replacement running capacitor 4 mfd to 10 mfd. 6 Each
58 56 S&F, in replacement, of thermostat switch of temperature range of 18°C to 30°C, suitable for air conditioner of any make / type / capacity including making connection etc, complete all as directed. 4 Each
59 57 S&F of copper tubing of any size for suction & discharge, suitable for split type AC of any make / type / capacity, complete all as specified and directed. 20 RM
60 58 M&L for detecting the leakage in refrigerant system of refrigerator of 165 to 310 ltr capacities, single phase, repairing it by welding/brazing, pressure testing at required pressure of 150 PSI with charging of nitrogen gas for 24 hrs, with and including charging of refrigerant R-134A/R-22 or any other recommended refrigerant gas, complete all as directed. Note:- The gas charging / servicing / leakage repair of compressor shall be repeated as and when required to improve the cooling efficiency of machine as per the direction of Eng-in-Charge. No extra payment shall be made in this effect. 2 Each Job
61 59 S&F in replacement of gas oil filter unit suitable for refrigerator of any make/type/capacity, complete all as directed. 3 Each
62 60 S&F, in replacement, of electronic control circuit card i.e. PCB suitable for refrigerator of any make / type but capacity upto and incl 310 Ltr, with and incl making all connection etc, complete all as directed. 2 Each
63 61 S&F, in replacement, of refrigerator condenser coil of copper, suitable for refrigerator of any make / type but capacity upto and incl 310 Ltr, with and incl making all connection etc, complete all as directed. 2 Each
64 62 S&F in replacement of hermetically sealed reciprocating type compressor unit suitable for refrigerator/deep freezer of 165 to 310 ltrs capacity of any make / type, medium temperature range, including replacement of foundation bolts, rubber pad, strainer, capillary tubes, suction and discharge pipe line etc, with and including gas charging, complete all as directed. 2 Each
65 63 M&L for detecting the leakage in refrigerant system of deep freezer of upto and incl 310 ltr capacity, single phase, repairing it by welding/brazing, replacing defective copper tubing with new copper tube as required, pressure testing at required pressure of 150 PSI with charging of nitrogen gas for 24 hrs, with and including charging of refrigerant R-134A/R-22 or any other recommended refrigerant gas, complete all as directed. Note:- The gas charging / servicing / leakage repair of compressor shall be repeated as and when required to improve the cooling efficiency of machine as per the direction of Eng-in-Charge. No extra payment shall be made in this effect. 2 Each Job
66 64 S&F, in replacement of fan motor of same rating as original, copper winding, single phase, 230 volt AC, 50 Hz, ISI marked, fixed in the same position, suitable for deep freezer of any make / type / capacity, with and incl replacement of foundation bolts, rubber pad etc, complete all as specified and directed. 2 Each
67 65 S&F, in replacement of relay and capacitor Kit suitable for deep freezer of any make / type / capacity, with and incl making all connections, complete all as directed. 2 Each
68 66 S&F, in replacement of relay and capacitor Kit suitable for refrigerator of any make / type but capacity upto and incl 310 Ltr, with and incl making all connection etc, complete all as directed. 2 Each
69 67 S&F, in replacement of fan motor unit of same rating as original, copper winding, single phase, 230 volt AC, 50 Hz, ISI marked, fixed in the same position, suitable for double door refrigerator of any make / type but capacity upto 310Ltr with and incl making all connection etc, complete all as directed. 1 Each
70 68 S&F in replacement of Freezer Unit complete, suitable for refrigerator of any make / type but capacity upto and incl 310 Ltr, with and incl testing and commissioning, complete all as directed. 1 Each
71 69 Supply and fix wall mounting type automatic voltage stabilizer for low and high voltage correction equipped with electric transmission relay suitable for correction on single phase 50 cycles, AC supply complete with time delay relay volt meter for working voltage 140 V to 280 V and stabilized voltage between 220 + 5 % of capacity 5 KVA fitted on wall complete and testing on full load. 2 Each
72 70 Supply and fix wall mounting type automatic voltage stabilizer for low and high voltage correction equipped with electric transmission relay suitable for correction on single phase 50 cycles, AC supply complete with time delay relay volt meter for working voltage 140 V to 280 V and stabilized voltage between 220 + 5 % of capacity 4 KVA fitted on wall complete and testing on full load. 2 Each
73 71 S&F of factory made wall mounted/floor mounted type AC outdoor unit stand of superior quality duly powder coated, suitable for AC of 1.5/2.0 TR capacity complete all as directed. 3 Each Set
74 72 S&F, in replacement of hermetically sealed reciprocating type compressor suitable for water cooler of capacity upto 60/120 Ltr, including gas charging complete all as directed. 3 Each
75 73 M&L for detecting the leakage in refrigerant system of Water cooler of any make / type / capacity, single phase, repairing it by welding/brazing, with and incl replacing capillary tube, gas filter, defective copper tubing with new copper tube as required, pressure testing at required pressure of 150 PSI with charging of nitrogen gas for 24 hrs, with and including charging of refrigerant R-410/R-22 or any other recommended refrigerant gas, complete all as directed. Note:- The gas charging / servicing / leakage repair of compressor shall be repeated as and when required to improve the cooling efficiency of machine as per the direction of Eng-in-Charge. No extra payment shall be made in this effect. 3 Each Job
76 74 S&F, in replacement of fan motor of same rating as original, copper winding, single phase, 230 volt AC, 50 Hz, ISI marked, fixed in the same position, suitable for water cooler of any make / type / capacity, with and incl all fixing accessories i.e. nut, bolt, washer etc and making all connection etc, complete all as directed. 3 Each
77 75 S&F, in replacement of chromium plated self closing push cock tap, suitable for water cooler of any make / type / capacity including all fixing accessories etc, complete all as directed. 3 Each
78 76 S&F, in replacement of starting relay, ISI Marked, suitable for water cooler of any make/type/capacity with and including making all connection etc, complete all as directed. 3 Each
79 77 S&F, in replacement of thermostat switch with knob, ISI marked suitable for water cooler of any make/type/capacity with and including making all connection etc, complete all as directed. 3 Each
80 78 S&F, in replacement of capacitor of suitable capacity, suitable for water cooler of any make/type/capacity with and including making all connection etc, complete all as directed. 4 Each
81 79 S&F, in replacement of PVC heavy duty waste water pipe of 32/40 mm size and min 1.5 mtr long, including repair of waste water tray, suitable for water cooler of any make / type / capacity with and including all fixing accessories etc, complete all as directed. 5 Each
82 80 S&F in replacement of PVC float valve of 15mm bore size with and including one number socket/reducer, suitable for water tank of water cooler and desert cooler of any make / type / capacity, complete all as directed. 20 Each
83 81 S&F in replacement of plug top 16 Amp, three pin, 240 volts, AC, complete all as directed. 15 Each
84 82 Taking down desert coolers of any capacity by disconnecting all the electrical connections, removing side panels, cleaning complete and painting the coolers with two coats of synthetic enamel paint out side and moisture resistance primer inside with spray painting and fixing back the removed panels and reconnecting with electrical connections and writing the MES No complete all as specified and directed by Engineer-in-Charge. Note: Rewinding of fan motor and spare parts required shall be measured and paid separately under relevant items. 25 Each Job
85 83 Supply and fix in replacement of Submersible water pump suitable for desert coolers of any capacity 15 Each
86 84 Supply and fix in replacement of cooling pads (set of 3 Nos) for the evaporative desert coolers of any capacity. 25 Each Set
87 85 Supply and fix in replacement of PVC hose pipe along with necessary fittings ad PVC distributor suitable for existing model of desert coolers of any capacity 25 Each Set
88 86 Supply and fix in replacement of Rotary/ piano type switch suitable for existing model of desert coolers of any capacity. 15 Each
89 87 Supply and fix in replacement of Fan blade set suitable for existing model of desert coolers of any capacity. 10 Each
90 88 Cutting and removing of old burnt/damaged winding, cleaning of slots and other parts and rewinding the desert cooler fan motor with super enameled copper winding wire of existing gauge with suitable class of insulation, applying varnish, heating, drying, assembling and testing for satisfactory performance complete all as specified and directed by Engineer-in-Charge. 10 Each Job
91 89 M&L for sub main wiring with 2 x 4 sqmm + 1 x 4 sqmm FRLS insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm concealed in wall/ floor etc including taking down existing sub main wiring of any description complete all as specified and directed by Engineer-in-Charge.\n 40 RM
92 90 M&L for sub main wiring with 2 x 6 sqmm + 1 x 6 sqmm FRLS insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm concealed in wall/ floor etc including taking down existing sub main wiring of any description complete all as specified and directed by Engineer-in-Charge.\n\n 30 RM
93 90.01 Notes for Ser Item No 89 & 90 :- \n(a) Three runs of copper cable and one run of PVC conduit shall be measured as one unit length.\n(b) Quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface.\n(c) If any beam / column / Rock wall is encountered while cutting chases, that particular portion may be provided with PVC casing & capping or surface conduit for drawing cables to avoid any damage to the structure. \n(d) No cutting shall be done on ceiling for laying PVC conduit. Surface conduit or PVC casing capping may be used in that portion. \n(e) Quantum of work at each particular location shall be as directed by Engineer-in-Charge. Contractor shall not have any claim on quantum of work at each particular location and the quoted rate shall deemed to be inclusive of this provision.
94 91 Taking down ceiling fan of any size carefully, sealing cable end, dismantling blades and removing fan and blades to store for servicing including supply replacing bearings/bushings, capacitor and terminal connector including capacitor holder suitable for any model of existing fan, Painting of ceiling fans complete, with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc and Hanging ceiling fan in its existing or new location and connecting up including provision of cable from ceiling rose or connector to fan and testing for satisfactory functioning complete all as specified and directed by Engineer-in-Charge.\nNote: Rewinding if required shall be measured and paid separately.\n 100 Each Job
95 92 All as per item No 91 here-in-before but of Exhaust fan of any size. Note: Rewinding if required shall be measured and paid separately.\n 20 Each Job
96 93 Shifting of ceiling fan 1200mm / 1400mm sweep to workshop, cutting and removing of old burnt/damaged winding, cleaning of slots and other parts and rewinding the ceiling fan motor with super enameled copper winding wire of existing gauge with suitable class of insulation, applying varnish, heating, drying, assembling and testing for satisfactory performance complete all as specified and directed by Engineer-in-Charge. .\n 50 Each Job
97 94 All as per item No 93 here-in-before but exhaust fan of size up to 450mm sweep. 10 Each Job
98 95 Supply and fix in replacement of customized Fan clamp made out of 3mm thick MS flat bent to required shape as per site requirement fixed with suitable size of number of nuts, bolts & washers etc suitable for fixing down rod including painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge. 20 Each\nSet
99 96 Supply and fix in replacement of Fan down rod of suitable size up to one meter long as per site requirement, having suitable holes on top and bottom of rod for inserting bolts and for drawing wires etc complete all as specified and directed by Engineer-in-Charge. 20 Each\nSet
100 97 Supply only standard GI fan clamp with rubber bush, bolts, nuts, spring washers & split pins etc complete all as specified and directed by Engineer-in-Charge. 30 Each\nSet
101 98 Supply only electronic fan regulator rotary type in 5 steps 100W, 240V, 50Hz complete all as specified and directed. \n 50 Each
102 99 Supply only switch piano, 6A, Single pole, flush type, 230 V, 50 Hz complete all as specified and directed. 50 Each
103 100 Supply only PVC insulated and PVC sheathed white coloured twin core flat cable with 0.75 sqmm stranded copper conductor conforming to IS:694. 1 Hundred Mtr coil
104 101 Taking down carefully the electric storage type water heater of capacity up to 50 ltrs from its installed position by disconnecting all water and electric supply connections for necessary repairs, opening the geyser carefully, identifying and replacing the defective parts, reassembling and reinstalling in its existing location or new location and testing for proper functioning complete all as specified and directed by Engineer-in-Charge. \nNote: The spare parts required shall be measured and paid separately under relevant items as "Supply Only". 30 Each Job
105 102 Supply only heating element 1500 Watts / 2000 Watts of any type suitable for existing model of geyser 25L/50L. 20 Each
106 103 Supply only thermostat of any type suitable for existing model of geyser 25L/50L 20 Each
107 104 Supply only apparatus plate of any type suitable for existing model of geyser of capacity 25L/50L. 10 Each
108 105 Supply only indicator lamp Red or Green of any type suitable for existing model of geyser of capacity 25L/50L. 20 Each
109 106 Supply and fix in replacement of flexible PVC connection 450mm long suitable for Hot/Cold water application. 10 Set of Two
110 107 Supply and erection in replacement of Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.00 metres long) including painting of poles with two coats of aluminium paint over a coat of red oxide primer on all exposed surfaces and black bituminous paint on embeded portion complete all as specified and directed by Engr-in-Charge. (Note: Excavation and concrete shall be measured and paid separately under relevant items of this Schedule 'A') 5 Each
111 108 M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundations for erection of pole/ stay assembly complete all as specified and directed by Engineer-in-Charge. 4 Cum
112 109 M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate set in CM 1:6 for coping of pole including necessary form work complete all as specified and directed by Engineer-in-Charge. 1 Cum
113 110 Supply and fix in replacement of Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed by Engineer-in-Charge. 1 Quintal
114 111 Supply and fix in replacement of Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade complete all as specified and directed by Engineer-in-Charge. 9 Each
115 112 Supply and fix in replacement of Disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green, single disc assembly for tension with tension clamps for conductors, working pressure 11000 volts complete all as specified and directed by Engineer-in-Charge. 6 Each
116 113 M&L for preparation of old painted surfaces of HT 11 KV two pole structure and painting with aluminium paint on all steel surfaces such as poles, channels, angles, clamps, nuts, bolts and washers of any description including zebra marking with black paint upto 1.50 m height from coping of pole complete all as specified and directed by Engineer-in-Charge. 1 Each Job
117 114 Supply and fix in replacement of Switch Air Break, gang operated, Triple pole, mechanically operated, horizontal or vertical mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps suitable for 11000 volts grade complete all as specified and directed by Engineer-in-Charge. 1 Each Set
118 115 Supply and fix in replacement of 11000 volts grade, expulsion type fuse set mounted on insulators and steel frame of current rating upto 50 Amps complete all as specified and directed by Engineer-in-Charge 1 Set of Three
119 116 M&L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95/120 sqmm complete all as specified and directed by Engineer-in-Charge. 2 Each
120 117 M&L for Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95/120 Sqmm complete all as specified and as directed by Engineer-in-Charge. 1 Each
121 118 M&L for replacement of GI Pipe, 'light grade' 80 mm bore fixed to poles or laid in trenches for cable protection complete all as specified and directed by Engineer-in-Charge. 12 RM
122 119 M&L for replacement of GI Pipe, 'light grade' 50 mm bore fixed to poles or laid in trenches for cable protection complete all as specified and directed by Engineer-in-Charge. 12 RM
123 120 Isolating the transformer by carefully disconnecting the HT/LT and earth connections, drawing out the oil from transformer to required level and storing in cleaned containers, opening the top cover and conservator tank from transformer, rectifying the defects and re-fixing back the same duly replacing with new rubberised cork sheet gasket for transformer top cover and new GI bolts, nuts & washers of suitable size and making all HT/LT connections as per the original, re-filling the transformer oil to required level and testing on completion all as specified and directed by Engineer-in-Charge for the following capacity of transformers:- Note : Re-winding and replacement of HT / LT bushings shall be measured and paid separately. However, the cost of rectification of minor defects such tightening of loose connections, connecting of copper strips to bushings, provn of nuts, bots, washers etc.is deemed to be included in quoted rates.
124 120.01 Distribution transformer upto 500 KVA, 11/0.433 KV 1 Each Job
125 120.02 Power transformer upto 500 KVA, 33/0.433 KV or 33/11 KV 1 Each Job
126 121 Taking out the transformer from its plinth inside the fence area with the help of suitable crane and transporting the transformer to workshop for carrying out necessary repairs and bringing back and re-installaing in its original place complete all as specified and directed by Engineer-in-Charge for the following capacity of transformers:-
127 121.01 Distribution transformer upto 500 KVA 1 Each Job
128 121.02 Power transformer upto 500 KVA 1 Each Job
129 122 Taking out complete core from transformer, cutting and removing burnt out winding and re-winding the same with super enameled copper conductor of existing guage together with insulation materials, applying varnish, pre-heating in heating chamber, re-assembling the transformer as per the original and testing on completion complete all as specified and directed by Engineer-in-Cahrge for distribution / power transformers of capacity upto 500 KVA. 300 KG
130 123 Topping up of transformer oil into the body/ conservator tank of transformer to the desired level complete all as specified and directed by Engineer-in-Charge. Note: The dielectric strength of oil should not be less than 40 KV at 2.5mm gap. 400 Litre
131 124 M&L for trimming of tree branches around HT/LT overhead lines and depositing where directed at a distance not less than 50m complete all as specified directed by Engineer-in-Charge. Note: The item will be measured in span length. The approx span length is 40m. 50 Each Span
132 125 Supply and fix in replacement of MCCB 3 Pole, 415 V fixed thermal and fixed magnetic setting, 25 to 100 Amps with breaking capacity 25 KA including spreader terminals and connecting up with suitable lugs complete all as specified and directed by Engineer-in-Charge 5 Each
133 126 Supply and fix in replacement of MCCB 4 Pole, 415 V, adjustable thermal and fixed magnetic setting, 200 Amps with breaking capacity 36 KA including spreader terminals and connecting up with suitable lugs complete all as specified and directed by Engineer-in-Charge. 2 Each
134 127 Supply and fix in replacement of MCCB 4 Pole, 415 V, adjustable thermal and fixed magnetic setting, 250 Amps with breaking capacity 36 KA including spreader terminals and connecting up with suitable lugs complete all as specified and directed by Engineer-in-Charge. 2 Each
135 128 Supply and fix in replacement of MCCB 100A, 25KA, 4 Pole with fixed thermal magnetic release mounted in MCCB sheet steel enclosure including spreader terminals and connecting up with suitable lugs complete all as specified and directed by Engineer-in-Charge. 8 Each
136 129 Supply and fix in replacement of On-Load Changeover switch 4 Pole, 250A, 415 V in sheet steel enclosure with front operated handle and connecting up with suitable lugs complete all as specified and directed by Engineer-in-Charge. 1 Each
137 130 Excavation in post holes (or similar holes) each not exc 0.5 Cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exc 25cm, watering, and removing surplus soil to a distance not exc 50m and making good surface complete in any type of soil. 40 Each
138 131 M&L for mild steel work as in replacement of posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc flat iron filltets(for securing wire mesh etc) including all necessary drilling, bolting or reveting etc and similar work confirming to Fe-290 Gde E-165 complete all as specified and directed. 250 KG
139 132 M&L for preparation of new steel surfaces of any description not exc 10 cm in width or girth and painting with two coats of synthetic enamel paint of approved colour over a coat of red oxide primer complete all as specified and directed. 100 RM
140 133 Supply and fix in replacement of coloured PVC covered galvanised chain link fencing of size 50mm x 50mm mesh, dia of wire 2.5mm with 1.5mm PVC cover (overall dia 4mm) including line wires fixed to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed. 120 Sqm
141 134 M&L for Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc. conforming to Fe.290.Gde-E-165 including taking down existing framed work of any description complete all as specified and directed by Engineer-in-Charge. 130 KG
142 135 M&L for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc conforming to Fe.290.Gde-E-165 including taking down existing framed work of any description complete all as specified and directed by Engineer-in-Charge. 50 KG
143 136 Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard/dense soil in the transformer yard complete all as specified and directed by Engineer-in-Charge. 400 Sqm
144 137 Supply and spread graded coarse aggregate of 63mm nominal size around outdoor transformer and HT 11 KV two/four pole structure complete all as specified and directed. 50 Cum
145 138 Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth and getting in any type of soil for laying of cables/ for erection of poles/ for stay assembly etc complete all as specified and directed by Engineer-in-Charge. 200 Cum
146 139 Supply and spread M-sand in trenches for cushioning of cable / in the yard of outdoor substations complete all as specified and directed by Engineer-in-Charge. (Note: Punned down thickness only shall be measured for the purpose of payment) 40 Cum
147 140 Returning, filling in trenches including spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed by Engineer-in-Charge. 185 Cum
148 141 Removing surplus excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge. 15 CuM
149 142 Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm for cable protection 1400 Each
150 143 M&L in replacement of Power Cables, Aluminum Stranded Conductor, XLPE Insulated, Cores Laid Up, PVC Innersheathed, Armoured Glavanised Wire or Galvanised Steel Strip, PVC Sheathed, 1100V Grade As Per IS 7098(Part 1) 1988 complete laid in trenches / floors / fixed to poles/walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting as per site requirement and testing on completion for the following cable sizes:- Note:- Excavation, earth work and provn of cable protection pipe shall be measured and paid separately under relevant items.
151 143.01 95 sqmm, 3.5 core 250 RM
152 143.02 70 sqmm, 3.5 core 300 RM
153 143.03 35 sqmm, 3.5 core 200 RM
154 143.04 16 sqmm, 4 core 250 RM
155 144 Material and labour for Cable jointing kit for 1100 Volts grade cable for straight through joint(Cold applied insulations and sealing system) complete with jointing material and accessories suitable for 3.5/4 core XLPE/PVC insulated armoured aluminium conductor cable of size 120 sqmm to 185 sqmm sqmm complete all as specified and directed by Engineer-in-Charge. 2 Each
156 145 All as per item No 144 here-in-before but of size 3.5/4 core, 70 sqmm to 95 sqmm. 2 Each
157 146 All as per item No 144 here-in-before but of size 3.5/4 core, 25 sqmm to 50 sqmm. 2 Each
158 147 Unbinding the existing HT/LT overhead lines of any configuration and size of conductor by opening the binding wire from insulators and Re-stringing to required tension and sag and binding with new aluminium binding wire of suitable gauge complete all as directed by Engineer-in-Charge. 3 Quintal
159 148 Material and labour for Shackle Type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts for working pressure 1100 volts of size 75mm height and 90mm dia complete all as specified and directed by Engineer-in-Charge. 20 Each
160 149 Material and labour for Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade complete all as specified and directed by Engineer-in-Charge. 25 Each
161 150 Supply and fix in replacement of ACSR conductor for HT/LT overhead line and proper stringing to required tension and sag including binding with new aluminium binding wire of suitable size complete all as specified and directed by Engineer-in-Charge. 2 Quintal
162 151 Supply and fix in replacement of Stay assembly with 16mm dia stay rod and all accessories as shown in electrical plate No. 1 complete all as specified and directed by Engineer-in-Charge. Note: Loop type insulator, stay clamps, stay wire, excavation and concrete measured separately) 5 Each
163 152 Supply and fix in replacement of Galvanised stay strand, 7/3.15mm including proper tightening to required tension complete all as specified and directed by Engineer-in-Charge. 0.3 Quintal
164 153 Supply and fix in replacement of Loop type insulator, vitreous porcelain, white, brown or green Small size, with overall dimensions 65 x 90mm, clearance of hole 16mm complete all as specified and directed by Engineer-in-Charge. 5 Each
165 154 Supply only aluminium cable lug / ferrule of size suitable for 300/240 Sqmm aluminium cable. 20 Each
166 155 Supply only aluminium cable lug / ferrule of size suitable for 185/150 Sqmm aluminium cable. 30 Each
167 156 Supply only aluminium cable lug / ferrule of size suitable for 120/95 Sqmm aluminium cable. 40 Each
168 157 Supply only aluminium cable lug / ferrule of size suitable for 70/50 Sqmm aluminium cable. 50 Each
169 158 Supply only aluminium cable lug / ferrule of size suitable for 35/25 Sqmm aluminium cable. 100 Each
170 159 Supply and fix in replacement of ON/OFF indicator Assy with spring / Charge free indicator Assy with spring suitable for 11 KV / 33 KV VCB Panel complete all as specified and directed by Engineer-in-Charge. 3 Each
171 160 Supply and fix in replacement of space heater with thermostat suitable for 11 KV / 33 KV VCB Panel complete all as specified and directed by Engineer-in-Charge. 2 Each set
172 161 Supply and fix in replacement of Power Pack with 15 minutes backup suitable for HT Panel 11 KV / 33 KV complete all as specified and directed by Engineer-in-Charge. 1 Each
173 162 Calibration of IDMT relay by conducting primary injection and seondary injection tests, checking of current transformer, rectification of defects in control wiring, necessary adjustment/setting of plug and time multiplier settings of the relay for proper tripping of circuit brakers through CTs, relays and tripping coils complete all as specified and as directed. NOTE:- Quoted rate is deemed to be inclusive of necessary testing kits, testisng equipments, tools etc and Testing and tuning shall be carried out in the presence of Engineer-in-Charge. 2 Each Job
174 163 S&F in replacement of Triple Pole Combined Over Current and Earth Fault (two over current and one earth fault) IDMT relay suitable for 1 Amp or 5 Amp CT secondary 11 KV / 33 KV system for smooth functioning of relay with necessary cutting and making good the disturbed surface and necessary connection with copper wire and setting all as required at site complete all as specified and directed.\n 1 Each
175 164 S&F in replacement of Master Trip Relay suitable for 1 Amp or 5 Amp CT secondary 11 KV / 33 KV system for smooth functioning of relay with necessary cutting and making good the disturbed surface and necessary connection with copper wire and setting all as required at site complete all as specified and directed.\n 1 Each
176 165 Fabricate, supply, installation and testing of outdoor type cubicle panel board busbar box with MCCB suitable for 3 phase 4 wire, 50 Hz supply system factory fabricated made out of CRCA sheet steel of 3mm thick for outer shell and 2mm thick for inner shell with front openable door with locking arrangement complete with powder coat painting and suitable packing material for IP-54 degree of protection and including provision of 40mmx40mmx5mm angle iron base frame of suitable size for mounting the panel board at a height of 450mm above GL and grouted in PCC foundation. The size of panel board shall not be less than 500mm x 500mm x 300mm (outer dimensions) for accommodating and including provision of following switchgears complete:- \n(i) TPN Aluminium bus bar of 25 x 5 mm provided with heat shrinkable coloured PVC sleeve insulation mounted on insulators suitable for connecting 2 or 3 outgoing cables including provision suitable glands.\n(ii) MCCB, 160 Amps, 36 KA breaking capacity , 4 Pole, 415 V, 50 Hz, adjustable thermal and magnetic setting including spreader terminals - 01 No 6 Each
177 166 Preparation of old painted steel surfaces of indoor / outdoor type LT panel boards of any size and painting with synthetic enamel paint of approved colour over a coat of red oxide primer (both internally & externally) and fixing 02 Nos steel danger plates on panel board complete all as specified and directed by Engineer-in-Charge. 2 Each Job
178 167 Supply and fix in replacement of panel mounted digital type Voltmeter / Ammeter suitable for 3Ph, 415 Volts, 50 Hz supply system complete all as specified and directed by Enginner-in-Charge. 10 Each
179 168 Supply and fix in replacement of LT metering current transformer 200 / 5 A, tape wound for 3Ph, 415 Volts, 50 Hz supply system complete all as specified and directed by Enginner-in-Charge. 5 Set of Three
180 169 Supply and fix in replacement of panel mounting LED pilot light indication lamps for R/Y/B phases complete all as specified and directed by Enginner-in-Charge. 10 Each
181 170 Supply and fix in replacement of ammeter / voltmeter selector switch for 3 Ph, 415 Volts, 50 Hz supply system complete all as specified and directed by Enginner-in-Charge. 10 Each
182 171 M&L for earthing complete with galvanised iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connecting to GI strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth wire protected by 50mm dia GI pipe medium grade and connected to pole structure/ panel board/earthing test point all as shown in electircal plate No 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. \nNote : The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with 20mm light grade watering pipe, wire mesh,protection pipe, earth strip upto 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II\n 5 Each Job
183 172 M&L for earthing complete with galvanised iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connecting to 4mm dia GI wire as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth wire protected by 15mm dia GI pipe medium grade and connected to distribution board/earthing test point all as shown in electircal plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. \nNote : The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with 20mm light grade watering pipe, wire mesh,protection pipe, earth strip upto 7.50m long complete in addition to item No 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II\n 5 Each Job
184 173 M&L for Brickwork with sub class ‘B’ bricks in one brick thick walling, built in CM 1:6 15 Sqm
185 174 M&L for rendering 10mm thick cement plaster 1:6 on fair faces of brick work or concrete surfaces finished even and smooth (with out using extra cement) complete all as directed. 15 Sqm
186 175 M&L for Glow sign board of size 150cm x 90cm x 15cm, outdoor type, totally enclosed, made of 1.75mm thick milky white sheet with letters /matter by overlay color vinyl film, pasted over sheet, frame work made out of 26 gauge thick galvanised iron sheet and 50mm x 50mm x 5mm, MS angle iron with and incl LED tube lights 1x20 wtt - 03 Nos duly wired incluidng all standard accessories and making all electric connections with suitable size multistranded copper wire, including two coats of synthetic enamel painting over a coat of red oxide primer after preparation of steel surfaces, fixed at siteby grouting the legs in PCC 1:2:4 type B1 blcok of size 40cm x 40cm x 60cm, including dismantling & taking out old sign board complete all as specified and directed. Note: (a) The top of sign board shall be 2.0 mtr height above GL. (b) The cost of PCC is deemed to be included in quoted rates. (c) The excavation, earth work, MS angle with hold fasts etc will be measured and paid separately under relevant items (d) The letters / matter to be written on sign board shall be given by the Engineer-in-Charge as per location of sign board. 4 Each Job