| 1 | 1 | Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre depth foundation of poles, cables etc not exceeding 10 sqm on plan area and getting out in soft / loose soil including taking out brick protection complete all as specified and as directed. | | 100 | Cum |
|---|
| 2 | 2 | All as per item No 1.00 here-in-before but depth exc 1.50m and not exc 3.0m. | | 5 | Cum |
|---|
| 3 | 3 | Returning, filling in, of soil including spreading leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed . | | 75 | Cum |
|---|
| 4 | 4 | Removing excavated material to a distance n.exc 50M and deposited/ spreaded where directed at a level n. exc 1.5 M above the starting point complete all as specified and as directed . | | 30 | Cum |
|---|
| 5 | 5 | Materials and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of Under ground cable including spreading and punning down to desired thickness complete all as specified and as directed. | | 20 | Cum |
|---|
| 6 | 6 | Material and labour for PCC (1:3:6) type C2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed. | | 10 | Cum |
|---|
| 7 | 7 | Material and labour for PCC (1:2:4), type B1, (using 20mm graded stone aggregate), as in cills, coping, benching on chajja, roof kerbs, bed blocks and the like including weathering, slightly rounded or chamferred angles and throating with and including necessary formwork complete all as specified and as directed. | | 2 | Cum |
|---|
| 8 | 8 | Supply and fixing 80 mm bore dia GI pipe, light grade including all fittings laid under road crossings or fixed to pole including taking down old unserviceable pipe complete all as specified and directed. | | 18 | Rm |
|---|
| 9 | 9 | Supply and fixing 100 mm bore dia GI pipe, light grade including all fittings laid under road crossings or fixed to pole including taking down old unserviceable pipe complete all as specified and directed. | | 12 | Rm |
|---|
| 10 | 10 | Fixing only steel tubular swaged pole 11 metres long, 410-SP-55 complete with cast iron base plate, finial, taper plug, bolts nuts and screws etc complete all as specified and directed. (Note: Steel pole shall be issued under Schedule 'B' free for fixing) | | 4 | Each |
|---|
| 11 | 11 | Material and labour for Cross arm bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of zinc chrome primer complete all as specified and as directed. | | 2 | Qtl |
|---|
| 12 | 12 | Fixing only Cross arm bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of zinc chrome primer complete all as specified and as directed. (Note: Serviceable material retrivev from serial item No. 29 shall be re-used) | | 1 | Qtl |
|---|
| 13 | 13 | Supply and fixing Pin type insulator, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade confirming to IS-2486 including taking down old unserviceable insulator complete all as specified and as directed.\nMake: Jayashree/BHEL/ Mysore/ Rastriya. | | 15 | Each |
|---|
| 14 | 14 | Material and labour for anti-climbing device, spike type fabricated from structural steel comprising of MS flat 20mmx6mm, MS round bar pointed, 8mm dia, 20cm length welded on MS flat fixed with nuts, bolts, washers and welding with and including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer including taking down old unserviceable device complete all as specified and as directed. | | 1 | Qtl |
|---|
| 15 | 15 | Supply and fixing in replacement danger notice plate of 25x20cm size and 1.6mm thick mild steel sheet, vitreous enamelled white, with letters(Local & Hindi language), figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT pole complete all as specified and as directed. | | 10 | Each |
|---|
| 16 | 16 | Supply and fixing in replacement expulsion type drop out fuse single pole mounted on insulator for 11000 volt and current rating upto 100 Amps complete all as specified and as directed. \nMake: Pactil/BHEL/Jaypuria Brothers | | 20 | Each |
|---|
| 17 | 17 | Supply and fixing in replacement switches air break, gang operated triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps, 11000 Volts complete all as specified and directed. | | 20 | Each |
|---|
| 18 | 18 | Supply, install, testing and commissioning of lightening arrestor expulsion type complete with all fitings, transmission class, discharge capacity 65 KA suitable for working voltage of 11000 Volts including all necessary fittings all as per IS-3070 Part-III and IEC 1994 including dismantling of old unserviceable one complete all as specified and as directed.\nMake: Alpro/Areva/Oblum/Rastriya/Raychem/Bhal /ABB | | 5 | Each Set |
|---|
| 19 | 19 | Supplying, Laying connecting & testing XLPE insulated, PVC sheathed, armoured HT electric power UG cable (heavy duty with stranded aluminum conductor) of size 95 Sqmm, 3 core, 11000 Volts(Earthed) grade, confirming to IS-7098 (Part-II) laid through duct/ pipe / in trench etc. with cable glands & suitable size of aluminium lugs including taking down old unserviceable cable complete all as specified and as directed.\nMake: Havells/Glostar/KEC(RPG)/ CCI/ NICCO.\nNote : Earth work, brick protection and sand cushioning and GI Pipe Shall be measured and paid separately under respective item. | | 175 | RM |
|---|
| 20 | 20 | Supplying, Laying connecting & testing XLPE insulated, PVC sheathed, armoured HT electric power UG cable (heavy duty with stranded aluminum conductor) of size 120 Sqmm, 3 core, 11000 Volts(Earthed) grade, confirming to IS-7098 (Part-II) laid through duct/ pipe / in trench etc. with cable glands & suitable size of aluminium lugs including taking down old unserviceable cable complete all as specified and as directed.\nMake: Havells/Glostar/KEC(RPG)/ CCI/ NICCO.\nNote : Earth work, brick protection and sand cushioning and GI Pipe Shall be measured and paid separately under respective item. | | 100 | RM |
|---|
| 21 | 21 | Supply and fixing in replacement for HT 11 KV (Earthed) grade heat shrinkable end termination jointing kit outdoor type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm complete all as specified and as directed. \nMake: Raycem/ Denson/ M-Seal/3M. | | 2 | Each |
|---|
| 22 | 22 | Supply and fixing in replacement for HT 11 KV (Earthed) grade heat shrinkable end termination jointing kit outdoor type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm complete all as specified and as directed. \nMake: Raycem/ Denson/ M-Seal/3M. | | 2 | Each |
|---|
| 23 | 23 | Supply and fixing in replacement for HT 11 KV (Earthed) grade heat shrinkable end termination jointing kit straight through type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm complete all as specified and as directed. \nMake: Raycem/ Denson/ M-Seal/3M. | | 2 | Each |
|---|
| 24 | 24 | Supply and fixing in replacement for HT 11 KV (Earthed) grade heat shrinkable end termination jointing kit straight through type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm complete all as specified and as directed. \nMake: Raycem/ Denson/ M-Seal/3M. | | 2 | Each |
|---|
| 25 | 25 | Supply and fixing unreinforced precast concrete cable cover class HVP type 1 with peak size 300mm x 180 mm x 40 mm complete all as specified and directed. | | 1200 | Each |
|---|
| 26 | 26 | Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised wire of 4mm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 15mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed. | | 4 | Each Set |
|---|
| 27 | 27 | Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip 25x4mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed. | | 6 | Each Set |
|---|
| 28 | 28 | Dismantling of steel pole / struts etc complete all as specified and directed. | | 4 | Each |
|---|
| 29 | 29 | Dismantling of cross arms of MS channel or angle section etc complete all as specified and directed. | | 3 | Qtl |
|---|
| 30 | 30 | Dismantling of stay assembly complete all as specified and directed. | | 5 | Each Set |
|---|
| 31 | 31 | Dismantling of earthwire or cradle guard complete all as specified and directed. | | 1 | Qtl |
|---|
| 32 | 32 | Dismantling of overhead ACSR / AAC conductor from existing electric pole complete all as specified and directed. | | 2 | Qtl |
|---|
| 33 | 33 | Demolition of cement concrete (unreinforced) of any description or in any position not otherwise specifically provided for and removal of rubbish from the site complete all as specified and as directed. | | 2 | Cum |
|---|
| 34 | 34 | Boring of hole under road, pavement, hard standing by trenches technology using ultrasound technique and necessary machine including provision of 150 mm dia HDPE pipe PN6 complete all as specified and as directed. | | 15 | Rm |
|---|