Providing Ac Ducts And Air Cooling To Banjara Bhavan And Komaram Bheem Bhavan At Road No.10, Banjara Hills, Hyderabad, HYDERABAD-Telangana

Tribal Welfare Engineering Department has published Providing Ac Ducts And Air Cooling To Banjara Bhavan And Komaram Bheem Bhavan At Road No.10, Banjara Hills, Hyderabad. Submission Date for this Tender is 23-12-2019. Duct Supply Tenders in HYDERABAD Telangana. Bidders can get complete Tender details and download the document.




Tender Notice

22902858
Providing Ac Ducts And Air Cooling To Banjara Bhavan And Komaram Bheem Bhavan At Road No.10, Banjara Hills, Hyderabad
Open Tender
Indian
Telangana
HYDERABAD
23-12-2019

Tender Details

Providing Ac Ducts And Air Cooling To Banjara Bhavan And Komaram Bheem Bhavan At Road No.10, Banjara Hills, Hyderabad

Key Value

Document Fees
Refer document
EMD
INR 177000.0 /-
Tender Value
INR 1.76 Crore /-

BOQ Items

S.No Subwork Name Specification Number Quantity UOM Rate(INR) Amount(INR)
1 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 10.00 Each 335500.00 3355000.00
AC Ducts in Banjara Bhavan Supply of Blue Star make supply of Ductable Split Airconditioner fitted with Scroll compressor, air cooled condenser, thermostatic expansion value, Direct expansion evaporator coil, all controls and Microprocessor Pendant Control with R 407C refrigerant 22.0 TR Ductable Split Ac - Model No@DSA2421R2
2 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 10.00 Each 20000.00 200000.00
Installation of Blue Star make supply of Ductable Split Airconditioner fitted with Scroll compressor, air cooled condenser, thermostatic expansion value, Direct expansion evaporator coil, all controls and Microprocessor Pendant Control with R 407C refrigerant 22.0 TR Ductable Split Ac - Model No@DSA2421R2
3 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 400.00 1 Rmt 295.00 118000.00
Supply of SITC of Eletrical Cabling using copper cables interconnecting indoor nand outdoor units( Required incoming power supply with a switch (MCB) to be provided by you near our outdoor unit/Eletrical Panel) 6 Core X 2.5 Sqmm makes Polycab
4 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 400.00 1 Rmt 75.00 30000.00
Installation of SITC of Eletrical Cabling using copper cables interconnecting indoor nand outdoor units( Required incoming power supply with a switch (MCB) to be provided by you near our outdoor unit/Eletrical Panel) 6 Core X 2.5 Sqmm makes Polycab
5 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 20.00 Each 5500.00 110000.00
Supply of ODU Stands for condesning units etc., complete for finished item of work.
6 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 20.00 Each 500.00 10000.00
Installation of ODU Stands for condesning units etc., complete for finished item of work.
7 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 300.00 1 Rmt 1350.00 405000.00
Supply, Installation,Testing and Commissioning of copper refrigerant piping of various sizes as given below. The rate shall include Copper pipe and insulation with 13 mm Thick Nitrile rubber tube and necessary Installation accessories such as supports and clamps. The sizes given shall be verified by Supplier for adequacy and size based on manufacturer standards.
8 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 300.00 1 Rmt 250.00 75000.00
Installation,Testing and Commissioning of copper refrigerant piping of various sizes as given below. The rate shall include Copper pipe and insulation with 13 mm Thick Nitrile rubber tube and necessary Installation accessories such as supports and clamps. The sizes given shall be verified by Supplier for adequacy and size based on manufacturer standards.
9 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 200.00 1 Rmt 550.00 110000.00
Supply of CPVC drain piping 40mm dia with suitable supports as required and insulation of following sizes
10 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 200.00 1 Rmt 250.00 50000.00
Installation of CPVC drain piping 40mm dia with suitable supports as required and insulation of following sizes
11 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 50.00 1 Rmt 450.00 22500.00
Supply of CPVC drain piping 32mm dia with suitable supports as required and insulation of following sizes
12 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 50.00 1 Rmt 250.00 12500.00
Installation of CPVC drain piping 32mm dia with suitable supports as required and insulation of following sizes
13 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 220.00 1 Kg 1200.00 264000.00
Supply testing and commissioning of initial Charge of refrigerant gas etc., complete for finished item of work.
14 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 220.00 1 Kg 200.00 44000.00
Installation of testing and commissioning of initial Charge of refrigerant gas etc., complete for finished item of work.
15 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 20.00 Each 5500.00 110000.00
Installation of Nitrogen pressure testing and commissioing of the system
16 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 480.00 Each 750.00 360000.00
Supply, fabrication, testing of following sizes of Rectangular duct with TDS flange. Galvanized sheet metal ducting GI supports, angle iron flanges for all sizes of ducts, neoprene gaskets for all transverse joints, splitter dampers, tees, reducers, elbows etc., The frame shall slide over the duct ends to form flange connection. The flange connection shall be supplied with airtight seals. Ducts shall be suitably reinforced using diagonal bends, distance pieces, etc. A permanent non-etching, silicone free elastic sealing material shall be used 24 G, 0.63 mm thick
17 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 480.00 1 Sqm 250.00 120000.00
Installation of Rectangular duct with TDS flange. Galvanized sheet metal ducting GI supports, angle iron flanges for all sizes of ducts, neoprene gaskets for all transverse joints, splitter dampers, tees, reducers, elbows etc., The frame shall slide over the duct ends to form flange connection. The flange connection shall be supplied with airtight seals. Ducts shall be suitably reinforced using diagonal bends, distance pieces, etc. A permanent non-etching, silicone free elastic sealing material shall be used 24 G, 0.63 mm thick
18 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 225.00 1 Sqm 850.00 191250.00
Supply, fabrication, testing of following sizes of Rectangular duct with TDS flange. Galvanized sheet metal ducting GI supports, angle iron flanges for all sizes of ducts, neoprene gaskets for all transverse joints, splitter dampers, tees, reducers, elbows etc., The frame shall slide over the duct ends to form flange connection. The flange connection shall be supplied with airtight seals. Ducts shall be suitably reinforced using diagonal bends, distance pieces, etc. A permanent non-etching, silicone free elastic sealing material shall be used 22 G, 0.80 mm thick
19 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 225.00 1 Sqm 250.00 56250.00
Installation of Rectangular duct with TDS flange. Galvanized sheet metal ducting GI supports, angle iron flanges for all sizes of ducts, neoprene gaskets for all transverse joints, splitter dampers, tees, reducers, elbows etc., The frame shall slide over the duct ends to form flange connection. The flange connection shall be supplied with airtight seals. Ducts shall be suitably reinforced using diagonal bends, distance pieces, etc. A permanent non-etching, silicone free elastic sealing material shall be used 22 G, 0.80 mm thick
20 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 10.00 Each 3500.00 35000.00
Supply, fabrication, testing of following sizes of Rectangular duct with TDS flange. Galvanized sheet metal ducting GI supports, angle iron flanges for all sizes of ducts, neoprene gaskets for all transverse joints, splitter dampers, tees, reducers, elbows etc., The frame shall slide over the duct ends to form flange connection. The flange connection shall be supplied with airtight seals. Ducts shall be suitably reinforced using diagonal bends, distance pieces, etc. A permanent non-etching, silicone free elastic sealing material shall be used Canvas connections
21 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 10.00 Each 300.00 3000.00
Installation of Rectangular duct with TDS flange. Galvanized sheet metal ducting GI supports, angle iron flanges for all sizes of ducts, neoprene gaskets for all transverse joints, splitter dampers, tees, reducers, elbows etc., The frame shall slide over the duct ends to form flange connection. The flange connection shall be supplied with airtight seals. Ducts shall be suitably reinforced using diagonal bends, distance pieces, etc. A permanent non-etching, silicone free elastic sealing material shall be used Canvas connections
22 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 110.00 Each 8500.00 935000.00
Supply of removable core, heavy gauge, powder coated aluminum Supply Air Ceiling Jet nozzle etc., complete for finished item of work.
23 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 110.00 Each 750.00 82500.00
Installation of removable core, heavy gauge, powder coated aluminum Supply Air Ceiling Jet nozzle etc., complete for finished item of work.
24 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 8.00 1 Sqm 8800.00 70400.00
Supply of removable core, heavy gauge, powder coated aluminum Supply Air grill with volume control damper.
25 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 8.00 1 Sqm 750.00 6000.00
Installation of removable core, heavy gauge, powder coated aluminum Supply Air grill with volume control damper.
26 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 8.00 1 Sqm 8300.00 66400.00
Supply of removable core, heavy gauge, powder coated aluminum Return Air grill without volume control damper.
27 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 8.00 1 Sqm 500.00 4000.00
Installation of removable core, heavy gauge, powder coated aluminum Return Air grill without volume control damper.
28 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 12.00 1 Sqm 8900.00 106800.00
Supply, testing and commissioning of zero leak proof volume control dampers of GI sheet, box type to be provided in ducts complete with suitable links, levers and quadrants for manual control of air volume and air balancing
29 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 12.00 1 Sqm 1000.00 12000.00
Installation, testing and commissioning of zero leak proof volume control dampers of GI sheet, box type to be provided in ducts complete with suitable links, levers and quadrants for manual control of air volume and air balancing
30 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 10.00 1 Sqms 9500.00 95000.00
Supply of fusible link type fire damper of 16g GI casing & blades construction and fire rated for 90 minutes as per UL-555.
31 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 10.00 1 Sqms 1500.00 15000.00
Installation of fusible link type fire damper of 16g GI casing & blades construction and fire rated for 90 minutes as per UL-555.
32 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 830.00 1 Sqms 750.00 622500.00
Supply of Thermal for the supply air duct with 13 mm thick Nitrile rubber etc., complete for finished item of work.
33 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 830.00 1 Sqms 250.00 207500.00
Installation of Thermal for the supply air duct with 13 mm thick Nitrile rubber etc., complete for finished item of work.
34 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 1.00 1 Sqms 75000.00 75000.00
Transportation, lofting, shifting charges etc., complete for finished item of work.
35 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 1.00 1 Sqms 75000.00 75000.00
Installation of Transportation, lofting, shifting charges etc., complete for finished item of work.
36 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 10.00 Each 335500.00 3355000.00
AC Ducts in Kumaram Bhavan Supply of Blue Star make supply of Ductable Split Airconditioner fitted with Scroll compressor, air cooled condenser, thermostatic expansion value, Direct expansion evaporator coil, all controls and Microprocessor Pendant Control with R 407C refrigerant 22.0 TR Ductable Split Ac - Model No@DSA2421R2
37 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 10.00 Each 20000.00 200000.00
Installation of Blue Star make supply of Ductable Split Airconditioner fitted with Scroll compressor, air cooled condenser, thermostatic expansion value, Direct expansion evaporator coil, all controls and Microprocessor Pendant Control with R 407C refrigerant 22.0 TR Ductable Split Ac - Model No@DSA2421R2
38 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 400.00 1 Rmt 295.00 118000.00
Supply of SITC of Eletrical Cabling using copper cables interconnecting indoor nand outdoor units( Required incoming power supply with a switch (MCB) to be provided by you near our outdoor unit/Eletrical Panel) 6 Core X 2.5 Sqmm makes Polycab
39 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 400.00 1 Rmt 75.00 30000.00
Installation of SITC of Eletrical Cabling using copper cables interconnecting indoor nand outdoor units( Required incoming power supply with a switch (MCB) to be provided by you near our outdoor unit/Eletrical Panel) 6 Core X 2.5 Sqmm makes Polycab
40 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 20.00 Each 5500.00 110000.00
Supply of ODU Stands for condesning units etc., complete for finished item of work.
41 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 20.00 Each 500.00 10000.00
Installation of ODU Stands for condesning units etc., complete for finished item of work.
42 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 300.00 1 Rmt 1350.00 405000.00
Supply, Installation,Testing and Commissioning of copper refrigerant piping of various sizes as given below. The rate shall include Copper pipe and insulation with 13 mm Thick Nitrile rubber tube and necessary Installation accessories such as supports and clamps. The sizes given shall be verified by Supplier for adequacy and size based on manufacturer standards.
43 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 300.00 1 Rmt 250.00 75000.00
Installation,Testing and Commissioning of copper refrigerant piping of various sizes as given below. The rate shall include Copper pipe and insulation with 13 mm Thick Nitrile rubber tube and necessary Installation accessories such as supports and clamps. The sizes given shall be verified by Supplier for adequacy and size based on manufacturer standards.
44 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 200.00 1 Rmt 550.00 110000.00
Supply of CPVC drain piping 40mm dia with suitable supports as required and insulation of following sizes
45 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 200.00 1 Rmt 250.00 50000.00
Installation of CPVC drain piping 40mm dia with suitable supports as required and insulation of following sizes
46 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 50.00 1 Rmt 450.00 22500.00
Supply of CPVC drain piping 32mm dia with suitable supports as required and insulation of following sizes
47 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 50.00 1 Rmt 250.00 12500.00
Installation of CPVC drain piping 32mm dia with suitable supports as required and insulation of following sizes
48 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 220.00 1 Kg 1200.00 264000.00
Supply testing and commissioning of initial Charge of refrigerant gas etc., complete for finished item of work.
49 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 220.00 1 Kg 200.00 44000.00
Installation of testing and commissioning of initial Charge of refrigerant gas etc., complete for finished item of work.
50 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 20.00 Each 5500.00 110000.00
Installation of Nitrogen pressure testing and commissioing of the system
51 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 480.00 Each 750.00 360000.00
Supply, fabrication, testing of following sizes of Rectangular duct with TDS flange. Galvanized sheet metal ducting GI supports, angle iron flanges for all sizes of ducts, neoprene gaskets for all transverse joints, splitter dampers, tees, reducers, elbows etc., The frame shall slide over the duct ends to form flange connection. The flange connection shall be supplied with airtight seals. Ducts shall be suitably reinforced using diagonal bends, distance pieces, etc. A permanent non-etching, silicone free elastic sealing material shall be used 24 G, 0.63 mm thick
52 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 480.00 1 Sqm 250.00 120000.00
Installation of Rectangular duct with TDS flange. Galvanized sheet metal ducting GI supports, angle iron flanges for all sizes of ducts, neoprene gaskets for all transverse joints, splitter dampers, tees, reducers, elbows etc., The frame shall slide over the duct ends to form flange connection. The flange connection shall be supplied with airtight seals. Ducts shall be suitably reinforced using diagonal bends, distance pieces, etc. A permanent non-etching, silicone free elastic sealing material shall be used 24 G, 0.63 mm thick
53 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 225.00 1 Sqm 850.00 191250.00
Supply, fabrication, testing of following sizes of Rectangular duct with TDS flange. Galvanized sheet metal ducting GI supports, angle iron flanges for all sizes of ducts, neoprene gaskets for all transverse joints, splitter dampers, tees, reducers, elbows etc., The frame shall slide over the duct ends to form flange connection. The flange connection shall be supplied with airtight seals. Ducts shall be suitably reinforced using diagonal bends, distance pieces, etc. A permanent non-etching, silicone free elastic sealing material shall be used 22 G, 0.80 mm thick
54 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 225.00 1 Sqm 250.00 56250.00
Installation of Rectangular duct with TDS flange. Galvanized sheet metal ducting GI supports, angle iron flanges for all sizes of ducts, neoprene gaskets for all transverse joints, splitter dampers, tees, reducers, elbows etc., The frame shall slide over the duct ends to form flange connection. The flange connection shall be supplied with airtight seals. Ducts shall be suitably reinforced using diagonal bends, distance pieces, etc. A permanent non-etching, silicone free elastic sealing material shall be used 22 G, 0.80 mm thick
55 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 10.00 Each 3500.00 35000.00
Supply, fabrication, testing of following sizes of Rectangular duct with TDS flange. Galvanized sheet metal ducting GI supports, angle iron flanges for all sizes of ducts, neoprene gaskets for all transverse joints, splitter dampers, tees, reducers, elbows etc., The frame shall slide over the duct ends to form flange connection. The flange connection shall be supplied with airtight seals. Ducts shall be suitably reinforced using diagonal bends, distance pieces, etc. A permanent non-etching, silicone free elastic sealing material shall be used Canvas connections
56 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 10.00 Each 300.00 3000.00
Installation of Rectangular duct with TDS flange. Galvanized sheet metal ducting GI supports, angle iron flanges for all sizes of ducts, neoprene gaskets for all transverse joints, splitter dampers, tees, reducers, elbows etc., The frame shall slide over the duct ends to form flange connection. The flange connection shall be supplied with airtight seals. Ducts shall be suitably reinforced using diagonal bends, distance pieces, etc. A permanent non-etching, silicone free elastic sealing material shall be used Canvas connections
57 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 110.00 Each 8500.00 935000.00
Supply of removable core, heavy gauge, powder coated aluminum Supply Air Ceiling Jet nozzle etc., complete for finished item of work.
58 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 110.00 Each 750.00 82500.00
Installation of removable core, heavy gauge, powder coated aluminum Supply Air Ceiling Jet nozzle etc., complete for finished item of work.
59 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 8.00 1 Sqm 8800.00 70400.00
Supply of removable core, heavy gauge, powder coated aluminum Supply Air grill with volume control damper.
60 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 8.00 1 Sqm 750.00 6000.00
Installation of removable core, heavy gauge, powder coated aluminum Supply Air grill with volume control damper.
61 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 8.00 1 Sqm 8300.00 66400.00
Supply of removable core, heavy gauge, powder coated aluminum Return Air grill without volume control damper.
62 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 8.00 1 Sqm 500.00 4000.00
Installation of removable core, heavy gauge, powder coated aluminum Return Air grill without volume control damper.
63 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 12.00 1 Sqm 8900.00 106800.00
Supply, testing and commissioning of zero leak proof volume control dampers of GI sheet, box type to be provided in ducts complete with suitable links, levers and quadrants for manual control of air volume and air balancing
64 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 12.00 1 Sqm 1000.00 12000.00
Installation, testing and commissioning of zero leak proof volume control dampers of GI sheet, box type to be provided in ducts complete with suitable links, levers and quadrants for manual control of air volume and air balancing
65 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 10.00 1 Sqms 9500.00 95000.00
Supply of fusible link type fire damper of 16g GI casing & blades construction and fire rated for 90 minutes as per UL-555.
66 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 10.00 1 Sqms 1500.00 15000.00
Installation of fusible link type fire damper of 16g GI casing & blades construction and fire rated for 90 minutes as per UL-555.
67 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 830.00 1 Sqms 750.00 622500.00
Supply of Thermal for the supply air duct with 13 mm thick Nitrile rubber etc., complete for finished item of work.
68 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 830.00 1 Sqms 250.00 207500.00
Installation of Thermal for the supply air duct with 13 mm thick Nitrile rubber etc., complete for finished item of work.
69 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 1.00 1 Sqms 75000.00 75000.00
Transportation, lofting, shifting charges etc., complete for finished item of work.
70 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 1.00 1 Sqms 75000.00 75000.00
Installation of Transportation, lofting, shifting charges etc., complete for finished item of work.
71 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 12.00 Each 59600.00 715200.00
Air Cooling in Banjara Bhavan Supply of Inverter Model Cool Type split AC unit with high wall mounted Single Split Indoor unit and outdoor condencing unit Hermetically sealed compressor suitable for opration on 230V, 50Hz, 1 Phase AC Supply capable of performing Heat cool dehumidifying air curculating and filtering with cooling and condensing units with 3.5 mts of copper piping, insulation kit and 4mts of 4 core copper flexible chord (Voltage range 160-264 volts) and cordless remote control 1.8 TR 4 Star capable of delivering 21600 BTU/hr and above with operating on refrigerant R-32/R-410 Makes : O General/Daikin/Toshibha
72 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 12.00 Each 1530.00 18360.00
Installation of Split Air Conditioners etc., complete for finished item of work.
73 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 12.00 Each 2880.00 34560.00
Supply of 5.0 KVA Stablizer etc., complete for finished item of work.
74 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 12.00 Each 59600.00 715200.00
Air Cooling in Kumaram Bheem Bhavan Supply of Inverter Model Cool Type split AC unit with high wall mounted Single Split Indoor unit and outdoor condencing unit Hermetically sealed compressor suitable for opration on 230V, 50Hz, 1 Phase AC Supply capable of performing Heat cool dehumidifying air curculating and filtering with cooling and condensing units with 3.5 mts of copper piping, insulation kit and 4mts of 4 core copper flexible chord (Voltage range 160-264 volts) and cordless remote control 1.8 TR 4 Star capable of delivering 21600 BTU/hr and above with operating on refrigerant R-32/R-410 Makes : O General/Daikin/Toshibha
75 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 12.00 Each 1530.00 18360.00
Installation of Split Air Conditioners etc., complete for finished item of work.
76 AC DUCTS AND AIR COLLING As directed by the Engineer-in-charge 12.00 Each 2880.00 34560.00
Supply of 5.0 KVA Stablizer etc., complete for finished item of work.