Supply Of Thermal And Rac Lab Equipment frost free 165 ltr.domestic refrigerator full specification as per annexure ‘h’, water cooler full specification as per annexure ‘h’, window type air-conditioner 1.5 ton full specification as per annexure ‘h’, split type air-conditioner 1.5 ton full specification as per annexure ‘h’, refrigeration test rig. full specification as per annexure ‘h’, air conditioning test rig. full specification as per annexure ‘h’, vacuum pump full specification as per annexure ‘h’, models of compressor cut section working models of following actual compressors (1.5 ton), (mounted on wooden base) reciprocating open type full specification as per annexure ‘h’, models of compressorcut section working models of following actual compressors (1.5 ton), (mounted on wooden base) reciprocating hermetically sealed full specification as per annexure ‘h’, models of compressor cut section working models of following actual compressors (1.5 ton), (mounted on wooden base) rotary typefull specification as per annexure ‘h’, illustrative, detailed, cut section models of actual components (mounted on wooden base) automatic expansion valve ¼ full specification as per annexure ‘h’, illustrative, detailed, cut section models of actual components, (mounted on wooden base) thermostatic expansion valve ¼, full specification as per annexure ‘h’, tools & accessories for refrigeration lab, full specification as per annexure ‘h’, gas charging unit with, full specification as per annexure ‘h’, soldering and brazing complete units, full specification as per annexure ‘h’, ice plant tutor, full specification as per annexure ‘h’, cut section model of filter drier mounted on iron frame, full specification as per annexure ‘h’, model of compressor relay mounted on iron frame, full specification as per annexure ‘h’, sling psychrometer, full specification as per annexure ‘h’, digital hygrometer thermometer humidity meter with lcd, display, full specification as per annexure ‘h’, thermal lab illustrative detailed cut section models of, iron/steel following.:, (approx. size - length x width x height) ( in inches), cochran boiler (10 x 10 x 30), full specification as per annexure ‘h’, illustrative detailed cut section models of iron/steel, following.:(approx. size - length x width x height) ( in inches), babcock-will cox boiler (40 x10 x 24), full specification as per annexure ‘h’, illustrative detailed cut section models of iron/steel, following.:(approx. size - length x width x height) ( in inches), lancashire boiler (45 x 12 x 10), full specification as per annexure ‘h’, illustrative detailed cut section models of iron/steel, following.:(approx. size - length x width x height) ( in inches), lamont boiler (12 x 12 x 18), full specification as per annexure ‘h’, illustrative detailed cut section models of iron/steel, following.:(approx. size - length x width x height) ( in inches), benson boiler (12 x 12 x 18), full specification as per annexure ‘h’, illustrative detailed cut section models of iron/steel, following.:(approx. size - length x width x height) ( in inches), schmiedt hmtmann boiler(12 x 12 x 18), full specification as per annexure ‘h’, illustrative detailed cut section models of iron/steel, following.:(approx. size - length x width x height) ( in inches), economizer (10 x 8 x 18), full specification as per annexure ‘h’, illustrative detailed cut section models of iron/steel following.:(approx. size - length x width x height) ( in inches) air preheater (10 x 8 x18full specification as per annexure ‘h’, illustrative detailed cut section models of iron/steel following.:(approx. size - length x width x height) ( in inches) super heater (10 x 8 x18) full specification as per annexure ‘h’, working model of parsons reaction steam turbine (dia 6) full specification as per annexure ‘h’, illustrative detailed cut section models of cooling tower of iron/steel following.:-natural draught cooling tower (12x12x18)inch full specification as per annexure ‘h’, illustrative detailed cut section models of cooling tower of iron/steel following.:forced draught cooling tower (12x12x18)inch full specification as per annexure ‘h’, cut section models(metallic) mounted on suitable wooden framesteam stop valve full specification as per annexure ‘h’, cut section models(metallic) mounted on suitable wooden frame water level indicator full specification as per annexure ‘h’, cut section models(metallic) mounted on suitable wooden frame-spring loaded safety vale full specification as per annexure ‘h’, cut section models(metallic) mounted on suitable wooden framefeed check valve full specification as per annexure ‘h’, cut section models(metallic) mounted on suitable wooden framemechanical type pressure gauge full specification as per annexure ‘h’, cut section models(metallic) mounted on suitable wooden framedead weight safety valve full specification as per annexure ‘h’, cut section models(metallic) mounted on suitable wooden framesurface condenser full specification as per annexure ‘h’, cut section models(metallic) mounted on suitable wooden frame-jet condenser full specification as per annexure ‘h’, cut section models(metallic) mounted on suitable wooden frameedwards air pump (wet type) etc