| 1 | 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. | item 1 | 18.5 | Cum |
|---|
| 2 | 2 | Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth upto 1.5 metre). | item 2 | 5.05 | Cum |
|---|
| 3 | 3 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. | item 3 | 0.84 | Cum |
|---|
| 4 | 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone\naggregate 40 mm nominal size) | item 4 | 0.84 | Cum |
|---|
| 5 | 5 | Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases for columns | item 5 | 4.4 | sqm |
|---|
| 6 | 6 | Centering and shuttering including strutting, propping etc. and removal of form for :Wall | item 6 | 24.96 | sqm |
|---|
| 7 | 7 | Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers | item 7 | 7.92 | sqm |
|---|
| 8 | 8 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.All works upto plinth level | item 8 | 5.52 | Cum |
|---|
| 9 | 9 | Extra for providing richer mixes at all floor levels.Providing M-30 grade concrete instead of M-25 grade BMC/ RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum) | item 9 | 5.52 | Cum |
|---|
| 10 | 10 | Extra for all concrete works above plinth level upto floor V level | item 10 | 2.99 | Cum |
|---|
| 11 | 11 | Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more | item 11 | 851.08 | Kg |
|---|
| 12 | 12 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. | item 12 | 4246.1 | Kg |
|---|
| 13 | 13 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade Area of slab over 0.50 sqm | item 13 | 22.1 | Sqm |
|---|
| 14 | 14 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc.\ncomplete as per design approved by Engineer-in-Charge.Granite work | item 14 | 35 | M |
|---|
| 15 | 15 | Brick work with clay flyash F.P.S. (non modular) brick of class designation 7.5 in superstructure above plinth level up to floor five level\nin :Cement mortar 1:6 (1 cement : 6 coarse sand) | item 15 | 5.66 | Cum |
|---|
| 16 | 16 | Providing and fixing roofing consist of 0.8 mm thick galvanized steel deck sheet confirming to IS 277:1992 used as permanent shuttering over which MS wire mesh 3mm laid at 100x100 mm grid including edge trim covered with concrete. This metal deck will be supported on structural steel beam with shear studs. (Structural steel like Beam, column, joists etc. & concrete of different grade as per design will be paid separately). | item 16 | 13.86 | Sqm |
|---|
| 17 | 17 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design\nmix) | item 17 | 1 | Cum |
|---|
| 18 | 18 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material\nwithin 50 metres lead as per direction of Engineer-in-charge.In cement mortar | item 18 | 3.29 | Cum |
|---|
| 19 | 19 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand) | item 19 | 35.96 | Sqm |
|---|
| 20 | 20 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand) | item 20 | 35.96 | Sqm |
|---|
| 21 | 21 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. | item 21 | 35.96 | Sqm |
|---|
| 22 | 22 | Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.Two coats | item 22 | 71.92 | Sqm |
|---|
| 23 | 23 | Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of :\n(i) Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints\nsealed and grouted with cement slurry mixed with water proofing compound.\n(ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions.\n(iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the2nd layer. Using rough kota stone. | item 23 | 8.41 | Sqm |
|---|
| 24 | 24 | Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with\ncement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by\nEngineer-in-charge : Using rough Kota stone | item 24 | 25.52 | Sqm |
|---|
| 25 | 25 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.\nwith charcoal/ coke and salt as required. | item 25 | 1 | No |
|---|
| 26 | 26 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. | item 26 | 30 | M |
|---|
| 27 | 27 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, nterconnections, powder painted including\nearthing etc. as required. (But without MCB/RCCB/Isolator)6 way , Double door | item 27 | 1 | NO |
|---|
| 28 | 28 | Supplying, installation, testing and commissioning of following LED fitting (luminaries) down lighters in round/ square shape complete with electronic driver heat sink capacitor and all other accessories on surface/ in false ceiling etc. as required and furnishing 2 Yrs Guarantee certificate from manufacturer.10 Watt | item 28 | 2 | NO |
|---|
| 29 | 29 | Supplying and laying of one number PVC insulated and PVC sheathed / XLPE power cable copper conductor of 1.1 KV grade,16 sq. mm, 4.0 core direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. | item 29 | 50 | M |
|---|
| 30 | 30 | Wiring for lighting control point in surface PVC conduit of 20 mm using 1.5 sq. mm FRLS PVC insulated copper conductor in order to feed power to the bulk head lights at various locations of the shaft. | item 30 | 4 | NO |
|---|
| 31 | 31 | Suppy, installation, testing & commissitioning and putting into operation and final testing of automatic lift complete with ARD and all standard equipments, accessories and control equipments as per manufacturer's design and as per CPWD specification (Part III LIFTS) 1981and fulfilling following requirments on turn key basis.\nTYPE : PASSENGER AUTO LIFT ( 8Passengers) \nGEARLESS MACHINE ROOMLESS\nLOAD & SPEED : About 544 Kg @1 M/SEC\nCONTROL : Micro processor Based V.V.V.F.ARD System\nPOWER SUPPLY : 415 Volts, 3 Phase, 50 Cycles, Alternating Current\nTRAVEL : G+3 About 12.0 Meters\nSTOPS & OPENINGS : 4 Stops 4 Openings ( All Openings on the same side )\nMACHINE : DIRECTLY PLACED ABOVE HOIST WAY\nOPERATION : DOWN COLLECTIVE WITH ON/OFF SWITCH\nHOIST WAY REQUIRED: About 1750 MM WIDE X 1720 MM DEEP Finished Dimensions\nAVAILABLE CAR SIZE: As per our GA ( General Arrangement ) Approved\nCAR ENCLOSURE : SS CABIN Finish\nHOISTWAY ENTRANCES : Protected by CENTER OPENING PRECOATEDLAMINATE\n Clear opening about 800 MM WIDE X 2000 MM HIGH\nDOOR OPERATION : Power Operated Automatic.\nCAR ENTRANCE : Protected by CENTER OPENING PRECOATEDLAMINATE with Infrared Curtain\n Clear opening about 800 MM WIDE X 2000 MM HIGH\n\n | item 31 | 1 | NO |
|---|