| 1 | 1 | For Lift C | BI01010001010000000000000515BI0100001112 | | |
|---|
| 2 | 1.01 | SITC of Electric Traction Passenger Lift with • Rated capacity :- 8 Passenger/544Kg • Floors :- G+1 floor (2Stops/2 Landings) • Travel :- 3 to 4.2 mtrs • Location of Lift Machine:- MRL • Rated speed :- 1.0mps VS • Doors type :- PO/TOPO Doors with frame having clear opening of 800 mm wide x 2000 mm high made from SS 304 grade sheet of 1.5mm, thick in hairline finish ( mat finish ) for car and all landing doors with SS door architraves/frames • Lift car enclosure made from SS 304 grade sheet of 1.5mm, thick with hairline finish ( mat finish) with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. • COP with SS face plate having metallic push buttons with Braille Code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with/without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, & FCC/ground floor • Clear Car size of ......mm wide x ......mm deep x ......mm high• LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille Code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings • Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port, control panel duly wired with proper size & strength copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class • ARD complete with necessary SMF VRLA batteries • Fireman controller having fireman switch at fire Landing, • CCTV surveillance system comprises of 2nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for 60 days with 18\" FHD TV monitor, to be kept in FCC as directed by Engineer In Charge. • Lift Machine of Gearless PMSM of suitable kW with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength • Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary support arrangement, MS pit ladder etc. erected with necessary steel work • Minor civil work for alteration if any and erection of door frames and accessories, erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails fixing of girders for mounting lift machine etc. complete as per specification no. LFT. • Lift shaft available having clear size of ......mm wide x ......mm deep. ......mm Pit depth, ………mm Overhead. (DSR 18-19 ITEM NO 17-1-3 PG NO-252) (as per site condition) \n\n\n\n | BI01010001010000000000000515BI0100001113 | 1 | Nos |
|---|
| 3 | 1.02 | For Lift having 800mm wide x 2000mm high clear entrance in\n1.5mm thick SS 304 grade landing door [Two panel], this includes all\nnecessary accessories like LOP's with UP/DN buttons-arrowsindicators,\nextension of guide rails, shaft wiring with trunking,\ntraveling cables, main hoisting ropes/belts, & OSG rope landing\ndoors with all accessories etc. necessary for the normal safe\nfunctioning of lift installation complete (ADD ON -NOTE NO-2 PG NO-272) | BI01010001010000000000000515BI0100001114 | 4 | Nos |
|---|
| 4 | 2 | SITC of Electric Traction Passenger Lift with • Rated capacity :- 13 Passenger/884Kg • Floors :- G+1 floor (2Stops/2 Landings)\n• Travel :- 3 to 4.2 mtrs. • Location of Lift Machine:- MRL • Rated speed :- 1.0mps VS • Doors type :- COPO/TOPO Doors with frame having clear opening of 900/1000 mm wide x 2000 mm high made from SS 304 grade sheet of 1.5mm, thick in hairline finish for car and all landing doors with SS door architraves/ frames • Lift car enclosure made from SS 304 grade sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring,\nhandrails, mirror, emergency light etc.• COP with SS face plate having metallic push buttons with Braille Code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with/without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, FCC/ground floor • Clear Car size of ......mm wide x ......mm deep x ......mm high • LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille Code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings • Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port, control panel duly wired with proper size & strength copper wire for power & control circuit, with provision for addition of floor /control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class • ARD complete with necessary SMF VRLA batteries • Fireman controller having fireman switch at fire Landing, • CCTV surveillance system comprises of 2nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in inside lift shaft top aimed on Lift machinery & controller with NVR kept in FCC with HDR data backup for 60 days with 18\" FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. • Lift Machine of Gearless PMSM of suitable kW with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft wallscomplete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength• Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work • Minor civil work for alteration if any and erection of door frames and accessories, erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails fixing of girders for mounting lift machine etc. complete as per specification no. LFT. • Lift shaft available having clear size of ......mm wide x ......mm deep, ......mm Pit depth, ………mm Overhead.(DSR 18-19 ITEM NO 17-1-5 PG NO-254)\n | BI01010001010000000000000515BI0100001118 | 2 | Nos |
|---|
| 5 | 2.01 | For Lift A having 900mm wide x 2000mm high clear entrance in\n1.5mm thick SS 304 grade landing door [Two panel], this includes all\nnecessary accessories like LOP's with UP/DN buttons-arrowsindicators,\nextension of guide rails, shaft wiring with trunking,\ntravelling cables, main hoisting ropes/belts, & OSG rope landing\ndoors with all accessories etc. necessary for the normal safe\nfunctioning of lift installation complete(ADD ON -NOTE NO-3 PG NO-272) | BI01010001010000000000000515BI0100001119 | 5 | Nos |
|---|
| 6 | 2.02 | For Lift B having 900mm wide x 2000mm high clear entrance in\n1.5mm thick SS 304 grade landing door [Two panel], this includes all\nnecessary accessories like LOP's with UP/DN buttons-arrowsindicators,\nextension of guide rails, shaft wiring with trunking,\ntravelling cables, main hoisting ropes/belts, & OSG rope landing\ndoors with all accessories etc. necessary for the normal safe\nfunctioning of lift installation complete(ADD ON -NOTE NO-3 PG NO-272) | BI01010001010000000000000515BI0100001120 | 5 | Nos |
|---|