Supply And Installation Of Customized Workbenches And Specialized Test Equipments Ducts And Hoods:-2 Ventilation Hood Assembly Lh And Rh 3 Fuel Ventilator Hood And Ducts Assembly 4 Fuel Test Stand Hood And Ducts Assembly 5 Customized Workbench With Hood And Ducts Assembly 6 Graymills Hood And Ducts Assembly 7 6U X 500 Depth Networking Rack Wall Mounted 8 9Ux500 Depth Networking Rack Wall Mounted 9 Cat-6 Utp Cable-305 Meters 10 Cat-6 I / O Boxes 11 Cat-6 Patch Cards-2 Meters 12 Patch Cable Ofc Sc-Lc Mm 3 Meters 13 Rack Fixing 14 Laying Of Utp Cable 15 Fiber Laying Per Meter 16 Liu Fixing 17 Hdpe Pipe Laying 18 Fixing Of I / O Boxes 19 1 Giga Lx Sm Sfp Module 20 Dc Voltmeter;Range:0-300V;Accuracy:1.5; Resolution:5V;Size:Terminal Side Circular Shape Of Dia 90Mm, Scale Side Square Shape Of Side 97Mm X 97Mm 21 Dc Voltmeter;Range:0-500V;Accuracy:1.5; Resolution:10V;Size:Terminal Side Square Shape Of Side 90Mm X 90Mm, Scale Side Square Shape Of Side 97Mm X 97Mm 22 Ac Micro Voltmeter;Range: 0-250 Μv N ( 500Hz ) ;Accuracy:1.0;Resolution: 10 Μv;Size: Terminal Side Square Shape Of Side 90Mm X 90Mm, Scale Side Square Shape Of Side 97Mm X 97Mm N 23 Ac Voltmeter;Range:0-3V ( 30-45-1000-10000Hz ) ; Accuracy:2.5;Resolution:0.1V;Size:Terminal Side Square Shape Of Side 90Mm X 90Mm, Scale Side Square Shape Of Side 97Mm X 97Mm 24 Ac Voltmeter;Range:0-3V;Accuracy:2.5;Resolution: 0.1V;Size:Terminal Side Circular Shape Of Dia 73Mm , Scale Side Square Shape Of Side 80Mm X 80Mm 25 Ac Voltmeter;Range:0-50V ( 30-45-1000-10000 Hz ) ;Accuracy:1.5;Resolution: 2V;Size: Terminal Side Square Shape Of Side 90Mm X 90Mm, Scale Side Square Shape Of Side 97Mm X 97Mm 26 Ac Voltmeter;Range: 0-50V;Accuracy:2.5; Resolution:2V;Size:Terminal Side Circular Shape Of Dia 73Mm, Scale Side Square Shape Of Side 80Mm X 80Mm 27 Ac Voltmeter;Range:0-50 V ( 400-500 Hz ) ;Accuracy: 2.5;Resolution: 2V;Size: Terminal Side Square Shape Of Side 90Mm X 90Mm, Scale Side Square Shape Of Side 97Mm X 97Mm 28 Ac Voltmeter;Range: 0-50 V ( 500Hz ) ;Accuracy:2.5; Resolution:2V;Size:Terminal Side Square Shape Of Side 90Mm X 90Mm, Scale Side Square Shape Of Side 97Mm X 97Mm 29 Ac Voltmeter;Range:0-50V;Accuracy: 2.5; Resolution:2V;Size:Terminal Side Square Shape Of Side 90Mm X 90Mm, Scale Side Square Shape Of Side 97Mm X 97Mm 30 Ac Voltmeter;Range: 0-150V;Accuracy:2.5; Resolution:5V;Size:Terminal Side Circular Shape Of Dia 73Mm, Scale Side Square Shape Of Side 80Mm X 80Mm 31 Ac Voltmeter;Range:0-150V ( 30-45-1000-10000 Hz ) ; Accuracy:2.5;Resolution:5V;Size:Terminal Side Square Shape Of Side 90Mm X 90Mm, Scale Side Square Shape Of Side 97Mm X 97Mm 32 Ac Voltmeter;Range:0-200V ( 500Hz ) ; Accuracy:1.0; Resolution:5V;Size:Terminal Side Square Shape Of Side 90Mm X 90Mm, Scale Side Square Shape Of Side 97Mm X 97Mm 33 Ac Voltmeter;Range:0-250V;Accuracy:2.5; Resolution:10V;Size:Terminal Side Circular Shape Of Dia 73Mm, Scale Side Square Shape Of Side 80Mm X 80Mm 34 Ac Voltmeter;Range: 0-250 V ( 30-45-1000-10000 Hz ) ;Accuracy:2.5;Resolution:10V;Size:Terminal Side Square Shape Of Side 90Mm X 90Mm, Scale Side Square Shape Of Side 97Mm X 97Mm 35 Ac Voltmeter;Range:0-500V ( 50Hz ) ;Accuracy: 2.5; Resolution:20V;Size: Terminal Side Square Shape Of Side 90Mm X 90Mm, Scale Side Square Shape Of Side 97Mm X 97Mm 36 Dc Micro Ammeter;Range: 0-100Μa;Accuracy:1.5; Resolution:2Μa;Size:Terminal Side Circular Shape Of Dia 73Mm, Scale Side Square Shape Of Side 80Mm X 80Mm 37 Micro Ammeter;Range:Dc-500-0-500 Μa;Accuracy: 1.5;Resolution:20Μa;Size:Terminal Side Circular Shape Of Dia 74Mm, Scale Side Square Shape Of Side 120Mm X 105Mm 38 Dc Ammeter;Range: 0-1A;Accuracy:1.5; Resolution:0.05A;Size:Terminal Side Circular Shape Of Dia 52Mm, Scale Side Square Shape Of Side 60Mm X 60Mm 39 Dc Ammeter;Range: 0-1A;Accuracy:2.5;Resolution: 0.05A;Size:Terminal Side Circular Shape Of Dia 73Mm, Scale Side Square Shape Of Side 80Mm X 80Mm 40 Dc Ammeter;Range:0-2A;Accuracy:1.5; Resolution:0.05A;Size: Terminal Side Circular Shape Of Dia 52Mm, Scale Side Square Shape Of Side 60Mm X 60Mm 41 Dc Ammeter;Range:0-2A;Accuracy:1.5; Resolution:0.05A;Size:Terminal Side Circular Shape Of Dia 73Mm, Scale Side Square Shape Of Side 80Mm X 80Mm 42 Dc Ammeter;Range:0-2 Amps;Accuracy:2.5 Resolution:0.05A;Size:Terminal Side Circular Shape Of Dia 52Mm, Scale Side Square Shape Of Side 60Mm X 60Mm 43 Dc Ammeter;Range:0-3A;Accuracy:1.5; Resolution:0.1A;Size:Terminal Side Circular Shape Of Dia 73Mm, Scale Side Square Shape Of Side 80Mm X 80Mm 44 Dc Ammeter;Range:0-3 Amps;Accuracy: 2.5 Resolution:0.1A;Size:Terminal Side Circular Shape Of Dia 52Mm, Scale Side Square Shape Of Side 60Mm X 60Mm 45 Dc Ammeter;Range: 0-3 Amps;Accuracy: 2.5; Resolution:0.1A;Size:Terminal Side Circular Shape Of Dia 73Mm, Scale Side Square Shape Of Side 80Mm X 80Mm 46 Dc Ammeter;Range:0-10A;Accuracy:1.5; Resolution:0.5A;Size:Terminal Side Circular Shape Of Dia 52Mm, Scale Side Square Shape Of Side 60Mm X 60Mm 47 Dc Ammeter;Range:0-12Amps;Accuracy:1.5 Resolution:0.2A;Size: Scale Side Rectangular Shape 85Mm X 50Mm 48 Dc Ammeter;Range:0-20A;Accuracy:1.5; Resolution:0.5A;Size:Terminal Side Circular Shape Of Dia 52Mm, Scale Side Square Shape Of Side 60Mm X 60Mm 49 Dc Ammeter;Range:0-20A;Accuracy: 2.5; Resolution:1A;Size:Terminal Side Circular Shape Of Dia 73Mm, Scale Side Square Shape Of Side 80Mm X 80Mm 50 Dc Ammeter;Range: 0-40A;Accuracy: 1.5; Resolution:1A;Size:Terminal Side Square Shape Of Side 90Mm X 90Mm, Scale Side Square Shape Of Side 97Mm X 97Mm 51 Dc Ammeter;Range:0-50A;Accuracy:1.5; Resolution:1A;Size:Terminal Side Circular Shape Of Dia 73Mm, Scale Side Square Shape Of Side 80Mm X 80Mm 52 Dc Ammeter;Range: 0-50 A;Accuracy: 1.5; Resolution: 2A;Size: Terminal Side Circular Shape Of Dia 73Mm, Scale Side Square Shape Of Side 8033Mm X 80Mm 53 Dc Ammeter;Range:0-50A;Accuracy:1.5; Resolution:2A;Size:Terminal Side Circular Shape Of Dia 90Mm , Scale Side Square Shape Of Side 97Mm X 97Mm 54 Dc Ammeter;Range: 0-100A;Accuracy:1.5; Resolution:2A;Size:Terminal Side Circular Shape Of Dia 73Mm, Scale Side Square Shape Of Side 80Mm X 80Mm 55 Dc Ammeter;Range:0-100A;Accuracy: 2.5; Resolution:5A;Size:Terminal Side Square Shape Of Side 90Mm X 90Mm Nscale Side Square Shape Of Side 97Mm X 97Mm N 56 Dc Ammeter;Range:0-150A;Accuracy:1.5 Resolution: 5A ;Size:Terminal Side Circular Shape Of Dia 73Mm, Scale Side Square Shape Of Side 80Mm X 80Mm 57 Dc Ammeter;Range:0-200A;Accuracy: 1.5; Resolution:5A;Size:Terminal Side Circular Shape Of Dia 73Mm, Scale Side Square Shape Of Side 80Mm X 80Mm 58 Dc Ammeter;Range: 0-200A;Accuracy:1.5; Resolution:5A;Size:Terminal Side Circular Shape Of Dia 73Mm, Scale Side Square Shape Of Side 85Mm X 85Mm 59 Dc Ammeter;Range:0-300A;Accuracy:1.5; Resolution: 10A;Size:Terminal Side Circular Shape Of Dia 73Mm, Scale Side Square Shape Of Side 80Mm X 80Mm 60 Dc Ammeter;Range: 0-300A;Accuracy:1.5; Resolution:10A;Size:Terminal Side Square Shape Of Side 90Mm X 90Mm, Scale Side Square Shape Of Side 97Mm X 97Mm 61 Dc Ammeter;Range:0-300Ma ;Accuracy:1.5; Resolution:10Ma;Size:Terminal Side Circular Shape Of Dia 73Mm, Scale Side Square Shape Of Side 80Mm X 80Mm 62 Ac Ammeter;Range:0-2 Amps ( 550 Hz ) ; Accuracy:2.5;Resolution:0.1A;Size:Terminal Side Circular Shape Of Dia 73Mm, Scale Side Square Shape Of Side 80Mm X 80Mm 63 Ac Ammeter;Range: 0-3 Amps ( 550 Hz ) ; Accuracy:2.5;Resolution: 0.1A;Size:Terminal Side Circular Shape Of Dia 73Mm, Scale Side Square Shape Of Side 80Mm X 80Mm N 64 Ac Ammeter;Range:0-5 A ( 500Hz ) ;Accuracy: 2.5; Resolution:0.5A;Size:Terminal Side Circular Shape Of Dia 73Mm, Scale Side Square Shape Of Side 80Mm X 80Mm N 65 Ac Ammeter;Range: 0-10Amps ( 550 Hz ) ; Accuracy:2.5;Resolution:0.2A;Size: Terminal Side Circular Shape Of Dia 73Mm, Scale Side Square Shape Of Side 80Mm X 80Mm N 66 Ac Ammeter;Range: 0-50Amps ( 550 Hz ) ; Accuracy:2.5;Resolution:2A;Size:Terminal Side Square Shape Of Side 90Mm X 90Mm, Scale Side Square Shape Of Side 97Mm X 97Mm N 67 Micro Ammeter;Range: 100-0-100Μa; Accuracy:1.5; Resolution:2Μa;Size: Scale Side Rectangular Shape Of 120Mm X 120Mm 68 Micro Ammeter;Range: 600-0-1600Μa; Accuracy: 1.5;Resolution: 20Μa;Size:Terminal Side Circular Shape Of Dia 73Mm, Scale Side Square Shape Of Side 80Mm X 80Mm N 69 Megger With Ohmic Value Measurement; Range:100V; Accuracy:1.0; Resolution:2V 70 Megger With Ohmic Value Measurement; Range:500V; Accuracy:1.0; Resolution:10V 71 Megger With Ohmic Value Measurement Range:1000V; Accuracy:1.0;Resolution:20V 72 Collar 70 / 852517.019.0106, Nnai ( V ) Sk 1322, Nai ( B ) 12059 73 Collar 45 / 59 ( Seathed ) 2517.019.0809, Nnai ( V ) 1627, Nai ( B ) 12141 74 Collar 20 / 322517.019.0810, Nai ( V ) 1256 75 Collar ( Oilseal 15X35x10 ) Part No 4 Fig 40 Album Of Drg. 2517.000.0000-05 76 Valve 2556.010.000 77 Valve Part No.42 78 Valve Part No.Ab32.010.030 79 Valve, Part No.Ab01.09.000-1 80 Valve, Part No.002.84.030