Provision Of Cooling Tower For Main Chiller And Icu Air Conditioner Plant , Ups System At Icu Complex , Cooling Tower For Ot And Dialysis Centre Ac Plant And Connected Works At Base Hospital Under Ge E/M Base Hospital Delhi Cantt-10, GE E/M BASE HOSP DELHI CANTT-Delhi

Military Engineer Services-MES has published Provision Of Cooling Tower For Main Chiller And Icu Air Conditioner Plant , Ups System At Icu Complex , Cooling Tower For Ot And Dialysis Centre Ac Plant And Connected Works At Base Hospital Under Ge E/M Base Hospital Delhi Cantt-10. Submission Date for this Tender is 24-12-2019. Cooling Tower Tenders in GE E/M BASE HOSP DELHI CANTT Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

22856690
Provision Of Cooling Tower For Main Chiller And Icu Air Conditioner Plant , Ups System At Icu Complex , Cooling Tower For Ot And Dialysis Centre Ac Plant And Connected Works At Base Hospital Under Ge E/M Base Hospital Delhi Cantt-10
Open Tender
Indian
Delhi
GE E/M BASE HOSP DELHI CANTT
24-12-2019

Tender Details

Provision Of Cooling Tower For Main Chiller And Icu Air Conditioner Plant , Ups System At Icu Complex , Cooling Tower For Ot And Dialysis Centre Ac Plant And Connected Works At Base Hospital Under Ge E/M Base Hospital Delhi Cantt-10

Key Value

Document Fees
INR 500 /-
EMD
INR 99800.0 /-
Tender Value
INR 49.90 Lakhs /-

BOQ Items

Name of Work: PROVN OF COOLING TOWER FOR MAIN CHILLER AND ICU AC PLANT, UPS SYSTEM AT ICU COMPLEX, COOLING TOWER FOR OT AND DIALYSIS CENTRE AC PLANT AND CONNECTED WORKS AT BASE HOSPITAL UNDER GE E/M BASE HOSPITAL DELHI CANTT-10
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Supply, installation, fixing, testing and commissioning induced draft type cooling tower of fibre glass reinforced plastic (FRP) casting rectangular or circular construction with minimum 130 TR capacity, complete with all accessories corrosion proof PVC fill and inlet louvers, drift, eliminators hot water distribution chamber and nozzles, basin fitting, fan totally enclosed weatherproof electric motor including pedestal supports and steel grillage and stays for necessary anchorage of cooling tower including RCC foundation as recommended by OEM of Cooling tower complete all as specified and directed. 2 Each
2 1.1 Note:- (i) Make of cooling tower :Delta Model No 5071, Series DFC-50 or equivalent model of Mihir/Advance/Paharpur/Polo.
3 1.2 (ii) The cooling tower shall be assembled and fitted in presence of company representative and shall be tested as per company specifications.
4 1.3 (iii) Any spares required for assembling the cooling tower like nuts, bolts, rivets, gaskets etc shall be provided by the contractor and rates of the same are included in quoted rate.
5 1.4 (iv) Rate quoted by the contractor shall be Inclusive of RCC foundation as per OEM recommendation complete all as specified and directed.
6 2 Supply, installation, fixing, testing and commissioning induced draft type cooling tower of fibre glass reinforced plastic (FRP) casting rectangular or circular construction with minimum 30 TR capacity complete with all accessories corrosion proof PVC fill and inlet louvers, drift, eliminators hot water distribution chamber and nozzles, basin fitting, fan totally enclosed weatherproof electric motor including pedestal supports, and steel grillage and stays for necessary anchorage of cooling tower including RCC foundation complete as recommended by OEM of Cooling tower complete all as specified and directed. 1 Each
7 2.1 Note:- (i) Make of cooling tower : Delta, Model No 5031, Series :- DFC-50 or equivalent model of Mihir/Advance/Paharpur/Polo.
8 2.2 (ii) The cooling tower shall be assembled and fitted in presence of company representative and shall be tested as per company specifications.
9 2.3 (iii) Any spares required for assembling the cooling tower like nuts, bolts, rivets, gaskets etc shall be provided by the contractor and rates of the same are included in quoted rate.
10 2.4 (iv) Rate quoted by the contractor shall be Inclusive of RCC foundation as per OEM recommendation complete all as specified and directed.
11 3 Supply, installation, fixing, testing and commissioning of induced draft type cooling tower of fibre glass reinforced plastic (FRP) casting rectangular or circular construction with minimum 180 TR capacity complete with all accessories corrosion proof PVC fill and inlet louvers, drift, eliminators hot water distribution chamber and nozzles, basin fitting, fan totally enclosed weatherproof electric motor including pedestal supports, and steel grillage and stays for necessary anchorage of cooling tower including RCC foundation complete as recommended by OEM of Cooling tower complete all as specified and directed. 1 Each
12 3.1 Note:- (i) Make of cooling tower : Delta, Model No 5081, Series :- DFC-50 or equivalent model of Mihir/Advance/Paharpur/Polo.
13 3.2 (ii) The cooling tower shall be assembled and fitted in presence of company representative and shall be tested as per company specifications.
14 3.3 (iii) Any spares required for assembling the cooling tower like nuts, bolts, rivets, gaskets etc shall be provided by the contractor and rates of the same are included in quoted rate.
15 3.4 (iv) Rate quoted by the contractor shall be Inclusive of RCC foundation as per OEM recommendation complete all as specified and directed.
16 4 Supply, installation, Testing and commissioning of MS 'C' class Condenser water piping of following size confirming to IS-1239 and IS- 3589 both revised till date as required and as specified and complete with bends, reducers, tees, supports flanges, gasket, nut bolts etc as required and painting with two coat of synthetic enamel paint over and including one coat red oxide primer complete all as specified and directed, (Make: Jindal/TATA/Prakash): -
17 4.1 (a) 80 mm internal dia 35 RM
18 4.2 (b) 100 mm internal dia 39 RM
19 5 Supply, fixing, Testing and commissioning butterfly valve of following size with cast iron body, seat of black nitric rubber, nylon coated S..G. Iron disc, PTFE coated SS ( AISI 410 ) shaft, with companion flanges, nuts, bolts, gaskets tec Complete as required. These valves shall confirm to BS:5155 MSS SP.67 & API. 6098 and shall be designed to fit without gaskets between mating and seal in both direction . The valves shall be of integral moulded design complete all as specified and directed, (Make: Zoloto/Kirloskar/Kartar): -
20 5.1 (a) Suitable for 80 mm internal dia pipe 16 Each
21 5.2 (b) Suitable for 100 mm internal dia pipe 14 Each
22 6 Supply, fixing, testing and commissioning of Pot strainer of following size having CI / MS body, bolted cover, flanged ends, basket of brass, Bronze/ SS wire mesh 24Gx 14 mesh for condenser water application with flanges, nuts bolts, gasket etc complete all as specified and directed.\nMake:- Kartar/Leader/BIR
23 6.1 (a) Suitable for 80 mm internal dia pipe 4 Each
24 6.2 (b) Suitable for 100 mm internal dia pipe 4 Each
25 7 M & L PCC ( 1:4:8) type D2 using 40mm graded stone aggregate as in foundation of stay assembly, pole, struts etc and similar work complete all as specified and directed. 3 Cum
26 8 M & L PCC ( 1:2:4) type B1 using 20mm graded stone aggregate as in pedestal of pole / struts including necessary form work and finishing exposed faces of concrete even & smooth without using extra cement complete all as specified and directed. 2 Cum
27 9 Supply, erection, testing & commissioning ductable type split air conditioner Air-cooled type Air conditioner 5.5 TR cooling capacity to achieve 23+2°C Room temperature at 45 °C Ambient Temperature, corrosion proof of Make carrier, Model NO :- 40LC-007GA for indoor and 38LH-066GSB for outdoor unit, complete with connected copper pipe line of size recommended by OEM and up to and including 15 Mtr length (two run of suction and discharge pipe shall be considered as one length) with PVC drain pipe of size recommended by OEM up to length of 10 Mtr, with remote control microcontroller LED display to operate two machine with charged Gas of R410A, Controller and power panel, Control and power cabling between indoor to outdoor unit as recommended by manufacture, etc. The unit should built in with controller specially designed for refrigeration applications, Controls compressor cut off and temperature and status monitoring etc. with following Technical specifications complete all as specified and directed: -\n 3 Each Set
28 9.1 TECHNICAL SPECIFICATION OF INDOOR UNIT:\nModel of Indoor Unit :- 40LC-007GA of Make Carrier or Equivalent Model of Daiken/Blue Star/ Voltas\npower Supply :- 230/1/50\nAir flow :- 2200 CFM\nNominal air quantity: 1.03 Cubic meter / Sec\nNumber of circuit :- 01\nOver all dimensions :- 750 x 1250 x 345 mm ( (W X D X H)\nDry Weight :- 60 KG\n
29 9.2 TECHNICAL SPECIFICATION OF OUTDOOR UNIT:\nModel of Outdoor unit :- 38LH-066GSB of Make Carrier or Equivalent Model of Daiken/Blue Star/ Voltas\nCompressor type :- Scroll\nPower supply :- 415/3/50\nCompressor Quantity :- 1\nOver all Dimensions :- 410 x 1040 x 875 mm ( W x D x H)\nDry Weight :- 112 KG\n
30 10 Supply, erection, testing & commissioning of ductable type Air-cooled Air conditioner 4 TR cooling capacity to achieve 23+2°C Room temperature at 45 °C Ambient Temperature, corrosion proof of Make carrier, Model NO :- 40LC-005GA for indoor and 51MSG-048GS8 for outdoor unit, complete with connected copper pipe line of size recommended by OEM and up to and including 15 Mtr length (Two run of suction and discharge pipe shall be considered as one length) with PVC drain pipe of size recommended by OEM up to length of 10 Mtr, with remote control microcontroller LED display for operate two machine with charged Gas of R410A, Controller and power panel, Control and power cabling between indoor to outdoor unit as recommended by manufacture. The unit should built in with controller specially designed for refrigeration applications , Controls compressor cut off and temperature and status monitoring etc, with following Technical specifications complete all as specified and directed: -\n\n 3 Each Set
31 10.1 TECHNICAL SPECIFICATION OF INDOOR UNIT:\nModel of Indoor Unit :- 40LC-005GA of Make Carrier or Equivalent Model of Daiken/Blue Star/ Voltas\npower Supply :- 230/1/50\nAir flow :- 1600 CFM\nNominal air quantity: 0.75 Cubic meter / Sec\nNumber of circuit :- 01\nOver all dimensions :- 725 x 1205 x 345 mm ( (W X D X H)\nDry Weight :- 62 KG\n
32 10.2 TECHNICAL SPECIFICATION OF OUTDOOR UNIT:\nModel of Outdoor unit :- 51MSG-048GSB of Make Carrier or Equivalent Model of Daiken/Blue Star/ Voltas\nCompressor type :- Scroll\nPower supply :- 415/3/50\nCompressor Quantity :- 1\nOver all Dimensions :- 435 x 1030 x 695 mm ( W x D x H)\nDry Weight :- 82 KG\n
33 11 Supply, erection, testing & commissioning of ductable type Air-cooled type Air conditioner 8.5 TR cooling capacity to achieve 23+2°C Room temperature at 45 °C Ambient Temperature corrosion proof of Make carrier, Model NO :- 40LC-010GA for indoor and 38LH-102GSB for outdoor unit complete with connected copper pipe line of size recommended by OEM and up to and including 15 Mtr length (two run of suction and discharge pipe shall be considered as one length) with PVC drain pipe of size recommended by OEM up to length of 10 Mtr, with remote control microcontroller LED display for operate two machine with charged Gas of R410A, Controller and power panel, Control and power cabling between indoor to outdoor unit as recommended by manufacture etc with following Technical specifications complete all as specified and directed. The unit should built in with controller specially designed for refrigeration applications, Controls compressor cut off and temperature and status monitoring etc: -\n\n 2 Each Set
34 11.1 TECHNICAL SPECIFICATION OF INDOOR UNIT:\nModel of Indoor Unit :- 40LC-010GA of Make Carrier or Equivalent Model of Daiken/Blue Star/ Voltas\npower Supply :- 230/1/50\nAir flow :- 3400 CFM\nNominal air quantity: 1.60 Cubic meter / Sec\nNumber of circuit :- 01\nOver all dimensions :- 700 x 1646 x 460 mm ( (W X D X H)\nDry Weight :- 91 KG\n
35 11.2 TECHNICAL SPECIFICATION OF OUTDOOR UNIT:\nModel of Outdoor unit :- 38LH-102GSB of Make Carrier or Equivalent Model of Daiken/Blue Star/ Voltas\nCompressor type :- Scroll\nPower supply :- 415/3/50\nCompressor Quantity :- 1\nOver all Dimensions :- 610 x 982 x 1100 mm ( W x D x H)\nDry Weight :- 135 KG\n
36 12 Duct Work Section: S&F site fabricated GSS Sheet metal of following thickness, rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter damper vanes, hangars, supports as per approved drawings and specifications complete all as specified and directed. Make of Sheet : TATA/SAIL/ RINL/ TISCO : -
37 12.1 0.63 mm thick sheet (24 gauge) 68 Sqm
38 12.2 0.80 mm thick sheet(22 gauge) 82 Sqm
39 13 Supply, Installation, Testing and commissioning grills with powder coating having aluminium construction / air diffuser with powder coating having aluminium construction with MS volume control damper backed with enamel paint (colour shall be as per the architect requirement) complete all as specified and as directed. 4 Sqm
40 14 Supply, installation, testing and balancing square shape supply air diffusers with removable core and antismudge ring and volume control dampers powder coated extruded aluminium construction complete all as specified and as directed. 7 Sqm
41 15 Supply installation testing and balancing of square shape return air diffusers with removable core and antismudge ring and without control dampers with powder coated extruded aluminium construction complete all as specified and as directed. 7 Sqm
42 16 Supply and fixing duct insulation with 25 mm thick nitrile with Aluminium foil. The thermal insulation shall be 25 mm thick non -fibrous, fire retardant, closed cell, tri-dimensional chemically cross llinked polyethylene foam, conforms to class 'O' for fire propagation and class 1 for surface spread of flame &factory laminated aluminium foil complete all as required, as specified and as directed.\nMake:- Aerofoum/Armaflex 122 Sqm
43 17 S&F with anchor fastener angle iron, MS flat to support duct with angle iron, flats, nut bolt washers etc. Necessary welding work involved is also deemed to be included in quoted rate including cutting, fabrication, welding of angle iron / MS Flat, repair to RCC wall, cost of anchor fastener etc complete all as specified and as directed. 140 Kg
44 18 Supply, laying, jointing and testing under ground electric cable of following sizes, XLPE insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor laid in trenches/ duct/ pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed, (Make: Polycab/Havells/Finolex): -: -
45 18.1 4 Core 10 Sqmm 40 RM
46 18.2 4 Core 16 Sqmm 40 RM
47 19 Supply, installation, testing and commissioning outdoor type feeder pillar Box made out of 3.15 mm thick CRCA sheet, 415 Volt, 3 phase, 50 HZ supply factory made & MS angle section 40 x40x 5mm frame with front and back openable, double door with provision of locking arrangement, dust & vermin proof, gasket, TPN bus bar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof duly spray painted inside and outside of panel with two coat of synthetic enamel grey paint over and including one coat of red oxide primer and Consisting of the following equipments complete all as specified and as directed : -\n(i) MCCB , 4 Pole , 35 KA , 160 Amp - 01 No ( Incoming) MAKE : Legrand/L&T\n(ii) MCCB , 4 pole , 16 KA, 63 Amps, - 04 Nos (Outgoing) MAKE : Legrand/Havells/L&T\n(iii) Digital Voltmeter of size 96 x96 mm ( 0-500v) with built in selector switch MAKE : L&T/ Secure/Conserve\n(iv) Digital Ammeter of size 96 x96 mm ( 0-150A) with built in selector switch MAKE : L&T/ Secure/Conserve\n(v) Indication Lamp 22.5 mm dia LED type 240Volts AC to show three phase availability- 01 set MAKE : L&T/ Secure/Conserve\n(vi) Solid aluminium bus bar 600 Amp for 3 phase, 400 Amp for neutral\n(vii) PCC and block Masonry foundation work for grouting of panel complete all as specified and directed. (Make: BBN/Energy/Universal/Conelek): - 2 Each Job
48 20 S & F distribution board (DB), double door type made out of sheet metal enclosure (CRCA sheet) dust and vermin proof DB, TPN 8 way with 200 Amps rated copper bus bar, 415 Volts with in built MCCB 125 Amps, 10 KA, 01 No., earth bar IP 43 protection, flush to wall complete all as specified and directed. Make : Legrand/Siemens/ Schneider 2 Each
49 21 S & F distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 4 way with 200 Amps rated copper bus bar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, flush to wall complete all as specified and directed. Make : Legrand Model: 507610 or equivalent model of Siemens / Schneider (Acti-9). 6 Each
50 22 S & F MCB TPN 63 Amp complete all as specified and directed.\nMake - Havells/ Legrand/Crabtree 10 Each
51 23 M&L for sub main wiring with 4 runs of 16 Sqmm single core, FRLS PVC insulated & unsheathed cable 1100 Volts grade with multi stranded, copper conductor drawn through concealed conduit including PVC rigid conduit medium grade 50 mm dia as per IS and one run of 16 Sqmm size FRLS PVC insulated copper conductor complete all as specified and directed. (Note. Four run of 16.00 Sqmm cable and 16.00 Sqmm earth conductor shall be measured as one length) \nMake : Finloex/Havells/Polycab 41 RM
52 24 Supply and fixing citation DOL motor starter suitable for 3 phase, 415V, 7.5 HP rating induction motor, containing Electric over current protection relay range 8.9 to 13.5 Amp, 16 Amp rating contractor and back up protection HRC fuse of suitable rating etc complete all as specified and directed. Make: BCH Cat No.- NAKLEN or equivalent model of L&T/ SIEMENS /ABB 4 Each
53 25 Supply, laying, jointing and testing 3 Core, 95 Sqmm cable, XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured for Earth system., electric power cable heavy duty with standard aluminium conductor 11000 Volt grade complete all as specified and directed. \nMake : Finloex/Havells/Polycab 55 RM
54 26 Supply, fixing and installation 160 KVA, 11/0.433KV, AN, Oil Type Transformer with corrugated off circuit tap links of rating +5% to - 5% in the step of 2.5 % by means of hand operated off load tap changing gear 160 KVA capacity transformer copper wound, step down, outdoor type 11000/433 Volt (at no load) double wound oil immersed, naturally cooled with external cooling tubes core type delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector symbol Dy-II (vector group) with neutral brought on secondary side (LV side) and having tapping at /- -2.5%/ 5.0% and /-7.5% to be changed the maximum temperature rise should not exceed 45 degree centigrade in oil and 55 degree centigrade in HV/LV winding when measured by resistance method after continuous full load run in ambient temp of 40 degree centigrade and the transformer shall be comprised with the following standard fittings, including necessary foundation work with block masonry and PCC of size 5 ft x 5 ft x 4 ft ( LXBXH) complete all as specified and directed. (Make:- Crompton Greaves, India Transformer and Electricals Pvt Ltd, RTS Power corporation Ltd, Voltamp): - 1 Each Set
55 26.01 (i) Pressure Release Valve
56 26.02 (ii) Thermometer pocket on tank cover
57 26.03 (iii) Oil temperature indicator with 2 contacts alarm & trip
58 26.04 (iv) Rating plate with terminal marking
59 26.05 (v) Two earthing terminals on tank and cover to facilitate fixing of GI earth strip
60 26.06 (vi) Oil level gauge
61 26.07 (vii) Oil drain filter valve
62 26.08 (viii) Lifting lugs
63 26.09 (ix) Oil filter hole with cap/plug including connection complete
64 26.1 (x) Four plain solid cast steel detachable rollers
65 26.11 (xi) First fill of transformer oil confirming to relevant IS and testing up to 60 KV di-electric strength
66 27 Supply, installation, testing and commissioning of diesel Engine driven generating set of 62.5 KVA capacity 3 phase, 4 wire, 415 V, 1500 RPM AC power supply with power factor 0.8, coupled directly to alternator mounted on a common base plate complete with integral acoustic enclosures (should have salient features) modular bolted construction, & pure polyester based coating to ensure long life in all weather conditions & for outdoor application / installation, integrated design thereby facilitating / easy handling. The design of integral acoustic enclosure should be approved by National Physical laboratory as per central pollution control board (CPCB) latest regulation / norms with fuel tank, battery & standard accessories, tools & spares as provided by manufacturer the quoted rates inclusive of PCC work and block masonry and plaster works for foundation of DG set along with galvanise sheet shade fabricated with 80 mm hollow MS pipe line for column support and 40 mm hollow MS pipe for beam and truss in continues length of foundation covered with galvaniusm sheet complete all as specified and directed with following specifications, (Make of Engine:-Krilosker/Cummins/Greaves Ltd, \nMake of Alternator: CG/Stamford/Alstom/Bharat Bijlee/ GE/Kirloskar Electric) 1 Each Set
67 27.01 (A) ENGINE- Water cooled diesel engine of at 1500 RPM capacity to match the 62.5 KVA alternator under NTP conditions with provision of 10 % over load for 1 hour in every 12 hours running confirming to BS 5514/ IS 10001/ 10002. The Engine shall be consist of the following:-
68 27.02 (i) Fly wheel with starter ring
69 27.03 (ii) Flexible coupling with guard
70 27.04 (iii) Cooling fan
71 27.05 (iv) Radiator with guard and water pump engine mounted
72 27.06 (v) Dynamo of suitable capacity
73 27.07 (vi) Air cleaner heavy duty dry
74 27.08 (vii) Fuel injection pump
75 27.09 (viii) Radiator fan ( Blower type ) with guard
76 27.1 (ix) Mechanical governor
77 27.11 (x) Fuel filter (Mounted)
78 27.12 (xi) Lubricating oil filters ( mounted)
79 27.13 (xii) 12 v self regulating alternator belt driven by engine
80 27.14 (xiii) Exhaust silencer heavy duty residential type
81 27.15 (xiv) Corrosion resistor /scale inhibitor
82 27.16 (xv) Starter 12 V DC
83 27.17 (xvi) Lubricating oil cooler
84 27.18 (xvii) Lubricating oil pump (Gear type )
85 27.19 (xviii) Turbo charger
86 27.2 (xix) Exhaust piping shall be insulated with asbestos rope duly cladded with aluminium sheet.
87 27.21 (xx) Instrument panel complete with :-
88 27.22 (a) Auto manual Starting switch with key
89 27.23 (b) Lubricating oil temperature gauge
90 27.24 (c) Lubricating oil pressure gauge
91 27.25 (d) Water temperature gauge
92 27.26 (e) Battery charging ammeter
93 27.27 (f) Battery charging indicating lamp
94 27.28 (g) Hour meter with RPM indicator
95 27.29 (h) Safety control against high temperature of water.
96 27.3 (j) Safety control against low lubricating oil pressure .
97 27.31 (k) Over speed stop with double driven adopter .
98 27.32 (B) BRUSH LESS ALTERNATOR
99 27.33 (i) Alternator coupled to engine indigenous make through a flexible coupling mounted on sturdy steel fabricated base frame suitable for mounting on a permanent foundation brushless alternator shall be confirming to BS -2613 or relevant of IS-4722/ IS 13364
100 27.34 (ii) Type ;- Self excited self regulated with automatic voltage regulator .
101 27.35 (iii) Rating :- 62.5 KVA at 0.8 PF lagging 4 pole horizontal at NTP condition .
102 27.36 (iv) Speed;- 1500 RPM
103 27.37 (v) System :- 415 V +/- 2.5 % AC 3 phase 4 wire 50 Hz.
104 27.38 (vi) Connection :- 4 wire star connected .
105 27.39 (vii) Enclosure ;- Screen protected drip proof .
106 27.4 (viii) Ventilation :- Self ventilated.
107 27.41 (ix) Insulation :- Insulation class H
108 27.42 (C) CONTROL PANEL
109 27.43 The control panel with aluminium bas bar, bottom entry and exit of cable, current transformer, set of control fuses, Multifunctional Meter, it should display time and date, Volts, Frequency, Current, KW, KWH, PF, RPM, Cumulative Run Hours, Oil Pressure, Coolant Temp, Charging current (DC Amp Meter). Emergency off, factory made floor mounted, totally enclosed, epoxy powder coated suitable for 62.5 KVA DG Set including all necessary operating controlled devices as stated above and MCCBs as out going with protection fuse for panel instruments duly wired with flexible copper conductor cable and cable connection with lugs/thimbles complete as per latest IS/BS and all as specified and directed.
110 27.44 (D) ONE SET OF ACCESSORIES COMPRISING OF:-
111 27.45 (a) Fuel tank -one No. fabricated with 3 mm thick MS sheet with necessary mild steel structure for mounting the tank higher than the DG set) with piping. Capacity of tank shall be to hold diesel sufficient for 16 hours running at full load, with following features
112 27.46 (i) Level indicator.
113 27.47 (ii) drain plug .
114 27.48 (iii) MS class 'C' piping for inlet from pump to tank to engine.
115 27.49 (iv) Fuel strainer.
116 27.5 (v) Air vent.
117 27.51 (b) Fuel PUMP;-
118 27.52 Electrical operated fuel pump for filling diesel in the tank of adequate capacity with inlet connection to the tank with 5 meter flexible hose pipe heavy duty for suction of diesel from barrel.
119 27.53 (c) Sealed maintenance free Battery :-
120 27.54 Heavy duty battery two Nos 24 plates 12 V 180 AH (1 Nos) connected to the system fully charged including lead and battery terminal's complete. \n
121 27.55 (d) Base plate :- Fabricated out of MS channel's ISMC of suitable size suitable for fixing of DG set all specified by the manufacturer
122 27.56 (E) AMF PANEL:-
123 27.57 The AMF Panel suitable for 62.5 KVA DG Set factory made out of CRCA Steel 16 SWG Sheet floor mounted type and front operated type, totally enclosed dust, damp and vermin proof, all doors and joints will be suitable gasketed to form dust and vermin proof. The panel would be powder coated minimum thickness of 50 microns, stove enamelled paint finished after elaborate pre-treatment to form a long lasting characteristic. The control panel will be complete in all respect with fuses, wiring and labels etc, the following will be incorporated in the AMF Panel :- a) Multifunctional meter digital (Amp+Volt+PF+Hz+KW=KWH) -01 Nos \nb) Alternator voltage monitor-01 Nos \nc) Main voltage monitor - 01 Nos
124 27.58 d) Ammeter DG Analog - 01 Nos \ne) Voltmeter DG Analog -01 Nos\nf) Power fuse link -06 Nos\nh) Power fuse base -06 Nos\nj) Man power contactor - 3 pole - 01 Nos\nk) DG Power contactor-3 pole -01 Nos \nl) Indicator lamp -02 Nos
125 27.59 m) MCB (for control ckt) -10 Nos \nn) Auxiliary Contactor -02 Nos \no) Automatic battery 12 volt charge -01 Nos \np) Terminal O/L relay - 01 Nos \nq) Terminals (for control cable) - 06 Nos \n(r) One set of copper bus bar of suitable capacity.
126 28 Supply, installation, testing and commissioning of 30 KVA on line UPS with inbuilt isolation transformer and connected Battery Rack and link & Accessories including battery bank suitable for 15 Min back up with 2 Set of 34*12V/42AH Batteries with and including connected accessories as per OEM standards complete all as specified and directed. Make :- EMERSON, SCHINDER, SIEMENS.\nNote:- The detailed/Tech specification of UPS shall be as per PS. 1 Each Set
127 29 Supply, installation, commissioning and testing indoor type metal clad totally enclosed and fully interlocked draw out type vacuum circuit breaker 2 Nos incomer, 1 Nos Bus Coupler &1 Nos outgoing mechanical interlock between 2 incoming as per IEC 62271-100/200/IS 13118, 11 KV, 630 Amps 350 MVA, 18.4KA, single break trip free breaker with hand charged and motorized spring charged mechanism complete with self contained operated fully interlocked rack in and rack out mechanism, breaker is featured with mechanical ON and OFF indicator with hand trip device, spring release coil shunt trip coil and auxiliary switch of 4 NO + 4 NC with the following specifications. (a)Fully compartmentalised sheet enclosure floor mounting type with automatic safety shutters independent pressure discharge flaps along with one sets heat shrinkable PVC sleeved 800 amp aluminium bus bars ,foundation bolts etc, with provision for termination of 02 Nos, suitable for fixing of three core XLPE HT cable, Bus bar joints are enclosed by monoplast compound & HT tape along with following accessories in all VCBs :- Make of VCB :- Schneider, ABB, Siemens, CG\n(A) CT and PT Details :- (i) Three core ring/wound type CT, Ist core CL 1.0 for metering, 2nd core CL 1.0 for controlling & 3rd core CL 5P10 for protection, 15 VA burned, CT Ratio - 100/5, set of three. (ii) One No three phase PT with ratio 11000/V3, 100 VA/Phase, CL 1.0, OVF 1.9 for 30 sec for metering & protection backed by HT & LT fuses - Set of one No. 1 Each Set
128 29.1 (B) Breaker Panel Indication Lamps :-\n(i) Breaker ON/OFF/TRIP/TRIP CIRCUIT HEALTHY/SPRING CHARGE etc 05 Nos. \n(ii) R ph/Yph/B ph - 03 Nos \n(C) Switches and other accessories :- \n(i) DC ON/OFF switch - 01 No \n(ii) AC ON/OFF switch - 01 No \n(iii) Heater with heater switch & Thermostat - 01 No \n(iv) Cubical illumination lamp - 01 No \n(v) 15A, 230V, 3 pin plug & plug & socket and MCB -01 No. \n(vi) T-N-C switch - 01 No. \n(vii) Mech. ON/OFF push button - 01 No. \n(D) Meters and Transducers :- \n(i) Ammeter with selector switch(digital) - 01 No \n(ii) Voltmeter with selector switch(digital)- 01 No \n(iii) Trivector energy meter - 01 No. \n(E) Digital Relays :- (i) O/C & E/F elements-Micom p111 - 01 No \n(ii) Lockout relay type-86-VAJH13 - 01 No. \n
129 29.2 (F) Rubber Mat :- (i) Rubber mat 19mm thick and 1000mm wide laid for the entire length of panel - 01 No. Provision of numerical relay for 2 O/C & 1 E/F with master trip relay, trip ckt supervision relay, space heater and power pack for Control supply backup.\nNote:- The VCB shall be connected with existing VCB panel of make CG. The cost of connecting of VCB with extension of existing bus bar and making good shall deemed to be including in rate quoted by the contractor.
130 30 Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth for foundation / fixing pole / laying cable and pipe line etc or for man hole etc not exc 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed. 150 Cum
131 31 Returning filling in, including spreading, levelling, watering and well ramming in layers, not exceeding 25 cm thick using excavated soil complete all as specified and directed. 75 Cum
132 32 Removing excavated Soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. 75 Cum
133 33 Supply, laying, jointing and testing XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable, ISI marked, with aluminium multistranded conductor, 1100 volt grade of size 300 Sqmm, 3.5 core, laid in trenches / duct, passing through pipe / duct or fixed on pole etc including taking down old cable complete all as specified & directed. Make : Finloex/Havells/Polycab 50 RM
134 34 Supply, laying, jointing and testing XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable, ISI marked, with aluminium multistranded conductor, 1100 volt grade, of size 240 Sqmm, 3.5 core, laid in trenches / duct, passing through pipe / duct or fixed on pole etc including taking down old cable complete all as specified & directed. Make : Finloex/Havells/Polycab 100 RM
135 35 Supply, laying, jointing and testing XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable, ISI marked, with aluminium multistranded conductor, 1100 volt grade, of size 120 Sqmm, 3.5 core, laid in trenches / duct, passing through pipe / duct or fixed on pole etc including taking down old cable complete all as specified & directed. Make : Finloex/Havells/Polycab 90 RM
136 36 Supply, laying, jointing and testing XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable, ISI marked, with aluminium multistranded conductor, 1100 volt grade, of size 95 Sqmm, 3.5 core, laid in trenches / duct, passing through pipe / duct or fixed on pole etc including taking down old cable complete all as specified & directed. Make : Finloex/Havells/Polycab 90 RM
137 37 Supply and laying 80 mm bore Galvanised iron tubing, light grade, with all fittings such as sockets, elbow etc for protection of cable / earth continuity conductor, fixed to poles / walls / roof or laid in floors, road, crossing or ducts fixed with clamps, bolts nuts and washer etc including taking down old pipe complete all as specified and directed. Make : Jindal/TATA/ Prakesh Surya 18 RM
138 38 M&L for providing dry river sand as in sand cushioning below and above cable of the thickness specified in SSR to under ground electric cable including punning down of sand in layer complete all as specified and directed. \nNote: Punned thickness of sand only shall be measured for payment purpose. 54 Cum
139 39 Supply and laying common burnt bricks of sub class ‘B’ laid flat at right angle on the cable in trenches for cable protection including taking down old broken brick any type from the trenches etc complete all as specified and directed. 5930 Each
140 40 M&L mild steel framed work as in cage for fixing light fitting fabricated of angle, flat etc including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size, fixed over existing steel pole, and inclusive of one coat of red oxide primer, and two coats of aluminium paint all as specified and directed. 1.2 Qtl
141 41 M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.3 mm thick buried directly in ground ( earth pit not less than 2.25 Mtrs below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, connected to galvanised earth strip 32 x 6mm size up to 7.5 mtr long by means of bolts, check nuts and washers of galvanised steel, 20 mm bore, galvanised iron, medium grade watering pipe, and 40 mm bore galvanised iron light grade for protection of earth strip including all excavation, earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / Sqm) with cast iron frame, with charcoal, salt, funnel complete all as shown in the electrical plate No 5 of SSR part –I and testing on completion complete all as specified and directed.\nNote:- Quoted rates shall deemed to include cost of earth strip with protection pipe up to 7.5 M length. 16 Each
142 42 S&F in repair On load change over switch of 400 Amp capacity, 4 pole, with MS Enclosure made of 3.15 mm thick steel sheet and extensible handle mounting stand, made from 35 x 35 x 5mm thick channel, floor mounted and fixing in ground and necessary mounting accessories complete all as specified and directed. Make : - Havells Model : IHCNFO0400 or equivalent model of L&T / C& S / Schinder 2 Each
143 43 S&F in repair On load change over switch of 200 Amp capacity, 4 pole with MS Enclosure made of 3.15 mm thick steel sheet and extensible handle mounting stand made from 35 x 35 x 5mm thick channel, floor mounted and fixing in ground and necessary mounting accessories complete all as specified and directed. Make : - Havells Model : IHCNFO0200 or equivalent model of L&T / C& S / Schinder 2 Each
144 44 S & F in repair distribution board (DB), double door type, made out of sheet metal enclosure (CRCA sheet) dust and vermin proof MCCB DB, TPN 4 way with 200 Amps rated copper bus bar, 415 Volts with in built MCCB 125 Amps, 10 KA, 01 No., earth bar IP 43 protection, flush to wall complete all as specified and directed. Make : Legrand Model: 5077 45 or equivalent model of Havells/ Siemens/ Schneider (Acti-9). 2 Each
145 45 S & F in repair distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 4 way with 200 Amps rated copper bus bar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, flush to wall complete all as specified and directed. Make : Legrand Model: 5076 10 or equivalent model of Siemens / Schneider (Acti-9). 2 Each
146 46 S & F in repair distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 8 way with 200 Amps rated copper bus bar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, flush to wall complete all as specified and directed. Make : Legrand Model: 5076 11 or equivalent model of Siemens / Schneider (Acti-9). 2 Each
147 47 S & F in repair MCB TPN 63 Amp complete all as specified and directed.\nMake - Havells/ Legrand/Standard/ABB 5 Each
148 48 S & F in repair MCB SPN, 240 Volts, 63 Amps complete all as specified and directed. Make-Havells/ Legrand/Standard/ABB 2 Each
149 49 S & F in repair MCB SP 240 Volts, 6 to 32 Amps complete all as specified and directed. Make- Havells/ Legrand/Standard/ABB 10 Each
150 50 S & F in repair MCB SP 240 Volts, 40 to 63 Amps complete all as specified and directed. Make- Havells/ Legrand/Standard/ABB 10 Each
151 51 M & L Sub main wiring using two run of single core PVC insulated FRLS cable 4.0 Sqmm copper conductor multi stranded and 4.0 Sqmm copper conductor insulated cable using as earth wire, drawing in to and including 25 mm dia medium grade PVC conduit inclusive of boxes (junction/terminal) all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings fixed on wall/ceiling with PVC saddles including taking down old sub main wiring complete all as specified and directed. \nNote : Two runs of 4.0 Sqmm copper FRLS cable & one run of 4.0 Sqmm copper cable in and including 25mm PVC conduit medium grade shall be measured as one unit. \nMake for conduit : Plaza/Precision/AKG & Make for wire : Anchor/ Ploycab/Havells 180 Per RM
152 52 M & L Sub main wiring using two run of single core PVC insulated FRLS cable 6.0 Sqmm copper conductor multi stranded and 6.0 Sqmm copper conductor insulated cable using as earth wire, drawing in to and including 25 mm dia medium grade PVC conduit inclusive of boxes (junction/terminal) all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings fixed on wall/ceiling with PVC saddles including taking down old sub main wiring complete all as specified and directed. \nNote : Two runs of 6.0 Sqmm copper FRLS cable & one run of 6.0 Sqmm copper cable in and including 25mm PVC conduit medium grade shall be measured as one unit. \nMake for conduit : Plaza/ Precision/AKG & Make for wire : Anchor/ Ploycab/Havells 120 Per RM
153 53 M & L Sub main wiring using four run of single core PVC insulated FRLS cable 10.0 Sqmm copper conductor multi stranded and 10.0 Sqmm copper conductor insulated cable using as earth wire, drawing in to and including 32 mm dia medium grade PVC conduit inclusive of boxes (junction/terminal) all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings fixed on wall/ceiling with PVC saddles including taking down old sub main wiring complete all as specified and directed. \nNote : Four runs of 10.0 Sqmm copper FRLS cable & one run of 10.0 Sqmm copper cable in and including 32mm PVC conduit medium grade shall be measured as one unit. \nMake for conduit : Plaza/ Precision/AKG & Make for wire : Anchor/ Ploycab/Havells 50 Per RM
154 54 M & L Sub main wiring using four run of single core PVC insulated FRLS cable 16.0 Sqmm copper conductor multi stranded and 16.0 Sqmm copper conductor insulated cable using as earth wire, drawing in to and including 32 mm dia medium grade PVC conduit inclusive of boxes (junction/terminal) all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings fixed on wall/ceiling with PVC saddles including taking down old sub main wiring complete all as specified and directed. \nNote : Four runs of 16.0 Sqmm copper FRLS cable & one run of 16.0 Sqmm copper cable in and including 32mm PVC conduit medium grade shall be measured as one unit. \nMake for conduit : Plaza/ Precision/AKG & Make for wire : Anchor/ Ploycab/Havells 51 Per RM
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail