}

Notice Inviting Tender For Prequalification Cum Supply Of Gratings, RCF LTD MUMBAI-Maharashtra

Rashtriya Chemicals And Fertilizers Limited has published Notice Inviting Tender For Prequalification Cum Supply Of Gratings. Submission Date for this Tender is 24-12-2019. Bearings Tenders in RCF LTD MUMBAI Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

22833726
Notice Inviting Tender For Prequalification Cum Supply Of Gratings
Tender
Indian
Maharashtra
Rcf Ltd Mumbai
24-12-2019

Tender Details

Notice Inviting Tender For Prequalification Cum Supply Of Gratings , Grating G . I: Size: 0 . 8M X 0 . 3MMade Out Of 30 X 5 Mm Bearing Bar And Frame Bar Spaced At 40 Mm ( Max . ) C/C And Crossbar 12 X 5 Mm Spaced At 100 Mm ( Max . ) C/C . Crossbar To BeRun In 12 Mm Deep Groove In The Bearing Bar . Bearing Bar , Frame Bar AndCrossbar Shall Be Welded Firmly To Each Other At Joints . Bearing BarShould Be Placed Along The Span I . E . Breadth Wise . Moc: Is 2062 Duly Hot Dipped Galvanised As Per Is 2629 To Give More Than80 Micron Thickness . Note:- ( 1 ) Mtc And Galvanising Report To Be Furnished Along With Supply . ( 2 ) Supplier To Give Guarantee Against Poor Workmanship For A Period Of18 Months From The Date Of Supply . , Ms Galvanised Grating-G . I Size: 1M X 1M , Made Out Of 30 X 5 Mm Bearing Bar &Frame Bar , Spaced At 41 Mm C/C & Cross Bar 12 X 5 Mm Spaced At 100 MmC/C . Cross Bars To Be Run In 13 Mm Deep Groove , In The Bearing Bar . Bearing Bar , Frame Bar And Cross Bars Shall Be Welded Firmly To EachOther At Joints . Bearing Bars Should Be Placed Along The Span I . E . Breadth Wise . Moc: Is2062 Duly Hot Dip Galvanized As Per Is: 2629 , To Give More Than80 Micron Thickness . Note:- ( 1 ) Mtc And Galvanising Report To Be Furnished Along With Supply . ( 2 ) Supplier To Give Guarantee Against Poor Workmanship For A Period Of18 Months From The Date Of Supply . , Ss 304 Gratings For C001 Tower . Moc - Ss 304 , Size 1M X 1M , Welded Construction , Bearing Bar Spacing ( Center To Center ) 40Mm , Cross Bar Spacing ( Center To Center ) 100 Mm , Bar Thickness 5Mm , Bar Height 30 Mm , Grating G . I: Size: 1 . 5M X 1M , Made Out Of 30 X 5 Mm Bearing Bar & FrameBar , Spaced At 41 Mm C/C & Cross Bar 12 X 5 Mm Spaced At 100 Mm C/C . Cross Bars To Be Run In 13 Mm Deep Groove , In The Bearing Bar . BearingBar , Frame Bar And Cross Bars Shall Be Welded Firmly To Each Other AtJoints . Bearing Bars Should Be Placed Along The Span I . E . Breadth Wise . Moc: Is2062 Duly Hot Dip Galvanized As Per Is: 2629 , To Give More Than80 Micron Thickness . Note:- ( 1 ) Mtc And Galvanising Report To Be Furnished Along With Supply . ( 2 ) Supplier To Give Guarantee Against Poor Workmanship For A Period Of18 Months From The Date Of Supply . , Ms Galvanised Grating;Size- 900 Mm X 300 Mm , Made Out Of 30 X 5 Mm Bearing Bar And Frame Bar Spaced At 40 Mm ( Max . ) C/C And Crossbar 12 X 5 Mm Spaced At 100 Mm ( Max . ) C/C . Crossbar To Be Run In 12 Mm Deep Groove In The Bearing Bar . Bearing Bar , Frame Bar And Crossbar Shall Be Welded Firmly To Each Other At Joints . Bearing Bar Should Be Placed Along The Span I . E . Breadth Wise . Moc: Is 2062 Duly Hot Dipped Galvanised As Per Is 2629 To Give More Than 80 Micron Thickness . Note:- ( 1 ) Mtc And Galvanising Report To Be Furnished Along With Supply . ( 2 ) Supplier To Give Guarantee Against Poor Workmanship For A Period Of 12 Months From The Date Of Installation Or 18 Months From The Date Of Supply , Whichever Is Earlier . , Grating-G . I Size: 1M X 0 . 3M , Made Out Of 30 X 5 Mm Bearing Bar And Frame Bar Spaced At 40 Mm ( Max . ) C/C And Crossbar 12 X 5 Mm Spaced At 100 Mm ( Max . ) C/C . Crossbar To BeRun In 12 Mm Deep Groove In The Bearing Bar . Bearing Bar , Frame Bar AndCrossbar Shall Be Welded Firmly To Each Other At Joints . Bearing BarShould Be Placed Along The Span I . E . Breadth Wise . Moc: Is 2062 Duly Hot Dipped Galvanised As Per Is 2629 To Give More Than80 Micron Thickness . Note:- ( 1 ) Mtc And Galvanising Report To Be Furnished Along With Supply . ( 2 ) Supplier To Give Guarantee Against Poor Workmanship For A Period Of18 Months From The Date Of Supply . , G I Grating , Size : 1200 Mm X 300 Mm , Made Out Of 30 X 5 Mm Bearing Bar & Frame Bar , Spaced At 41 Mm C/C & Cross Bar 12 X 5 Mm Spaced At 100 Mm C/C . Cross Bars To Be Run In 13 Mm Deep Groove , In The Bearing Bar . Bearing Bar , Frame Bar And Cross Bars Shall Be Welded Firmly To Each Other At Joints . Bearing Bars Should Be Placed Along The Span . Moc: Is2062 Duly Hot Dip Galvanized As Per Is: 2629 , To Give More Than 80 Micron Thickness . Note:- ( 1 ) Mtc And Galvanising Report To Be Furnished Along With Supply . ( 2 ) Supplier To Give Guarantee Against Poor Workmanship For A Period Of 12 Months From The Date Of Installation Or 18 Months From The Date Of Supply , Whichever Is Earlier .

Key Value

Document Fees
Refer document
EMD
INR 30000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail