Housing Urban and Rular Development Government Departments Closing in 0 days TDR #22825054

Construction Of Common Building For Conference Hall Bank And Modern Canteen At Igc Chaygaon Chatabari Under Upgradation Of Igc Chaygaon Project

Issued by Government Departments · IGC Chaigaon, Assam
Tender Value
1.03 Crore
Estimated cost
Bid Submission
20 Dec 2019
0 days left
EMD
2.06 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
IGC Chaigaon → Assam
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of Common Building For Conference Hall Bank And Modern Canteen At Igc Chaygaon Chatabari Under Upgradation Of Igc Chaygaon Project

BOQ

Name of Work: Construction of Common Building for Conference Hall, Bank & Modern Canteen at IGC Chaygaon, Chatabari” under Up-gradation of IGC Chaygaon project.. Gr-V
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tanks etc. including refilling (Return filling) the quantity as necessary after completing of work, breaking clods in return filling, dressing, watering and ramming etc and removal of surplus earth with all lead and lifts as directed and specified in following classifications of soils including bailing out water where necessary as directed and specified. Upto a depth of 2 mts. below the existing Ground Level (A) In ordinary Soilitem1225Cum
22Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (C) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.item290Cum
33Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop. 1:3: 6 (1 cement:3 coarse sand : 6 coarse agg. by volume (using mixture machine) (under footing)item318Cum
44Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.item426Sqm
55Providing and laying plain/reinforced cement croncrete works cement with coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (1) Using mixture machine (A) In sub - structure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. (N) Without using admixture, plasticiser (c) M25 grade concreteitem552Cum
66Super-structure from plinth level upto 1st floor level. (ii) Columns, Pillars, Posts, Struts, Suspended Floor, Roof, Landing, Shelf and support, Balcony, Lintel, Sill Band, Beam, Girder, Bressumer, Cantilever, Staircase (Except Spiral Staircase and landing) including preparing the top surface and finishing of nosing. (N) Without using admixture, plasticiser. (c) M25 grade concreteitem684Cum
77Extra over item Nos. 2.2.1 (I) (B), above for each subsequent floor or part thereof above the 1st floor level.item723Cum
88Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in:item81045sqm
99Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a) Brick on flat soling.item9195sqm
1010Brick work in cement mortar with 1st class bricks including racking out joints and curing complete. (i) In sub-structure upto plinth level including dewatering. (b)In Prop 1:4item1020Cum
11111st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth upto 1st floor (Protruding M.S Rod/ Torsteel of column to be embedded in cement mortar and will measured and paid separately) (A) 112 mm thick brick wall (a) In cement mortar in proportion 1:4 ( 1 cement: 4 sand)item11470Sqm
1212Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified. (a) With sal wooditem120.5Cum
1313Providing and fixing Flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panel conforming to relevent to IS Code including oxidised iron butt hinges (100 mm X 75 mm X 3.5 mm) 6 nos. with necessary wood screws. (b) Non Decorative Type and Block Board core (ii) 35 mm thickitem138sqm
1414Providing, fitting and fixing 24mm/29mm thick polymer reinforced moulded PVC door shutters fixed to the chowkaths with necessary, hinges screws, bolts etc. as specified and directed at all levels ( door fixtures and fittings to be measured and paid separately ) (b) 29mm thickitem148Sqm
1515Supplying, fitting and fixing in position reinforcement bars conforming to relevent IS code for R.C.C work/ R.B walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports , chairs, spacers etc. complete. (a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL (i) TMT Corrosion resistant steel (CRS) reiforcement baritem15220Qtl
1616Providing, fitting and fixing M.S. grills of required pattern for windows/ clerestory/ openings with M.S. flats at required spacing and frame all round, square or round M.S. bar with round headed bolts and nuts or screws. (I) Plain Grill (c) Fixed to Brickwork/P.C.C/R.C.C.item1650Sqm
1717Providing, fitting, hoisting and fixing of roof trusses fabricated out of combination of any two or all of the following sections (i) Square section (ii) Rectangular Hollow section of specification RSH/SHS and (iii) M.S. circular hlollow section of Grade 210 including purlins, bottom runners and providing M.S. cleat, M.S. angle base plank, bolts and nuts with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications. (a) Using TATA make RHS/SHS of Grade 310 conforming to relevant I.S. code 4923 : 1997item1740Qtl
1818Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) M/F Suspended Ceiling which includes G.I. perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to brick wall/ partition with the help of nylon sleeves and screws, at 610mm c/c. Then suspending G.I. intermediate channels of size 45mm (0.9mm thick with two equal flanges of 15mm each) from the soffit at 1220mm c/c with ceiling angle of width 25mmx10mmx0.55mm thick fixed to soffit with G.I.cleat and steel expansion fasteners. Ceiling section of 0.55mm thickness having knurled web of 51.5mm and two equal flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip and in direction perpendicular to the intermediate channel at 457mm c/c, 9.5mm/ 12.5mm tapered edge Gypboard (conforming to IS:2095-1982) is then screw fixed to ceiling section with 25mm long drywall screws at 230mm c/c. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally, the boards are to be jointed and finished so as to have a flush look which includes filling and finishing the tapered and square edges of the boards with jointing compound, joint paper tape and two coats of drywall topcoat suitable for Gypboard complete at all levels as specified and directed. (For light fittings, providing opening for doors, window, ventilators etc, cut out made with frame of perimeter channel supported suitably to be measured and paid separately where necessary). (ii) 12.5mm thick MRB Board \n\n\nitem18174Sqm
1919Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) wall lining which includes 12.5mm thick Louvertone/ Sundance/ Cratone/ Fulltone (slit) Gypboard ceiling panels of size 595mmx595mm (conforming to IS:2095-1982) screw fixed to the Ceiling section of size 0.55mm thick having a knurled web of 51.5mm and two equal flanges of 26mm each with lips of 10.5mm made of G.I. Steel placed at 298mm c/c in perimeter channels of size 0.55mm thick having one flange of 20mm and flane of 30mm and a web of 27mm made of G.I. Steel fixed to the floor & ceiling with nylon sleeves & wood screws at 600mm c/c. Finally the boards are to be jointed and finished so as to have a Flush look which includes filling and finishing with jointing Compound, joint paper tape, two coat drywall top coat suitable for Gypboard complete as specified and directed at all levels (Glass wool to be measured and paid separately) (For light finishing, skirting providing opening for doors, windows, ventilators etc. cut out made with the frame of perimeter channel supported suitably to be measured and paid suitably when necessary). (A) M/F wall lining with Design Type Semi Perforated (Sundance) Gypboard 12.5mm thick (NRC value=0.20 with 50mm glass wool mat backing).item19100Sqm
2020Providing Pre Painted Galvanized Iron Sheet Roofing (PPGI) at all levels including fitting and fixing with self drilling, self tapping screws complete. (Roof trusses, purlins etc. to be measured and paid separately.) TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement (ii) 0.45 mm thickitem20340Sqm
2121Providing Pre Painted Galvanized Iron Sheet (PPGI) accessories (Ridges / Valley / Gutter /Flashing) at all levels including fitting and fixing self drilling, self tapping screws complete complete. TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement (iii) 0.45 mm thickitem21110Rm
2222Plain cement concrete floor base in prop1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. complete. (b) 50mm thickitem22195Sqm
2323Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) (a) Normal range Somany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make (ii) Of size 600mmx600mm and aboveitem23285Sqm
2424Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls). (a) Normal range Somany/ Orient/Nitco/Asian Make (ii) Of size 200mmx300mm and aboveitem24185sqm
2525Providing Antiskid tiles of approved quality size, shape not less than 8mm on floor, skirtings over a cement mortar bed 15mm thick of 1:3 (1 cement : 3 coarse sand) approved make fix with Fix-A-Tile ( Choksey/Sika/Pedelite/Rouf)/white cement complete at all level as specified and directed. (A) Ceramic tiles (iii) Executive range a) Deluxe VC (Sizes 600mmX600mm and above) (a0 Somany madeitem2542Sqm
262618 mm thick Marble stone slab flooring of sizes 1200x1200 including treads and risers of steps, skirting, laid over 20 mm thick base of cement plaster 1:6 (1 cement : 6 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with marble slab of specified quality and shade at all levels. (i) Marwat Slabitem26115Sqm
272710 mm thick cement plaster in single coat on fair side of brick/ concrete walls for interior platering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. (a0 In cement mortar 1:3item27310Sqm
282815 mm thick cement plaster in single coat on rough side of single or half brick wall for interior plastering upto 1st floor level including arises, internal rounded angles, chamfers and/ or rounded angles not exceeding 80 mm in girth and finished even and smooth including curing complete as directed. (b) In cement mortar 1:4item28210Sqm
292915 mm thick cement plaster in single coat on fair side of brick / concrete for interior plastering upto 1st floor level including arises, internal rounded angle chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. (b) In cement mortar 1:4item29465sqm
303020 mm thick cement plaster in two coat, backing coat 15 mm anf finishing coat 5 mm thick on rough side of single or half brick for interior plastering upto 1st floor level including arises, internal rounded angle chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. (A) On rough side (backing coat 15 mm and finishing coat 5 mm thick) (b) In cement mortar 1:4item30385Sqm
3131Extra over item no 6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.item31310sqm
3232Extra over item no 6.2.1 to 6.2.3 for exterior plastering over wall up to a height of 1st floor level above ground level including curing complete as directed. (b) Two coat plasteritem32385Sqm
3333Extra over item no 6.2.1to 6.2.3 for interior plastering above 1st floor level for every addl floor or part thereof including curing complete as directed. (b) On two coat plasteritem33300sqm
3434Extra over item no 6.2.1 to 6.2.3 for exterior plastering over wall for every addl floor or part thereof beyond 1st floor level including curing complete as directed. (b) On two coat plasteritem34195sqm
3535Providing two coats of J.K Wall Putty ( White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm)item35985Sqm
3636Wall painting (two coats) with Plastic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a) Plastic Emulsion Paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)item36985sqm
3737Finishing old / new wall with water proofing weather coat smooth anti-fungal exterior painting of approved make of Berger paint of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)item37200Sqm
3838Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting. (b) With ready mixed paint , wood primer (white).item3816Sqm
3939Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping. (i) Surfaces over 100mm in width or girth. (a) General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).item3916sqm
4040Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. (a) With ready mixed \"Red-Lead\"/red oxide primeritem4010Sqm
4141Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (i) Surfaces over 100mm in width or girth (a) General purpose (Asian paint/ Berger paint/ ICI paint/ J&N paint/ Nerolac.)item4110sqm
4242Providing, fitting and fixing anodised aluminium windows and ventilators of standard sections of approved brand without horizontal glazing bars joints mitred and welded (manufactured to relevant IS specifications) fitted with 6mm x 3.15mm lugs 100mm long embedded in CC blocks 150mm x 100mm x 100mm in 1:3:6 mix including providing and fixing handles, frictions stays, joining cleat, bolting device, locking arrangement, spring catch as required complete as specified and directed for all levels. (Cement concrete to be measured and paid separately). (a) Side hung and Top hung windows and ventilators. (v) 5 mm coloured glassitem426Sqm
4343Providing, fitting and fixing anodised aluminium framed double leaf glazed doors with anodised aluminium frame made of 100mm x 45mm x 2mm sections with door styles of size 81mm x 45mm x 2mm, top rails 50mm x 45mm x 2mm, lock rails 81 mm x 45mm x 2mm,bottom rails 100mm x 45mm x 2mm fitted with glazing clip, special type rubber gasket complete including hydraulic floor spring, pivot, tower bolt in each leaf, aluminium door handle, lock, angles, cleat etc complete as specified and directed by the Department at all levels. (iii) 6mm coloured glassitem4322Sqm
4444Providing, fitting and fixing aluminium curtain wall on the exterior face of building fitting to concrete member by drilling hole fixing by brass screw fabricated with anodised aluminium section of approved brand of size 101mm x 44.50mm by providing aluminium jointing angles including providing 6mm thick coloured reflectory type glass fitted with aluminium at all levels.item44135Sqm
4545Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) (a) Sliding door bolts (i) 300 mm x 16 mmitem452Each
4646(b) Tower Bolt (ii) 250 mm x 12 mmitem4624Each
4747(c) Door Handle (iii) 150 mmitem4718Each
4848(t) Door stopper with rubber stopperitem484Each
4949SANITARY WORKS : Providing fitting and fixing vitreous china pedestal type water closet (European type W.C pan 400mm high ) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately) C) Jaquar make (a) White. (i) Size 530 x 370x 360 (Cat No.CNS-WHT-WS01) (inclusive of seat cover)item495Each
5050Supplying, fiting and fixing PVC flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately) (i) Parryware make (a) White (i) Economy Single Flush (Cat No.C8090/C8055)item505Each
5151Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately) 1.13.2 Basin (without pedestal) (A) Parryware Make (i) Star Basin 550 x 400 (Cat. No.C0450)item515Each
5252Providing fitting and fixing vitreous china flat back type lipped front urinal basin with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required. (C) Jaquar Make (a) White (i) Compact (Cat.No.URS-WHT-0702)item524Each
5353Providing fitting and fixing Mirror with plastic frame of size 500x400mm complete as directed and specified.item535Each
5454Providing fitting and fixing Glass Shelf complete as directed and specified. (ii) Sona make (Cat. No.TR-0701) (c) 600mmitem546Each
5555Providing, fitting and fixing CP soap tray / soap dish complete as directed and specified. (a) Continental (Cat.No.ACN-1331N)item556Each
5656Providing, fitting and fixing CP towel rail complete as directed and specified. (b) Sona make (ii) Towel rail Diplomat 450mm long (Cat.No.TR-0605)item566Each
5757Providing fitting and fixing Chrome Plated (CP) Toilet paper holder of Jaquar make complete as directed and specified. (d) Sona make (i) Super (Cat. No.AL-1001)item575Each
5858Providing fitting & fixing stainless steel kitchen sink of Parryware make with CI/MS brackets, C.P. brass chain with rubber plug, PVC waste pipe etc. complete including painting the fittings ,cutting &making good the walls wherever required. (Sink cock, stop cocks, waste coupling are to be paid separately. (ii) Single Bowl with Drain Board (400 x 200) Flat Edge - Glossy (Cat.No.C8537)item581Each
5959Supplying fiting and fixing PVC pipes of 6Kgf/cm2 (Supreme/Prince) or ISI approved including joining , fitting and fixing with clamps etc. as necessary complete at all levels including below G.L. as directed and specified. (a) In exposed surface or trenches. (ii) 110mm dia.item5910Rm
606075mm dia.item6010Rm
6161Concealed by chiselling or breaking brickwall/C.C/R.C.C and making good to the damages. (ii) 110mm dia.item6110Rm
626275mm dia.item6210Rm
6363Supplying fiting and fixing 87.5 degree PVC bend of (Supreme/Prince) or ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. (a) In exposed faces or trences (ii) 110mm dia.item635Each
646475mm dia.item645Each
6565Concealed by chiselling or breaking brickwall/C.C/R.C.C and making good to the damages. (ii) 110mm dia.item655Each
6666(iv) 75mm dia.item665Each
6767Supplying fitting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (a) In exposed faces or trences (ii) 110mm dia.item675Each
6868Concealed by chiselling or breaking brickwall/C.C/R.C.C and making good to the damages. (ii) 110mm dia.item685Each
6969Supplying fitting and fixing 45 degree PVC bend of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (a) In exposed faces or trences. (ii) 110mm dia.item6910Each
7070(iv) 75mm dia.item7010Each
7171Concealed by chiselling or breaking brickwall/C.C/R.C.C and making good to the damages. (ii) 110mm dia.item7110Each
7272(iv) 75mm dia.item7210Each
7373Supplying fiting and fixing PVC Plain single tee of (Supreme/ Prince) or ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. (a) In exposed faces or trences. (ii) 110mm dia.item736Each
7474(iv) 75mm dia.item746Each
7575Concealed by chiselling or breaking brickwall/C.C/R.C.C and making good to the damages (ii) 110mm dia.item756Each
7676(iv) 75mm dia.item766Each
7777Supplying fiting and fixing PVC single 'Y' with door of (Supreme/ Prince) or ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. (a) In exposed faces or trences. (i) 110mm dia.item772Each
7878(ii) 75mm dia.item782Each
7979Concealed by chiselling or breaking brickwall/C.C/R.C.C and making good to the damages. (i) 110mm dia.item795Each
8080(ii) 75mm dia.item805Each
8181Supplying fiting and fixing PVC cross 'T' plain of (Supreme/Prince) or ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. (a) In exposed faces or trences. (i) 110mmx110mmitem812Each
8282(ii) 75mmx75mmitem822Each
8383Concealed by chiselling or breaking brickwall/C.C/R.C.C and making good to the damages (i) 110mmx110mmitem834Each
8484(ii) 75mmx75mmitem844Each
8585Supplying fiting and fixing PVC coupler of (Supreme/Prince) or ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. (a) In exposed faces or trences (ii) 110mm dia.item854Each
8686(iv) 75mm dia.item864Each
8787Concealed by chiselling or breaking brickwall/C.C/R.C.C and making good to the damages. (ii) 110mm dia.item876Each
8888(iv) 75mm dia.item886Each
8989Supplying fiting and fixing PVC reducer of (Supreme/Prince) or ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. (a0 In exposed faces or trences (iv) 110 mm x 75 mmitem894Each
9090Concealed by chiselling or breaking brickwall/C.C/R.C.C and making good to the damages (iv) 110 mm x 75 mmitem906Each
9191Supplying fiting and fixing PVC reducing Tee of (Supreme/Prince) or ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. (a) In exposed faces or trences (ii) 110 mm x 75 mmitem912Each
9292Concealed by chiselling or breaking brickwall/C.C/R.C.C and making good to the damages. (iv) 110 mm x 75 mmitem924Each
9393Providing fitting and fixing 110mm dia. PVC cowel of ISI make complete as directed and specified.item935Each
9494Providing fitting and fixing C.I grating to the floors complete as directed and specified. (b) 75 mm diaitem9414Each
9595Providing fitting and fixing 450mm dia. 90mm thick C.I. Man hole cover and frame of 25 Kg. Weight complete as directed and specifieditem952Each
9696Construction of filter bed in soak pit including earth work in excavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C. plain sheet above brick bat filling complete as directed.item964Cum
9797Construction of inspection pit inside measurement 450mm x 450mm x 450mm flush with 100mm diameter HCI/ PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling, 12cm brick wall in cement mortar in proportion 1:4 finished with 13mm cement plaster in proportion 1:2 in side wall and floor. 450mm x 450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pit as directed.item972Each
9898WATER SUPPLY: Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc.complete at all levels including below G.L. as directed and specified. (I) Exposed or in trenches (b) 40 mm dia (i) Using Tata (medium)item9810Rm
999932 mm dia (i) Using Tata (medium)item9915Rm
100100Concealed by chieselling or breaking brick wall/ C.C. wall/ R.C.C. wall and making good to the damaged structure. (d) 25 mm dia (i) Using Tata (medium)item10014Rm
10110120 mm dia (i) Using Tata (medium)item10112Rm
10210215 mm dia (i) Using Tata (medium)item10212Rm
103103Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) (II) Jaquare make (a) Continental /Clarion (i) Standarditem10315Each
104104Supplying fitting and fixing chorome plated (C.P) stop-cock of approved brand and size as mentioned below as directed and specified.(G.I. & C.P pipes will be measured and paid separately) (IV) Sona brand (a) 15mm dia Stop cock male-female /Angle stop cockitem10415Each
105105Supplying and fitting fixing C.P. pillar cock of 15mm dia of approved brand as specified and directed. (I) SONA make (a) Light typeitem1055Each
106106Supplying fitting and fixing chorome plated (C.P) sink-cock of approved brand and size as mentioned below as directed and specified.(G.I. & C.P pipes will be measured and paid separately) (V) Jaquar make (a) Continental /Clarion (ii) Sink-cock with raised 'J' shaped swinging spoutitem1061Each
107107Supplying and fitting gun metal country pit valve ( full way valve) I.S.I Make as specified and directed. (b) 40 mm diaitem1072Each
108108(c) 25 mm diaitem1082Each
109109(d) 20 mm diaitem1092Each
110110Supplying and fitting gun metal check valve I.S.I Make as specified and directed. (b) 40 mm dia ( Heavy type)item1102Each
111111WATER TANK : Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes (iii) 1000 Lt capacity (i) Sintex makeitem1112Each
112112Labour for erecting and placing PCVC Tank over the stagging up to a height of 5.00m complete as directed. (c) 1000 Lt capacityitem1122Each
113113Septic Tank : Supplying and placing ferrocement septic tanks of rectangular shape in to pit with manhole cover with cleaning arrangement over single brick flat soling and 75mm 1:3:6 P.C.C. Baffle wall, inlet and outlet etc are provided at suitable points complete as directed. (iv) 25 Users\nitem1131Each
114114Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. 2.7.1 With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.item114700RM
1151152.7.2 With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.item115100RM
1161162.7.3 With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.item116180RM
1171172.7.4 With 2 x 10 sq. mm. + earth continuity with 1x 6 sq. mm. cable in 32 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.item117140RM
118118Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. 2.9.4 With 4 x 10 sq. mm. + earth continuity with 2x6 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.item11860Metre.
119119Wiring for 5 pin 6 amp plug with 1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) including 5 pin 6 amp socket outlet (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) and 6 amp flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) earthing the 3rd pin of the socket as required on the switch board in surface/ recessed P.V.C. conduit wiring system. When fitted on same board of light and fan.item11950Each
120120Wiring to 5 Aa pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete. 2.12.2 Medium point up to 6.00 metre. Length.item12012Each
121121Long point up to 10.00 metre. Length.item12114Each
122122Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) 2.13.3 Long point up to 10.00 metre. Length.item1226Each
123123Wiring for light/fan/call bell point with 3x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) ceiling rose etc. complete. 2.17.1 Short point up to 3.00 metre. length.item12330Each
124124Medium point up to 6.00 metre. Length.item12444Each
125125Long point up to 10.00 metre. Length.item12535Each
126126MODULAR SWITCH : Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE in surface/ recessed system complete as per direction of department. SB. 8.34.1 1-2 module type Metalitem1266Each
1271273 module type Metalitem12712Each
1281284-5 module type Metalitem12810Each
1291296-8 module type Metalitem12930Each
13013012-16 module type Metalitem1302Each
13113124 module type Metalitem1313Each
132132Supplying including fitting fixing of following front plate of suitable colour MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE as per direction of department. SB. 8.37.1 1 moduleitem1322Each
133133SB. 8.37.2 2 moduleitem1334Each
134134SB. 8.37.3 3 moduleitem13412Each
135135SB. 8.37.4 4 moduleitem13510Each
136136SB. 8.37.6 6 moduleitem1366Each
137137SB. 8.37.7 8 moduleitem13724Each
138138SB. 8.37.9 16 moduleitem1382Each
139139SB. 8.37.10 24 moduleitem1393Each
140140Supplying with fitting fixing of blank plate single in modular switch system MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE complete as per direction of department.item14020Each
141141Supplying including fitting and fixing of TV co-axial outlet MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells complete as per direction of department.item1411Each
142142Supplying with fitting and fixing of RJ-11 Telephone jack MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA)A), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection complete as per direction of department.item1421Each
143143Supplying with fitting and fixing of Single Phase Modular Motor Starter switch MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department. SB. 8.44 Modular Motor Starter switch Relay Range 16 - 25 Amps in 3 Moduleitem1436Each
144144Supplying with fitting and fixing of 100 watt electronic modular fan speed controller 4 - Step 2 - module type MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department.item1448Each
145145Supplying including installation of socket outlet 6/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department.item1456Each
146146Supplying including installation of socket outlet 6 Amps 3 pin combine shuttered complete , MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department.item14676Each
147147Supplying with fitting fixing of 16 amp one way modular clip in switch, MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department.item1476Each
148148Supplying with fitting fixing of 6 amp one way modular clip in switch, MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department.item148185Each
149149EPABX : Supplying ,installation, testing & commissioning of 2 pair Unarmoured Telephone Cable through existing conduit in surface/ recess system.item14950Metre.
150150Wiring for Co - axial Jelly Flooded (Unarmoured) (FINOLEX /RR KABEL /NICCO / ANCHOR make) cable in existing surface conduit wiring system including connection etc as required. 9.3.2 Co - axial Jelly Flooded (Unarmoured) RG 6 (Copper)item15040Metre
151151Supply and fixing of 19 mm dia 1.50mm to 2.00mm average wall thickness heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) on surface system including painting etc as required:item15170Metre
152152Supplying and fixing of bulk head fitting suitable for CFL lamp complete with all accessories including 20 watts CFL lamp and connection as approved by the Deptt.)as required. [BH ]item1523Each
153153Supplying and fixing of Fan box (AKG or equivalent as approved by the Deptt.)with inbuild rod as required.item1538Each
154154INDUSTRIAL SOCKETS, DB Without MCB & MCCB , MCB, RCCB, RCBO, SFU, CHANGE OVER ETC. (ABB, Schneider MG, legrand, Hager make) Supplying fitting and fixing industrial Plug & Socket in surface mounting SPN sheet steel powder painted MCB DB incorporated with MCB DIN rail, neutral link Earth bar of the following rating of DP MCB complete with making necessary connection etc. as specified and directed by the Deptt. 13.1.1 20A Capacity. (ABB, Schneider MG, legrand, Hager make)item1546Each
155155MCB IN-comer SPN DB : Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. 15.2.1.4 12 way SPN Double Dooritem1554Each
156156MCB IN-comer TPN (Horizontal DB) : Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. 15.8.1 ABB, Schneider MG, legrand, Hager make) 15.8.1.1 4 way TPN (4+12) double dooritem1562Each
157157Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.1.2 C Series (Schneider MG, legrand, Hager make) 16.1.2.1 6 to 32Aitem15744Each
158158Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.3.2 C Series (ABB, Schneider MG, legrand, Hager make) 16.3.2.2 40Aitem1584Each
159159Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DP RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.7.2 100/300mA sensitivity DP RCCB (ABB, Schneider MG, legrand, Hager make) 16.7.2.2 40Aitem1594Each
160160Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.6.2 C Series (ABB, Schneider MG, legrand, Hager make) 16.6.2.2 40Aitem1602Each
161161EARTHING: Supply, installation & testing of G.I. earth station with perforated 40 mm dia and 4.50 Metre long heady duty G.I. pipe with necessary 40 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .item1612Each
162162Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt.item1622Each
163163Supply, installation & testing of Copper Plate earth station with 600 mmx600 mmx3 mm copper earth plate with necessary 40 mm dia. G.I. medium duty watering pipe with G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement with 300 mmx300 mmx6 mm C.I. hinged cover plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .item1632Set
164164Extra for using salt (5 K and Charcoal (96 K in G.I./Copper plate Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the deptt .item1642Set
165165Supplying & laying of 6 SWG G.I. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.item16570Metre.
166166Supplying & laying of 25X5mm size G.I. strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of G.I. nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt.item16640R.M.
167167Supplying & laying of 25X5mm size Copper strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of Brass nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt.item16740R.M.
168168Supplying including fitting fixing of following A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department [Without regulator]. 27.1.2 Premium model 1200 mm Sweep (ORIENT PSPO make) / Premium model 1050 / 1200 mm Sweep SS-390 Deco Havells make) [ F ]item1688Each
169169Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. 27.2.1 Domestic. 27.2.1.12 Ventil Air DB 300 mm sweep (Havells make) [EF]item1697Each
170170Heavy Duty 450 mm sweep 900 RPM Single phase (ORIENT make) [EFH ]item1702Each
171171Supplying including fitting fixing of following A.C. Wall fan in the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. 27.4.1 (CROMPTON /ORIENT/Havells/USHA or equivalent make) 27.4.1.7 Striker HI- Speed , 400 mm sweep Usha make) / Wind flow with plastic blade 400 mm sweep Crompton make). [ WF ]item17112Each
172172LUMINAIRIES : Supplying, installation, testing and Commission of the following indoor CFL/Fluorescent luminaries complete with all accessories such as ballast, starter etc. directly on wall / ceiling including connection cable, as approved by the Deptt.)with 1.5 sq mm P.V.C. insulated S.C.copper conductor as required and as directed by the department. Striplite luminaries complete with VPIT copper ballast/ Electronic ballast and decorative end cap and 1 X 36 / 40 watt Fluorescent tube.(Crompton Greaves make) Model- DSG1114LDB CROMGOLD / DSG1114LDBN CROM GOLD NEW / DSG1314EB CG GOLD / DSG 1414EB PLANET GOLD with Super Saver / Super Brite Lamp. Or equivalent (Equivalent will be selected by the deptt considering the mother items rate) PHILIPS/ WIPRO/ BAJAJ/ Havells/ HPL/ SOLAR/ JAQUAR make. [FL]item17220Each
173173Supplying with fitting fixing of CFL/Fluorescent luminaries complete with all accessories such as ballast, starter etc. directly on wall / ceiling including connection as approved by the Deptt.)with 1.5 sq mm P.V.C. insulated S.C. copper conductor as required and as directed by the department. Sleek Box type luminaries complete with Electronic ballast and plastic holder brackets with 1 X 36 / 40 watt Fluorescent tube.(Crompton Greaves make) Model- DJB 1314LDB50 / DJBN1314EB CROMTEK with Super Saver / Super Brite Lamp or equivalent (Equivalent will be selected by the deptt considering the mother items rate) PHILIPS/ WIPRO/ BAJAJ/ Havells/ HPL/ SOLAR/ JAQUAR make. [TL]item1739Each
174174Supplying, installation, testing and Commission of the following indoor Decorative recessed typed mirror optics down lighter luminaries complete with all accessories such as ballast, starter etc. In the false ceiling type Armstrong /Gypsum or similar ceiling mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department 15W, BBS 170 1 X DLED 5000 PSU-WH Phillip make GREEN LED recessed mounted down lighter with latest LED technology. Or equivalent (Equivalent will be selected by the deptt considering the mother items rate) (equivalent WIPRO/ JAQUAR make). [DL]item17434Each
175175Supplying, installation, testing and Commission of the following indoor CFL/Fluorescent luminaries complete with all accessories such as ballast, starter etc. directly on wall / ceiling including connection cable, as approved by the Deptt.)with 1.5 sq mm P.V.C. insulated S.C.copper conductor as required and as directed by the department. Compact CFL luminaries complete with Serrated diffuser & Decorative coloured end caps and Electronic ballast with 1 X 11 W CFL (Crompton Greaves make Model- TLN11/ W MINI MIRRORLITE or equivalent (Equivalent will be selected by the deptt considering the mother items rate) (equivalent PHILIPS/ WIPRO/ BAJAJ/ Havells/ HPL/ SOLAR/ JAQUAR make). [ML]item1754Each
176176Supplying, installation, testing and commissioning of the following CFL/Fluorescent luminaries complete with all accessories such as ballast, starter etc in the ceiling including supplying ball and socket arrangement suspension down rod of 19 mm dia H.G conduit of required length max 0.75 cm including making necessary connection cable, as approved by the Deptt.)with 1.5 sq. mm PVC insulated single core copper conductor as reqd. and as directed by the Deptt. WVF 82228 SGA 2 x 28 W FTL T5) WIPRO FLOAT make Surface / Suspension mounted with Micro Prismatic diffuser with FTL T5) Lamp. or equivalent (Equivalent will be selected by the deptt considering the mother items rate) (equivalent PHILIPS/ JAQUAR make). [DTL]item1764Each
177177Supplying, installation, testing and Commission of the following indoor Decorative recessed typed mirror optics luminaries of T5 complete with all accessories such as ballast, starter etc. In the false ceiling type Armstrong /Gypsum or similar ceiling mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department WVF 53414 SGW 4 x 14 W FTL T5) Recess mounted indirect- direct luminaries with High Efficiency Translucence (HET) Technology suitable for FTL T5) Lamps. Or equivalent (Equivalent will be selected by the deptt considering the mother items rate) (equivalent PHILIPS/ JAQUAR make). [CLS]item1776Each
178178NON-SCHEDULE ITEMS LT PANEL - COMMON BUILDING : Supplying and installation of metal enclosed wall/floor mounted front operated cubical type switch gear panel suitable for indoor installation conforming to IS: 8623 (Part I & II). Panel should be made of sheet steel and thickness not less than 2mm and structural steel having light section. The panel shall be completely dust tight and vermin proof and shall be painted with anti corrosive and anti condensation type two coats of primer and two coats of paint. All wiring shall be PVC insulated and PVC sheathed of 1100 volt grade of required size. The panel should have provision of entry of cable at the bottom and also provision of out going feeders from the bottom of the panel. The panel shall be incorporated with double busbar system. The bus bar shall be of high quality copper of uniform cross section. The panel shall consist of the following items (viz. Voltmeter, Ammeter, CT, indicating lamps, selector switch etc.) connected as per drawing and shall be flush mounted on the front of the panel. Incommer: (a) 160A 4P MCCB, 36 KA Electronic Release – 2 Nos. (b) Digital Ammeter - 2 Nos.(c) Digital Voltmeter - 2 Nos.(d) CT 160/5 & -2 Sets. (e) Switch Fuse Unit - 6 Nos. (f) Selector Switch - 2 Nos (g) LED Indicating Lamp 2 Sets (h) Bus-Bars: 320 A TPN electrolytic Copper Bus Bar of uniform cross-section (400mmx5mm) – 1 set Outgoing: (i) 40A DP MCB - 6 Nos (j) 40A 4P MCB -4 Nos. (k) 160A 4P ON LOAD Change Over Switch – 1 No.item1781Set
179179Supply, Installation antistatic rubber mat suitable for 1.1 KV Voltage gradeitem1792Sq.M
180180Supply, Fitting Fixing of Shock Treatment Chartitem1804Each
181181EARTHING Supply, installation & testing of G.I. earth station with perforated 40 mm dia and 4.50 Metre long heady duty G.I. pipe with necessary 40 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .item1812Each
182182Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt.item1822Each
183183Supplying & laying of 6 SWG G.I.. earth drawn through 15 mm dia. Medium quality G.I. pipe from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.item18380Metre.
184184Supplying & laying of following 25mmX5MM size G.I. strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of G.I. nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt.item18440Metre.
185185Supplying and fixing of 40 mm dia hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.) for street light water tight bracket including bending to shape and Wiring with 1.5 sq. mm size aluminium weather proof PVC cable etc.. as required.item1854Each
186186MCB IN-comer SPN DB : Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. 15.2.1 ABB, Schneider MG, legrand, Hager make) 15.2.1.3 8 way SPN Double Dooritem1861Each
187187Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.1.2 C Series (Schneider MG, legrand, Hager make) 16.1.2.1 6 to 32Aitem1874Each
188188Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.3.2 C Series (ABB, Schneider MG, legrand, Hager make) 16.3.1.1 6 to 32Aitem1881Each
189189STREET LIGHT LUMINAIRES AND PANEL BOARD : Supplying with fitting & fixing of the following integral type street light luminaries complete and consisting of single piece integral epoxy gray powder coated dia cast aluminium housing gasket, pot optic reflector, cast aluminium frame from heat resistance toughened clear glass cover and accessories such as Condenser, lamp Holder, Ballast, lamp etc. in the existing pole including making necessary connection as approved by the Deptt.)with 2× 2.50 sq.mm F.R. multistrand and P.V.C. insulated single core copper cable as specified and directed by the department. 25.2.7 Philips make) Cat No.SGP 325 1xHPITP250W FG Colour For Lamp 1xHPITP250W (IP65) / Crompton Greaves make) SSGN1125H For lamp 1xMH250W.item1894Each
190190U. G. CABLE AND CABLE WORKS : Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make). 32.1.2 3 Core A2XWY A2XFY 32.1.2.1 4.00 Sq.mm 3 Core armoured U.G. cableitem190100Metre
19119132.1.3 3 & 1/2 Core A2XFY32.1.3.6 120.00 Sq. mm.3 & 1/2 Core armoured U.G. cableitem19180Metre
192192Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch, through medium duty G.I. pipe (Tata/ Nezone make or equivalent as approved by the Deptt) bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) 32.5.2 Core - 3 A2XWY A2XFY 32.5.2.1 4.00 Sq.mm 3 Core U.G. cable in 25mm dia medium duty G.I. pipeitem19220Metre
19319332.5.3 Core - 3 & 1/2 A2XWY A2XFY 32.5.3.6 120.00 Sq.mm 3&1/2 Core U.G. cable in 65 mm dia medium duty hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.)item19310Metre
194194Supplying including installation of cast iron cable marker as specified and directed by the deptt.item1947Each
195195CABLE KITS Supply including fitting and fixing of 1.1 KV PVC/XLPE cable INDOOR/OUTDOOR end termination Kits (Raychem RPG make) HEAT SHRINK TYPE including all accessories for the following sizes including testing and commissioning as specified and directed by the Deptt. 34.28.3 70-150 Sq.mm., 3/ 3.5/ 4 Core cable.item1951Each/Set
196196OVER HEAD LINE Supplying and fitting fixing of H.T. danger plate complete as required and as directed by the department.item1962Each
197197Supplying including installation, connection as approved by the Deptt., testing and commissioning of SUBMERSIBLE PUMP SET 3 (Three Phase) with steel cable rope and submersible cable complete as directed and specified by the deptt. 39.7.6 Three phase Submersible motor pump set (Texmo / Crompton Greaves/ Aquatic/ CRI/ V-Guar suitable for 100 mm bore well and above. 5 HP STAGE 14 to 50 with MCB controlled Submersible motor pump set control panel.item1971Each
198198Supplying with fitting and fixing sheet steel cable junction box of size 40cm x 20cm x 15 cm made of 16 SWG thick MS Sheet with provision for hinge door and panel locking arrangement complete painted with 2 coats of metal primer and 2 coats of enamelled gloss paint of approved brand and manufacture to give an even shape including cleaning surface to remove of all dirt, dust and other foreign matter, the box is to be fitted on the bottom section of pole with minimum 165 mm dia 25 mm x 5mm size flat iron pole clamp complete with making necessary connection as directed consisting of the following electrical items. (a) 12mm x 2mm x 15 cm long, 2 strip copper Bus Bar - 1 set (b) 6-32 Amp \"L\" series DP MCB - 1 No. (c) 6 amp \"L\" series SP MCB as outgoing - 3 Nos.item1982Each
199199Supply, Fitting Fixing of Shock Treatment Chartitem1992Each
200200Supplying including installation, testing and commissioning of Hi-Wall 4 Star Rating Non ducted Split type of the following capacity with cordless Remote complete with indoor & outdoor Unit,copper pipe & electrical connection as approved by the department upto 5.00M between the room unit and the out door unit as directed by the department. 1.5 Ton Capacity Blue star make model 4WAE181 YAitem2007Each
201201Supplying including installation Voltage Stabilizer of the following specification complete including making necessary connection as approved , specified and directed by the department ( Skyland/VeeDee/V Guard/Vertex/Indo/Venus make) 4.0KVA Automatic input 90-280V output 200-240 Vitem2017Each
202202Supply with fitting & fixing of angle iron framing made of 50mm x 50mm x 5mm size angle iron for accomodation of 1.0T to 2.0Ton window / split AC machineitem2027Each
203203Supplying with fitting and fixing Single Phase D. O. L Starter of the following specification complete including making necessary connection as specified and directed by the deptt. (a) Overload Relay Range 3.8 - 6.0 Amps for 2.2 KWitem2037Each
204204Furniture: Supplying fitting fixing maple wood finish ply top with malamine finish paint ,Waterproof ply framed conference table to seat 25 persons of size 9000mm x 2400mm as per approved colour and with the base structure with 19 mm BWP ply with laminated top as per approved colour and design.item2041Each
205205Supplying fitting fixing conference chair as per enclosed design inclusive of GST. Model : ASTRO MB Make : Featherliteitem20524Each
206206Supplying fitting fixing Additional back up chair as per enclosed design inclusive of GST Model : CONTACT PROJECT MBGS FXD ARMS Make : Featherliteitem20630Each
207207Supplying fitting fixing Chairperson's chair as per enclosed design inclusive of GST. Model : AMAZE MB ML ADJ ARMS Make : Featherliteitem2071Each

AI Tender Summary

OUR REF NO 22825054
AUTHORITY Government Departments
TENDER VALUE 1.03 Crore
LAST DATE 20-12-2019
Authority
Authority Name Assam Industrial Infrastructure Development Copr
Work Description Construction Of Common Building For Conference Hall Bank And Modern Canteen At Igc Chaygaon Chatabari Under Upgradation Of Igc Chaygaon Project
Basic Detail
Tender No AIIDC/2049/2019/22787 date 7/12/19
Bidding Type Tender
Location
City IGC Chaigaon
State Assam
Key Dates
Publish Date 10 Dec 2019
Submission Date 20 Dec 2019
Open Date 20 Dec 2019
Finance
Tender Value 1.03 Crore
Tender Fee 3000
EMD 2.06 Lakhs
Exemption Not Available
Document List
Tendernotice_1.pdf
687EDF34-8A16-4CEF-B677-88AB26902516.html
BOQ_23209.xls
BIDDOCUMENT.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Dec 10, 2019
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 20, 2019
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Dec 20, 2019

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

html

687EDF34-8A16-4CEF-B677-88AB26902516.html

xls

BOQ_23209.xls

pdf

BIDDOCUMENT.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender