| 1 | 1 | LALAM BRIDGE | BI01010001010000000000000515BI0100001113 | | |
|---|
| 2 | 1.01 | 2.2 : Clearing grass and removal of rubbish up to a distance of 50 metres outside the periphery of the areaClearing grass and removal of rubbish up to a distance of 50 metres outside the periphery of the area | BI01010001010000000000000515BI0100001114 | 0.006 | Hecter |
|---|
| 3 | 1.02 | od9778/2019_2020 : Engaging man mazdoor for cleaning and accumulated earth, wastes etc complete | BI01010001010000000000000515BI0100001115 | 40 | each |
|---|
| 4 | 1.03 | 13.5.F.P.2 : Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications <br>\n RCC Grade M25 - With Batching Plant, Transit Mixer and Concrete Pump - Height upto 5m <br>Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications RCC Grade M25 - With Batching Plant, Transit Mixer and Concrete Pump - Height upto 5m | BI01010001010000000000000515BI0100001116 | 7.75 | cum |
|---|
| 5 | 1.04 | 13.6 : Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and Technical SpecificationsSupplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and Technical Specifications | BI01010001010000000000000515BI0100001117 | 0.543 | MT |
|---|
| 6 | 1.05 | od9781/2019_2020 : BAILING OUT WATER 5 TO 10 HP ENGINE AND PUMPS UP TO INCLUDING CONVEYANCE TO SITE AND ERECTION COST OF FUELS ,LUBRICATING OIL, ERECTION CHARGE PAY OF CHARGE ETC | BI01010001010000000000000515BI0100001118 | 80 | hour |
|---|
| 7 | 1.06 | od9782/2019_2020 : Providing and puttingup ring bund with bottom width of 2.00 m and top width of 1.00 m and height 2.00 m (Avg) packing with earth filled bags for preventing erosion of loose and slushy soil including earth and water and maintaining the wall till the formation of superstructure and dismantling the structure after completion of the work including all cost of materials labour charges etc complete as directed by the departmental officers at site. | BI01010001010000000000000515BI0100001119 | 382 | metre |
|---|
| 8 | 1.07 | 12.1.1 : Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.<br>\nOrdinary soil - Depth upto 3 m - Manual MeansEarth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.Ordinary soil - Depth upto 3 m - Manual Means | BI01010001010000000000000515BI0100001120 | 29.136 | cum |
|---|
| 9 | 1.08 | 12.8.A.1 : Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications. <br>\nPCC Grade M15 <br>Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications. PCC Grade M15 | BI01010001010000000000000515BI0100001121 | 6.773 | cum |
|---|
| 10 | 1.09 | od9784/2019_2020 : Dry rubble masonry for foundation and superstructure including all cost as per design and drawings | BI01010001010000000000000515BI0100001122 | 120.324 | cum |
|---|
| 11 | 1.1 | 13.5.E.q.2 : Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications <br>\n RCC Grade M20 - With Batching Plant, Transit Mixer and Concrete Pump - Height 5m to 10m <br>Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications RCC Grade M20 - With Batching Plant, Transit Mixer and Concrete Pump - Height 5m to 10m | BI01010001010000000000000515BI0100001123 | 3.713 | cum |
|---|
| 12 | 1.11 | 14.2 : Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specificationsSupplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications | BI01010001010000000000000515BI0100001124 | 0.186 | MT |
|---|
| 13 | 1.12 | 13.5.B : Plain/Reinforced Cement Concrete in sub-structure complete as per drawing and Technical Specifications <br>\nPCC Grade M20 - Height upto 5mPlain/Reinforced Cement Concrete in sub-structure complete as per drawing and Technical Specifications PCC Grade M20 - Height upto 5m | BI01010001010000000000000515BI0100001125 | 0.75 | cum |
|---|
| 14 | 1.13 | 13.2 : Pointing with cement mortar (1:3) on brick work in substructure as per Technical SpecificationsPointing with cement mortar (1:3) on brick work in substructure as per Technical Specifications | BI01010001010000000000000515BI0100001126 | 105 | sqm |
|---|
| 15 | 1.14 | od9786/2019_2020 : Providing and fixing double scaffolding system (cup lock type) on the exterior side, upto 6m height made with 40 mm dia. M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staricase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required location with essential safety features for the workmen etc. complete as per directions and approval of Engineer- in Charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. Note:- This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done . | BI01010001010000000000000515BI0100001127 | 120 | sqm |
|---|
| 16 | 1.15 | 13.8 : Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V : 20H towards drawing foce.Complete as per drawing and Technical SpecificationsProviding weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V : 20H towards drawing foce.Complete as per drawing and Technical Specifications | BI01010001010000000000000515BI0100001128 | 20 | no |
|---|