| Name of Work: REPAIR/ MAINTENANCE OF VARIOUS SEWAGE INSTALLATIONS AND OTHER CONNECTED WORKS AT AF STATION BAMRAULI | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Taking out aerator motor pumping set 10 HP capacity from existing foundation after disconnecting of elect connection & necessary pipe line by opening nut bolts etc and dismantling the aerator motor pumping set for carrying out the repairs, reassembling the same including replacement of wornout nuts, bolts and washers including derusting, descaling, servicing, oiling, greasing ,reinstalling, testing and making good all Sewage line and electric connections to ensure proper functioning entire unit and commissioning complete all as directed. \nNote :- The unit rate includes the cost of nuts, bolts, washers and all material required for overhauling , derusting, descaling etc & no extra payment will be made. Spare parts shall be measured and paid separately under relevant items | 2 | Each | |
| 2 | 2 | Supply only Aerator Impeller suitable for aerator motor pumping set of capacity 10 HP complete. | 2 | Each | |
| 3 | 3 | Supply only Base Plate suitable for aerator motor pumping set of capacity 10 HP complete. \nNote:- The cost for fixing of item Nos 2 and 4 shall be deemed to be included in the unit rate quoted against item here in before. | 2 | Each | |
| 4 | 4 | M&L for rewinding to aerator motor of capacity 10 HP of any make with supper enamelled copper winding wire of existing size and quantity including insulating materials ie varnish , sleeves etcincluding dismantling for repair and commissioning after repair complete all as directed. | 2 | Each | |
| 5 | 5 | Taking out non clog submesible pump set from existing shoak well after disconnecting of necessary pipe line by opening nut bolts etc and dismantling the pump of any make for carrying out the repairs, reassembling the same including replacement of wornout nuts,bolts and washers etc reinstalling,testing and making good all water line and electric connections to ensure proper functioning entire unit and commisioning complete all as directed by Engr-in-charge for the following capacity of pump sets :- \nNote :- spare parts shall be measured and paid separately under relevant items | |||
| 6 | 5.01 | (a) Non clog submesible pump set 0.37 KW | 2 | Each | |
| 7 | 5.02 | (b) Non clog submesible pump set 1.5 HP | 2 | Each | |
| 8 | 5.03 | (c) Non clog submesible pump set 4 HP | 4 | Each | |
| 9 | 5.04 | (d) Non clog submesible pump set 5 HP | 3 | Each | |
| 10 | 5.05 | (e) Non clog submesible pump set 15 HP | 4 | Each | |
| 11 | 6 | M&L for rewinding to undermentioned non clog submesible pump set of any make with supper enamelled copper winding wire of existing size and quantity including insulating materials ie varnish , sleeves etc complete including dismantling and commissioning after rewinding all as directed for following capacity:- | |||
| 12 | 6.01 | (a) Non clog submesible pump set 0.37 KW | 2 | Each | |
| 13 | 6.02 | (b) Non clog submesible pump set 1.5 HP | 2 | Each | |
| 14 | 6.03 | (c) Non clog submesible pump set4 HP | 4 | Each | |
| 15 | 6.04 | (d) Non clog submesible pump set 5 HP | 3 | Each | |
| 16 | 6.05 | (e) Non clog submesible pump set 15 HP | 4 | Each | |
| 17 | 7 | Supply only the following spare parts of non clog submersible pump set :- | |||
| 18 | 7.01 | (a) O ring | 8 | Each | |
| 19 | 7.02 | (b) Bearing | 5 | Each | |
| 20 | 7.03 | (c) Allen screw | 8 | Each | |
| 21 | 7.04 | (d) Oil plug | 5 | Each | |
| 22 | 7.05 | (e) Screwed adjustener | 6 | Each | |
| 23 | 7.06 | (f) Impeller nut cover | 6 | Each | |
| 24 | 7.07 | (g) Hex Bolt | 13 | Each | |
| 25 | 7.08 | (h) Hexagon nuts | 15 | Each | |
| 26 | 7.09 | (j) Locking Washer | 8 | Each | |
| 27 | 7.1 | (k) Cable cap | 6 | Each | |
| 28 | 7.11 | (l) Upper seal. | 8 | Each | |
| 29 | 7.12 | (m) Lower seal. | 8 | Each | |
| 30 | 7.13 | (n) Rertaining washer | 5 | Each | |
| 31 | 7.14 | (o) Oil seal 4HP non clog submersible pump | 2 | Each | |
| 32 | 7.15 | (p) Oil seal 5HP non clog submersible pump | 1 | Each | |
| 33 | 7.16 | (q) Oil seal 10HP non clog submersible pump | 2 | Each | |
| 34 | 7.17 | (r) Oil seal 15HP non clog submersible pump\n\nNote for Srl item 07 (a) to (r) :- The cost for fixing of item Nos 07 (a) to (r) shall be deemed to be included in the unit rate quoted against items here in before. | 2 | Each | |
| 35 | 8 | M&L Gear oil suitable for aerator motor/pumping set complete all as directed. Make Veedol/Power gear/MAK | 205 | Ltr | |
| 36 | 9 | Labour for taking out sludge from sand filter bed and transportation to depositing the existing plateform , cleaning of sand filter complete in side and out side removing of unwanted vegetation in sand filter complete as directed. | 200 | Cum | |
| 37 | 10 | Labour for taking out sludge from existing plateform and transportation to depositing where directed by Engr-in-Charge, cleaning of Plateform complete, removing of unwanted vegetation in plateform complete as directed. | 200 | Cum | |
| 38 | 11 | Material and labour for clean dry sand (as specified for filter bed) laid in filter bed for bedding, complete all as specified directed. | 60 | Cum | |
| 39 | 12 | Material & Labour for pumping out sewage water mixed with sludge from aeration tank containing two tanks each of size 30 Mtrs x15 Mtrsx3 Mtr deep , detwatering of sludge from the sump by the help of pump, complete all as specified and directed. \nNote :- For the purpose of measurement depth of contents (Water/Sludge) shall be measured not exceeding 2.5 Mtr ). | 2250 | Kilo Litre | |
| 40 | 13 | All as per item No 12 above but from clarifier tank of 16 Mtr dia and 3 Mtr depth complete all as spcfieid and directed. | 600 | Kilo Litre | |
| 41 | 14 | Removing sedimented sludge by excavating not exceeding 75 cm deep (average) and getting out from aeration tank for removing out side of MOD and deposited where directed at a place allotted by local muncial/ corporation including spreading of sufficient bleachig powder over the sluge to take all precuative health hazzored complete all as specified and directed. | 700 | Cum | |
| 42 | 15 | All as per item No 14 above but sump well 6 Nos sump well each of dia not less than 3 Mtr and average depth of excavation n.exc 90cm complete all as specified and directed. | 120 | Cum | |
| 43 | 16 | Material and labour for opening choked line of sump well upto a depth of 10mtr from ground level with necessary tool and plant to make through the sludge from one system to another complete all as specified and directed. Note: 1. The T&P will be given by the contractor. 2. The contractor should be fully responsible for safety of the labourer engaged during the said work. | 10 | Job | |
| 44 | 17 | Excavation in trenches in any type of soil by not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth below ground level for foundation of poles / stays / cable and getting out complete all as directed. | 8 | Cum | |
| 45 | 18 | Returning , filling in, any type of soil and spreading in layers not exceeding 25cm thick each layer including watering & well ramming complete all as directed. | 4.5 | Cum | |
| 46 | 19 | Removal of surplus soil to a distance not exceedisng 50 mtr & depositing where directed at a level not exceeding 1.5 mtrs above the stating point compete all as directed. | 3.5 | Cum | |
| 47 | 20 | Supply and laying old size as class `B' bricks, laid flat in trences over the cable along the length of cable and bricks perpendicular to the direction of cable adjacent / abutting each other complete all as directed. | 313 | Each | |
| 48 | 21 | Material and labour for sand cushioning with layer of sand 8cm thick before laying of cable and 15cm after laying of cable in trenches complete all as directeld and sand cover to under ground cable complete all as directed. | 2.8 | Cum | |
| 49 | 22 | Supply, laying, testing and commissioning of LT UG cable XLPE insulated PVC sheathed galvanized steel strip armoured electric power cable with stranded aluminium conductor 1100 volts grade 35 sq mm 3.5 core confirming to IS:7098 (Part-I), suitable for earthed system, laid in duct/trench/along pole/wall etc including nuts, bolts, washers, saddles & screws etc and making connection, complete all as directed. \nNote : 1. The cost of AL thimbles/lugs and cable gland etc is included in quoted rate and no extra payment will be made for it. \n2. Excavation, earth work, sand cushioning and brick protection will be measured and paid seperately under respective items. | 50 | RM | |
| 50 | 23 | S&F of GI pipe of 40 mm nominal dia bore light grade fixed to poles with clamps nuts, bolts and washers or laid under road crossing or fixed to wall including painting with two coats of aluminium paint over a coat of red oxide paint complete all as directed. \nNote : The cost of MS clamp, nut, bolt, washer and GI fittings etc shall be inclusive in the item rate. | 6 | RM | |
| 51 | 24 | Supply & fixing or fabricated of Mild steel frame made of angle iron 40x40x6mm glow sign boards on flex sheet of 1mm thick of size 6550mm x 910mm duly indicating the name of installation and logo of MES with suitable redium stencil and necessary items for fixing on roof /wall grouting/ PCC work complete all as directed.\nNote:Background colour sky blue and matter or size of stencil as direction. | 1 | Each | |
| 52 | 25 | Supply and fixing in replacement of MCCB, 415 volts, four pole of capacity 16 Amps, 16KA, ICS = 100% ICU, with Thermal- Magnetic Release, including spreader terminals, phase barriers, thimbles of suitable size etc and making electric connections and taking down old unserviceable MCCB, complete all as directed. \nMake: Legrand/Siemens/Schneider | 2 | Each | |
| 53 | 26 | All as per items No. 25 here-in-before but 40 Amp capacity | 4 | Each | |
| 54 | 27 | All as per items No. 25 here-in-before but 100 Amp, 36 KA capacity | 3 | Each | |
| 55 | 28 | All as per items No. 25 here-in-before but 200 Amp, 36 KA capacity | 1 | Each | |
| 56 | 29 | Supply and fixing in replacement of On load change over switch disconnector of 160 Amps capacity, front handle operated, four pole type, sheet steel enclosure type to fixed on wall/ panel, including all accessories etc, complete all as directed. | 1 | Each | |
| 57 | 30 | Supply and fixing in replacement of digital ammeter of size 96mm x 96mm, 3 phase, 5A, class 1.0,CT operated with inbuilt selector switch with and including taking down of unserviceable ammeter and making all electric connection complete all as directed. \nMake: HPL/Conserve/L&T/Neptune | 8 | Each | |
| 58 | 31 | Supply and fixing in replacement of digital Voltmeter,of size 96mmx96mm Three phase, class 1.0, with in built selector switch,with and including taking down of unserviceable voltmeter and making all electric connection complete all as directed. Make: HPL/Conserve/L&T/Neptune | 8 | Each | |
| 59 | 32 | S&F in replacement of LED type indicator lamp of red/blue/green colour for phase indication with and including taking down of unserviceable indicator and making all electric connection, in existing panel, complete all as directed. | 20 | Each | |
| 60 | 33 | S&F in replacement non clog submersible pump controller in sheet enclosure Type MU-G6 DOL for three phase motor 415 volts, 50 HZ, 5 HP, 6-10 Amps relay range including suitable size LT panel, outdoor type, for mounting/fixing the pump controller, cubical compartmentalised of 2mm thick CRCA sheet powder coated front door openable with angle iron 45x45x5 mm frame bottom of the panel board, grouted by using PCC foundation 1:2:4 type C1 with 20 mm graded stone aggregate, thimbling and cable entry boxes with cable gland inculding painting with two coat of powder coated painting over a coat of red oxide primer complete all specified and directed. Make Cat Part No. SS97756COVO of L&T or equivalent in Legrand | 4 | Each | |
| 61 | 34 | S&F in replacement non clog submersible pump controller in sheet enclosure Type MU-G20 FASD for three phase motor 415 volts, 50 HZ, 15 HP, 11KW, 9-14 Amps relay range including suitable size LT panel, outdoor type, for mounting/fixing the pump controller, cubical compart mentalised of 2mm thick CRCA sheet powder coated front door openable with angle iron 45x45x5 mm frame bottom of the panel board, grouted by using PCC foundation 1:2:4 type C1 with 20 mm graded stone aggregate, thimbling and cable entry boxes with cable gland inculding painting with two coat of powder coated painting over a coat of red oxide primer complete all specified and directed. \nMake Cat Part No SS95984DOAO of L&T or equivalent in Legrand | 2 | Each | |
| 62 | 35 | Material & labour for cleaning, scrubbing and preparation of old painted surface of LT panel inside and outside complete and painting with one coat of synthetic enamel paint over two coat of red oxide primer, complete all as specified and directed. \nNote: Necessary electric shutdown to the panel will be given before the work. | 50 | Sqm | |
| 63 | 36 | Material & labour for welding LT panel i.e. door front/ rear, hinges, compartment etc and making good the existing surface after necessary welding complete all as specified and directed. \nNote: 1. Necessary electric shutdown to the panel will be given before the work. \n2. Painting work should be measured seperately as schedule of work. | 5 | Each Job | |
| 64 | 37 | M&L for Cleaning the area as directed by cutting grasses, bushes of any size etc and making neat and clean the area all as directed. | 1000 | Sqm | |
| 65 | 38 | Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. |
AI Tender Summary
Tender Timeline
Dec 03, 2019
11:30 IST
Tender Published
Tender notice published.
CompletedDec 24, 2019
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedDec 26, 2019
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender