Sales : +91-777 804 8217
| Name of Work: ADDITION/ALTERATION TO SIGNAL SECTION AT 23 ED AF STN AVADI UNDER GE AVADI | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Unit | |
| 1 | 1 | Surface excavation not exceeding 30cm deep and averaging 15cm deep in hard/dense soil complete all as specified and as directed. | 205 | SQM | |
| 2 | 2 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in soft / loose soil complete all as specified and as directed. | 117.6 | CUM | |
| 3 | 3 | Treating the backfill in contact with foundation at the rate of 7.5 litres of\nemulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) | 29 | SQM | |
| 4 | 4 | M & L for Sand filling under floors or in foundations in layers not exceeding 15cm thick each layer including spreading watering and ramming complete all as specified and as directed. | 3 | CUM | |
| 5 | 5 | M&L for cement concrete type D2, 1:4:8 ( using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed | 4.1 | CUM | |
| 6 | 6 | M&L for cement concrete type C2, 1:3:6 ( using 40mm graded stone aggregate) as in surface drain and channel complete all as specified and as directed | 1.2 | CUM | |
| 7 | 7 | M&L Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed. | 90 | SQM | |
| 8 | 8 | M&L for RCC M-30 design mix as in foundation including rafts, footings, foundation beams, plinth beams, bases for columns etc basement slabs under reamed piles and mass concrete complete all as specified and as directed. Note:- Reinforcement shall be measured and paid for separately. | 17.5 | CUM | |
| 9 | 9 | M&L for form work to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed. | 76 | SQM | |
| 10 | 10 | M&L for RCC , M-30 design mix as in columns, pillars, piers, post and struts complete all as specified and as directed. \nNote:- Reinforcement shall be measured and paid for separately.\n | 6.9 | CUM | |
| 11 | 11 | M&L for form work to sides and soffits of floor or roof beams beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports over hangs, etc also splays between floor and beams etc rough finished surfaces of concrete complete all as specified and directed. | 73 | SQM | |
| 12 | 12 | M&L for RCC , M-30 design mix as in lintels complete all as specified and as directed\nNote:- Reinforcement shall be measured and paid for separately.\n | 3.3 | CUM | |
| 13 | 13 | M &L form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200mm thick (Horizontal or Sloping) complete all as specified and directed. | 180 | SQM | |
| 14 | 14 | M&L for RCC, M-30 design mix as slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directedNote:- Reinforcement shall be measured and paid for seperately\n | 31.5 | CUM | |
| 15 | 15 | M &L form work to facias complete all as specified and directed. | 13 | SQM | |
| 16 | 16 | M&L for RCC, M-30 design mix as in chajja, facia and the like complete all as specified and as directedNote:- Reinforcement shall be measured and paid for seperately\n | 1.5 | CUM | |
| 17 | 17 | M&L for 10mm dia and over TMT bars as in reinforcement cut to length bent to shape required including cranking hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia (or) securing with clips quality conforming to Fe 500D complete all as specified and directed. | 3740 | KG | |
| 18 | 18 | S&F Mild Steel TMT bars 6 to 8mm dia , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed | 1850 | KG | |
| 19 | 19 | All as per item No 17 above but 5 mm dia and over upto and including 10mm dia in stirrups, spacers and binders quality conforming to Fe-500D complete all as specified and directed. | 1300 | KG | |
| 20 | 20 | S&F mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment of Fe-410-W (Gde-E-250) quality ‘A’ complete all as specified and as directed. | 780 | KG | |
| 21 | 21 | M&L for brickwork with old size fly ash bricks, straight or curved on plan exceeding 6m mean radius, built in CM 1:6 complete all as specified and as directed. | 57 | CUM | |
| 22 | 22 | M&L for brickwork with old size fly ash bricks, straight or curved on plan in any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed. | 33 | SQM | |
| 23 | 23 | Returning filling in soil including spreading levelling watering well ramming in layers not exceeding 25 cm each complete all as specified and as directed. | 92.3 | CUM | |
| 24 | 24 | M&L for rendering 15mm thick in two coats viz first coat 10mm thick in CM 1:4 and finishing coat 5 mm thick in CM 1:4 on other than fair faces of stone/brick/concrete surfaces mixed with water proofing compound and finished even and fair complete all as specified and as directed. \nNote : Supply only water proofing compound will be measured and paid separately.\n\n | 461.5 | SQM | |
| 25 | 25 | M&L for rendering 10 mm thick in cement mortar 1:6 on fair faces of brick wall or concrete surfaces, finished even and smooth, without using extra cement complete all as specified and as directed. | 430 | SQM | |
| 26 | 26 | M&L for rendering in CM 1:3, 5mm thick as in ceiling on fair faces of concrete surfaces and finishing the surfaces even and smooth complete all as specified and directed. | 120 | SQM | |
| 27 | 27 | M&L for preparation of newly plastered wall surfaces of wall and applying two coats of oil bound distemper over a coat of alkali resistant primer over 2 to 3 mm thick wall care putty complete all as specified and as directed. | 315 | SQM | |
| 28 | 28 | M&L for applying two coats of weather proof paint (APEX of approved shade) over a coat of white primer over 2 to 3 mm thick wall care putty, including preparation of newly plastered surface all as directed by Engr in Charge. | 220 | SQM | |
| 29 | 29 | M & L for applying three coats of white wash as in ceiling including preparation of newly plastered ceiling surfaces complete all as specified and directed. | 120 | SQM | |
| 30 | 30 | M & L for moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick spread, levelled and rammed including watering complete all as specified and as directed. | 32 | CUM | |
| 31 | 31 | Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as pecified and as directed. | 122 | SQM | |
| 32 | 32 | M&L for PCC 1:5:10, type E2, 75mm thick (using 40mm graded stone aggregate) as in sub base under flooring complete all as specified and directed. | 122 | SQM | |
| 33 | 33 | M&L PCC 1:2:4 as in floors 25mm thick type B0 using 12.5mm graded stone aggregate under layer for laying floor finishes complete all as specified and as directed. | 122 | SQM | |
| 34 | 34 | M&L for double charged vitrified tiles f size 600x600x10mm thick in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including backing coat of 15mm thick in CM 1:4 all as specified and as directed. | 87 | SQM | |
| 35 | 35 | M&L for non skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc. set and jointed in neat cement slurry and pointed i white or coloured cement to match laid over and including 15mm thick cement screed bed in CM 1:4 all as specified and as directed. | 17 | SQM | |
| 36 | 36 | S&F glazed ceramic coloured tiles of 300 x 200 x 7mm thick tiles on vertical surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match over rendering in CM 1 :4, 10mm thick on fair faces of brick/concrete wall surfaces all as specified and as directed. | 128 | SQM | |
| 37 | 37 | M & L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade laid over and including 50mm thick sand cushion and filling the joints with sand complete all as specified and as directed.\n | 12 | SQM | |
| 38 | 38 | Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed. | 46 | SQM | |
| 39 | 39 | M&L for broken stones or boulders as in hardcore of gauge exceeding 63mm but not exceeding 100mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and as directed.\n | 6.1 | CUM | |
| 40 | 40 | M&L for 75mm thick cement concrete type C2 1:3:6 (using 40mm graded stone aggregate) as in plinth protection, finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed. | 46 | SQM | |
| 41 | 41 | Forming of construction joints 65mm deep x 10mm wide, filled with sealing compound grade 'A' all as specified and as directed.\n | 3 | TEN\nRM | |
| 42 | 42 | M&L for water proofing treatment to roof slab using APP membrane as under :-\n(a) Prepare roof slab top surface, removal all loose materials (b) provide screed bed of CM 1:4, 10mm thick mixed with WPC as per manufacturer instructions. (WPC will be measured and paid separately). (c) Apply a uniform coat of blown grade bitumen at 1.20 Kg/Sqm conforming to IS 702. (d) APP modified prefabricated membrane mineral finish, 3mm thick and weighing not less than 3.6 Kg/Sqm reinforced with non woven polyester matt black finished torch applications for membrane with 100mm overlap after necessary preparation of surface complete as per manufacturers instructions. (e) Apply a uniform coat of bitumen primer at 0.70 Kg/Sqm. (f) Apply aluminium paint on top at 0.1 Kg/Sqm all as specified and as directed. All the angles, abutments and the drainage outlets shall be sealed with extra care to ensure full bondage.\nNote : The work shall be executed through manufacture’s applicator as approved by GE.\n | 170 | SQM | |
| 43 | 43 | Supply only integral water proofing compound | 55 | KG | |
| 44 | 44 | M & L for Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel xpansion fasteners, 6mm dia hangers with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and as directed.\n | 102 | SQM | |
| 45 | 45 | S & F PVC insulation panels of 10mm thick with EPS stuck to 1mm plain PVC sheet suitably placed in false ceiling grid provided under item No 44 here-in-before complete all as directed.\n | 102 | SQM | |
| 46 | 46 | S&F for solid PVC door frame of size 50 x 47mm made out of 5mm thick plain colour PVC sheet reinforced with 19mm MS square tube of 19 gauge metered out at two corners and joined by inserting two Nos of 150mm long brackets of 15mm x 15mm MS square tube inside the drilling 100mm long MS screws using PVC fastener complete all as specified and as directed.\n | 10 | RM | |
| 47 | 47 | S&F for factory made solid PVC moulded door shutter , 28 to 30mm thick (stiles) with 2, 4 or 6 raised panel design with 2mm thick 3D wood grain moulded PVC sheet polyurethane painted on the front face and 2mm plain coloured PVC sheet on back space with wood free EPS including supply and fixing tower bolts aluminium 150mm size- 2 Nos, PVC hinges of 100mm size -3 Nos and aluminium handle of size 125mm - 2 Nos for each shutter complete all as specified and as directed\n | 4 | SQM | |
| 48 | 48 | M & L for Powder coated aluminium anodised frame for doors, windows, ventilators and partitions etc, with one or more rebates including joining cleat for fixing etc and shall confirm to IS 1868-1996 complete all as specified and directed (Thickness of powder coating not less than 50 micron). | 140 | KG | |
| 49 | 49 | S&F powder coated aluminium door shutters, aluminium section weighing not less than 0.55kg/M for frame including powder coated aluminium joining cleats, glazing clips ruber neoprene packing, handles 2 Nos in each door, hinges, snap beading, screws etc complete all as specified and as directed. Note:- Thickness of powder coating shall not be less than 50 micron. | 12 | SQM | |
| 50 | 50 | M & L for anodised aluminium window and ventilator shutters, sliding type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified | 16 | SQM | |
| 51 | 51 | S&F aluminium wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium staples complete all as specified and as directed. | 16 | SQM | |
| 52 | 52 | S&F aluminium rebated mortice lock vertical type size 100 mm four lever complete all as specified and as directed. | 6 | EACH | |
| 53 | 53 | S&F door closer aluminium body (Die cast) hydraulically regulated designation No 3, universal type suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 Kg and fixed complete all as specified and as directed. | 6 | EACH | |
| 54 | 54 | S&F floor door stopper overall length of cover plate150mm, aluminium alloy body and tongue, anodised with hard drawn steel spring fixed in floor complete all as specified and as directed | 6 | EACH | |
| 55 | 55 | M&L for 9mm thick prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination, fixed with suitable screws complete all as specified and as directed. | 6 | SQM | |
| 56 | 56 | S&F sheet glass 4.8mm thick plain ordinary quality in squares not exceeding 0.50 sqm in each pane and fixed with rubber beading complete all as specified and directed.\n\n | 8 | SQM | |
| 57 | 57 | S&F frosted glass 4.8mm thick ordinary quality in squares not exceeding 0.50 sqm in each pane and fixed with rubber beading complete all as specified and directed.\n\n | 1 | SQM | |
| 58 | 58 | S&F sheet glass 4mm thick plain ordinary quality in squares not exceeding 0.50 sqm in each pane and fixed with rubber beading complete all as specified and directed.\n\n | 10 | SQM | |
| 59 | 59 | S&F framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, frame work of water tanks and similar work conforming to Fe.290, Gde E-165 all as specified and as directed. | 400 | KG | |
| 60 | 60 | M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer on newly steel surfaces of any description, not otherwise described over 10cm width or girth complete all as specified and as directed. | 88 | SQM | |
| 61 | 61 | Supplying and laying 20mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. | 9 | RM | |
| 62 | 62 | Supplying and laying 25mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. | 7 | RM | |
| 63 | 63 | S&F 15mm dia stop valves(concealed type), fancy type chromium plated with long shank complete all as specified and directed. | 1 | EACH | |
| 64 | 64 | S&F 15mm dia stop valves, cast copper alloy, screwed down, high pressure, with crutch of butterfly handle, screwed both ends for iron pipe complete all as specified and directed. | 4 | EACH | |
| 65 | 65 | S&F 20 mm gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe fixed complete all as specified and as directed. | 1 | EACH | |
| 66 | 66 | S&F 15 mm dia bib taps chromium plated fancy type screwed down for iron pipe or for brass ferrule complete all as specified and as directed. | 2 | EACH | |
| 67 | 67 | S&F vitreous china wash down water closet pan (pedestal pattern) white including PVC flushing cistern of 10 lit capacity and flush pipe, health faucet, chromium plated, fancy type with 1m long flexible tube, plastic water closet seat cover black closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device including connection to drain (or outgoing pipe) and to flush pipe anti syphonage pipe etc complete all as specified and as directed. | 2 | EACH | |
| 68 | 68 | S & F vitreous china oval type counter top wash basin white including 32mm waste fittings of brass chromium plated complete all as pecified and as directed. Make CERA, Model No : Cera Oval 1005D or equivalent in Jhonson/parryware | 2 | EACH | |
| 69 | 69 | S&F 18 to 20mm thick granite stone slabs mirror polished of colour and shade as approved by GE, machine cut bedded and jointed with grey cement slurry and pointed in white cement with admixture of pigment to match the shade of granite stone fixed as in steps, jambs, gate pillars (vertical sufaces) window cills, cooking platforms and the like etc fixed over and including 20mm thick backing coat in M 1:3 complete all as specified and as directed. | 36 | SQM | |
| 70 | 70 | S&F PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and as directed. | 4 | EACH | |
| 71 | 71 | S&F pillar taps, chromium plated, fancy type, screwed down, high pressure, with or without lettered ‘HOT’ or ‘COLD’ with long screwed shanks and fly nuts, screwed for 15 mm bore complete all as specified and as directed. | 2 | EACH | |
| 72 | 72 | S&F 600x450mm bevelled edged looking mirror 6mm thick of selected quality glass, mounted on 6 mm thick commercial plywood and with aluminium frame work fitted with chromium plated brass screws and cup washers complete all as specified and directed\n | 2 | EACH | |
| 73 | 73 | S & F Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and as directed. | 40 | RM | |
| 74 | 74 | S&F to tubular towel rail 600mm long between flanges 'D' type brass chromium plated, fixed to wall with brass screws and wooden/plastic cleats complete all as specified and directed. | 2 | EACH | |
| 75 | 75 | S&F soap dish, Vitreous china white of size 160X160X90mm embedded in the wall complete all as specified and as directed. | 2 | EACH | |
| 76 | 76 | S&F 75 mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed. | 4 | EACH | |
| 77 | 77 | S&F 75 mm PVC (SWR) bend any radius complete all as specified and as directed. | 4 | EACH | |
| 78 | 78 | S&F 110 mm PVC (SWR) bend any radius complete all as specified and as directed. | 4 | EACH | |
| 79 | 79 | S&F 110 mm PVC (SWR) WC connector with lip ring complete all as specified and as directed. | 2 | EACH | |
| 80 | 80 | S&F 75mm dia PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and as directed | 2 | EACH | |
| 81 | 81 | S&F 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches complete all as specified and as directed. | 6 | RM | |
| 82 | 82 | S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches complete all as specified and as directed. | 3 | RM | |
| 83 | 83 | S & F rotational moulded polyethylene water storage tanks 1000 Ltr capacity triple layers (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed. | 1 | EACH | |
| 84 | 84 | S&F 20mm dia ball brass valve high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferule and fixed complete all as specified and as directed. | 1 | EACH | |
| 85 | 85 | S & F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and as directed. | 1 | EACH | |
| 86 | 86 | S & F PVC (SWR) 75mm dia nahani trap including setting and jointing with solvent cement complete all as specified and as directed. | 1 | EACH | |
| 87 | 87 | Excavating in post holes (or similar holes) in hard/dense soil each not exceeding 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance not exceeding 50m and making good surface complete all as specified and as directed. | 6 | EACH | |
| 88 | 88 | M&L for cement concrete type C2, 1:3:6 ( using 40mm graded stone aggregate) as in foundation for fixing of bolts complete all as specified and as directed | 2 | CUM | |
| 89 | 89 | M&L for rolled mild steel joist, channels, angles, or tee sections, fixed independently, without connecting plates, etc as Fe-410-W (gde-E-250), Quality 'A' complete all as specified and directed. | 200 | KG | |
| 90 | 90 | S&F rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates of Fe-410-W (Gde-E-250) quality ‘A’, complete all as specified and as directed | 300 | KG | |
| 91 | 91 | S&F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to walls, fixed with self tapping screws all as specified and as directed. | 25 | SQM | |
| 92 | 92 | Taking down cement plaster on brick walls etc. including racking out joints, hacking for key, scrubbing down with water etc all as specified and as directed. | 490 | SQM | |
| 93 | 93 | S & F GI wire netting 0.90mm dia and 12mm mesh lathing to metal studding, joists, etc. in walls including 8mm dia reinforcement with all laps, cutting and waste complete all as specified and as directed. | 30 | SQM | |
| 94 | 94 | M & L for Solid PVC Wall Lining consisting of 5mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame all as specified and as directed. | 290 | SQM | |
| 95 | 95 | M&L for applying two coats of weather proof paint (APEX of approved shade) over a coat of white primer including preparation of newly plastered surface all as directed by Engr in Charge. | 200 | SQM | |
| 96 | 96 | M&L 100mm thick, cement concrete 1:4:8, type D2 (40mm graded stone aggregate) as in sub base complete all as specified and directed. | 20 | SQM | |
| 97 | 97 | M & L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade laid over and including 50mm thick sand cushion and filling the joints with sand complete all as specified and as directed.\n | 20 | SQM | |
| 98 | 98 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in hard/dense soil complete all as specified and as directed. | 32 | CUM | |
| 99 | 99 | Removing excavated material to a distance not exceeding 50m and depositing where directed complete all as specified and as directed.\n | 16.3 | CUM | |
| 100 | 100 | Removing excavated material to a distance exceeding 250m and not exceeding 500m and depositing where directed complete all as specified and as directed.\n | 4 | CUM | |
| 101 | 101 | M&L for precast cement concrete 1:2:4 type-B1 as in landings, cover slabs, Chulla hoods, chajjas, water through mangers shelves and similar articles with plain faces set in CM 1:4 complete all as specified and as directed.\nNote: Reinforcement shall be measured and paid seperately\n | 0.7 | CUM | |
| 102 | 102 | M&L for preparation of newly plastered external wall surfaces of wall and applying two coats of cement base paint over a coat of primer complete all as specified and directed.\n | 17.5 | SQM | |
| 103 | 103 | Cutting into existing manholes for connecting new drains, making good\nto pipe and rendering, cutting out existing benching for and forming\nbranch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type\nB-l smooth finished, and reforming benching as required for 150mm dia pipe complete all as specified and as directed.\n | 1 | EACH\nPIPE | |
| 104 | 104 | M&L for PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in benching, coping, bed plates etc including necessary form work complete all as specified and as directed.\n | 0.8 | CUM | |
| 105 | 105 | M&L for brickwork with old size fly ash bricks, straight or curved on plan exceeding 6m mean radius, built in CM 1:4 complete all as specified and as directed. | 2.5 | CUM | |
| 106 | 106 | M & L for Reinforced concrete pipes, class NP2, 150mm dia laid and jointed complete with collars all as specified and as directed. | 70 | RM | |
| 107 | 107 | M & L for concrete bed to drain pipes of 150mm dia including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed. | 70 | RM | |
| 108 | 108 | M & L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds, mi- tred/stopped ends etc complete all as specified and as directed. | 3 | RM | |
| 109 | 109 | Supply and laying GI tubing of 50mm dia galvanised medium grade of any length including necessary fittings on floors/walls/ceilings/trenches complete all as specified and as directed. | 75 | RM | |
| 110 | 110 | S&F 50 mm gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe fixed complete all as specified and as directed. | 2 | EACH | |
| 111 | 111 | Cutting existing GI pipe of 80mm dia for taking branch connection of 50mm dia including insertion of new Gl tee reducing 80x80x50mm dia with necessary joints complete all as specified and as directed. | 1 | EACH\nJOB | |
| 112 | 112 | M&L for construction of valve chamber of size 600x600x600mm (inner dimensions) with PCC 1:4:8 type D2 for foundation with 15cm offset all round, 230mm thick brick wall in CM 1:6, PCC 1:2:4 type B-1 50mm thick for coping, rendering 15mm thick in CM 1:4 including provision of MS plate cover 3.15mm thick with angle iron frame made out of 40x40x6mm with two coats of synthetic enamel paint over one coat of red oxide primer and locking arrangement with Godrej lock including necessary excavation and earth work complete all as specified and as as directed. | 2 | EACH\nJOB | |
| 113 | 113 | M&L for point wiring with two single core 1.5 Sq.mm size multistranded copper conductor PVC insulated cables and one single core 1.5 Sq.mm size green colour PVC insulated, multistranded copper conductor PVC cable as earth continuity conductor,1100 volts grade, complete drawn in and including rigid PVC conduit of suitable size but not less than 19mm dia and conduit accessories, confirming to IS specifications, concealed in wall/ fixing on ceiling/trusses with suitable clamps , screws etc., including 1.22 mm thick MS terminal boxes with 3 mm thick plastic laminated sheet top cover fixed with cadmium plated iron screws for mounting switches, sockets, fan regulators etc., including connecting up and testing , all as specified and as directed for :- | |||
| 114 | 113.01 | One light point controlled by one switch | 44 | POINT | |
| 115 | 113.02 | One fan point controlled by one switch and regulator | 8 | POINT | |
| 116 | 113.03 | One switch socket outlet 3 pin 5 Amps on same board along with other switches. | 4 | POINT | |
| 117 | 113.04 | One switch socket outlet 3 pin 5 Amps on independent board. | 10 | POINT | |
| 118 | 114 | All as per item No 113.00 hereinbefore but with two single core 4 sqmm size cables and one 4 sq.mm green colour cable as earth continuity conductor for one switch socket out let 3 pin 15 Amps on independent board. | 6 | POINT | |
| 119 | 115 | S&F Switch piano flush type, single pole, 5 Amps, 240 volts all as specified and as directed | 52 | EACH | |
| 120 | 116 | S&F Switch socket 3 pin 5 amps, multi pin , flush type, all as specified and as directed. | 14 | EACH | |
| 121 | 117 | S&F Switch socket 3 pin 15 Amps, multipurpose, flush type all as specified and as directed. | 6 | EACH | |
| 122 | 118 | S&F Ceiling rose 65x50mm 3phase/PVC/Poly carbonate isolated body complete all as specified and as directed. | 52 | EACH | |
| 123 | 119 | S&F sheet metal enclosure with socket , plug top and MCB single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 20 Amps , 240 volts all as specified and as directed. | 2 | EACH | |
| 124 | 120 | S&F LED tube light fitting 22W wall mounted slim LED batten with all necessary accessories internally prewired including connecting up with twin core twisted flexible copper conductor complete all as specified and as directed.\nMake : Havells Cat No ENDURALINEARNEOBS22WLED865SPCWH or equivalent in Crompton Greaves/Philips | 38 | EACH | |
| 125 | 121 | S&F LED street light fitting 70W made up of pressure die cast housing with toufhened glass, IP 66 protection including drivers, connecting block etc., prewired and connecting up with suitable twin core flexible copper wire complete all as specified and as directed.\nMake : Havells Cat NoENDURAPEARLPLUSSL70WLED757SASYTOPC or equivalent Crompton Greaves/Philips | 6 | EACH | |
| 126 | 122 | S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and directed | 8 | EACH | |
| 127 | 123 | S&F TPN distribution board 8 ways factory made double door flush type all as per IS 8623 made from sheet metal duly powder coated to be fixed flush with wall complete with all accessories all as specified and as directed | 1 | EACH | |
| 128 | 124 | S&F TPN Load line distribution Board with MCCB 4 pole 63A, 25 KA incomer factory made double door flush type as per IS 8623 made from sheet metal duly powder coated for single phase outgoing and three phase incomer, with 200 Amps rated bus bar, 240V, 4 way flush with wall complete with all accessories all as specified and as directed. \n | 1 | EACH | |
| 129 | 125 | S&F SPN distribution board 8 ways factory made double door flush type all as per IS 8623 made from sheet metal duly powder coated to be fixed flush with wall complete with all accessories all as specified and as directed.\n | 1 | EACH | |
| 130 | 126 | S&F SPN distribution board 4 ways factory made double door flush type all as per IS 8623 made from sheet metal duly powder coated to be fixed flush with wall complete with all accessories all as specified and as directed.\n | 2 | EACH | |
| 131 | 127 | S&F MCB SPN 40 Amps, 240 volts of 10 KA rupturing capacity, C-curve type complete all as specified and as directed.\n | 4 | EACH | |
| 132 | 128 | S&F MCB SP 5 to 40 Amps, 240 volts of 10 KA rupturing capacity, B-curve type complete all as specified and as directed.\n | 24 | EACH | |
| 133 | 129 | M&L for power/sub main wiring with two runs of single core 6 Sqmm size and one run of single core 6 Sqmm (green colour as earth continuity conductor) PVC insulated, unsheathed, multistranded copper conductor cables of 1100 volts grade drawn through and including suitable size rigid PVC conduit of size not less than 25mm dia and accessories, all conforming to IS specification, concealed in wall fixing on ceiling/trusses etc. with suitable clamps, screws etc. and connecting up with terminal lugs all as specified and as directed. | 70 | RM | |
| 134 | 130 | M&L for electrical earthing complete with GI plate electrode of size 60cm x 60cm x 6.3mm thick buried directly in ground vertically at a depth not less than 2.25 mtr below normal ground level, with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire of 4mm dia by means of bolts, nuts and washers of galvanised iron, earth lead wire protected by means of 15mm bore light grade GI pipe upto switch board / panel board complete all as specified and as shown in MES schedule electrical plate No 3 of SSR Part I, including excavation and earth work in any type of soil, PCC 1:3:6 type C1 in chamber, RCC 1:2:4 type B1, 50mm thick cover slab with 8mm dia MS bars at 150mm centre both ways, with 6mm dia MS hook, charcoal dust, salt, GI pipe light grade 20mm bore with funnel for watering complete all as specified and as directed. | 2 | EACH SET | |
| 135 | 131 | Supply, laying, connecting and testing LT UG cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade sheathed, multi stranded of following cross sectional area complete all as specified and as directed :- Note :-(i) Lugs and glands are deemed to be included in the rate quoted for laying of cable and to be used properly wherever required while connecting cables to the panel board. (ii) Earth work such as excavation, refilling, etc. shall be measured separately under relevant items. | |||
| 136 | 131.01 | 3.5 core 35 Sqmm | 100 | RM | |
| 137 | 131.02 | 4 core 16 Sqmm | 50 | RM | |
| 138 | 131.03 | 2 core 6 Sqmm | 80 | RM | |
| 139 | 132 | Supply, fabricate, install, test and commissioning of LT panel board cubical, outdoor type (CPRI Approved manufacturer), AC, 3 Phase, 4 wire, 415/500v, 50 Hz, powder coated with FRP insulator fixed on angle iron frame of size 50x50x6mm, fabricated with 3.15mm thick mild steel and suitable size pressed steel frame work, factory made, bottom with detachable plates, front and rear with hinged type door and locking arrangement chamber for cable entry and exit, chamber for aluminium bus bars including aluminium bus bars 400 Amps 4 Nos, complete suitable for mounting following switch gear items internally connected with suitable capacity aluminium strips/road insulated complete including painting of panel boards with two coats synthetic enamel paint over one coat of red oxide primer complete all as specified and comprising of the following:-\nIncoming :-\n(a) MCCB 63 Amps, 4 Pole, 18 KA with adjustable thermal and adjustable magnetic setting-01 No.\n\n\n | 1 | EACH | |
| 140 | 132.01 | Outgoing :-\n(a) MCCB 32 Amps 3 Pole, 10 KA with adjustable thermal and fixed magnetic setting-02 Nos.\n(b) MCCB 25 Amps 3 Pole, 10 KA with adjustable thermal and fixed magnetic setting-02 Nos.\n(c) Digital volt meter 0-500 volts with selector switch-01 Nos, Make : AE/Havells/Autonix/HPL\n(d) Digital Amp meter 0-200 Amps with selector switch and CT-01 No, Make : AE/Havells/Autonix/HPL\n(e) LED indicator RYB-03 No, Make : AE/Havells/Autonix/HPL.\n(f) Danger board with conventional sign of skull and bone and in Tamil/English\n(g) Internal wiring with PVC insulated copper conductor of appropriate gauge complete all as directed. | |||
| 141 | 133 | M&L for electrical earthing complete with GI plate electrode of size 60cm x 60cm x 6.3mm thick buried directly in ground vertically at a depth not less than 2.25 mtr below normal ground level, with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level, connected to GI earth strip of size 32x6mm as earth lead by means of bolts, nuts and washers of galvanised iron, earth lead wire protected by means of 15mm bore light grade GI pipe upto switch board / panel board complete all as specified and as shown in MES schedule electrical plate No 3 of SSR Part I, including excavation and earth work in any type of soil, PCC 1:3:6 type C1 in chamber, RCC 1:2:4 type B1, 50mm thick cover slab with 8mm dia MS bars at 150mm centre both ways, with 6mm dia MS hook, charcoal dust, salt, GI pipe light grade 20mm bore with funnel for watering complete all as specified and as directed. | 2 | EACH SET | |
| 142 | 134 | Supply and lay rubber mat (Anti static mat) of size 1mx2mx10mm conforming to releavant IS complete all as specified and as directed. | 2 | EACH | |
| 143 | 135 | Supply, lay, spread in trenches of river sand including spreading, leveling, punning for cushioning of cable all as specified and as directed.\nNote : Punned depth shall be measured and paid separately\n | 15 | CUM | |
| 144 | 136 | Supply, lay in trenches fly ash bricks, old size for cable protection all as specified and directed. Note:- Bricks shall be laid in such a way that its length is perpendicular to the length of cable.\n | 1472 | EACH | |
| 145 | 137 | M&L for power/sub main wiring with two runs of single core 1.5 Sqmm size and one run of single core 1.5 Sqmm (green colour as earth continuity conductor) PVC insulated, unsheathed, multistranded copper conductor cables of 1100 volts grade drawn through and including suitable size rigid PVC conduit of size not less than 25mm dia and accessories, all conforming to IS specification, concealed in wall fixing on ceiling/trusses etc. with suitable clamps, screws etc. and connecting up with terminal lugs all as specified and as directed. | 10 | RM | |
| 146 | 138 | Supply, install commissioning and testing of solar LED 15W standalone street light DC luminaire including SPV panel, lead Acid battery, powder coated MS pole complete all as specified and as directed. \nMake : havells, Model No: LHSTAOU7CABD015 or equivalent in Phiplips/CG | 1 | EACH | |
| 147 | 139 | Supply, install commissioning and testing of air colled split unit air conditioner, electric driven, single phase of capacity 2 TR BEE, 5 star rated complete with out door unit stand and PVC drain pipe connected with all units including making hole for copper pipe and making good the same to match with adjascent surfaces complete all as specified and as directed.\nMake : Carrier/Blue star/Daikin | 2 | EACH | |
| 148 | 140 | Supply, install and testing Voltage stablizer for automatic operation, single phase naturally air cooled, indoor type & designed for input voltage variation between 170 volts to 250 volts with out put voltage stablized at 230 volts with accuracy of + 2.5% and of capacity 4 KVA fixed on wall complete all as specified and as directed. | 2 | EACH |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail