Annual Preventive Maintenance Of Ht And Lt Electrical Installation Work At Iim Indore . Yearly Testing Of Ht/Lt Equipments As Per Mpeb Inspection Report -Annual Preventive Maintenance Of Ht And Lt Electrical Installation Work At Iim Indore ., IIM Indore-Madhya Pradesh

Indian Institute Of Management has published Annual Preventive Maintenance Of Ht And Lt Electrical Installation Work At Iim Indore . Yearly Testing Of Ht/Lt Equipments As Per Mpeb Inspection Report -Annual Preventive Maintenance Of Ht And Lt Electrical Installation Work At Iim Indore .. Submission Date for this Tender is 16-12-2019. Electrical Maintenance Tenders in IIM Indore Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

22745737
Annual Preventive Maintenance Of Ht And Lt Electrical Installation Work At Iim Indore . Yearly Testing Of Ht/Lt Equipments As Per Mpeb Inspection Report -Annual Preventive Maintenance Of Ht And Lt Electrical Installation Work At Iim Indore .
Tender
Indian
Madhya Pradesh
Iim Indore
16-12-2019

Tender Details

Annual Preventive Maintenance Of Ht And Lt Electrical Installation Work At Iim Indore . Yearly Testing Of Ht / Lt Equipments As Per Mpeb Inspection Report -Annual Preventive Maintenance Of Ht And Lt Electrical Installation Work At Iim Indore . , Vacuum Circuit Breakers:- Service Charges For Carrying Out Servicing And Overhauling Of 1250 Ampere , Indoor Type 33 Kv , 3 Phase , 50 Hz , Make - Alstom , Type - Vmx , Vcb By Drawing Out The Draw-Out Module Of The Breaker , Carrying Out Complete Cleaning With Clean Cloth & Cleaning Agent , Lubrication Of The Mechanism & Greasing With High Temperature Molly Grease , Testing For Smoother On / Off Operation , Carrying Out Relay Calibration Of Protection Relay By Secondary Current Injection Methods To Check Trip Time Characteristic Of Relay , Checking Of Healthiness Of Cts & Pts Chacking Of Ir Value Of Interrupters , Heaithiness Of Protection Tripping Of Circuit Breaker Etc . Checking And Service Switchgear Interlocks And Safety Like ( Mechanical: - 1 . Positive Interlock , 2 . Negative Interlock , 3 . Spring Discharge Interlock , 4 . Padlocks , 5 . Key Interlocking , 6 . Safety Roll In Stop , 7 . Safety Roll-Out Stop , 8 . Rating Interference Interlock ) . ( Electrical:- Interlock Switches ) Checking Of Electrical Operations Of The Breaker For On / Off & Trip Operation For Incomer And Outgoing Including Submission Of Service & Test Reports . The Service To Be Done By Authorised Service Provider Of Alstom . The Rate Shall Include The Material , Labour , Transportation , Tools And Tackles Etc Complete As Required . , Vacuum Circuit Breakers:- Service Charges For Carrying Out Servicing And Overhauling Of 630 Ampere , Indoor Type 11 Kv , 3 Phase , 50 Hz , Make - Alstom , Type - Vmx , Vcb By Drawing Out The Draw-Out Module Of The Breaker , Carrying Out Complete Cleaning With Clean Cloth & Cleaning Agent , Lubrication Of The Mechanism & Greasing With High Temperature Molly Grease , Testing For Smoother On / Off Operation , Carrying Out Relay Calibration Of Protection Relay By Secondary Current Injection Methods To Check Trip Time Characteristic Of Relay , Checking Of Healthiness Of Cts & Pts Chacking Of Ir Value Of Interrupters , Heaithiness Of Protection Tripping Of Circuit Breaker Etc . Checking And Service Switchgear Interlocks And Safety Like ( Mechanical: - 1 . Positive Interlock , 2 . Negative Interlock , 3 . Spring Discharge Interlock , 4 . Padlocks , 5 . Key Interlocking , 6 . Safety Roll In Stop , 7 . Safety Roll-Out Stop , 8 . Rating Interference Interlock ) . ( Electrical:- Interlock Switches ) Checking Of Electrical Operations Of The Breaker For On / Off & Trip Operation For Incomer And Outgoing Including Submission Of Service & Test Reports . The Service To Be Done By Authorised Service Provider Of Alstom . The Rate Shall Include The Material , Labour , Transportation , Tools And Tackles Etc Complete As Required . , Vacuum Circuit Breakers:- Service Charges For Carrying Out Servicing And Overhauling Of 630 Ampere , Indoor Type 11 Kv , 3 Phase , 50 Hz , Make - Crompton Greaves , Type - Vmx , Vcb By Drawing Out The Draw-Out Module Of The Breaker , Carrying Out Complete Cleaning With Clean Cloth & Cleaning Agent , Lubrication Of The Mechanism & Greasing With High Temperature Molly Grease , Testing For Smoother On / Off Operation , Carrying Out Relay Calibration Of Protection Relay By Secondary Current Injection Methods To Check Trip Time Characteristic Of Relay , Checking Of Healthiness Of Cts & Pts Chacking Of Ir Value Of Interrupters , Heaithiness Of Protection Tripping Of Circuit Breaker Etc . Checking And Service Switchgear Interlocks And Safety Like ( Mechanical: - 1 . Positive Interlock , 2 . Negative Interlock , 3 . Spring Discharge Interlock , 4 . Padlocks , 5 . Key Interlocking , 6 . Safety Roll In Stop , 7 . Safety Roll-Out Stop , 8 . Rating Interference Interlock ) . ( Electrical:- Interlock Switches ) Checking Of Electrical Operations Of The Breaker For On / Off & Trip Operation For Incomer And Outgoing Including Submission Of Service & Test Reports . The Service To Be Done By Authorised Service Provider Of Alstom . The Rate Shall Include The Material , Labour , Transportation , Tools And Tackles Etc Complete As Required . , Vacuum Circuit Breakers:- Service Charges For Carrying Out Servicing And Overhauling Of 630 Ampere , Indoor Type 11 Kv , 3 Phase , 50 Hz , Make - Abb , Type - Vmx , Vcb By Drawing Out The Draw-Out Module Of The Breaker , Carrying Out Complete Cleaning With Clean Cloth & Cleaning Agent , Lubrication Of The Mechanism & Greasing With High Temperature Molly Grease , Testing For Smoother On / Off Operation , Carrying Out Relay Calibration Of Protection Relay By Secondary Current Injection Methods To Check Trip Time Characteristic Of Relay , Checking Of Healthiness Of Cts & Pts Chacking Of Ir Value Of Interrupters , Heaithiness Of Protection Tripping Of Circuit Breaker Etc . Checking And Service Switchgear Interlocks And Safety Like ( Mechanical: - 1 . Positive Interlock , 2 . Negative Interlock , 3 . Spring Discharge Interlock , 4 . Padlocks , 5 . Key Interlocking , 6 . Safety Roll In Stop , 7 . Safety Roll-Out Stop , 8 . Rating Interference Interlock ) . ( Electrical:- Interlock Switches ) Checking Of Electrical Operations Of The Breaker For On / Off & Trip Operation For Incomer And Outgoing Including Submission Of Service & Test Reports . The Service To Be Done By Authorised Service Provider Of Alstom . The Rate Shall Include The Material , Labour , Transportation , Tools And Tackles Etc Complete As Required . , Air Circuit Breaker: Complete Service , Overhauling , Repairing , Cleaning , Oiling With Setting Of Tripping Mechanism Of Following Air Circuit Breaker ( Acbs ) Including Submission Of Service & Test Reports . The Serviceing To Be Done By Authorised Service Provider Of Ge And L&T . , 3200 Amp Mdo / Edo 4P Acb Of Ge Make , 2500 Amp Mdo / Edo 4P Acb Of Ge Make , 1000 Amp Mdo / Edo 4P Acb Of Ge Make , 1600 Amp Mdo / Edo 4P Acb Of L&T Make Model C- Power , 1000 Amp Mdo / Edo 4P Acb Of L&T Make Model C- Power , 1600 Amp Edo 4P Acb Of L&T Make Model U- Power , 2000 Amp Edo 4P Acb Of L&T Make Model U- Power , 1000 Amp Edo 4P Acb Of L&T Make Model U- Power , 800 Amp Edo 4P Acb Of L&T Make Model U- Power , 1000 Amp Edo 3P Acb Of Ge Make Model M-Pact Type . , Calibration And Setting Of The Static / Electromechnical Relay Over Voltage Relay - 01 No , Under Voltage Relay - 01 No . Over Current - 02 Nos & Earth Fault Relay - 01 Nos . Master Trip Relay ( B / A , Wt / A , Ot / A ) & ( B / T , Wt / T , Ot / T ) Test By Secondary Injection Test . The Report Will Be Prepared And To Be Submit . Calibration And Setting Of The Relay Need To Be Carryout As Per Actual Loading Condition . Also Submit The Calculation Sheet For Relay Setting . , Calibration And Setting Of The Relay Over Current 02 Nos . & Earth Fault Relay 01 . Nos . , Master Trip Relay ( B / A , Wt / A , Ot / A ) & ( B / T , Wt / T , Ot / T ) Test By Secondary Injection Test . The Report Will Be Prepared And To Be Submit . Calibration And Setting Of The Relay Need To Be Carryout As Per Actual Loading Condition . Also Submit The Calculation Sheet For Relay Setting . , Calibration And Setting Of The Relay Over Current 02 Nos . & Earth Fault Relay 01 . Nos . , Test By Secondary Injection Test . The Report Will Be Prepared And To Be Submit . Calibration And Setting Of The Relay Need To Be Carryout As Per Actual Loading Condition . Also Submit The Calculation Sheet For Relay Setting . , Annual Maintenance Of Transformers & Switchyard . Complete Serviceing Of Oil- Filter Transformerof Following Rating , Including Replacement Of Gaskets To Prevent Oil Leakage As Per Reqirement , Replacement Of Silica Gel ,

Key Value

Document Fees
INR 500 /-
EMD
INR 17187.0 /-
Tender Value
INR 8.59 Lakhs /-